PSVDescripción completa
Views 239 Downloads 0 File size 33KB
Pressure Relief Valve UNITS: Flow -> Liquid - M3/hr Gas - Nm3/hr Steam - Kg/hr Pressure -> Kg/cm²G Temperature-> °F Level /length -> mm General
Valve
1
Tag Number
PSV-503
2
Inlet Line Number
2"-RP-10-2504-B1A
Outlet Line Number
3"-RP-10-1108-B1A
3
Vessel Protected
-
4
Safety / Relief
Relief
5
Type :
Spring Loaded
6
Full Nozzle Full Lift ¦ Mod. Nozzle
Full Nozzle Full Lift
7
Bonnet Type
Closed
8
Conv. / Bellows / Pilot Operated
Bellow
9
Inlet Connection: Size & Rating
11
Outlet Connection: Size &Rating
3" x 150# : Facing & Finish RF 125-250 AARH
12 13
2" x 300# : Facing & Finish RF 125-250 AARH
10
Cap Over Adjusting Bolt:
Required Screwed ¦ Bolted Bolted
14 15
Lifting Gear- Type
Yes
16
Test Gag
Yes
18
Body and Bonnet
A216 Gr. WCB
19
Nozzle and Disc
SS 316
20
Spring
CS-Zinc Plated
21
Bellows
SS 316L
Guide & Ring
SS 316
17 Material
22 23
Options
Basis
Service Conditions
24
Resilient Seat Seal
25
Radiography
Yes,
26
Special Requiment
PMI for Wetted parts, Helium
27
Code
API-520/526
28
Basis of Selection
Blocked Discharge
30
Fluid and State
Propane
31
Corrosive Costituent
32
Required Flow Capacity
13170.9 kg/hr
33
Mol. Wt.¦Sp.Gr. at Relieving Temp.
44.07
34
Operating Pressure (Inlet / Outlet)
14.95 Kg/Cm2 g
35
Operating Temp.¦Relieving Temp.
49.24 0C
36
Valve discharges to
Flare
37
Back Press. ¦ Constant / Variable
1.70 Kg/Cm2 g
38
Set Pressure
17.0 Kg/Cm2 g
39
Cold Bench Test Pressure
17.3 Kg/Cm2 g
40
% Over Pressure ¦ % Blowdown
10%
41
Cp/Cv ¦ Compressibility Factor
1.1763
42
Viscosity at Rel. Temp. mPas(cP)
N.A
43
Vessel:Wall temp°C¦Surf.Area-m2
N.A
45
Calculated Area - cm2
7.475 Cm2
46
Sel. Area - cm2
8.303 Cm2
47
No. of valve required for capacity
1
48
Total area - cm2
8.303 Cm2
49
Actual Flow Capacity
14629.98 Kg/hr
/
|
Gas
-
|
|
177 0C
| Variable
5-7% |
0.7266
44 Orifice
50
¦ Orifice Design
|
J
Nos.
51
Model No.
6636-2-C-2".J.3"-A-P-F-V
52
MAKE :
MEKASTER ENGG. LTD
53
IBR Certification
DEVIATION
N.A
VENDOR DRAWING NO-6972-010-50-45B-1-1017
ORDER NO:-
FILE-
REQUISITION NP :
_
fgngl
N.A
NO DEVIATION
ENGINEERS INDIA LIMITED
CLIENT
SEL/ONGC/LO/10-11/146 DTD 14-11-2010
:
SAVAIR ENERGY LIMITED
PLANT : KOCHI REF.
NEW DELHI
VENDOR
N.A
VENDORS' SIGNATURES WITH SEAL
NEW PROPANE GAS COMP. :
DRESSER RAND INDIA PVT LTD
23/2/2011
YASH
DATE
BY
DATA SHEET NO. 6972-010-50-45B-1-1017
This drawing and the design it covers are the properties of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will not be reproduced, copied, loaned, exhibited, nor used except in the limited way and private use permitted by any written consent given by lender to the borrower
N.A
YASH
BNS
CHKD
APPD
A SHEET NO.
REV
10-50-45B-1-1017
0