Itp Electric Motors

KBR INSPECTION TEST PLAN FOR ELECTRIC MOTORS (500 HP and LARGER) NO. INSPECTION ACTIVITY Level 1 Level 2 Level 3 Select

Views 58 Downloads 0 File size 115KB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

  • Author / Uploaded
  • kaml
Citation preview

KBR INSPECTION TEST PLAN FOR ELECTRIC MOTORS (500 HP and LARGER) NO.

INSPECTION ACTIVITY Level 1 Level 2 Level 3 Selected Level of Inspection >

1

PRE-INSPECTION MEETING

H

H

2

DOCUMENTATION REVIEW Vendor Quality Plan Manufacturing Schedule Material Substitution Request Testing Procedures Manufacturer's Data Report

R R R R R

R R R R R

SW W R W SW R W

N/A W R SW SW R W

TESTING Winding Resistance No Load Run Full Load Run Torque Test Locked Rotor Test Insulation Resistance Test Dielectric Test Vibration Check Noise Test Certified Copies of Test Data

W W W W W W W W W R

SW SW SW SW SW SW SW SW SW R

5

FINAL VISUAL & DIMENSIONAL INSPECTION (100%)

H

H

6

PAINTING & SHIPPING Painting & Perservation Shipping Preparation

H W

H W

NAMEPLATE REVIEW

H

H

3

4

7

MANUFACTURING (In Process) Visual Inspection of Rotor & Fields Before Assembly Terminal Boxes Space Heaters Cooling Fans Bearings & Shaft Insulation System Baseplate & Soleplates

Note:

H = Hold Point W = Witness Point SW = Spot Witness R = Review N/A = Not Applicable

KBR INSPECTION TEST PLAN FOR ELECTRIC MOTORS (500 HP and LARGER)

NO. 8

INSPECTION ACTIVITY Level 1 Level 2 Level 3 Selected Level of Inspection > COMMENTS If a discrepancy exists between this document and the applicable Engineering data sheets, the information listed on the data sheets shall take precedent. Unless specified otherwise by the purchase order, inspection will only be conducted for motors of 500 HP and larger. However, inspection will be conducted for all motors, regardless of size, that ship directly to the jobsite.

Note:

H = Hold Point W = Witness Point SW = Spot Witness R = Review N/A = Not Applicable

KBR INSPECTION TEST PLAN FOR ELECTRIC MOTORS (500 HP and LARGER) Level 4

N/A

R R R R R

N/A N/A R N/A N/A N/A W

SW/R SW/R SW/R SW/R SW/R SW/R SW/R SW/R SW/R R H

H W H

Note:

H = Hold Point W = Witness Point SW = Spot Witness R = Review N/A = Not Applicable

KBR INSPECTION TEST PLAN FOR ELECTRIC MOTORS (500 HP and LARGER)

Level 4

Note:

H = Hold Point W = Witness Point SW = Spot Witness R = Review N/A = Not Applicable