ZTE SDR Alarms on ZONG Project SDR Alarms Types Phase I Indoor site (GSU) Phase l Outdoor site Phase I Outdoor Sol
Views 96 Downloads 0 File size 502KB
ZTE SDR Alarms on ZONG Project
SDR Alarms Types Phase I Indoor site (GSU) Phase l Outdoor site Phase I Outdoor Solar site (GSU) Phase 0 Indoor site (GSUR) Phase II site (MISU)
Phase I Indoor
Phase I Indoor site Alarms detail
Precautions during SDR swap Conform sensors to BTS connections Than conform with OMCR how many alarms are working on BTS After that cut alarm cable from BTS end BTS alarm cable connect with SDR alarm cable following color scheme Than alarm test on SDR
SDR to BTS color scheme
Phase I Outdoor site
Phase I Outdoor site Alarms detail
Precautions during SDR swap
Conform sensors to BTS connections Than conform with OMCR how many alarms are working on BTS BTS alarm cable and SDR alarm cable color scheme is same Sensors alarm cable direct connect with SDR alarm cable same like BTS alarm cable Than alarm test on SDR
Outdoor Solar site
Phase I Outdoor Solar site Solar site alarm template is change to other sites Solar site have seven alarm All sensors are connect with GSU GSU out put connect with BTS or SDR Outdoor BTS and SDR alarm cable color combination are same
Outdoor SDR solar site Alarm detail and connection
Precautions during SDR swap Conform GSU output to BTS connections Than conform with OMCR how many alarms are working on BTS BTS alarm cable and SDR alarm cable color scheme is same GSU output cables connect with SDR alarm cable same like BTS alarm cable Than alarm test on SDR
Phase 0 Indoor sites
Phase 0 Indoor site Phase 0 site alarm template is same like Phase I sites BTS alarm cable color combination not same with Phase I cable All sensors are connect with GSUR GSUR out put connect with BTS or SDR
Phase 0 Indoor site Alarms detail
Precautions during SDR swap
Conform sensors to BTS connections Than conform with OMCR how many alarms are working on BTS After that cut alarm cable from BTS end BTS alarm cable connect with SDR alarm cable following color scheme Than alarm test on SDR
SDR to BTS color scheme
Phase II (MISU)
Precautions during SDR swap First conform with OMCR how many alarms are working MISU Conform MISU E1 connect with BTS PCM number After swap conform SDR PCM number and connect with MISU Than alarm test on SDR
MISU E1 connection with SDR SDR E1 cable Color Orange Double Dot red
MISU E1Converter cable color White -Green
Orange Double Dot Black
Blue
Gray Double Dot red
White-Orange
Gray Double Dot Black
Orange