4522_981_91321.qxd 8/4/04 2:51 PM Practix 300 Page 6 Specifications Practix – Mobile Radiography Changing its po
Views 29 Downloads 1 File size 127KB
4522_981_91321.qxd
8/4/04
2:51 PM
Practix 300
Page 6
Specifications
Practix –
Mobile Radiography
Changing its point of view comes naturally Practix 300 With its swiveling telescopic tube arm and rotatable column, the Practix 300 adds a new and outstanding dimension to mobility. Optimal positioning can be achieved as easily as with a stationary Bucky system. Various features and options allow the unit to be used for wide ranging applications in all fields of radiography.
4522_981_91321.qxd
8/4/04
2:51 PM
Page 1
Mobility from
head to toe Easy handling and positioning The easy maneuverability of the Practix 300 allows X-ray exposures to be made wherever needed. With its smooth running wheel system and small footprint, Practix 300 provides outstanding mobility. The Practix 300’s swiveling telescopic tube arm and rotatable column allow the tube to be positioned quickly and easily, whether the unit is situated at the foot or the side of the bed.
Due to its geometry with rotatable column and swiveling telescopic tube arm, both beds are easily accessible without the need to reposition the basic system.
Applications Short exposure times prevent motion artifacts, with high peak power and mAs producing images of excellent quality. This allows the Practix 300 to be used for a wide range of applications and is particularly suitable for taking X-rays of patients in emergency rooms and for use with thorax exposures. 36 APR programs make working easier and faster. Additionally available options are remote control, high-resolution X-ray tubes with different focal spots and dose area product measurement (Diamentor PX). Digitalization As with all members of the Practix family, the Practix 300 can be upgraded to digital by adding CR (Computed Radiography) cassettes, providing a lighter and more compact alternative to a digital flat detector.
4522_981_91321.qxd
8/4/04
2:51 PM
Page 2
Technology you can rely on
Basic unit Type
Mobile X-ray unit with rotating column (±200°) and telescopic X-ray tube arm
Dimensions in mm (l x w x h)
1120 x 617 x 1925 (44.13" x 24.31" x 75.84")
Cassette storage
Radiation protected for up to 10 cassettes (43 cm x 43 cm)
Source-floor distance
70 cm to 200 cm
Weight
290 kg (639 lbs)
Generator Type
High-power X-ray generator
Peak power
30 kW (100 kV / 20 ms) at 230 V / 115 V (mains voltage)
Nominal power
22 kW (100 kV / 100 ms) at 230 V / 115 V (mains voltage)
Tube voltage
40 kV to 125 kV in 1 kV steps
Maximum current
300 mA
Tube current time product: – large focal spot
0.1 mAs to 200 mAs
– small focal spot
0.1 mAs to 64 mAs
Mains supply
115 V ±10%, 230 V ±10%, single-phase, 50 Hz (60 Hz)
Mains fuse
16 A slow
Preparation time
≤1s
Exposure times
1 ms to 5.3 s
X-ray tube Type
Rotating-anode X-ray tube
Anode material
Rhodium,Tungsten, Molybdenum
Nominal focal spot
0,6 / 1,5 or 0,6 / 1,2 (option)
Anode angle
14°
Maximum radiation field
43 cm x 43 cm
Options Dose area product measurement (Diamentor PX) Remote control Pediatric filters
4522_981_91321.qxd
8/4/04
The
2:51 PM
Page 3
dimensions of maneuverability
2000 880 730
1120
95
10°
1000
1925
°
700
0° 36
All dimensions in mm
617
2000
380
360°
820 1180
On release of break lever, unit stops immediately
Radiation protected cassette drawer for up to ten cassettes
User interface for full system control including all options
4522_981_91321.qxd
8/4/04
2:51 PM
Page 4
Even within reach from the bed’s foot end
Lateral exposure in emergency environments
Digitalization via Philips Computed Radiography
4522_981_91321.qxd
8/4/04
2:51 PM
Page 5
Philips Medical Systems is part of Royal Philips Electronics Interested?
Asia Tel: +852 2821 5888 Europe, Middle East, Africa Tel: +31 40 27 63005
Would you like to know more about our imaginative products? Please do not hesitate to contact us. We would be glad to hear from you.
Latin America Tel: +55 11 2125 0764
On the web
North America Tel: +1 425 487 7000
www.medical.philips.com
Via e-mail [email protected]
By fax +31 40 27 64 887
By postal service Philips Medical Systems Global Information Center I.B.R.S./C.C.R.I. Numéro 11088 5600 VC Eindhoven Pays-Bas/The Netherlands
(no stamp required)
© Koninklijke Philips Electronics N.V. 2004 All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright holder. Philips Medical Systems DMC GmbH reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Printed in The Netherlands. 4522 981 91321/704 * JUL 2004