ARISTONCAVI Cables for Liquids

Electric cables. SUBMERSIBLE El ec tri c cables f o r l iqui d res is ta n ce. Aristoncavi spa reserve the right to

Views 206 Downloads 37 File size 2MB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

Citation preview

Electric cables.

SUBMERSIBLE

El ec tri c cables f o r l iqui d res is ta n ce.

Aristoncavi spa reserve the right to modify the data in this catalogue without notice. © 03/2012 Copyright Drawings and technical descriptions in this catalogue may not, under penalty of law, be copied, reprinted, duplicated or otherwise wrongfully reproduced or utilized without our written consent, in either their original state or after alteration. The names, trademarks and designs of our products are all protected by law. It does not constitute a warrantee of any kind, expressed or implied, of our products or their suitability for any particular use.

I ndex .

H 07R N 8- F - S1R N 8- F

SU B M E R SI B L E

10

S1R C 4N 8- F

SU B M E R SI B L E S

12

S1BNH2-F

SU B F L AT

14

NSSHOU 0/J

SN A K E F L E X

16

NAUTILUS 500 0,6/1 kV

N AU T I LU S 500

20

NAUTILUS 500 S 0,6/1 kV

N AU T I LU S 500 S

24

RG7OEFE 0,6/1 kV

MA R I N E

26

DRINCABLE® 450/750 V - 0,6/1kV

DRINCABLE®

30

DRINCABLE® PLUS 450/750 V - 0,6/1 kV

D R I N C A B L E ® PLU S

34

H07RN-F OR

OERRE

38

07BN2-F

T E R MA L E

42

URSUS® MT SUB PLUS

U R SU S® MT SUB PLUS

46

URSUS® MT SUB-E

U R SU S® MT SU B - E

50

DRINCABLE® MT PLUS

D R I N C A B L E ® MT PLUS

54

Technical data

57

Submersible pumps

Submersed pumps

Sea bed laying

meters

S UB M ER SI B L E

100

S UB M ER SI B L E S

100

S UB F L AT

100

S N AK EF L EX

100

O E R RE

100

T ER MAL E

100

MA R INE

200

U R S U S® MT SU B P LUS

300

U R S U S® MT SU B -E

300

DR I NC ABL E® MT P LUS

300

N AUT I LU S 5 0 0

500

N AUT I LU S 5 0 0 S

500

DR I NC ABL E®

600

DR I NC ABL E® PLUS

600

Drinking water

Oil lubrication

Hot and aggressive water Trailing operation in water, for mining and tunnelling Trailing operation of dredgers and floating docks Main use

(*)

See chemical resistance table p. 62

D R I N C A B L E ® M T P LU S

URSUS® MT SUB-E

U R S U S ® M T S U B P LU S

TERMALE

OERRE

D R I N C A B L E ® P LU s

DRINCABLE®

MARINE

N AU T I LU S 5 0 0 S

N AU T I LU S 5 0 0

SNAKEFLEX

S U B F L AT

SUBMERSIBLE S

SUBMERSIBLE

Ma x cab le s i m m e r s ion d e p t h.

H07RN8-F / S1RN8-F

ARISTONCAVI

8

9

ARISTONCAVI

SUB M E R SI BL E

Electrical working data

HD 22.16 or VDE 0282 Par t 16 (H07RN8-F) / based on HD 22.16 or on VDE 0282 Par t 16 (S1RN8-F)

Nominal rated voltage U 0 / U

IEMMEQU HAR (only H07RN8-F)

Test voltage Max AC voltage Max DC voltage Current rating

V - kV 450/750 - 0,6/1 kV 2,5/4 V - kV 520/900 - 0,7/1,2 kV 1,35 - 1,8 A

See table p. 59

Thermal working data

3

2 1

Maximum short circuit temperature

°C 200 (250°C for S1RN8-F)

Maximum working temp. on the conductor

°C 80 (90°C for S1RN8-F)

Ambient temperature

°C - 20 to + 50

Mechanical working data Bending radius* Maximum tensile load

mm Static condition: 4 x D, Mobile condition: 6 x D N/mm 2

15

* (D = outer diameter)

Chemical working data

Cable construction 1

Phase Conductors

Conductor material Conductor construction

2

Insulation

Insulation material

Cores identification 3

Outer Sheath

bare copper class 5 IEC 60228 EPR compound: EI4 quality (450/750V ) acc.to EN 50363-1, 3GI3 quality (0,6/1kV ) acc.to VDE 0207 par t 20 According to HD 308

Material Rubber compound, EM2 quality Colour Black

Applications Tough rubber unscreened cable for installation inside or outside in dr y, damp or wet environments and in hazardous environments (subjec t to local regulations). I t can be immersed in fresh and salt water to a depth of 100 meters: for flexible power supplies, suitable for submersible motors and pumps. The synthetic rubber compound is ozone, UV, sunlight and weather resistant.

Resistance to oil

According to IEC 60811-2-1

Ozone resistance

According to IEC 60811-2-1

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

ARISTONCAVI

SUB M E R SI BL E Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5 17,0 19,5 22,2

5,9 6,6 7,4 8,2 9,9 11,1 13,0 14,5 17,0 19,1 21,8 23,8 26,4 29,0 32,0 35,0

6,5 7,1 7,9 8,8 10,4 11,7 13,6 15,0 17,5 19,7 22,9 25,0 27,6 30,2 33,2 36,1

50 65 90 115 180 250 360 480 660 885 1140 1450 1740 2170 2650 3410

23 38 60 90 150 240 375 525 750 1050 1425 1800 2250 2775 3600 4500

2x1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1

7,7 8,6 10,2 11,6 13,2 17,8 20,2 24,0

8,2 9,2 10,8 12,1 13,8 18,4 21,3 25,2

90 110 165 220 295 525 715 1040

30 45 75 120 180 300 480 750

3G1 3G1,5 3G2,5 3G4 3G6 3G10 3G16 3G25 3G35 3G50 3G70 3G95 3G120 3G150

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5

8,6 9,6 11,4 13,0 14,6 19,7 22,5 26,5 29,6 33,2 39,7 45,0 49,0 53,9

9,2 10,1 12,0 13,6 15,1 20,3 23,6 27,7 30,7 34,4 40,9 46,7 50,8 55,7

110 145 210 290 380 680 940 1350 1790 2340 3300 4260 5320 6410

45 68 113 180 270 450 720 1125 1575 2250 3150 4275 5400 6750

10

11

ARISTONCAVI

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

3G185 3G240

17,0 19,5

58,0 66,9

59,7 69,2

7730 9910

8325 10800

4G1 4G1,5 4G2,5 4G4 4G6 4G10 4G16 4G25 4G35 4G50 4G70 4G95 4G120 4G150 4G185 4G240

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5 17,0 19,5

9,6 10,7 12,7 14,4 16,4 21,5 24,7 29,6 32,7 38,8 43,7 49,8 54,0 59,5 63,3 71,6

10,1 11,3 13,3 14,9 17,0 22,7 25,8 30,7 33,8 40,0 45,4 51,6 55,8 61,3 65,6 74,0

140 175 260 355 485 845 1170 1720 2260 3140 4190 5420 6730 8160 9760 12190

60 90 150 240 360 600 960 1500 2100 3000 4200 5700 7200 9000 11100 14400

5G1,5 5G2,5 5G4 5G6 5G10 5G16 5G25

1,5 1,9 2,4 2,9 3,8 4,8 6,1

11,8 13,9 15,8 18,2 23,7 27,5 32,7

12,3 14,5 16,4 18,8 24,9 28,6 33,8

220 320 440 310 1040 1460 2130

113 188 300 450 750 1200 1875

7G1,5

1,5 1,5 1,5 1,9 1,9 1,9

15,8 18,3 21,5 18,5 21,4 25,4

16,4 18,9 22,7 19,2 22,6 26,5

360 515 745 525 755 1080

158 270 405 263 450 675

1,5/1 1,9/1 1,5/0,8 1,5/1 1,9/0,8 1,9/1

13,7

15,8

290

15,9

18,2

400

15,1

17,3

375

15,1

17,3

365

17,7

20,1

515

17,7

20,1

520

90 150 158 158 263 263

12G1,5 18G1,5 7G2,5 12G2,5 18G2,5 4G1,5 + 2x0,75 4G2,5 + 2x0,75 7G1,5 + 3x0,50 7G1,5 + 3x0,75 7G2,5 + 3x0,50 7G2,5 + 3x0,75

S07RC4N8-F / S1RC4N8-F

ARISTONCAVI

12

13

ARISTONCAVI

SUBMERSIBLE S

Electrical working data

Based on HD 22.16

Nominal rated voltage U 0 / U

V - kV 450/750 - 0,6/1

Test voltage

kV 2,5 - 4

Max AC voltage

V - kV 520/900 - 0,7/1,2

Max DC voltage

kV 1,35 - 1,8

Current rating

A

See table p. 59

Thermal working data 5

4

2

Maximum short circuit temperature

°C 250°C

Maximum working temp. on the conductor

°C 90°C

Ambient temperature

°C - 25 to + 50

3

1

Mechanical working data Bending radius*

mm 14 x D

Maximum tensile load

N/mm 2

15

* (D = outer diameter)

Chemical working data

Cable construction 1

Phase Conductors

Conductor material Conductor construction

2

Insulation

bare copper class 5 IEC 60228

Insulation material EPR compound: EI4 quality (450/750V ) acc.to EN 50363-1,

3GI3 quality (0,6/1kV ) acc.to VDE 0207 par t 20

Cores identification

According to HD 308

3

Inner sheath

Material Rubber compound

4

Screen

Material Bare copper braid

5

Outer Sheath

Material Rubber compound, EM2 quality according to EN 50363-2-1 Colour Black

Applications Tough rubber screened cable for installation inside or outside in dr y, damp or wet environments and in hazardous environments (subjec t to local regulations). I t can be immersed in fresh and salt water to a depth of 100 meters: for flexible power supplies, suitable for submersible motors and pumps. The synthetic rubber compound is ozone, UV, sunlight and weather resistant.

Resistance to oil

According to IEC 60811-2-1

Ozone resistance

According to IEC 60811-2-1

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

3G1,5/1,5KON 3G2,5/2,5KON 3G4/4KON 3G6/6KON 3G10/10KON 3G16/16KON

1,5 1,9 2,4 2,9 3,8 4,8

12,5 14,3 15,8 17,8 20,8 23,7

13,1 14,9 16,4 18,4 21,9 24,8

250 330 420 570 830 1140

68 113 180 270 450 720

6,1 7,2 8,9 10,6 12,3 13,8

29,6 31,5 37,6 42,3 45,6 51,6

30,8 32,7 38,8 44,0 47,3 53,4

1790 2150 3070 4100 4910 6350

1125 1575 2250 3150 4275 5400

3x25 + 3x16/3 + 3x35 + 3x16/3 + 3x50 + 3x25/3 + 3x70 + 3x35/3 + 3x95 + 3x50/3 + 3x120 + 3x70/3 +

KON KON KON KON KON KON

S1BNH2-F

ARISTONCAVI

14

S U B F L AT

15

ARISTONCAVI

Electrical working data

Based on HD 22.16

Nominal rated voltage U 0 / U

kV 0,6/1

Test voltage

kV 4

Max AC voltage

kV 0,7/1,2

Max DC voltage

kV 1,8

Current rating

A

See table p. 59

Thermal working data Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Ambient temperature

°C - 25 to + 50

Mechanical working data

3

Bending radius*

mm 3 x H ( for H ≤ 12 mm ) 4 x H ( for H > 12 mm )

Maximum tensile load

2 1

N/mm 2

15

* (H = height)

Chemical working data

Cable construction 1

Phase Conductors

Conductor material Conductor construction

2

Insulation

class 5 IEC 60228

Insulation material EPR compound, EI7 quality according to EN 50363-1

Cores identification 3

tinned copper

Outer Sheath

According to HD 308 Material Special rubber compound, EM2 quality according to EN 50363-2-1 Colour Black

Applications Tough rubber unscreened 0.6/1kV flat cable for installation inside or outside in dr y, damp or wet environments and in hazardous environments (subjec t to local regulations). I t can be immersed in fresh and salt water to a depth of 100 meters: for flexible power supplies, suitable for submersible motors and pumps. The synthetic rubber compound is ozone, UV, sunlight and weather resistant.

Resistance to oil

According to IEC 60811-2-1

Ozone resistance

According to IEC 60811-2-1

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

Cores x cross section

Conductor Ø

Min height

Max height

Min width

Max width

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

mm

mm

kg/km

N

3G4 3G6 3G10 3G16 3G25 3G35 3G50 3G70 3G95

2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,5

7,3 7,7 10,1 12,1 14,2 16,0 18,5 20,5 23,0

8,3 8,7 11,1 13,6 15,7 17,5 20,0 23,0 25,5

15,7 17,8 22,8 27,7 32,6 37,0 44,1 50,5 57,0

16,7 18,8 23,8 28,7 33,6 38,0 45,1 52,0 58,5

260 330 560 840 1220 1630 2250 2990 3760

180 270 450 720 1125 1575 2250 3150 4275

4G4 4G6 4G10 4G16 4G25 4G35 4G50

2,4 2,9 3,8 4,8 6,1 7,2 8,9

8,0 8,5 10,0 12,0 16,0 18,5 19,3

9,0 9,5 11,0 13,5 17,5 20,0 20,8

23,0 24,5 29,5 34,5 42,3 48,5 56,7

24,0 25,5 30,5 36,0 43,8 50,0 58,2

410 500 740 1070 1720 2300 2970

240 360 600 960 1500 2100 3000

NSSHÖU O/J

ARISTONCAVI

16

17

ARISTONCAVI

SNAKEFLEX

Electrical working data

DIN VDE 0250 Par t 812 approved

Nominal rated voltage U 0 / U

kV 0,6/1

Test voltage

kV 4

Max AC voltage

kV 0,7/1,2

Max DC voltage

kV 1,8

Current rating

A

See table p. 59

Thermal working data

4

3

1 2

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Ambient temperature

°C - 25 to + 80

Mechanical working data Bending radius* Maximum tensile load

mm Static condition: 4 x D, Mobile condition: 5 x D N/mm 2

15

* (D = outer diameter)

Chemical working data

Cable construction 1

Phase Conductors

Conductor material Conductor construction

2

Insulation

tinned copper class 5 VDE 0295 (IEC 60228)

Insulation material 3GI3 quality rubber compound, according to VDE 0207 Par t 20 Nominal thickness According to VDE 0250 Par t 812

Cores identification

According to VDE 0293 Par t 308 (HD 308)

3

Inner sheath

Material Rubber compound GM1b quality, according to VDE 0207 Par t 21

4

Outer Sheath

Material Rubber compound 5GM5 quality, according to VDE 0207 Par t 21 Colour Yellow

Applications Heav y dut y, flame retardant, abrasion, notch, tear, oils and fats resistant flexible cable for aggressive environments. Snak eflex is suitable for installation inside or outside in dr y, damp or wet environments and in hazardous environments (subjec t to local regulations). I t can be immersed in fresh water, salt water, waste water, stor m water, oily water and se wage contaminated water to a depth of 100 meters. For power supplies and controlling in mines, quar r ies, industr ial plants, agr icultural applications and in general where mechanical stress and abrasion is lik ely.

Resistance to oil

According to IEC 60811-2-1

Ozone resistance

According to IEC 60811-2-1

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

ARISTONCAVI

18

19

ARISTONCAVI

SNAKEFLEX Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,5 14,2 15,9 17,7 20,1 22,5

6,3 7,0 7,6 8,2 9,5 10,5 13,0 14,1 16,2 18,3 20,5 22,8 25,0 28,2 31,1 34,9

7,0 7,7 8,3 8,9 10,2 11,2 13,7 14,8 16,9 19,0 21,7 24,0 26,2 29,4 32,3 36,1

60 75 95 120 180 245 375 480 660 875 1150 1430 1750 2180 2770 3510

23 38 60 90 150 240 375 525 750 1050 1425 1800 2250 2775 3600 4500

2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25

1,5 1,9 2,4 2,9 3,8 4,8 6,1

11,2 12,5 14,9 16,0 19,3 21,1 25,4

11,8 13,1 15,5 16,6 19,9 22,2 26,5

170 220 320 385 580 765 1150

45 75 120 180 300 480 750

3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,5 14,2 15,9 17,7

11,7 13,1 15,6 16,8 20,2 22,3 26,9 30,2 35,8 39,3 45,7 48,2 52,6 58,7

12,3 13,7 16,2 17,4 21,3 23,4 28,0 31,4 37,0 40,5 47,4 49,9 54,4 61,0

190 255 375 465 710 930 1390 1880 2500 3460 4570 5220 6460 7980

68 113 180 270 450 720 1125 1575 2250 3150 4275 5400 6750 8325

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

4x1,5 4x2,5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 4x185

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,5 14,2 15,9 17,7

12,5 15,3 16,7 18,1 21,9 25,2 30,6 32,8 39,0 42,8 49,9 55,6 60,6 67,4

13,1 15,9 17,3 18,7 23,0 26,3 31,8 34,0 40,2 44,5 51,7 57,4 62,9 69,7

225 350 440 550 860 1210 1810 2330 3300 4300 5680 6820 8270 10350

90 150 240 360 600 960 1500 2100 3000 4200 5700 7200 9000 11100

5x1,5 5x2,5 5x4 5x6 5x10 5x16 5x25

1,5 1,9 2,4 2,9 3,8 4,8 6,1

13,4 16,4 18,0 20,3 23,7 27,3 33,2

14,0 17,0 18,6 21,4 24,8 28,4 34,4

270 410 525 715 1040 1470 2220

113 188 300 450 750 1200 1875

7x1,5 12x1,5 18x1,5 7x2,5 12x2,5 18x2,5

1,5 1,5 1,5 1,9 1,9 1,9

16,9 19,6 22,2 19,2 22,3 26,5

17,5 20,2 23,3 19,8 23,4 27,6

400 540 750 560 790 1110

158 270 405 263 450 675

4x1,5 + 2x0,75

1,5 / 1 1,9 / 1 1,5 / 0,8 1,5 / 1 1,9 / 0,8 1,9 / 1

13,8

16,0

295

16,8

19,2

440

16,3

18,6

410

16,3

18,6

400

18,5

21,0

540

18,5

21,0

545

90 150 158 158 263 263

4x2,5 + 2x0,75 7x1,5 + 3x0,50 7x1,5 + 3x0,75 7x2,5 + 3x0,50 7x2,5 + 3x0,75

NAUTILUS 500 0,6/1kV

ARISTONCAVI

20

21

ARISTONCAVI

N AU T I LU S 5 0 0

Electrical working data

Based on HD 22.16, HD 22.12

Nominal rated voltage U 0 / U

kV 0,6/1

Test voltage

kV 4

Max AC voltage

kV 0,7/1,2

Max DC voltage

kV 1,8

Current rating

A

See table p. 59

Thermal working data

4

3

2

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Ambient temperature

°C - 25 to + 80

1

Mechanical working data Bending radius* Maximum tensile load

mm Static condition: 4 x D, Mobile condition: 6 x D N/mm 2

15

* (D = outer diameter)

Chemical working data

Cable construction 1

Phase Conductors

Conductor material Conductor construction

2

Insulation

Tinned copper class 5 IEC 60228

Insulation material EPR compound, EI7 quality according to EN 50363-1

Cores identification

According to HD 308

3

Inner sheath

Material EPDM rubber compound

4

Outer Sheath

Material CPE based rubber compound Colour Black

Applications NAUTILUS 500 is a 0.6/1kV flexible cable suitable for per manent immersion to a depth of 500 meters in fresh, salt and polluted water where mobile laying is needed lik e power tools, submersible pumps etc. Available with steel ar mour for under-water power transmission in a fixed installation. The synthetic rubber compound is ozone, UV, sunlight and weather resistant.

Resistance to oil

According to IEC 60811-2-1

Ozone resistance

According to IEC 60811-2-1

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

ARISTONCAVI

22

23

ARISTONCAVI

N AU T I LU S 5 0 0 Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5 17,0 19,5 22,2

5,7 6,4 7,2 8,0 9,7 10,9 12,8 14,3 16,8 18,9 21,6 23,7 26,2 28,7 31,7 34,8

6,3 7,0 7,8 8,6 10,4 11,6 13,5 15,0 17,5 19,6 22,6 24,7 27,2 29,7 32,8 35,9

52 69 92 120 184 249 359 473 670 897 1183 1469 1807 2202 2828 3471

23 38 60 90 150 240 375 525 750 1050 1425 1800 2250 2775 3600 4500

2x1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1

7,6 8,5 10,2 11,5 13,0 17,6 20,0 24,5

8,2 9,1 10,9 12,2 13,7 18,3 20,7 25,1

88 112 164 219 291 513 691 1032

30 45 75 120 180 300 480 750

3G1 3G1,5 3G2,5 3G4 3G6 3G10 3G16 3G25 3G35 3G50 3G70 3G95 3G120 3G150

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5

8,3 9,7 11,1 12,5 14,2 19,7 21,9 25,9 28,9 34,0 38,5 44,3 47,8 53,1

8,9 10,3 11,8 13,2 14,9 20,3 22,6 26,9 29,9 35,1 39,6 45,4 49,5 54,9

110 143 204 276 370 665 891 1302 1696 2395 3208 4226 5178 6386

45 68 113 180 270 450 720 1125 1575 2250 3150 4275 5400 6750

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

3G185 3G240

17,0 19,5

58,3 65,7

60,4 67,8

7805 10129

8325 10800

4G1 4G1,5 4G2,5 4G4 4G6 4G10 4G16 4G25 4G35 4G50 4G70 4G95 4G120 4G150 4G185 4G240

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5 17,0 19,5

9,2 10,5 12,5 14,1 16,1 21,3 24,1 28,9 32,2 38,5 43,3 49,9 54,2 59,3 65,4 73,4

9,8 11,2 13,2 14,8 16,8 22,0 24,8 29,9 33,3 39,6 44,4 51,7 56,0 61,4 67,5 75,9

134 176 258 351 480 823 1119 1666 2173 3127 4156 5529 6765 8247 10088 13092

60 90 150 240 360 600 960 1500 2100 3000 4200 5700 7200 9000 11100 14400

5G1,5 5G2,5 5G4 5G6 5G10 5G16 5G25

1,5 1,9 2,4 2,9 3,8 4,8 6,1

11,6 13,8 15,8 17,9 23,5 26,6 32,0

12,3 14,5 16,5 18,6 24,2 27,6 33,1

218 320 445 600 1018 1399 2065

113 188 300 450 750 1200 1875

7G1,5 8G1,5 10G1,5 12G1,5 7G2,5 8G2,5 10G2,5 12G2,5

1,5 1,5 1,5 1,5 1,9 1,9 1,9 1,9

15,4 16,6 17,9 18,6 18,3 19,7 21,1 21,7

16,0 17,2 18,5 19,2 18,9 20,3 22,2 22,8

330 390 430 480 490 560 630 710

158 180 225 270 263 300 375 450

NAUTILUS 500 S 0,6/1kV

ARISTONCAVI

24

25

ARISTONCAVI

N AU T I LU S 5 0 0 S

Electrical working data

Based on HD 22.16, HD 22.12

Nominal rated voltage U 0 / U

kV 0,6/1

Test voltage

kV 4

Max AC voltage

kV 0,7/1,2

Max DC voltage

kV 1,8

Current rating

A

See table p. 59

Thermal working data 5

4

2 3

1

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Ambient temperature

°C - 25 to + 80

Mechanical working data Bending radius*

mm 14 x D

Maximum tensile load

N/mm 2

15

* (D = outer diameter)

Chemical working data Resistance to oil

According to IEC 60811-2-1

Ozone resistance

According to IEC 60811-2-1

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

Cable construction 1

Phase Conductors

Conductor material Conductor construction

2

Insulation

Tinned copper class 5 IEC 60228

Insulation material EPR compound, EI7 quality according to EN 50363-1

Cores identification

According to HD 308

3

Inner sheath

Material EPDM based rubber compound

4

Screen

Material Tinned copper braid

5

Outer Sheath

Material CPE based rubber compound Colour Black

Applications NAUTILUS 500S is a 0.6/1kV overall screened cable suitable for per manent immersion to a depth of 500 meters in fresh, salt and polluted water where mobile laying is needed., lik e power tools, submersible pumps etc. Available with steel ar mour for under-water power transmission in a fixed installation. The synthetic rubber compound is ozone, UV, sunlight and weather resistant.

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

3G1,5/1,5KON 3G2,5/2,5KON 3G4/4KON 3G6/6KON 3G10/10KON 3G16/16KON

1,5 1,9 2,4 2,9 3,8 4,8

12,5 14,3 15,8 17,8 20,8 23,7

13,1 14,9 16,4 18,4 21,9 24,8

240 320 410 550 810 1080

68 113 180 270 450 720

6,1 7,2 8,9 10,6 12,3 13,8

28,3 30,1 36,2 41,2 44,2 50,7

29,4 31,3 37,4 42,9 45,9 52,5

1640 1980 2860 3880 4660 6070

1125 1575 2250 3150 4275 5400

3x25 + 3x16/3 + 3x35 + 3x16/3 + 3x50 + 3x25/3 + 3x70 + 3x35/3 + 3x95 + 3x50/3 + 3x120 + 3x70/3 +

KON KON KON KON KON KON

RG7OEFE-0,6/1kV

ARISTONCAVI

26

27

ARISTONCAVI

MARINE Based on CEI 20-13, IEC 60502-1 Electrical working data Nominal rated voltage U 0 / U

kV 0,6/1

Test voltage

kV 4

Max AC voltage

kV 0,7/1,2

Max DC voltage

kV 1,8

Current rating

5

A

according to CEI 20-21, IEC 60287

4 2

Thermal working data

3

1

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Ambient temperature

°C - 25 to + 50

Mechanical working data Bending radius* Maximum tensile load

mm Static condition: 14 x D N/mm 2

75 (acc.to CEI 11-17)

* (D = outer diameter)

Chemical working data Cable construction 1

Phase Conductors

Conductor material Conductor construction

2

Insulation

tinned copper class 2 IEC 60228

Insulation material Cross-linked HEPR compound, G7 quality

Cores identification

According to HD 308

3

Inner sheath

Material Polyethylene

4

Armouring

Material 1° galvanized steel wires, 2° spiral galvanized steel tape

5

Outer Sheath

Material Polyethylene Colour Black

Applications M ar ine cable is a 0.6/1kV under water cable designed to be laid on the sea bed in fixed installation. M ar ine cables require special designs that are able to withstand specific environmental conditions: ex ter nal pressure and mechanical stress dur ing laying operations or dur ing ser vice life. The specific t ype of ar mour ing of this cable guarantees operations for deep -laying with an ex ter nal pressure measur ing up to 20 bar (approx 200 meters). The t ypical use is under water power transmission in fresh or salt water. The t ype and qualit y of the mater ial used for the outer sheath provide excellent ultraviolet resistance.

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

ARISTONCAVI

28

29

ARISTONCAVI

MARINE

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

3G25 3G35 3G50 3G70 3G95 3G120 3G150 3G185 3G240

5,9 6,9 8,0 9,6 11,4 13,0 14,3 16,1 18,4

33,5 36,0 39,3 46,4 50,7 56,0 61,4 67,2 74,6

34,7 37,2 40,5 48,1 52,5 57,8 63,7 69,5 77,0

2450 2760 3340 4790 5940 7400 8930 10620 13160

5625 7875 11250 15750 21375 27000 33750 41625 54000

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

4G25 4G35 4G50 4G70 4G95 4G120 4G150 4G185 4G240

5,9 6,9 8,0 9,6 11,4 13,0 14,3 16,1 18,4

36,1 38,7 44,8 50,2 55,0 61,7 66,9 74,1 81,3

37,3 39,9 46,5 52,0 56,8 64,0 69,2 76,5 84,2

2900 3320 4490 5810 7250 9280 10930 13260 16360

7500 10500 15000 21000 28500 36000 45000 55500 72000

3x35 + 25N 3x50 + 25N 3x70 + 35N 3x95 + 50N 3x120 + 70N 3x150 + 95N

6,9 8,0 9,6 11,4 13,0 14,3

38,1 43,2 47,8 52,5 59,2 64,2

39,3 44,9 49,5 54,3 61,0 66,5

3190 4150 5280 6560 8490 10110

7875 11250 15750 21375 27000 33750

DRINCABLE® 450/750 V - DRINCABLE® 0,6/1 kV

ARISTONCAVI

30

31

ARISTONCAVI

DRINCABLE® 07 / DRINCABLE® 1 Based on HD 22.16, HD 22.12 Electrical working data

ACS / WRAS / D.M. 174/04

Nominal rated voltage U 0 / U Test voltage Max AC voltage Max DC voltage Current rating

V - kV 450/750 - 0,6/1 kV 2,5 - 4 V - kV 520/900 - 0,7/1,2 kV 1,35 - 1,8 A

See table p. 59

3

2

Thermal working data 1

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Min ambient temperature

°C - 25

Max water temperature

°C 40

Mechanical working data Bending radius* Maximum tensile load

Cable construction

mm ROUND: Static condition: 3 x D Mobile condition: 5 x D

FLAT: 3 x H ( for H ≤ 12 mm ) 4 x H ( for H > 12 mm ) N/mm

2

15

* (D = outer diameter) (H = height) 1

Phase Conductors

Conductor material Conductor construction

2

Insulation

Outer Sheath

class 5 IEC 60228

Insulation material EPR compound: EI6 quality (450/750V ) acc.to EN 50363-1,

Chemical working data

3GI3 quality (0,6/1kV ) acc.to VDE 0207 par t 20

Cores identification 3

Tinned copper

According to HD 308 Material Special cross-linked compound, EM6 quality (related to mechanical

and thermal proper ty) according to EN 50363-2-1 Colour Blue

Applications Flexible NON TOXIC, WATERPR OOF and SUBMERSIBLE (up to 600 meters depth) elec tr ic cable, with special rubber insulation and outer sheath, suitable for per manent immersion in dr ink ing water. The exceptional per for mance of Ar istoncavi DRINCABLE® is provided by the unique and propr ietar y compound used for the outer sheath. The cables have successfully passed r igorous testing and are fully qualified to the Br itish WRAS cer tification (according to BS 6920), the French ACS cer tification for direc t and per manent immersion in potable water and are respec ting the I talian DM 174/04. The approval protocols have ver ified the absence of microbial growth, the water taste, appearance, transparenc y and colour and the absence of any metals or toxic substances. Elec tr ical parameters: according to HD 22.12 and BS 7919. On request DRINCABLE® is also available with a rated voltage of 0,6/1kV and in flat version (FL family). For submersible pumps for dr ink ing water, operation and control equipment in aquar iums, fish-ponds, operation of control, depuration/chlor ination systems installed in water main and dr ink ing water fountains, elec tr ical installations in manufac tur ing, processing and preser ving systems of dr inks and foodstuff, swimming pool lightings, depuration and cleaning system.

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

ARISTONCAVI

32

33

ARISTONCAVI

DRINCABLE® 07 / DRINCABLE® 1 ROUND CABLES Min overall Max overall Ø Ø

Cores x cross section

Conductor Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5 17,0 19,5 22,2

5,9 6,6 7,4 8,2 9,9 11,1 13,0 14,5 17,0 19,1 21,7 23,8 26,4 29,0 32,0 35,0

6,4 7,1 7,9 8,7 10,5 11,7 13,6 15,1 17,6 19,7 22,8 24,9 27,5 30,2 33,2 36,2

46 62 84 111 171 234 340 449 640 861 1133 1411 1745 2133 2747 3375

23 38 60 90 150 240 375 525 750 1050 1425 1800 2250 2775 3600 4500

2x1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1

8,0 9,0 10,7 12,1 13,6 18,3 20,5 24,4

8,5 9,5 11,3 12,7 14,2 18,9 21,6 25,5

87 111 161 218 287 507 684 995

30 45 75 120 180 300 480 750

3G1,5 3G2,5 3G4 3G6 3G10 3G16 3G25 3G35 3G50 3G70 3G95 3G120 3G150 3G185

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5 17,0

9,7 11,5 13,0 14,6 19,7 22,1 26,3 28,8 33,8 37,9 43,5 47,5 52,8 58,1

10,3 12,1 13,6 15,2 20,3 23,2 27,4 29,9 35,0 39,1 45,2 49,2 54,6 59,9

135 198 271 358 635 864 1263 1618 2288 3050 4032 4970 6147 7514

68 113 180 270 450 720 1125 1575 2250 3150 4275 5400 6750 8325

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

4G1,5 4G2,5 4G4 4G6 4G10 4G16 4G25 4G35 4G50 4G70 4G95 4G120 4G150 4G185

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5 17,0

10,7 12,7 14,3 16,3 21,5 24,2 29,2 32,0 39,2 42,2 48,9 53,0 59,1 65,0

11,3 13,3 14,9 16,9 22,6 25,3 30,4 33,2 40,4 43,9 50,7 54,8 60,9 67,3

165 246 333 456 799 1082 1615 2075 3081 3938 5225 6400 7951 9722

90 150 240 360 600 960 1500 2100 3000 4200 5700 7200 9000 11100

FLAT CABLES Cores x cross section

Conductor Ø

Min height

Max height

Min width

Max width

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

mm

mm

kg/km

N

3G4 3G6 3G10 3G16 3G25 3G35 3G50 3G70 3G95

2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,5

7,0 7,5 9,9 12,0 14,0 16,0 18,5 20,5 23,1

8,0 8,5 10,9 13,0 15,0 17,5 20,0 22,0 23,9

15,5 17,5 22,9 28,0 33,0 37,0 44,1 50,5 57,1

16,5 18,5 23,9 29,0 34,0 38,7 45,8 52,5 57,9

250 325 535 780 1125 1555 2120 2850 3550

180 270 450 720 1125 1575 2250 3150 4275

4G4 4G6 4G10 4G16 4G25 4G35 4G50

2,4 2,9 3,8 4,8 6,1 7,2 8,9

8,0 8,5 10,0 12,0 15,8 18,6 19,4

9,0 9,5 11,0 13,0 17,2 19,4 20,2

23,0 24,5 29,5 34,5 42,1 48,6 56,8

24,0 25,5 30,5 35,5 43,5 49,8 57,6

395 470 710 1025 1600 2120 2770

240 360 600 960 1500 2100 3000

DRINCABLE® PLUS 450/750 V - DRINCABLE® PLUS 0,6/1 kV

ARISTONCAVI

34

35

ARISTONCAVI

D R I N C A B L E ® P LU S 0 7 / D R I N C A B L E ® P LU S 1 Based on AC spec. Electrical working data

ACS / K T W / W270 / WRAS / D.M. 174/04

Nominal rated voltage U 0 / U Test voltage Max AC voltage Max DC voltage Current rating

V - kV 450/750 - 0,6/1 kV 2,5 / 4 V - kV 520/900 - 0,7/1,2 kV 1,35 - 1,8 A

See table p. 59

3

2

Thermal working data 1

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Min ambient temperature

°C - 25

Max water temperature

°C + 80

Mechanical working data Bending radius* Maximum tensile load

Cable construction

mm ROUND: Static condition: 3 x D Mobile condition: 5 x D

FLAT: 3 x H ( for H ≤ 12 mm ) 4 x H ( for H > 12 mm ) N/mm

2

15

* (D = outer diameter) (H = height) 1

Phase Conductors

Conductor material Tinned copper Conductor construction

2

Insulation

Insulation material EPR compound: EI7 quality (450/750V ) acc.to EN 50363-1,

Outer Sheath

Chemical working data

3GI3 quality (0,6/1kV ) acc.to VDE 0207 par t 20

Cores identification 3

class 5 IEC 60228

According to HD 308 Material Special elastomeric compound 5GM3 (acc.to VDE 0207 par t 21) -

EM2 quality (acc.to EN 50363-2-1) (as far as applicable) Colour Blue

Applications Flexible NON TOXIC, WATERPR OOF and SUBMERSIBLE (up to 600 meters depth) elec tr ic cable, with special rubber insulation and outer sheath, suitable for per manent immersion in dr ink ing water. The exceptional per for mance of Ar istoncavi DRINCABLE® is provided by the unique and propr ietar y compound used the outer sheath. The cables have successfully passed r igorous testing and are fully qualified to the French ACS cer tification, Br itish WRAS, the G er man K T W and W270 for direc t and per manent immersion in potable water : the cable is also respec ting the I talian DM 174/04. The approval protocols have ver ified the absence of microbial growth, the water taste, appearance, transparenc y and colour and the absence of any metals or toxic substances. Elec tr ical parameters: according to HD 22.12 and BS 7919. On request DRINCABLE® is also available with a rated voltage of 0,6/1kV and in flat version (FL family). For submersible pumps for dr ink ing water, operation and control equipment in aquar iums, fish-ponds, operation of control, depuration/chlor ination systems installed in water main and dr ink ing water fountains, elec tr ical installations in manufac tur ing, processing and preser ving systems of dr inks and foodstuff, swimming pool lightings, depuration and cleaning system.

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

ARISTONCAVI

36

37

ARISTONCAVI

D R I N C A B L E ® P LU S 0 7 / D R I N C A B L E ® P LU S 1

ROUND CABLES Min overall Max overall Ø Ø

Cores x cross section

Conductor Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

1x1,5

1,5

5,1

5,8

35

23

1x2,5

1,9

5,8

6,5

55

38

1x4

2,4

6,6

7,3

70

60

1x6

2,9

7,4

8,1

100

1x10

3,8

8,9

9,6

1x16

4,8

9,9

1x25

6,1

1x35

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

4G1,5

1,5

9,8

10,5

130

90

4G2,5

1,9

11,6

12,3

200

150

4G4

2,4

13,2

13,9

280

240

4G6

2,9

15,0

15,7

390

360

4G10

3,8

18,0

18,7

600

600

4G16

4,8

20,2

21,2

840

960

4G25

6,1

25,5

26,5

1280

1500

4G35

7,2

28,4

29,4

1700

2100

4G50

8,9

33,7

34,8

2450

3000

4G70

10,6

38,8

39,9

3370

4200

4G95

12,5

44,2

45,9

4430

5700

FLAT CABLES Conductor Ø

Min height

Max height

Min width

Max width

Approx weight

Max tensile load

90

Cores x cross section

150

150

Nr x mm 2

mm

mm

mm

mm

mm

kg/km

N

10,6

210

240

11,2

11,9

290

375

3G1

1,2

5,8

6,8

11,5

12,5

100

45

7,2

12,7

13,4

390

525

3G1,5

1,5

6,0

7,0

12,1

13,1

120

68

1x50

8,9

14,8

15,5

560

750

3G2,5

1,9

6,7

7,7

14,2

15,2

170

113

1x70

10,6

17,1

17,8

780

1050

3G4

2,4

7,3

8,3

16,0

17,0

230

180

2,9

7,8

9,0

17,7

18,9

300

270

1x95

12,5

19,4

20,1

1010

1425

3G6

1x120

14,2

21,6

22,6

1290

1800

3G10

3,8

9,4

11,4

21,9

23,9

490

450

1x150

15,9

23,9

24,9

1590

2250

3G16

4,8

11,2

13,2

25,6

27,6

710

720

1x185

17,7

26,5

27,5

1970

2775

1x240

20,1

29,4

30,5

2550

3600

4G1

1,5

6,0

7,0

15,2

16,2

150

90

4G1,5

1,9

6,6

7,8

17,9

19,1

220

150

3G1,5

1,5

8,6

9,3

100

68

4G2,5

2,4

7,1

8,5

20,4

21,8

310

240

3G2,5

1,9

10,2

10,9

160

113

4G4

2,9

8,0

10,0

22,9

24,9

430

360

3G4

2,4

11,6

12,3

220

180

4G6

3,8

9,5

11,5

28,3

30,3

650

600

3G6

2,9

13,3

14,0

300

270

4G10

7,2

18,5

20,0

48,5

50,5

1920

2100

3G10

3,8

16,1

16,8

460

450

3G16

4,8

18,4

19,1

650

720

3x1 + 1G1

1,2

5,0

5,4

15,7

16,3

110

60

3G25

6,1

22,8

23,8

980

1125

3x1,5 + 1G1,5

1,5

5,2

5,6

16,5

17,1

140

90

3G35

7,2

25,7

26,7

1310

1575

3x2,5 + 1G2,5

1,9

6,0

6,4

20,1

20,7

200

150

3G50

8,9

30,2

31,3

1880

2250

3x4 + 1G4

2,4

6,8

7,2

22,9

23,5

290

240

3G70

10,6

34,8

35,9

2590

3150

3x8,4 + 1G8,4

3,6

8,4

8,8

29,3

29,9

510

504

H07RN-F OR

ARISTONCAVI

38

39

ARISTONCAVI

OERRE

Electrical working data

Based on HD 22.4

Nominal rated voltage U 0 / U Test voltage Max AC voltage Max DC voltage Current rating

V

450/750

kV 2,5 V

520/900

kV 1,35 A

See table p. 59

Thermal working data 3

2

Maximum short circuit temperature

°C 200

Maximum working temp. on the conductor

°C 60

Ambient temperature

°C - 25 to +50

1

Mechanical working data Bending radius* Maximum tensile load

mm Static condition: 4 x D, Mobile condition: 6 x D N/mm 2

15

* (D = outer diameter)

Chemical working data

Cable construction 1

Phase Conductors

Conductor material Conductor construction

2

Insulation Outer Sheath

class 5 IEC 60228

Insulation material Rubber compound

Cores identification 3

tinned copper

According to HD 308 Material Oil resistant rubber compound Colour Black

Applications For power and control, the cables can be installed in dr y, damp or wet environments, in polluted and oily environments and in hazardous environments (subjec t to local regulations).

Resistance to oil

According to IEC 60811-2-1

Ozone resistance

According to IEC 60811-2-1

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

Behaviour in water

Suitable for immersion in salt and brackish water

ARISTONCAVI

40

41

ARISTONCAVI

OERRE Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5 17,0 19,5 22,2

5,9 6,6 7,4 8,2 9,9 11,1 13,0 14,5 17,0 19,1 21,8 23,8 26,4 29,0 32,0 35,0

6,5 7,1 7,9 8,8 10,4 11,7 13,6 15,0 17,5 19,7 22,9 25,0 27,6 30,2 33,2 36,1

50 65 90 115 180 250 360 480 660 885 1140 1450 1740 2170 2650 3410

23 38 60 90 150 240 375 525 750 1050 1425 1800 2250 2775 3600 4500

2x1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1

7,7 8,6 10,2 11,6 13,2 17,8 20,2 24,0

8,2 9,2 10,8 12,1 13,8 18,4 21,3 25,2

90 110 165 220 295 525 715 1040

30 45 75 120 180 300 480 750

3G1 3G1,5 3G2,5 3G4 3G6 3G10 3G16 3G25 3G35 3G50 3G70 3G95 3G120

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8

8,6 9,6 11,4 13,0 14,6 19,7 22,5 26,5 29,6 33,2 39,7 45,0 49,0

9,2 10,1 12,0 13,6 15,1 20,3 23,6 27,7 30,7 34,4 40,9 46,7 50,8

110 145 210 290 380 680 940 1350 1790 2340 3300 4260 5320

45 68 113 180 270 450 720 1125 1575 2250 3150 4275 5400

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

3G150 3G185 3G240

15,5 17,0 19,5

53,9 58,0 66,9

55,7 59,7 69,2

6410 7730 9910

6750 8325 10800

4G1 4G1,5 4G2,5 4G4 4G6 4G10 4G16 4G25 4G35 4G50 4G70 4G95 4G120 4G150 4G185 4G240

1,3 1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,3 13,8 15,5 17,0 19,5

9,6 10,7 12,7 14,4 16,4 21,5 24,7 29,6 32,7 38,8 43,7 49,8 54,0 59,5 63,3 71,6

10,1 11,3 13,3 14,9 17,0 22,7 25,8 30,7 33,8 40,0 45,4 51,6 55,8 61,3 65,6 74,0

140 175 260 355 485 845 1170 1720 2260 3140 4190 5420 6730 8160 9760 12190

60 90 150 240 360 600 960 1500 2100 3000 4200 5700 7200 9000 11100 14400

5G1,5 5G2,5 5G4 5G6 5G10 5G16 5G25

1,50 1,90 2,40 2,90 3,80 4,80 6,10

11,8 13,9 15,8 18,2 23,7 27,5 32,7

12,3 14,5 16,4 18,8 24,9 28,6 33,8

220 320 440 310 1040 1460 2130

113 188 300 450 750 1200 1875

7G1,5 12G1,5 18G1,5 7G2,5 12G2,5 18G2,5

1,5 1,5 1,5 1,9 1,9 1,9

15,8 18,3 21,5 18,5 21,4 25,4

16,4 18,9 22,7 19,2 22,6 26,5

360 515 745 525 755 1080

158 270 405 263 450 675

07BN2-F

ARISTONCAVI

42

43

ARISTONCAVI

TERMALE

Electrical working data

Based on HD 22.12

Nominal rated voltage U 0 / U Test voltage Max AC voltage Max DC voltage Current rating

V

450/750

kV 2,5 V

520/900

kV 1,35 A

See table p. 59

Thermal working data 3

2

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Min ambient temperature

°C - 25

Max water temperature

°C + 85

1

Mechanical working data Bending radius Maximum tensile load

mm N/mm 2

according to VDE 0298 Par t 3 Static condition: 4 x D, Mobile condition: 6 x D 15

Chemical working data

Cable construction 1

Phase Conductors

Conductor material Conductor construction

2

Insulation Outer Sheath

class 5 IEC 60228

Insulation material EPR compound

Cores identification 3

tinned copper

According to HD 308 Material Chlorinated polyethylene based elastomer Colour Orange

Applications Specially designed cable for use in high temperature and chemically aggressive and ther mal water to 85°C at depth up to 100 meters. For power supplies of pumps. Also recommended for use in construc tion yards, mining and industr y.

Resistance to oil

According to IEC 60811-2-1

Ozone resistance

According to IEC 60811-2-1

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

ARISTONCAVI

44

45

ARISTONCAVI

TERMALE

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300

1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,5 14,2 15,9 17,7 20,1 22,5

5,9 6,6 7,4 8,2 9,9 11,1 13,0 14,5 17,0 19,1 22,0 24,1 26,7 29,3 32,3 39,5

6,5 7,1 7,9 8,8 10,4 11,7 13,6 15,0 17,5 19,7 23,1 25,3 27,9 30,5 33,4 40,7

55 70 90 120 185 255 365 490 670 900 1190 1470 1870 2260 2860 3510

23 38 60 90 150 240 375 525 750 1050 1425 1800 2250 2775 3600 4500

2x1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25

1,2 1,5 1,9 2,4 2,9 3,8 4,8 6,1

7,8 8,8 10,5 11,8 13,4 18,0 20,2 24,0

8,3 9,4 11,1 12,3 14,0 18,6 21,3 25,2

85 110 165 220 290 515 700 1010

30 45 75 120 180 300 480 750

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

3G1 3G1,5 3G2,5 3G4 3G6 3G10 3G16 3G25 3G35 3G50 3G70 3G95 3G120 3G150 3G185 3G240 3G300

1,2 1,5 1,9 2,4 2,9 3,8 4,8 6,1 7,2 8,9 10,6 12,5 14,2 15,9 17,7 20,1 22,5

8,5 9,5 11,3 12,8 14,4 19,4 21,8 25,8 28,2 33,2 37,2 42,7 46,6 51,8 57,0 63,8 70,6

9,1 10,0 11,9 13,4 14,9 20,0 22,9 26,9 29,3 34,4 38,4 44,4 48,4 53,6 58,8 66,1 73,0

105 135 200 275 365 645 890 1280 1660 2290 3050 4010 4930 6250 7580 9730 12030

45 68 113 180 270 450 720 1125 1575 2250 3150 4275 5400 6750 8325 10800 13500

(N)TSCGEWÖU

ARISTONCAVI

46

47

ARISTONCAVI

U R S U S ® M T S U B P LU S 3 , 6 / 6 ÷ 1 2 / 2 0 k V

Electrical working data

Based on DIN VDE 0250 Par t 813

Nominal rated voltage U 0 / U

kV

3,6/6

6/10

8,7/15

12/20

Test voltage

kV

11

17

24

29

Max AC voltage

kV

4,2/7,2

6,9/12

10,4/18

13,9/24

inner and outer semiconductive layers extruded in a single -pass with the insulation

Electrical field control Current rating

4

A

According to VDE 0298 Par t 4

Thermal working data

3

2

1

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Min ambient temperature

°C - 25

Max water temperature

°C 40

Mechanical working data Cable construction 1

Bending radius

Phase Conductors

Conductor material Conductor construction

tinned copper class 5 VDE 0295 (IEC 60228) (*)

Maximum tensile load*

mm N/mm

2

according to VDE 0298 Par t 3 20

* Referred to the total phase conductors cross section

Insulation material 3GI3 quality rubber compound, according to VDE 0207 Par t 20 Semiconductive layers 2

Earth Conductors

Conductor material Conductor construction Covering material

Central Filler

Material

Cores Assembly

Assembly

semiconductive tape over the conductor and inner and outer semiconductive rubber layer on the insulation tinned copper class 5 VDE 0295 (IEC 60228) (*) semiconductive layer semiconductive compound on textile polyester suppor t twisted cores with ear th conductor split into 3 par ts

Separator on the Semiconductive tape around the twisted cores twisted assembly 3

Inner Sheath

Material Thickness

4

Outer Sheath

Material Thickness

special EPR rubber compound water proofing GM1b quality, according to VDE 0207 Par t 21 according to VDE 0250 Par t 813 (table 2) special CM rubber compound water proofing 5GM3 quality, according to VDE 0207 Par t 21 according to VDE 0250 Par t 813 (table 2)

Colour Black * Special construction to get improved flexibility

Applications Heav y dut y flexible medium voltage power cable designed for per manent immersion in fresh or salt water where mechanical stress is lik ely. Suitable for immersion at depths to 300 meters. For pumps, dredgers, floating docks and for trailing operations with opencast mining equipment. The cable is unar moured and therefore is not suitable for under-water power transmission or installation in a water way or where mechanical damage is possible.

Chemical working data Resistance to oil

According to IEC 60811-2-1

Ozone resistance

According to IEC 60811-2-1

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

ARISTONCAVI

48

49

ARISTONCAVI

U R S U S ® M T S U B P LU S 3 , 6 / 6 ÷ 1 2 / 2 0 k V

Voltage

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

kV

Nr x mm 2

mm

mm

mm

kg/km

N

Voltage

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6

3x25 + 3x25/3 3x35 + 3x25/3 3x50 + 3x25/3 3x70 + 3x35/3 3x95 + 3x50/3 3x120 + 3x70/3 3x150 + 3x70/3 3x185 + 3x95/3

6,9 7,8 9,3 11,1 12,7 14,5 16,7 17,6

39,9 42,9 46,0 49,8 55,8 59,6 66,0 67,9

41,6 44,6 47,7 51,6 57,6 61,4 68,3 70,2

2580 3080 3710 4670 5880 7140 8690 9890

1500 2100 3000 4200 5700 7200 9000 11100

kV

Nr x mm 2

mm

mm

mm

kg/km

N

6/10 6/10 6/10 6/10 6/10 6/10 6/10

3x25 + 3x25/3 3x35 + 3x25/3 3x50 + 3x25/3 3x70 + 3x35/3 3x95 + 3x50/3 3x120 + 3x70/3 3x150 + 3x70/3

6,9 7,8 9,3 11,1 12,7 14,5 16,7

39,9 42,9 46,0 49,8 55,8 59,6 66,0

41,6 44,6 47,7 51,6 57,6 61,4 68,3

2580 3080 3710 4670 5880 7140 8690

1500 2100 3000 4200 5700 7200 9000

8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15

3x25 + 3x25/3 3x35 + 3x25/3 3x50 + 3x25/3 3x70 + 3x35/3 3x95 + 3x50/3 3x120 + 3x70/3 3x150 + 3x70/3 3x185 + 3x95/3

6,9 7,8 9,3 11,1 12,7 14,5 16,7 17,6

47,3 48,8 53,7 57,5 60,8 66,4 71,0 73,1

49,0 50,6 55,5 59,3 63,1 68,7 73,4 75,5

3310 3680 4580 5600 6550 8130 9460 10700

1500 2100 3000 4200 5700 7200 9000 11100

6/10

3x185 + 3x95/3

17,6

67,9

70,2

9890

11100

12/20 12/20 12/20 12/20 12/20 12/20

3x25 + 3x25/3 3x35 + 3x25/3 3x50 + 3x25/3 3x70 + 3x35/3 3x95 + 3x50/3 3x120 + 3x70/3

6,9 7,8 9,3 11,1 12,7 14,5

52,0 55,2 58,4 62,1 67,2 71,0

53,8 57,0 60,2 64,4 69,5 73,4

3830 4440 5170 6250 7480 8840

1500 2100 3000 4200 5700 7200

NTSCGECEWOU

ARISTONCAVI

50

51

ARISTONCAVI

U R S U S ® M T S U B - E 1 ,8 /3 ÷ 1 2 / 2 0 k V

Electrical working data

DIN VDE 0250 Par t 813 approved

Nominal rated voltage U 0 / U

kV

1,8/3

3,6/6

6/10

8,7/15

12/20

Test voltage

kV

6

11

17

24

29

Max AC voltage

kV

2,1/3,6

4,2/7,2

6,9/12

10,4/18

13,9/24

inner and outer semiconductive layers extruded in a single -pass with the insulation and the screen over each conductor

Electrical field control Current rating

A

According to VDE 0298 Par t 4

Thermal working data

4

2 3

1

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Min ambient temperature

°C - 25

Max water temperature

°C 40

Mechanical working data Bending radius

Cable construction

Maximum tensile load* 1

Phase Conductors

Conductor material Conductor construction

tinned copper

Semiconductive layers 2

Protective Earth Conductors

material construction

Central Filler

Material

Cores Assembly

Assembly

according to VDE 0250 Par t 813 table 1

Inner Sheath

Material Thickness

4

Outer Sheath

Material Thickness

15

* Referred to the total phase conductors cross section

Chemical working data Resistance to oil

According to IEC 60811-2-1

bare copper

Ozone resistance

According to IEC 60811-2-1

individual copper braid

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Weather resistance

For indoor and outdoor application

Burning behaviour

According to IEC 60332-1-2

rubber compound on textile polyester suppor t twisted cores with ear th conductor split into 3 par ts

special EPR rubber compound water proofing GM1b quality, according to VDE 0207 Par t 21 according to VDE 0250 Par t 813 (table 2) special CM rubber compound water proofing 5GM3 quality, according to VDE 0207 Par t 21 according to VDE 0250 Par t 813 (table 2)

Colour Black * Special construction to get improved flexibility

Applications Heav y dut y flexible medium voltage power cable with individually copper braid screened cores. D esigned for per manent immersion in fresh or salt water where mechanical stress is lik ely. Suitable for immersion at depths to 300 meters. For pumps, dredgers, floating docks and for trailing operations with opencast mining equipment. The cable is unar moured and therefore not suitable for under-water power transmission or installation in a water way or where mechanical damage is possible.

according to VDE 0298 Par t 3

semiconductive tape over the conductor and inner and outer semiconductive rubber layer on the insulation (from 3,6/6 kV )

Separator on the 1,8/3 kV: TNT tape around the twisted cores twisted assembly From 3,6/6 kV: semiconductive tape around the twisted cores 3

N/mm

2

class 5 VDE 0295 (IEC 60228) (*)

Insulation material 3GI3 quality rubber compound, according to VDE 0207 Par t 20 Insulation thickness

mm

ARISTONCAVI

52

53

ARISTONCAVI

U R S U S ® M T S U B - E 1 ,8 /3 ÷ 1 2 / 2 0 k V

Voltage kV

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm

mm

mm

mm

kg/km

N

2

1,8/3 1,8/3 1,8/3 1,8/3 1,8/3 1,8/3 1,8/3 1,8/3

3x25 + 3x25/3e 3x35 + 3x25/3e 3x50 + 3x25/3e 3x70 + 3x35/3e 3x95 + 3x50/3e 3x120 + 3x70/3e 3x150 + 3x70/3e 3x185 + 3x95/3e

6,8 7,8 9,4 11,2 12,7 14,4 16,3 17,6

39,3 40,7 43,8 49,4 54,5 59,1 65,5 67,4

41,3 43,6 46,7 52,4 57,5 62,1 69,4 71,4

2420 2790 3380 4520 5660 6940 8520 9750

1125 1575 2250 3150 4275 5400 6750 8325

3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6

3x25 + 3x25/3e 3x35 + 3x25/3e 3x50 + 3x25/3e 3x70 + 3x35/3e 3x95 + 3x50/3e 3x120 + 3x70/3e 3x150 + 3x70/3e

6,8 7,8 9,4 11,2 12,7 14,4 16,3

46,6 48,0 53,0 56,8 60,5 66,9 71,6

49,5 51,0 56,0 59,8 64,4 70,9 75,6

3120 3510 4350 5400 6450 8070 9360

1125 1575 2250 3150 4275 5400 6750

Voltage

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

kV

Nr x mm 2

mm

mm

mm

kg/km

N

6/10 6/10 6/10 6/10 6/10 6/10

3x25 + 3x25/3e 3x35 + 3x25/3e 3x50 + 3x25/3e 3x70 + 3x35/3e 3x95 + 3x50/3e 3x120 + 3x70/3e

6,8 7,8 9,4 11,2 12,7 14,4

49,4 50,9 55,8 59,6 63,3 69,8

52,4 53,9 58,8 62,6 67,2 73,8

3410 3810 4670 5690 6830 8510

1125 1575 2250 3150 4275 5400

8,7/15 8,7/15 8,7/15 8,7/15 8,7/15

3x25 3x35 3x50 3x70 3x95

+ + + + +

3x25/3e 3x25/3e 3x25/3e 3x35/3e 3x50/3e

6,8 7,8 9,4 11,2 12,7

55,5 56,9 60,0 66,0 69,8

58,5 59,9 63,9 69,9 73,8

4100 4490 5210 6570 7740

1125 1575 2250 3150 4275

12/20 12/20 12/20 12/20

3x25 3x35 3x50 3x70

+ + + +

3x25/3e 3x25/3e 3x25/3e 3x35/3e

6,8 7,8 9,4 11,2

59,7 61,0 66,0 69,8

63,6 64,9 69,9 73,8

4620 5020 6050 7150

1125 1575 2250 3150

DRINCABLE® MT PLUS 3,6/6 kV

ARISTONCAVI

54

55

ARISTONCAVI

D R I N C A B L E ® M T P LU S 3 , 6 / 6 k V Based on DIN VDE 0250 Par t 813 ACS / WRAS / D.M. 174/04 Electrical working data

3

Nominal rated voltage U 0 / U

kV 3,6/6

Test voltage

kV 11

Max AC voltage

kV 4,2/7,2

Electrical field control

kV

Current rating

A

inner and outer semiconductive layers extruded in a single -pass with the insulation According to VDE 0298 Par t 4

2

1

Cable construction 1

Phase Conductors

Conductor material Conductor construction

Semiconductive layers 2

Earth Conductors

Conductor material Conductor construction Covering material

Central Filler

Material

Cores Assembly

Assembly Separator on the twisted assembly

3

Outer Sheath

Maximum short circuit temperature

°C 250

Maximum working temp. on the conductor

°C 90

Min ambient temperature

°C - 25

Max water temperature

°C 40

tinned copper class 5 VDE 0295 (IEC 60228) (*)

Insulation material 3GI3 quality rubber compound, according to VDE 0207 Par t 20 Insulation thickness

Thermal working data

Mechanical working data

according to VDE 0250 Par t 813 table 1 semiconductive tape over the conductor and inner and outer semiconductive rubber layer on the insulation tinned copper

Bending radius

mm

Maximum tensile load*

N/mm

2

according to VDE 0298 Par t 3 15

* Referred to the total phase conductors cross section

class 5 VDE 0295 (IEC 60228) (*) semiconductive layer semiconductive compound on textile polyester suppor t

Chemical working data

twisted cores with ear th conductor split into 3 par ts Semiconductive tape around the twisted cores

Behaviour in water

HD 22.16 and AC internal test, suitable for immersion in salt and brackish water

Material Special cross-linked compound, EM6 quality

according to EN 50363-2-1 Thickness

according to VDE 0250 Par t 813 (table 2)

Colour Blue * Special construction to get improved flexibility

Cores x cross section

Conductor Ø

Min overall Ø

Max overall Ø

Approx weight

Max tensile load

Nr x mm 2

mm

mm

mm

kg/km

N

3x25 + 3x25/3 3x35 + 3x25/3 3x50 + 3x25/3 3x70 + 3x35/3 3x95 + 3x50/3 3x120 + 3x70/3 3x150 + 3x70/3 3x185 + 3x95/3

6,8 7,8 9,4 11,2 12,7 14,4 16,3 17,6

39,9 42,9 46,0 49,8 55,8 59,6 66,0 67,9

41,6 44,6 47,7 51,6 57,6 61,4 68,3 70,2

2580 3080 3710 4670 5870 7130 8690 9880

1125 1575 2250 3150 4275 5400 6750 8325

Applications Flexible energy supply cable for use in permanent immersion in drinking water, rain water, cooling water, sea water, river water and in environmentally sensitive environments. The exceptional performance of Aristoncavi DRINCABLE® MT PLUS is provided by the unique and proprietar y compounds used for the outer sheath. The cables have successfully passed rigorous testing and are fully qualified to the British WRAS certification (according to BS 6920), the French ACS certification for direct and permanent immersion in potable water and are respecting the Italian DM 174/04. The approval protocols have verified the absence of microbial growth, the water taste, appearance, transparency and colour and the absence of any metals or toxic substances. Suitable for power supply to pumps, dredgers, floating docks and can be used for immersion at depths to 300 meters. Beeing the cable unarmoured, it is not suitable for under-water power transmission or installation in a water way or where mechanical damage is possible.

Te ch n i ca l d a t a .

Electrical resistance and phase reactance CURRENT CARRYING CAPACIT Y CHEMICAL RESISTANCE

ARISTONCAVI

E l e c t r i ca l re sist a nce an d p h a se re a ct ance.

Flexible conductors

59

ARISTONCAVI

Current carr y i ng capac i t y.

R Electrical resistance Ω/Km at 20°C (according to IEC 60228 - VDE 0295) Cross-section mm²

58

X Phase reactance at 50 HzΩ/Km

Solid conductors

Single core cables

Multicore cable

Conductor service temperature 90 °C Ambient air/water temperature 30 °C 3 - 4 cores cables 3 cores loaded

ROUND CABLES

Bare copper

Tinned copper

Bare copper

Tinned copper

1.5

13,30

13,70

12,10

12,20

0,168

0,118

2.5

7,98

8,21

7,41

7,56

0,155

0,109

4

4,95

5,09

4,61

4,70

0,143

0,101

6

3,30

3,39

3,08

3,11

0,135

0,0955

10

1,91

1,95

1,83

1,84

0,119

0,0861

16

1,21

1,24

1,15

1,16

0,112

0,0817

25

0,780

0,795

0,727

0,734

0,106

0,0813

35

0,554

0,565

0,524

0,529

0,101

0,0783

50

0,386

0,393

0,387

0,391

0,101

0,0779

70

0,272

0,277

0,268

0,270

0,0965

0,0751

95

0,206

0,210

0,193

0,195

0,0975

0,0762

120

0,161

0,164

0,153

0,154

0,0939

0,0740

150

0,129

0,132

0,124

0,126

0,0928

0,0745

185

0,106

0,108

0,0991

0,100

0,0908

0,0742

240

0,0801

0,0817

0,0754

0,0762

0,0902

0,0752

300

0,0641

0,0654

0,0601

0,0607

0,0895

0,0750

400

0,0486

0,0495

0,0470

0,0475

0,0876

0,0742

500

0,0384

0,0391

0,0366

0,0369

0,0867

0,0744

630

0,0287

0,0292

0,0283

0,0286

0,0865

0,0749

FLAT CABLES

Cross section

Laying in free air

Laying in water

Laying in free air

Laying in water

Max short circuit current

mm 2

A

A

A

A

kA

1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

23 32 42 54 75 100 127 158 192 246 298 346 399 456 538 621

29 38 52 67 94 125 166 205 256 316 377 438 505 577 681 785

24 33 45 58 80 107 141 176 216 279 342 400 464 533 634 736

29 38 52 67 94 125 166 205 256 316 377 438 505 577 681 785

0,24 0,40 0,64 0,95 1,95 2,54 3,98 5,57 7,98 11,1 15,2 19,2 24,0 29,6 38,4 48

ARISTONCAVI

60

61

ARISTONCAVI

C h e m i ca l re sist a nce.

wine

water - waste industrial

water - sewerage

water - sea

water - fresh

turpentine

toluene

soda

salt solution

nitrates, sulphates

milk

kerosene

hydrochloric acid

gasoline

ethylene glycol

ethanol

diesel

benzene

ammonium chloride

acetic acid

acetic acid - solution 30%

other liquid resistance

turbine oil

soybean oil

silicon oil

red oil (MIL-H-5606)

olive oil

linseed oil

vegetable oil

transformer oil

mineral oil

oil resistance (by type name)

hydraulic oil

MIL-H-5606 B

MIL-L46000 A

MIL-L21568 A

MIL-C-4339 C

MIL-L-3545 B

MIL-L3503

MIL-L-3150 A

MIL-G-2108

MIL-L-2104 B

MIL-L-644 B

Mineral oil test EN60811-2-1

oil resistance (by Specification Number)

S UB M ER SI B L E

Y ES

SU BME RSI BLE

S UB M ER SI B L E S

Y ES

SU BME RSI BLE S

S UB F L AT

Y ES

SU BFLAT

S N AK EF L EX

Y ES

SNA KE FLE X

N AUT I LU S 5 0 0

Y ES

NAU TI LU S 5 0 0

N AUT I LU S 5 0 0 S

Y ES

NAU TI LU S 5 0 0 S

MA R INE

NO

MA RI NE

DR I NC ABL E®

NO

D RI NCA BLE ®

DR I NC ABL E® PLUS

NO

D RI NCA BLE ® P LU S

O E R RE

NO

OE RRE

T ER MAL E

Y ES

TE RMA LE

URSUS® MT SUB PLUS

Y ES

U RSU S® MT SU B P LU S

U R S U S® MT SU B -E

Y ES

U RSU S® MT SU B-E

DRINCABLE® MT PLUS

Y ES

DRINCABLE® MT PLUS

little influence on the material (suitable for use, for prolonged contact or immersion)

moderate deterioration of the characteristics (fit for use)

characteristics severe decay (use not recommended: eventually to be checked conditions and timing of contact)

not usable

to be verified in relation to the chemical main components

CSQ: this certified that Aristoncavi S.p.A. implements a quality system in conformity with the standard UNI EN ISO 9001 to ensure quality in design, development, manufacture, selling/marketing and installation of the product.

03/2012

Ar i sto nc avi S.p.A . 36040 brendo la , vicenza , it a ly, via ein a u d i 8, t. + 39 0444 7 4 9 9 0 0 , f. + 3 9 0 4 4 4 7 4 9 8 0 0 , w w w. a r i s to n c av i . co m, i n fo @ a r i s tonc av i . com