2-Multi-band Panel Dual Polarization Half-power Beam Width Adjust. Electr. Downtilt Enhanced Sidelobe Suppression 1710
Views 259 Downloads 4 File size 956KB
2-Multi-band Panel Dual Polarization Half-power Beam Width Adjust. Electr. Downtilt Enhanced Sidelobe Suppression
1710 –2200
1710 –2200
X
X
65°
65°
0°– 15°
0°– 15°
18dB
18dB
Downtilt set by hand or by optional RCU (Remote Control Unit) XXPol Panel 1710–2200/1710–2200 65°/65° 18/18dBi 0°–15°/0°–15°T ESLS
800 10510
Type No.
1710–2200 1850 – 1990 MHz 1920 – 2170 MHz
Frequency range 1710 – 1880 MHz Polarization
2000 – 2200 MHz
+45°, –45°; +45°, –45° +45°, –45°; +45°, –45° +45°, –45°; +45°, –45° +45°, –45°; +45°, –45°
Gain at 0° tilt
4 x 17.5 dBi
4 x 17.6 dBi
4 x 17.7 dBi
4 x 17.8 dBi
Horizontal Pattern: Half-power beam width Front-to-back ratio (180° ±30°) Cross polar ratio Sector
0° ±60°
65°
63°
62°
62°
! 30 dB
! 30 dB
! 30 dB
! 28 dB
24 dB ! 9 dB
24 dB ! 9 dB
24 dB ! 10 dB
26 dB ! 10 dB
7.5°
7.2°
6.9°
Vertical Pattern: Half-power beam width
7.9°
Electrical tilt
0°– 15°, continuously adjustable
0° ... 5° ... 10° ... 15° T 0° ... 5° ... 10° ... 15° T 0° ... 5° ... 10° ... 15° T 0° ... 5° ... 10° ... 15° T Sidelobe suppression – for first sidelobe above main beam ! 17 ... 20 ... 18 ... 17 dB ! 16 ... 20 ... 18 ... 18 dB ! 15 ... 19 ... 18 ... 17 dB ! 14 ... 18 ... 18 ... 16 dB – within 0°–20° sector above horizon ! 17 ... 18 ... 18 ... 16 dB ! 16 ... 17 ... 17 ... 16 dB ! 15 ... 17 ... 17 ... 16 dB ! 14 ... 16 ... 16 ... 15 dB Null-fill at 0° tilt
23 dB
22 dB
21 dB
Impedance
50 "
VSWR
< 1.5
Isolation, between ports
20 dB
> 30 dB
Intermodulation IM3
< –153 dBc (2 x 43 dBm carrier)
Max. power per input
300 W (at 50 °C ambient temperature)
1710 – 1880 MHz: +45°/ –45° Polarization 125°
66° 7.9°
dB
3
3
dB
10
10
0
1710– 2200 +45°
1710– 2200 –45°
1710– 2200 +45°
1710– 2200 –45°
7-16
7-16
7-16
7-16
0
Horizontal Pattern
Vertical Pattern 0°– 15° electrical downtilt
1850 – 1990 MHz: +45°/ –45° Polarization 120°
65°
Mechanical specifications
3
Adjustment mechanism
dB
dB
3
0
0
Horizontal Pattern
Vertical Pattern 0°– 15° electrical downtilt
1920 – 2200 MHz: +45°/ –45° Polarization 115°
63°
0
Horizontal Pattern Internet: http://www.kathrein.de
Wind load
Bottom 2 x, Position bottom continuously adjustable 17 kg Frontal: Lateral: Rearside:
600 N (at 150 km/h) 120 N (at 150 km/h) 650 N (at 150 km/h) 200 km/h
1686 x 337 x 112 mm 1389 / 323 / 71 mm
dB
3
Packing size Height/width/depth
10
dB
3
4 x 7-16 female
Weight
Max. wind velocity 7.1°
10
Input Connector position
10
10
936.3161/c
Subject to alteration.
7.5°
0
Vertical Pattern 0°– 15° electrical downtilt
800 10510
Page 1 of 4
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494
Accessories General Information
Type No.
Description
Remarks
Weight approx.
72 64 9
20
Accessories (order separately) Units per antenna
738 546
1 clamp
Mast: 50 – 115 mm diameter
1.0 kg
2
850 10002
1 clamp
Mast: 110 – 220 mm diameter
2.7 kg
2
850 10003
1 clamp
Mast: 210 – 380 mm diameter
4.8 kg
2
737 974
1 downtilt kit
Downtilt angle: 0° – 15°
2.8 kg
1
Material:
Reflector screen: Tin-plated copper. Radiator: Tin-plated zinc. Flat fiberglass radome: The max. radome depth is only 71 mm. Fiberglass material guarantees optimum performance with regards to stability, stiffness, UV resistance and painting. The colour of the radome is grey. All screws and nuts: Stainless steel.
Grounding:
The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded.
1389 1436 1494 1636
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed.
Environmental conditions: Kathrein cellular antennas are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E. The antennas exceed this standard with regard to the following items: – Low temperature: –55 °C – High temperature (dry): +60 °C
Kathrein antennas have passed environmental tests as recommended in ETS 300 019-2-4. The homogenous design of Kathrein’s antenna families use identical modules and materials. Extensive tests have been performed on typical samples and modules.
254 48 41 71 98
Environmental tests:
Adjustment mechanism with integrated scale 30
Ice protection: Due to the very sturdy antenna construction and the protection of the radiating system by the radome, the antenna remains operational even under icy conditions.
323 Bottom view –45° –45° RCU +45° +45° 1710–2200 Left Right 1710–2200 RCU
Layout of interface
The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4, which includes the static mechanical load imposed on an antenna by wind at maximum velocity. Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or even cause it to fall to the ground. These facts must be considered during the site planning process. The installation team must be properly qualified and also be familiar with the relevant national safety regulations. The details given in our data sheets have to be followed carefully when installing the antennas and accessories. The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must be obeyed. Any previous datasheet issues are invalid.
Page 2 of 4
800 10510
Internet: http://www.kathrein.de
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494
Subject to alteration.
As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions.
936.3161/c
Please note:
General Instructions for Adjustment Mechanism
Description of the adjustment mechanism (protective cap removed):
1
1
2 2
➀ Adjustment wheel with twist-lock function. ➁ Downtilt spindle with integrated scale.
➀ Thread for fixing the protective cap or the RCU (Remote Control Unit). ➁ Gearwheel for RCU power drive.
To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment.
Manual adjustment procedure:
0° – max.°
max.° – 0°
Remove the protective cap.
Set downtilt angle by rotating the adjustment wheel.
Screw on the protective cap again.
936.3161/c
Subject to alteration.
Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment:
For a description of RCU installation please refer to the respective data sheet. Internet: http://www.kathrein.de
800 10510
Page 3 of 4
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494
General Instructions for Feederline Installation on Panels with four Connectors arranged on two Levels Please note: In order not to damage the interfaces, please make sure that only the right tools are used. Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench width.
Description of connector arrangement:
4
3
2
1
There are four interfaces for feeding the antenna located at the bottom.
The connectors are mounted at two levels in order to facilitate feederline installation.
Attachment of the feederline connector and RCU (optional): In order to protect the adjustment mechanism the protective caps have to be attached during feederline installation!
Place the connector carefully and fix the nut using a torque-wrench (according to the manufacturers guidelines).
After feederline installation the optional remote control units (RCU) can be mounted if required.
For a full description of RCU installation please refer to the respective data sheet.
Subject to alteration.
Start with the rearside located interface no. 1.
936.3161/c
The further sequence for the installation is: feederlines no. 2, 3, 4.
Please note: Additional weather sealing of correctly installed feederline connector interfaces is not required, nor is it recommended by the connector manufacturers. Page 4 of 4
800 10510
Internet: http://www.kathrein.de
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494