MO Parameter Name RRCCONNSTATETIMER Ue inactive timer RRCCONNSTATETIMER UE Inactivity Timer Dynamic DRX RRCCONNSTA
Views 246 Downloads 0 File size 42KB
MO
Parameter Name
RRCCONNSTATETIMER
Ue inactive timer
RRCCONNSTATETIMER
UE Inactivity Timer Dynamic DRX
RRCCONNSTATETIMER
NB-IoT Ue inactive timer
RRCCONNSTATETIMER
Ue Inactive Timer for Qci1
RRCCONNSTATETIMER
UE Inactive Timer for QCI1 Dynamic DRX
RRCCONNSTATETIMER
MTC UE Inactive Timer
QciPara
UE Inactive Timer for QCI
QciPara
UE Inactivity Timer Dynamic DRX for QCI
QciPara
CIoT UE Inactivity Timer
Definitions
Indicates the length of the UE Inactivity Timer for UEs that do not have QCI-1 services. If the eNodeB detects that such a UE has neither received nor sent data for a period ex parameter, the eNodeB releases the RRC connection for the UE. If this parameter is set to 0, the UE Inactivity Timer is not used. This parameter takes effect only for such UEs t network after the parameter is set. If the QciParaEffectFlag parameter in the GlobalProcSwitch MO is set to ON(On), the UeInactiveTimerForQci parameter in the QciPara M parameter takes effect. This parameter applies only to LTE FDD and LTE TDD.
Indicates the length of the UE Inactivity Timer for UEs that have entered DRX mode and have no QCI-1 services when dynamic DRX is enabled. If the eNodeB detects that such nor sent data for a period exceeding the value of this parameter, the eNodeB releases the RRC connection for the UE. If this parameter is set to a large value, the amount of sig power consumption increases. You are advised to set this parameter to a value greater than that of UlSynTimerDynDrx. In power saving mode, you are advised to set this para different from the value of the UlSynTimerDynDrx parameter, for example a difference of 10 seconds, to avoid power consumption increase due to the increase of signaling. If parameter in the GlobalProcSwitch MO is set to ON(On), the UeInactivityTimerDynDrxQci parameter in the QciPara MO, rather than this parameter takes effect. This param FDD and LTE TDD.
Indicates the length of the UE inactivity timer for NB-IoT UEs. If the eNodeB detects that an NB-IoT UE has neither received nor sent data for a duration exceeding the value of eNodeB releases the RRC connection for the NB-IoT UE. This parameter takes effect only for UEs that will access the network after the parameter is set. This parameter applie
Indicates the length of the UE Inactivity Timer for UEs that have QCI-1 services. If the eNodeB detects that such a UE has neither received nor sent data for a period exceeding parameter, the eNodeB releases the RRC connection for the UE. If this parameter is set to 0, the UE Inactivity Timer is not used. This timer takes effect during the setup of QCI handover or RRC connection reestablishment to a new cell, the eNodeB determines whether the timer takes effect based on whether the UE has QCI-1 bearers. If yes, the tim the timer defined by UeInactiveTimer takes effect. If the QciParaEffectFlag parameter in the GlobalProcSwitch MO is set to ON(ON), this parameter does not take effect. In t CiotUeInactiveTimer parameter in the QciPara MO for QCI 1 takes effect for eMTC UEs, MTC UEs, and UEs with the RRC connection setup cause delayToleran, and the UeInacti in the QciPara MO for QCI 1 takes effect for other types of UEs. This parameter applies only to LTE FDD and LTE TDD.
Indicates the length of the UE Inactivity Timer for UEs that have entered DRX mode and have QCI-1 services when dynamic DRX is enabled. If the eNodeB detects that such a U nor sent data for a period exceeding the value of this parameter, the eNodeB releases the RRC connection for the UE. This parameter takes effect only for such UEs that will ac parameter is set. If the QciParaEffectFlag parameter in the GlobalProcSwitch MO is set to ON(On), the UeInactivityTimerDynDrxQci parameter in the QciPara MO for QCI 1, rat takes effect. This parameter applies only to LTE FDD and LTE TDD.
Indicates the length of the UE Inactivity Timer for category 0 and category M1 UEs and UEs with the RRC connection setup cause value delayToleran when the UEs are not p If the eNodeB detects that such a UE has neither received nor sent data for a period exceeding the value of this parameter, the eNodeB releases the RRC connection for the UE to 0, the UE Inactivity Timer is not used. This parameter takes effect only for such UEs that will access the network after the parameter is set. This parameter applies only to LT
Indicates the length of the UE inactivity timer for UEs that have bearers of a QCI. If the eNodeB detects that a UE has neither received nor sent data for a period exceeding the the eNodeB releases the RRC connection for this UE. If this parameter is set to 0, the UE inactivity timer is not used. This parameter takes effect only for UEs that will access th parameter is set. If a UE has bearers of several QCIs, the eNodeB selects the longest UE Inactivity Timer of bearers with the highest QCI-specific priority specified by the UeIna as the UE inactivity timer for the UE. This parameter applies only to LTE FDD and LTE TDD.
Indicates the length of the UE inactivity timer for UEs that have entered DRX mode and have bearers of the QCI when dynamic DRX is enabled. If the eNodeB detects that a nor sent data for a period exceeding the value of this parameter, the eNodeB releases the RRC connection for this UE. If this parameter is set to a large value, the amount of sig power consumption increases. You are advised to set this parameter to a value greater than that of UlSynTimerDynDrx. In power saving mode, you are advised to set this para different to the value of the UlSynTimerDynDrx parameter, for example a gap of 10 seconds, to avoid power consumption increase due to the increase of signaling. If a UE has the eNodeB selects the longest UE Inactivity Timer of bearers with the highest QCI-specific priority specified by the UeInactiveTimerPri parameter as the UE inactivity timer fo applies only to LTE FDD and LTE TDD.
Indicates the UE inactivity timer for MTC UEs, eMTC UEs, and UEs with the RRC connection setup cause delayToleran. If the eNodeB detects that such a UE has neither recei period exceeding the value of this parameter, the eNodeB releases the RRC connection for the UE. If this parameter is set to 0, the timer length is infinite. This parameter take will access the network after the parameter is set. If a UE has bearers of several QCIs, the eNodeB selects the longest UE inactivity timer of bearers with the highest QCI-specifi UeInactiveTimerPri parameter as the UE inactivity timer for the UE. This parameter applies only to LTE FDD and LTE TDD.
Default Value
Recommended Value
20s
20s
200s
200s
20s
20s
20s
20s
200s
200s
20s
20s
20s
QCI 69: 30 Other QCIs: 20
200s
200s
20s
20s