Error Mitsubishi

ELENESSA and GPS-3 fault table E1 SWTGBL abnormally low speed E2 SWTGBH abnormal high speed E3 SWTGBR Reverse-ru

Views 331 Downloads 15 File size 70KB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

Citation preview

ELENESSA and GPS-3 fault table E1

SWTGBL

abnormally low speed

E2

SWTGBH

abnormal high speed

E3

SWTGBR

Reverse-run detection

E4

SWAST

E5

SSIOCFO (IOCH)

overcurrent (transformer, E1, module)

E6

SSCOVH

overvoltage (inductance, lack of phase)

E7

SSLVLT

undervoltage (temperature insurance, E1, regeneration)

E8

SWCFLB

#LB OFF failure

E9

SWCF5

#5 OFF fault

EA

SWCFBK

brake contactor ON/OFF failure

EB

STSTSCE

car serial failure

EC

STSTSHE

landing station serial failure

Anti-stole timer

ED

STSYER

system failure (P1 setting)

EE

SDDNRS

can no longer be started (drive)

EF

SWNRS

can no longer be started (control)

Machine room 01

INV temperature detection

02

E-STOP once

03

CC-WDT 3 times

04

SLC-WDT 3 times

05

motor over current

06

brake resistor overload

07

41 contactor failure

08

Terminal deceleration switch failure

09

level switch failure

0A

weighing device failure

0B

E1 board failure

0C

UHS/DHS switch failure 0D DZ detection loop failure

0F

LB failure

11

remote reset / test

12

layer selector error 16 times

13

serial failure

14

Capacitor capacity is insufficient

15

manual run button\fault

16

speed graphics jump 5 times

17

#LB action failed 5 times

18

#5 action failed 5 times

19

#BK1 action failed 5 times

1A

#BK2 action failed 5 times

1B

LVLT 5 times

1C

E1 board failure

1D

fan failure

1E

Fan or E1 board failure

1F

Fan or E1 board failure

21

#5 ON failure

22

E-STOP twice

23

system failure

ELENESSA and GPS-3 fault table 24

reset request

25

PCB base drive failure

26

DC-CT failure

28

immersion sensor failure

29

Anti-immersion action ends

2A

#PWD shutdown command lasts 3 minutes

2B

handrail switch remains

2C

brake drag operation ends

2D

brake re-action failure

2F

selector is faulty 16 times

31

MELD overload

32

abnormally low speed

33

abnormal high speed

34

Reverse timing (motor running time limit)

35

reverse operation

36

reverse timer

37

reverse timer

38

inverter overvoltage

39

Inverter undervoltage

3A

CC-WDT 4 times

3B

SLC-WDT 4 times

3C

inverter over current

3D

SLC E-stop

3E

encoder failure (automatic)

3F

encoder failure (manual)

41

two E-STOP

42

INV undervoltage

43

E-stop F/F reset

44

#LB coil failure

45

#5 coil failure

46

#BK1 coil failure

47

#BK2 coil failure

48

Power on

4B

inverter charging failed

51

electrical safety circuit

52

#29 latch (may be R1 board bad 5# sparker bad)

53

Power failure (DC power failure)

54

INV undervoltage

55

12V power failure

56

control screen open

57

manual overload operation

58

drive S/W E-stop

59

Management S/W E-stop (Z1 board is broken)

5B

abnormal brake sliding distance

61

Inverter undervoltage

62

PCB base drive failure

63

INV protection circuit action

64

#29 latch

65

12V power failure

ELENESSA and GPS-3 fault table 66

temperature switch exceeds 75 degrees

67

temperature switch over 90 degrees

68

temperature switch cooling / connector disconnection

69

inverter over current

6A

inverter overvoltage

6B

power off (DC power failure)

6C

E1 board warning

6D

DC power failure

6E

AC power failure

6F

#PWD (power failure detection)

71

CC-WDT 5 times

72

CC-WDT 4 times

73

CC-WDT 3 times

74

SLC-WDT 5 times

75

SLC-WDT 4 times

76

SLC-WDT 3 times

7C

weighing plate is less than 30 degrees

7D

weighing plate 30-40 degrees

7E

weighing plate over 60 degrees

7F

weighing device A/D conversion

81

#BK1 over current

82

#BK2 over current

83

#BK1 DC-CT disconnection

84

#BK2 DC-CT disconnection

85

#BK1 Coil failure

86

#BK2 Coil failure

87

#BK1 coil short circuit

88

#BK2 Coil short circuit

89

#BK1 DC-CT failure

8A

#BK2 DC-CT failure

8B

#BK1 coil is shorted

91

drive E-stop

92

motor over current

93

can no longer be started (drive S/W)

94

MELD overload operation

95

TSD switch failure

96

Weighing device failure

97

DC-CT failure

98

TSD operation

99

encoder Z phase failure

9A

encoder F phase failure

9B

with timer motor over current detection

9E

door cut-off circuit failure

A1

graphics - speed jump

A2

speed graphics jump exception

A3

driver S/W E-stop

A4

regenerative resistor overload

A6

manual overload operation

A7

MCP inverter overcurrent

ELENESSA and GPS-3 fault table A8

TSD-PAD failure

A9

weighing device transmission error

AA

weighing device temperature is abnormal

B1

can't be used for 10 minutes.

B2

cannot be used for 16 minutes

B3

can't start for another 10 minutes

B4

can't run for 10 minutes

B5

can't open the door for 2 minutes

B6

fuse failure 2 minutes

B7

#60 failure

B8

can't open the door

B9

control box failure

BA

door sensor ON failure

BB

off warning

BC

use can not be warned

BD

group control failure

BE

power failure (stations)

BF

door sensor OFF failure

C1

SLC transmission failure

C2

SLC E-stop

C3

SLC abnormal high speed

C4

SLC reverse timer

C5

Open Door Run out (SLC) C6 SLC RAM Fault

D1

Front door BC-CPU1 error

D2

Front door BC-CPU2 error

D3

Front door BC-CPU3 error

D4

Front door BC-CPU4 error

D5

Front door CS-CPU error

D6

Front door DC-CPU error

D7

Front door IC-CPU error

D8

Front door CZ-CPU error

D9

SC -CPU exception

DA

SH-CPU exception

DB

SC-CPU exception

DC

SH-CPU exception

DD

HS-CPU exception

E1

Back door BK-CPU5 error

E2

Back door BC-CPU6 error

E3

Back door BC-CPU7 error

E4

Back door BC-CPU8 error

E5

Back door CS-CPU error

E6

Back door DC-CPU error

E7

Back door IC-CPU error