Telemetry Modules Quick Start

Inventia sp. z o.o. All rights reserved

Necessary Software

 

  

Microsoft Framework 1.1 MTManager MTDataProvider v2.4 ModDog Softing OPC or other OPC client

All programs install with default settings

Inventia sp. z o.o. All rights reserved

Configuring MT-102 with MTM

1.

Run MTM From icon

2.

Enter project name 2.

3. Add new module by Right click on project name

Inventia sp. z o.o. All rights reserved

Configuring MT-102 with MTM

4.

Enter module name and chose type and firmware

Tips: If you don’t know what version of firmware you have, chose deafault. In download moment if type is different MTM tell you. Then use “change version” from right click menu

Inventia sp. z o.o. All rights reserved

Configuring MT-102 with MTM

5.

Click “General” in “Device” list Enter PIN number card that you plan to use in “SIM card PIN number field” Make sure option “YES” is in “Use of GPRS”

Inventia sp. z o.o. All rights reserved

Configuring MT-102 with MTM

6.

Click “GPRS” in “Device” list Enter your APN name, user, password if required

Inventia sp. z o.o. All rights reserved

Configuring MT-102 with MTM

7.

Expand “Authorized numbers” in “Device” list and click “IP” field Enter IP number of SIM card that will be use in Module near the PC

Inventia sp. z o.o. All rights reserved

Configuring MT-102 with MTM

8.

Click “resources” in “Device” list and check “Internal resources Modbus ID number” Default is 1, here you can change ID for MT module

Inventia sp. z o.o. All rights reserved

Configuring MT-102 with MTM

9. Connect MT-102 to PC using RS cable

10. Click “Environment” and use your COM port

11.

Apply by clicking “Write” Inventia sp. z o.o. All rights reserved

Configuring MT-102 with MTM

12. Click “Write” and watch the progress bar

11. Click „Connect”

Watch the LED OVR on the module Until is lighting do not power off. After the LED turn off, power off the module and put the SIM card inside. Then power on.

Accept by click OK Inventia sp. z o.o. All rights reserved

Configuring MT-202 with MTM

13. Add new module MT-202

14. Enter Pin in „General”, APN in „GPRS”

Inventia sp. z o.o. All rights reserved

Configuring MT-201 with MTM

15. Change „Module operating mode” to Modem in General

16. Chose„Transmision speed” in Resources/Serial port connect MT-201 and „Write” the configuration Inventia sp. z o.o. All rights reserved

Add hardware in Windows Control Panel

17. In Control Panel click „Add Hardware”

18. Add modem just like on the screens in the right

Inventia sp. z o.o. All rights reserved

Dial-up configuration in Windows Control Panel

19. In Control Panel click „Network Connection” And create a new connection in network tasks

20. Add connection just like on the screens on the right

Enter Entername accesofnumber connection Enter user name and passwordIf neccesary

Inventia sp. z o.o. All rights reserved

Dial-up configuration in Windows Control Panel

Tips: If the dial-up connection have failed, you can make handshake on the COM port from PC side:

21. Connect MT-202 to PC using port 2

22. Click on APN icon

23. Click Properties Inventia sp. z o.o. All rights reserved

Dial-up configuration in Windows Control Panel

24. In the bookmark Options change „Redialin options”

25. In the bookmark Networking Chose TCP/IP protocol and Click Properties button

26. Click „Advanced” button

27. Uncheck „use default gateway…” checkbox After that click 3 times „OK.” and DIAL then you will see: Inventia sp. z o.o. All rights reserved

MT- Data Provider – first steps In that area configure what can reading writing After First Next steps move installation is isyou changing enter go IP to numbers destination default sample.xml ofyou directory: SIM card file. that ”C:\Program You isormount must enter Files\ABinfrom/to theIP 27. 24. 25. 26. 28. Here you should to put correct type of the module remote MT-201 module. Default ID modbus is „1” in just like in MTM. MICRO\MTopc2\” numbers module of remote and module open „sample.xml” NOTEPAD

Tips More info about XML parameters in readme.pdf in install folder of MT-Data Provider.

29. Now you can save and close sample.xml Inventia sp. z o.o. All rights reserved

MT- Data Provider – first steps 30. From Start/All programs/Softing OPC toolbox… run Softing OPC.

Click click onClick the od DA Browse bookmarks bookmark right click on server ID 31. Left 32. 33. Double on items MT-OPC server willand start driver And left click on „Add Item for all tags” Inventia sp. z o.o. All rights reserved

MT- Data Provider – first steps

Here you will see quality good for all configured tags in sample.xml 34 For exaple „device—slave.BO0” is the binary output Q1 Enter 1 in this field and click write send this to remote module

Inventia sp. z o.o. All rights reserved

Congratulations!!!

You have configured your first telemetry system based on module MT-102 produced by InVentia !!!

If you have questions please contact Technical Support: +48 22 54 53 230