ENSAYO DE CORTE DIRECTO Proyecto : "MEJORAMIENTO DE LOS SERVICIOS DE RECREACIÓN Y ESPACIAMIENTO EN EL SECTOR PUBLICO CO
Views 45 Downloads 0 File size 1MB
ENSAYO DE CORTE DIRECTO Proyecto
: "MEJORAMIENTO DE LOS SERVICIOS DE RECREACIÓN Y ESPACIAMIENTO EN EL SECTOR PUBLICO COOVITSPA DEL DISTRITO DE AYACUCHO, PROVINCIA DE HUAMANGA, DEPARTAMENTO DE AYACUCHO"
Solicitante
: MUNICIPALIDAD PROVINCIAL DE HUAMANGA
Región
: AYACUCHO
Calicata
: C - 01
Provincia
: HUAMANGA
Estrato
: E - 02
Distrito
: AYACUCHO
Fecha
: ABRIL DE 2019
Lugar
: SECTOR PUBLICO COOVITSPA
E S FU E R Z O D E C O R T E (k g /cm 2)
E S FU E R Z O D E C O R T E (k Pa)
(ASTM D 3080, AASHTO T 236, MTC E 123)
DEFORMACION TANGENCIAL VS ESFUERZO DE CORTE 260.00 240.00 220.00
ESFUERZO NORMAL VS ESFUERZO DE CORTE 2.75 2.50
200.00
2.25
180.00
2.00
160.00
1.75
140.00
f(x) = 0.591369698571428 x + 0.004052256000001
1.50
120.00
1.25
100.00 80.00
1.00
60.00
0.75
40.00
0.50
20.00
0.25
0.00 0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
5.50
6.00
DEFORMACION TANGENCIAL (mm)
1.0 kg/cm2
2.0 kg/cm2
6.50
7.00
0.00 0.0
0.2
0.4
Angulo de friccion interna φ' (°) : 30.6 4.0 kg/cm2
Cohesion C' (kg/cm2) : 0.00
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
ESFUERZO NORMAL (kg/cm2)
3.0
3.2
3.4
3.6
3.8
4.0
4.2
Direccion: Asoc. Covandonga Mz "T" Lt N° 4 – HUAMANGA - AYACUCHO, CEL: 999606084, TEL: 066-280063, EMAIL: [email protected]
ENSAYO DE CORTE DIRECTO (ASTM D 3080, AASHTO T 236, MTC E 123) Proyecto
: "MEJORAMIENTO DE LOS SERVICIOS DE RECREACIÓN Y ESPACIAMIENTO EN EL SECTOR PUBLICO COOVITSPA DEL DISTRITO DE AYACUCHO, PROVINCIA DE HUAMANGA, DEPARTAMENTO DE AYACUCHO"
Solicitante
: MUNICIPALIDAD PROVINCIAL DE HUAMANGA
Región
: AYACUCHO
Calicata
: C - 01
Provincia
: HUAMANGA
Estrato
: E - 02
Distrito
: AYACUCHO
Fecha
: ABRIL DE 2019
Lugar
: SECTOR PUBLICO COOVITSPA
DATOS Especimen
: REMOLDEADO (MATERIAL < MALLA N° 4)
Profundidad
: E - 02
Tipo de Celda
: CUADRADA
Lado o Diametro Celda : Tipo de ensayo :
63.69 mm
Espesor de muestra en celda:
21.55 mm
CONSOLIDADO DRENADO 1
2
3
Lado o Diametro de la muestra (mm) :
63.69
63.69
63.69
Altura inicial de la muestra (mm) :
21.55
21.55
21.55
Densidad Humeda Inicial (tn/m3) :
1.460
1.460
1.460
Contenido de Humedad (%) :
8.10%
8.10%
8.10%
Densidad Seca Inicial (tn/m3) :
1.351
1.351
1.351
Deformacion vertical despues de la consolidacion (mm) :
0.732
1.154
1.784
Altura de la muestra antes de aplicar el esfuerzo de corte (mm) :
20.818
20.396
19.766
1
2
4
Esfuerzo de Corte Maximo (Kpa) :
60.69
113.00
233.59
Esfuerzo de Corte Maximo (kg/cm2) :
0.62
1.15
2.38
Especimen N°
Esfuerzo Normal (kg/cm2) :
Angulo de friccion interna φ' (°) :
30.6
Cohesion C' (kg/cm2) :
0.00
Direccion: Asoc. Covandonga Mz "T" Lt N° 4 – HUAMANGA - AYACUCHO, CEL: 999606084, TEL: 066-280063, EMAIL: [email protected]
ENSAYO DE CORTE DIRECTO (ASTM D 3080, AASHTO T 236, MTC E 123) Proyecto
: "MEJORAMIENTO DE LOS SERVICIOS DE RECREACIÓN Y ESPACIAMIENTO EN EL SECTOR PUBLICO COOVITSPA DEL DISTRITO DE AYACUCHO, PROVINCIA DE HUAMANGA, DEPARTAMENTO DE AYACUCHO"
Solicitante
: MUNICIPALIDAD PROVINCIAL DE HUAMANGA
Región
: AYACUCHO
Calicata
: C - 01
Provincia
: HUAMANGA
Estrato
: E - 02
Distrito
: AYACUCHO
Fecha
: ABRIL DE 2019
Lugar
: SECTOR PUBLICO COOVITSPA
Direccion: Asoc. Covandonga Mz "T" Lt N° 4 – HUAMANGA - AYACUCHO, CEL: 999606084, TEL: 066-280063, EMAIL: [email protected]
0 LABORATORIO DE 0 0 ENSAYO DE CORTE DIRECTO 0 Formato de registro de ensayos F-20 Cliente: * Proyecto: * Sondeo * Material: * Descripción: * Temperatura *
TIPO DE ENSAYO: Parámetros de la muestra Lado (mm) Área (mm²) Altura (mm) Humedad natural (%) Peso del suelo húmedo (g) Peso del suelo seco (g) Gravedad específica (g/cm ³) Masa unitaria húmeda (g/cm³) Masa unitaria seca (g/cm³) Grado de Saturación (%) Relación de vacíos inicial Deformación Consolidación (mm) Relación de vacíos final Parámetros del Ensayo Pesas en el brazo (kg) Peso del estribo (kg) Múltiplo del brazo de palanca Velocidad desplazam. (mm/min) Esfuerzo Vetical (kPa) Consolidar Deformación Deformación Horizontal Unitaria (mm) (%) Esfuerzo Vertical (kPa) ® 0.00 0.00 0.10 0.06 0.20 0.13 0.30 0.19
Humedad Relat. *
°C
CONSOLIDADO, DRENADO
96.5 0.000 0.000 0.000 0.046
Ítem 1 63.69 4,056.42 21.55 * * * *
Ítem 2 63.69 4,056.42 21.55 * * * *
0.73
1.15
7.270 3.550 5.000 0.300 96.5 SI
15.225 3.550 5.000 0.300 192.6 SI
Deformación Normal (mm) 192.6 385.7 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0.40 0.50 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00 10.50 11.00 11.50 12.00 12.50 13.00 13.50 14.00 14.50 15.00 15.50 16.00 16.50
0.25 0.32 0.38 0.45 0.51 0.57 0.64 0.76 0.89 1.02 1.15 1.27 1.59 1.91 2.23 2.55 2.87 3.18 3.50 3.82 4.14 4.46 4.78 5.10 5.41 5.73 6.05 6.37 6.69 7.01 7.32 7.64 7.96 8.28 8.60 8.92 9.24 9.55 9.87 10.19 10.51 10.83 11.15 11.46 11.78 12.10 12.42 12.74
0.135 0.232 0.325 0.371 0.464 0.557 0.603 0.789 0.974 1.160 1.299 1.439 1.717 1.949 2.135 2.320 2.413 2.552 2.645 2.738 2.877 2.923 3.016 3.063 3.155 3.202 3.248 3.295 3.341 3.387 3.434 3.480 3.527 3.527 3.619 3.666 3.712 3.712 3.759 3.805 3.852 3.898 3.898 3.944 3.944 3.991 4.037 4.037
0.046 0.093 0.186 0.274 0.371 0.464 0.557 0.742 0.928 1.021 1.206 1.346 1.671 1.903 2.135 2.320 2.455 2.599 2.687 2.784 2.831 2.923 2.970 3.063 3.155 3.248 3.341 3.434 3.527 3.619 3.666 3.712 3.759 3.852 3.852 3.898 3.898 3.944 3.991 3.991 4.037 4.084 4.130 4.130 4.130 4.176 4.218 4.269
0.000 0.046 0.046 0.093 0.135 0.232 0.274 0.418 0.510 0.603 0.696 0.835 1.114 1.346 1.531 1.763 1.949 2.088 2.181 2.320 2.413 2.552 2.645 2.877 3.016 3.063 3.202 3.248 3.295 3.387 3.434 3.527 3.527 3.619 3.666 3.712 3.852 3.852 3.898 3.944 3.991 3.991 4.037 4.084 4.084 4.130 4.130 4.176
17.00 17.50 18.00 18.50 19.00 19.50 20.00 Observaciones:
Técnico: Máquina de ensayos:
LABORATORIO DE ENSAYO DE MATERIALES
E CORTE DIRECTO - ASTM D - 3080
Rev 05 2013-02-08
Fecha de ensayo: 7/9/2020 Fecha de muestreo: Ensayo No.: 140 Identificación de la muestra: %
INALTERADA
Profundidad: *
Ítem 2 63.69 4,056.42 21.55 * * * *
Ítem 3 63.69 4,056.42 21.55 * * * *
1.15
1.78
15.225 3.550 5.000 0.300 192.6 SI
31.200 3.550 5.000 0.300 385.7 SI
96.5 4.60 20.00 24.60 40.40
Fuerza (N) 192.6 385.7 5.80 2.40 23.40 14.60 36.20 23.20 81.00 56.80
m
Ítem 4 * * * * * *
* * * *
96.5 1.13 4.93 6.06 9.96
Esfuerzo Cortante (kPa) 192.6 385.7 1.43 0.59 5.77 3.60 8.92 5.72 19.97 14.00
###
###
55.40 64.80 73.20 80.60 87.00 93.80 99.20 109.20 119.00 126.40 134.60 143.20 161.00 175.40 187.00 196.80 205.40 213.20 218.20 226.40 229.80 235.40 238.60 242.00 247.80 249.40 253.20 256.40 259.00 261.60 263.40 267.00 267.20 268.40 269.20 272.40 275.20 278.00 281.80 284.60 286.20 286.60 289.00 289.40 290.80 293.80 293.40 295.80
112.00 132.80 149.00 160.00 172.80 184.20 194.00 214.20 231.60 244.80 256.00 266.40 297.20 324.40 346.60 369.80 386.20 400.80 414.00 422.00 429.60 431.20 438.00 445.00 449.00 459.20 468.00 471.20 482.20 486.40 490.80 491.40 498.40 495.20 496.40 496.00 504.80 507.40 511.20 513.40 513.20 516.40 523.00 522.60 525.00 524.00 531.00 523.20
100.40 143.20 185.20 217.00 244.40 271.40 294.00 339.80 376.40 408.80 442.20 474.20 550.20 609.80 663.60 714.40 759.60 806.00 843.40 879.60 907.60 933.00 958.20 958.60 994.00 1012.40 1035.20 1049.40 1064.00 1074.40 1086.20 1099.80 1107.40 1117.20 1122.20 1129.00 1130.20 1140.20 1141.40 1144.40 1145.60 1143.20 1145.80 1147.20 1149.60 1155.80 1156.20 1161.80
13.66 15.98 18.05 19.87 21.45 23.12 24.46 26.92 29.34 31.16 33.18 35.30 39.69 43.24 46.10 48.52 50.64 52.56 53.79 55.81 56.65 58.03 58.82 59.66 61.09 61.48 62.42 63.21 63.85 64.49 64.93 65.82 65.87 66.17 66.36 67.15 67.84 68.53 69.47 70.16 70.56 70.65 71.25 71.34 71.69 72.43 72.33 72.92
27.61 32.74 36.73 39.44 42.60 45.41 47.83 52.81 57.10 60.35 63.11 65.67 73.27 79.97 85.45 91.16 95.21 98.81 102.06 104.03 105.91 106.30 107.98 109.70 110.69 113.20 115.37 116.16 118.87 119.91 120.99 121.14 122.87 122.08 122.37 122.28 124.45 125.09 126.02 126.57 126.52 127.30 128.93 128.83 129.43 129.18 130.90 128.98
24.75 35.30 45.66 53.50 60.25 66.91 72.48 83.77 92.79 100.78 109.01 116.90 135.64 150.33 163.59 176.12 187.26 198.70 207.92 216.84 223.74 230.01 236.22 236.32 245.04 249.58 255.20 258.70 262.30 264.86 267.77 271.13 273.00 275.42 276.65 278.33 278.62 281.09 281.38 282.12 282.42 281.83 282.47 282.81 283.40 284.93 285.03 286.41
### ###
###
###
###
Director:
INSTRUCCIONES Función de los botones: INICIALIZAR: Valida la clave de acceso y genera número de ensayo. Para cada muestra, limpia el área de datos de ensayo, calcula y guarda en archivo los parámetros de ensayo. Actualiza el estado de la máquina y pone en cero todas las variables. Prueba el puerto de comunicación con la máquina (celda "X1") y lo activa. Se confirma con un mensaje. CONSULTAR ARCHIVOS: Permite recuperar datos de ensayos realizados IMAGEN 1/2: Selecciona tipo de celda redonda/cuadrada. Modifica la configuración de la máquina MUESTRA # INICIAR: Inicia el ensayo: Arranca la máquina (ensayo de corte) y inicia captura automática de datos del ensayo. MUESTRA # TERMINAR: Detiene el ensayo y la captura y registro de datos. Muestra el botón siguiente LIMPIAR HOJA: Borra totalmente el contenido de la hoja de cálculo. ENTRADA DE PARÁMETROS: Digite los parámetros del cliente y la muestra en las celdas correspondientes. Las celdas
*
marcadas con rojo son necesarias para realizar cálculos automáticos. Puede digitar de una vez los datos para las cuatro muestras. Para terminar confirme con "Enter" (¿) REALIZAR ENSAYOS: -Preferiblemente limpie la hoja antes (botón "BORRAR") - 1) Haga click sobre el botón "inicializar . 2) digite los datos del cliente y la muestra y los parámetros del ensayo - las dimensiones de la celda y el valor de las pesas y
*
múltiplo del brazo, marcados con son necesarios para hacer cálculos y registros - 3) haga click en el botón "MUESTRA # INICIAR".- 4) Para detener el ensayo haga click sobre el botón activo - 5) Para cada muestra repita los pasos 2 , 3 y 4.
1258,20 8,53 Fuerza (N)
Deform. Hztal (mm)
Carpeta de trabajo
C:\ Puerto 3
-0.153 27:43 Deform. Normal (mm)
Tiempo (M:S)
Restaurar INICIALIZAR INICIALIZAR
CCE ERRRRAARR
Restaurar
Restaurar
Consultar Archivos Consultar Archivos
LIMPIAR HOJA LIMPIAR HOJA
Muestra 4 4 Muestra
Prueba dede Datos Prueba Datos
HABILITAR PARADA AUTOMÁTICA HABILITAR PARADA AUTOMÁTICA INSTRUCCIONES Continuación CONSULTAR ARCHIVOS: Seleccionar archivo: Al picar sobre el botón "CONSULTAR ARCHIVOS" se despliega una ventana de diálogo. Digite el número del archivo a consultar y confirme con ENTER. Continuar el ensayo: Cuando no es posible hacer los ensayos de las cuatro muestras, en un mismo día por ejemplo, es posible completar el ensayo en la misma hoja de cálculo. Consulte el ensayo que quedó suspendido y confirme que desea continuar y pique sobre el botón "CONTINUA ENSAYO". El botón mostrará ahora "MUESTRA # INICIAR" . El sistema está ahora listo para continuar. Realice los ensayos de la misma forma.
Prueba de datos: Permite Confirmar si los datos recibidos desde la máquina se están leyendo correctamente. CUIDADO. La máquina se activará - Realice esta prueba preferiblemente sin la muestra. Durante la prueba, la máquina enviará datos correspondientes para un ensayo de corte directo, que podrá ver en las celdas previstas para la indicación de fuerza, avance horizontal, deformación vertical y tiempo. Con la mano puede mover ligeramente el comparador de carátula digital o hacer presión sobre la celda de carga y observar si las lectura que muestra la hoja de cálculo coinciden con la las lecturas de la máquina.
DATOS PARA CORTE EN CELDA CUADRADA LADO:
63.69 mm.
AREA:
4056.42 mm2.
ALTURA: MASA:
21.55 mm. 137.09 gr.
VOLUMEN:
258353.14 mm3.
VOLUMEN:
87415.77 mm3.
VOLUMEN:
87.42 cm3.
PESO DEL ESTRIBO:
3.55 Kg.
VELOCIDAD ESTANDAR:
0.30 mm/seg
VELOCIDAD RAPIDA:
0.50 mm/seg
0.5 Kg/cm2
1 Kg/cm2
1.5 Kg/cm2
2 Kg/cm2
3 Kg/cm2
4 Kg/cm2
1/10:
1.64 Kg
3.64 Kg
5.63 Kg
7.625 Kg
11.616 Kg
15.60 Kg
1/5:
3.28 Kg
7.27 Kg
11.26 Kg
15.225 Kg
23.232 Kg
31.20 Kg
DATOS PARA CORTE EN CELDA CIRCULAR DIAMETRO. AREA: ALTURA: MASA:
51.13 mm. 2053.25 mm2. 22.19 mm. 119.36 gr.
VOLUMEN:
45561.58 mm3.
VOLUMEN:
45.56 cm3.
PESO DEL ESTRIBO:
3.55 Kg.
VELOCIDAD ESTANDAR:
0.125 mm/seg
VELOCIDAD RAPIDA:
0.15 mm/seg
0.5 Kg/cm2
1 Kg/cm2
1.5 Kg/cm2
2 Kg/cm2
3 Kg/cm2
1/10:
0.64 Kg
1.64 Kg
2.63 Kg
3.63 Kg
5.62 Kg
1/5:
1.28 Kg
3.27 Kg
5.26 Kg
7.25 Kg
11.23 Kg
OJO: SIEMPRE SACAR LOS PERNOS CENTRALES DE LA CELDA DESPUES DE LA CONSOLIDACION Y ANTES DE REALIZAR EL CORTE ¡GRACIAS!