CENTRO.MATIC@ The memory feature will work as follows: Dioswitch set to "Memory Off'- Will result in a lube cycle each time power is turned on. Lube cycle will start at the beglnning of the on time setting.
Safety Read and carefully observe these operating instructions before unpacking and operating the controller! The controller must be operated, maintained and repaired exclusively by persons familiar with the operating instructions. Local safety regulations regarding installation, operation and maintenance must be followed. Operate this controller only after safety instructions and this service manual are fully understood.
$,
wnnNrNG
This symbol identifies the potential for a
hazardous srtua'tion.
Dipswitch set to "Memory On" 1 . Power is turned off during the off time (time between lube cycles). When turning power back on will cause the lube cycle to continue from the point of interruption. 2. Power is turned ofi during the on time or pumplng time. Turning power back on will cause the lube cycle to start at the beginning of the on tlme setting.
Timer Mode When the dipswitch is set to the timer mode, amount of time that the pump is on will be determined by the setting of the dipswitch. Time will be either 30 seconds or 2 minutes.
Controller Mode When the dipswitch is set to the controller mode, a pressure switch must be installed in the lube supply line. This will provide pressure-monitoring capabilities. The pressure switch will reset the controller when the Bet pr6ssure is detected. The controller will initiate an alarm whsn the pump fails to develop sufficient pressure to actuate the pressure switch within the dipswitch setting of 30 seconds or 2 minutes.
lf this warning is not followed, a serious could occur.
Description General Description
Controller Operation The time between lube events is determined by the setting of the rotary switch, which selects the numeral setting, and the dipswitch, which selects the units in either minutes or hours. When used in the timer mode, the pump will remain on for the amount of time that was selected by the dipswitch. Time will be either 30 seconds or 2 minutes (see Timer Mode). When used in the controller mode, the amount of time that the pump is on is determined by the closing of a pressure switch in the lube supply line (see Controller Mode). Failure of the pressure switch to close within the time setting of the dipswitch, either 30 seconds or 2 minutes, will result in an alarm condition. The alarm LED will turn on and the alarm contact will close. The controller will continue to initiate lube cycles while in alarm. When the low-level switch closes, the alarm LED will turn on and the alarm contact will close. The controller will continue to initate lube cycles while in alarm- Alarm condition will remain until low-level switch opens. Pressing the manual lube button on the enclosure cover will always initiate a lube event.
Model 85535 controller is used to program the cycle frequency of a lubrication pump. Lube cycles are determined by the setting of internal switches. The cycles times are selected to meet system requirements. During the "ON" time, the air to the pump solenoid will be energized.
Appropriate Use
. . .
Model 85535 is exclusively designed for use in a Centralized Lubrication System. The maximum ratings given should not be exceeded. Any other use not in accordance with the instructions will result in loss of claim for warranty and liability.
Product Specification Input Voltage: Current Consumption: Load Relay Contact: Alarm Relay Contact: Enclosure: Temperature Range: Net Weight: Off Time (adjustable): On
Time:
Lubrication
Page Number - 2
System:
:
21VDC to 30 VDC 100 MA (less external load) 2 amps inductive load at 30 VDC
2 amps inductive load at 30 VDC NEMA 12 -40' F to 'l 50' F (-40' C to 65' C) 4 lbs. 30 seconds minimum 30 hours maximum 30 seconds minimum 2 minutes maximum Centro Matic
Form 404005
CENTRO.MATIC@ Field Gonnections Terminal Strio 1 throuqh 8
Terminal Strio 1 through 4
Terminal Terminal
1 2
Bat + Bat -
Terminal
Terminal 2
Low level switch (closes to indicate an alarm)
Terminal Terminal
3 4
24 VDC source for external air to pump solenoid.
Terminal 3 Terminal 4
System pressure switch (closes to end lube cycle). Only used in the Controller Mode.
Terminal Terminal
5 6
Dry alarm contact (contact closes on fault)
Terminal Strip AB
1
Terminal A Terminal B
Remote Normally Open Manual Lube Switch
Observe correct polarity for Terminals 1,2,3 and 4.
24
VDC
6
..- +J \Ure - -
.o\,
o-1 I
PRESSURE SW I TCH
2
I
I
L-
-I I
-o
o-
MANUAL LUBE SWI TCH
SYSTEM COMPONENTS Qtv.
otlJJO
1
68552 350283
L
lllustration
Part No.
,l 1
Descriotion Fu se Holder 7.5 Am p Fuse 24 VDC Solenoid
1@
Wiring Diagram 1. Incoming Power: 24VDC.
2.24VDC Air Solenoid Valve. 3. Optional Alarm wired by customer.
4. Keypad with indicator lights and manual lube push button. 5. Optional Low Level Switch wired by customer.
6. Pressure Switch wired by customer- Not needed if used in the timer mode. @ 7. Remote Manual Lube Switch. @ Indicates change
Form 404005
Page Number - 3
CENTRO.MATIC@ Gontroller Gomponents and Setting the Controller Mode Swltch ldentlflcation 30 seconds or 2 mlnutes
-
-
Timer or Gontroller Hours or Minutes
.
Memory Off or Memory On
-
See lllustratlon 2 Select the maximum amount of "On'l'ime". Select llmer Mode or Controller Mode. Select units for the "Off Time" used with the Rotary Switch. Select memory feature.
Off Time Switch - See lllustration 2 Using the Rotary Switch you can select .5, 1,2, 4,8, 15,24 or 30. The units are either minutes or hours as determined by the mode switch setting.
Enclosure Cover - See lllustration 2 Green LED Indicates that power is applied to the
Green LED Red LED Manual Lube
-
controller. Indicates that the pump is on. Indicates an alarm condition, Pressing will initiate a lube cycle.
Repair Parts List Item
Quan.
1
1
,
1
Descriotion
Part Number
Timer Board Kcvnad Acs'rr
250599 249695
O POWER
O PUMP ON O ALARM
CONTROL SWTCH OFF
.0.=".
SWTCH ON
lE
tro.=".
TIMER IEEICONTROLLE
HOURS MEI\4ORY
fr4vpc I uorr.l--1".^r, lTlu^ | ^ l:m:ruu ,,',1-J6-l ,^*FlMgL:;
IEIMINUTES
13
MEMoRY oN
MODE SWITCH
One Lin@ln Way,
g
Louis. MO 63120-1576
WA R N I N G ELECTRICAL SHOCK HAZARD TURN OFF AND LOCK OUT POWER BEFORE OPENING ENCLOSURE
lllustration
2
@ Indicates change
Page Number - 4
Form 404005
CENTRO.MATIC@
IJDTCOLN l--
,
'll2" (8e mm)
5/16'(8 mm Dia. Mtg. Holes) (4 places)
7 - 1t2"
(191 mm) 6 - 314" (171 mm)
Conduit Hole
2"
(51 mm) 4 - 15116" (125 mm)
Dimensions @
Indicates change
Form 404005
Page Number - 5
GENTRO.MATIC@ Lube
without Alarm Mon
rossible Gause {o electric power to controller.
]ondltion )ontroller does not ooerate.
)orrective Action 'urn on electric power to pump. "Powe/' L.E.D. ;hould light, 'PUMP ON' L.E.D. should light when
MANUAL LUBE" is pressed.
)rinted circuit board failure.
lemove and replace.
-oad connected to terminals 3 & 4
)rinted circuit board failure or
lemove and replace.
:nergized, but "PUMP ON" L.E.D.
ieypad failure.
PUMP ON' L.E.D. lights, but load >onnected to terminals 3 & 4 will rot energize.
loes not light. 3earing points are over lubricated.
fimer/Controller memory mode
furn on memory mode of timer/controller.
s set to off.
njector output adjustment setting
teadjust to lower setting.
oo hiqh. Seadng points are under
l'imer/Controller cycle time
iet to longer cycle time or reevaluate lube
ubricated.
;etting too low.
equirements.
njector output adjustment setting
ieadjust to right setting.
oo tow. fimer/Controller cycle timer
iet to shorter cycle time or reevaluate lube
;etting does not deliver lubricant
equirements.
lften enouqh. iystem too large for pump output.
lalculate system requirements per planning nanual.
Additional lome, but not all, of the injectors lre delivering lubricant. There is
is used
when Alarm
fimer/Controller is set to "Time/'. )ressure switch setting is too low.
iet Timer/Controller to "Controller Mode. \djust pressure setting to setting high enough for rll injectors to cycle.
ro alarm condition. Lube Alarm" L.E.D. turns and
lad electrical connection
itays on.
)ressure Switch and Timer/
between
lheck all wiring between Pressure Switch and fimer/Controller.
lontroller. )ressure switch setting is too
\djust pressure switch to setting high enough for
rish.
rll injectors to cycle.
rressure Switch is defective )rinted circuit board is defective.
lepair or replace.
-ow level switch wired incorrectlv
lheck low level switch wiring and correct if
leplace printed circuit board.
lecessary. Contact closure must be on low level ;ondition. -ow system air pressure
ncrease arr pressure.
Americas:
Europe/Africa:
Asia/Pacific:
One Lincoln Way St. Louis, MO 63120-'1578 USA Phone +1 .314.6794200 Fax +1.800.424.5359
Heinrich-Hertz-Slr 2-8 D-69183 Walldorf Germany Phone +49.6227.33.0 Fax +49.6227.33.259
51 Changi Business Park Central 2 #09-06 The Signature Singapore 486066 Phone +65.6588.0188 Fax +65 6588.3438
Page Number -
G
O Copyright 2006 Printed in USA Web site: www.lincolnindustrial.com
Form 404005