Waukesha gas engines VHP P9390GL

GE Power & Water Waukesha* gas engines VHP * P9390GL 1320 - 1980 BHP (984 - 1476 kWb) VHP engines have been powerin

Views 150 Downloads 2 File size 73KB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

Citation preview

GE Power & Water

Waukesha* gas engines

VHP

*

P9390GL 1320 - 1980 BHP (984 - 1476 kWb)

VHP engines have been powering the world’s energy infrastructure―driving compressors in gas gathering, processing and transmission operations and providing electrical power for oil and gas fields in remote corners of the globe for over five decades.

Backed by more than a century of engine building experience, GE’s Waukesha engines are a sound investment that offer durable designs that perform reliably in remote applications and tolerance for variable fuel quality that maximizes power output, uptime and profitability.

technical data Cylinders Piston displacement Compression ratio Bore & stroke

V16 9388 cu. in. (154 L) 10.5:1 9.375’’ x 8.5’’ (238 mm x 216 mm)

Jacket water system capacity

148 gal. (560 L)

Lube oil capacity

165 gal. (625 L)

Starting system

Dimensions l x w x h inch (mm) 184.09 (4676) x 77.86 (1978) x 112.00 (2845)

Weights lb (kg) 28,750 (13041)

125 - 150 psi air/gas 24V electric

*Trademark of General Electric Company

performance data Intercooler Water Temperature 130°F (54°C)

1200 RPM

1000 RPM

Power bhp (kWb)

1980 (1476)

1650 (1230)

BSFC (LHV) Btu/bhp-hr (kJ/kWh)

7198 (10184)

7079 (10017)

Fuel Consumption Btu/hr x 1000 (kW)

14253 (4176)

11680 (3423)

NOx g/bhp-hr (mg/Nm @ 5% O2)

1.50 (607)

1.50 (607)

CO g/bhp-hr (mg/Nm3 @ 5% O2)

2.70 (1073)

2.70 (1073)

NMHC g/bhp-hr (mg/Nm @ 5% 02)

1.00 (405)

1.00 (405)

THC g/bhp-hr (mg/Nm3 @ 5% O2)

5.50 (2227)

5.50 (2227)

Emissions

3

3

Intake/ Exhaust System

Heat Balance

Heat to Jacket Water Btu/hr x 1000 (kW)

3463 (1015)

3126 (916)

Heat to Lube Oil Btu/hr x 1000 (kW)

623 (183)

520 (152)

Heat to Intercooler Btu/hr x 1000 (kW)

770 (226)

633 (186)

Heat to Radiation Btu/hr x 1000 (kW)

395 (116)

346 (101)

Total Exhaust Heat Btu/hr x 1000 (kW)

4237 (1242)

3082 (903)

Induction Air Flow scfm (Nm3/hr)

4890 (7516)

4008 (6160)

21220 (9625)

17390 (7888)

762 (406)

675 (357)

Exhaust Flow lb/hr (kg/hr) Exhaust Temperature °F (°C)

All data according to full load and subject to technical development and modification. Consult your local GE Power & Water’s representative for system application assistance. The manufacturer reserves the right to change or modify without notice, the design or equipment specifications as herein set forth without incurring any obligation either with respect to equipment previously sold or in the process of construction except where otherwise specifically guaranteed by the manufacturer.

GE Power & Water 1101 West Saint Paul Ave. Waukesha, WI 53188-4999 P: 1.262.547.3311 F: 1.262.549.2759