ELENESSA and GPS-3 fault table E1 SWTGBL abnormally low speed E2 SWTGBH abnormal high speed E3 SWTGBR Reverse-ru
Views 331 Downloads 15 File size 70KB
ELENESSA and GPS-3 fault table E1
SWTGBL
abnormally low speed
E2
SWTGBH
abnormal high speed
E3
SWTGBR
Reverse-run detection
E4
SWAST
E5
SSIOCFO (IOCH)
overcurrent (transformer, E1, module)
E6
SSCOVH
overvoltage (inductance, lack of phase)
E7
SSLVLT
undervoltage (temperature insurance, E1, regeneration)
E8
SWCFLB
#LB OFF failure
E9
SWCF5
#5 OFF fault
EA
SWCFBK
brake contactor ON/OFF failure
EB
STSTSCE
car serial failure
EC
STSTSHE
landing station serial failure
Anti-stole timer
ED
STSYER
system failure (P1 setting)
EE
SDDNRS
can no longer be started (drive)
EF
SWNRS
can no longer be started (control)
Machine room 01
INV temperature detection
02
E-STOP once
03
CC-WDT 3 times
04
SLC-WDT 3 times
05
motor over current
06
brake resistor overload
07
41 contactor failure
08
Terminal deceleration switch failure
09
level switch failure
0A
weighing device failure
0B
E1 board failure
0C
UHS/DHS switch failure 0D DZ detection loop failure
0F
LB failure
11
remote reset / test
12
layer selector error 16 times
13
serial failure
14
Capacitor capacity is insufficient
15
manual run button\fault
16
speed graphics jump 5 times
17
#LB action failed 5 times
18
#5 action failed 5 times
19
#BK1 action failed 5 times
1A
#BK2 action failed 5 times
1B
LVLT 5 times
1C
E1 board failure
1D
fan failure
1E
Fan or E1 board failure
1F
Fan or E1 board failure
21
#5 ON failure
22
E-STOP twice
23
system failure
ELENESSA and GPS-3 fault table 24
reset request
25
PCB base drive failure
26
DC-CT failure
28
immersion sensor failure
29
Anti-immersion action ends
2A
#PWD shutdown command lasts 3 minutes
2B
handrail switch remains
2C
brake drag operation ends
2D
brake re-action failure
2F
selector is faulty 16 times
31
MELD overload
32
abnormally low speed
33
abnormal high speed
34
Reverse timing (motor running time limit)
35
reverse operation
36
reverse timer
37
reverse timer
38
inverter overvoltage
39
Inverter undervoltage
3A
CC-WDT 4 times
3B
SLC-WDT 4 times
3C
inverter over current
3D
SLC E-stop
3E
encoder failure (automatic)
3F
encoder failure (manual)
41
two E-STOP
42
INV undervoltage
43
E-stop F/F reset
44
#LB coil failure
45
#5 coil failure
46
#BK1 coil failure
47
#BK2 coil failure
48
Power on
4B
inverter charging failed
51
electrical safety circuit
52
#29 latch (may be R1 board bad 5# sparker bad)
53
Power failure (DC power failure)
54
INV undervoltage
55
12V power failure
56
control screen open
57
manual overload operation
58
drive S/W E-stop
59
Management S/W E-stop (Z1 board is broken)
5B
abnormal brake sliding distance
61
Inverter undervoltage
62
PCB base drive failure
63
INV protection circuit action
64
#29 latch
65
12V power failure
ELENESSA and GPS-3 fault table 66
temperature switch exceeds 75 degrees
67
temperature switch over 90 degrees
68
temperature switch cooling / connector disconnection
69
inverter over current
6A
inverter overvoltage
6B
power off (DC power failure)
6C
E1 board warning
6D
DC power failure
6E
AC power failure
6F
#PWD (power failure detection)
71
CC-WDT 5 times
72
CC-WDT 4 times
73
CC-WDT 3 times
74
SLC-WDT 5 times
75
SLC-WDT 4 times
76
SLC-WDT 3 times
7C
weighing plate is less than 30 degrees
7D
weighing plate 30-40 degrees
7E
weighing plate over 60 degrees
7F
weighing device A/D conversion
81
#BK1 over current
82
#BK2 over current
83
#BK1 DC-CT disconnection
84
#BK2 DC-CT disconnection
85
#BK1 Coil failure
86
#BK2 Coil failure
87
#BK1 coil short circuit
88
#BK2 Coil short circuit
89
#BK1 DC-CT failure
8A
#BK2 DC-CT failure
8B
#BK1 coil is shorted
91
drive E-stop
92
motor over current
93
can no longer be started (drive S/W)
94
MELD overload operation
95
TSD switch failure
96
Weighing device failure
97
DC-CT failure
98
TSD operation
99
encoder Z phase failure
9A
encoder F phase failure
9B
with timer motor over current detection
9E
door cut-off circuit failure
A1
graphics - speed jump
A2
speed graphics jump exception
A3
driver S/W E-stop
A4
regenerative resistor overload
A6
manual overload operation
A7
MCP inverter overcurrent
ELENESSA and GPS-3 fault table A8
TSD-PAD failure
A9
weighing device transmission error
AA
weighing device temperature is abnormal
B1
can't be used for 10 minutes.
B2
cannot be used for 16 minutes
B3
can't start for another 10 minutes
B4
can't run for 10 minutes
B5
can't open the door for 2 minutes
B6
fuse failure 2 minutes
B7
#60 failure
B8
can't open the door
B9
control box failure
BA
door sensor ON failure
BB
off warning
BC
use can not be warned
BD
group control failure
BE
power failure (stations)
BF
door sensor OFF failure
C1
SLC transmission failure
C2
SLC E-stop
C3
SLC abnormal high speed
C4
SLC reverse timer
C5
Open Door Run out (SLC) C6 SLC RAM Fault
D1
Front door BC-CPU1 error
D2
Front door BC-CPU2 error
D3
Front door BC-CPU3 error
D4
Front door BC-CPU4 error
D5
Front door CS-CPU error
D6
Front door DC-CPU error
D7
Front door IC-CPU error
D8
Front door CZ-CPU error
D9
SC -CPU exception
DA
SH-CPU exception
DB
SC-CPU exception
DC
SH-CPU exception
DD
HS-CPU exception
E1
Back door BK-CPU5 error
E2
Back door BC-CPU6 error
E3
Back door BC-CPU7 error
E4
Back door BC-CPU8 error
E5
Back door CS-CPU error
E6
Back door DC-CPU error
E7
Back door IC-CPU error