3G Alarms & Solutions ALARM 1: Synchronization (RBS) ALARM 2: Device_AntennaSystemProblem ALARM 3: Loss of Cell Delineat

Views 254 Downloads 18 File size 369KB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

Citation preview

3G Alarms & Solutions ALARM 1: Synchronization (RBS) ALARM 2: Device_AntennaSystemProblem ALARM 3: Loss of Cell Delineation ALARM 4: Carrier_RXDiversityLost ALARM 5: Device_AntennaSystemProblem or TmaDevice_AntennaSystemProblem ALARM 6: Carrier_RejectSignalFromHardware ALARM 7: RuDeviceGroup_GeneralHWError ALARM 8: Device_ExternalUnitFailure ALARM 9: ExternalTma_LnaFailureBranchA ALARM 10: Nbap (in RNC) OR Equipment for RUDeviceGroup (in RBS) ALARM 11: Carrier_UL_GainProblem ALARM 12: Carrier_UL_GainTruncated ALARM 13: AuxPlugInUnit_PiuConnectionLost ALARM 14: Tma_LnaFailure ALARM 15: CLU_LossofMain ALARM 16: FCU_DeviceGroup_NumberofHWEntitiesMismatch ALARM 17: FCU_DeviceGroup_FanFailure ALARM 18: RXDiversityLoss ALARM 19: CarrierReject ALARM 20: IMAGroupInsufficientLinks ALARM 21: PSUDeviceGroup_GeneralSWError ALARM 22: Carrier_SingalNotReceivedWithinTime ALARM 23: Bfu_BatteryChargingFailure ALARM 24: UtranCell_NbapMessageFailure (in RNC) ALARM 25: UtranCell_NbapMessagefailure (RNC) ALARM 26: RBS_LocalCellnotAdded (RNC) or NBapMessageFailure (RNC) ALARM 27: UtranCell_InternalResourceUnavailable or UtranCell_NbapMessageFailure

Go to Top

Page 1

ALARM 28: Antenna alarms pointing to one sector ALARM 29: ExternalTMA_degraded/Failed ALARM 30: Carrier Diversity Failed/Degraded ALARM 31: IMA UNUSABLE ALARM 32: Carrier_ULGainTruncated ALARM 33: Loss of Tracking & Loss of Synch Reference Redundancy ALARM 34: Switch Core Fault or PsDevice_LossOfMains ALARM 35: Exceeded Maximum limit ALARM 36: Node Status Analyzer doesn’t open ALARM 37: RfCable_Disconnected equipment_malfunction ALARM 38: loss_of_signal ALARM 39: TU Synch Reference Loss of Signal loss_of_signal ALARM 40: AuxPlugInUnit_NewAuxiliaryUnitDetectedNotCorrespondingToTheDefinedConfigurati on

ALARM 1: Synchronization (RBS) Mostly synchronization alarms are one of the following Loss of Tracking TU Synch Reference Loss of Signal PDH Loss of Signal or PDH Loss of Frame or only Loss of Signal or Loss of Frame In most cases, the node lost one of the synchronization references and the node needs to be resynched TU Synch Reference Loss of Signal: TUB or CBU doesn’t get the signal check the input port, cables, boards themselves Loss of Tracking: Node is not in locked mode but in holdover mode "resetLossOfTracking" on Sync MO (use LDN of pp1 and pp2 which are the sync references

Go to Top

Page 2

PDH Loss of Signal/Frame or Loss of Signal/Frame: ET doesn’t detect the signal check port, cables, board (put cable between Tx and Rx on the ET), if everything is ok, then remove this port from the sync reference

ALARM 2: Device_AntennaSystemProblem Use the following RBS command: Moshell lt antennabranch get antennabranch antennaSupervisionThreshold lt tma get tma power In the RBS there is feature to measure the VSWR (Voltage Standing Wave Ratio). In simple words, the VSWR is a measure of the reflection in the RF path caused by faulty equipment between the RBS and the Antenna. In case of non-TMA sites, the RBS has another feature call DC resistance. See the following table to see which features are used for the US market.

Table: Valid for FU12 19 and FU12 08, - = not supported Configuration/Supervision Feeder Power Supply SV DC Antenna SV VSWR Antenna SV TMA SV A B A B 1. Only antenna No No Yes Yes No 2. RET/RIU, no ASC/TMA Yes, branch A No Yes Yes No

Go to Top

Page 3

3.TMA, external power supply No No No Yes No 4. TMA, power supply by FU/AIU Yes No No Yes Yes 5. ASC Yes No No No No

Note: Observe that when TMA is defined Branch B has NO supervision. If the antennasupervisionthreshold is not set correctly (general value is 49) then we see this alarm. The formula for the different types of supervision is in MOP and given below as well: The threshold value 0 means that the supervision is turned off. In this case ask the ASP to put dummy loads on the RBS to eliminate alarms with the Antenna. Set the AntennaSupervision Threshold in Branch B to 0 for all the sectors to get rid of this alarm. This is because the feeder cable is shared by the 1900 and the 850, and the 1900 powers the TMA (15V) through the jumper cables thus interfering with the 850 branch B antenna supervision readings (tests for DC resistance) triggering the alarm.

Go to Top

Page 4

ALARM 3: Loss of Cell Delineation This can happen for the IMA link or the separate E1 check status of E1s, their cross connection, configuration check the link performance (ES and SES) on E1PhysPathTerm for that link, if the numbers are increasing, then the network is not stable, if it is not increasing, then there might be a HW issue (ET board) ET port might be hanging, thus restart the port

ALARM 4: Carrier_RXDiversityLost This alarm will cause a degraded carrier check whether the RU or FU is locked if connection is ok, try to restart the port for that sector "lhsh 001200/xxx restart" might be combined with antenna alarm (AiDevice_AntennaSystemProblem or TmaDevice_AntennaSystemProblem)

ALARM 5: Device_AntennaSystemProblem or TmaDevice_AntennaSystemProblem Which alarm shows up depends on whether the antenna is connected to a TMA check the antenna, jumper cables, cable connections visually and also by swapping them among the sectors and see whether alarm moves check FU check the value of the supervision parameter (should be 49, but if set to 0 no alarm is reported) restart the RU

ALARM 6: Carrier_RejectSignalFromHardware This alarm is issued from several HW, mainly RU, TXboard and RRU insert new HW if this doesn’t help reboot the RBS (there has been a CSR which requires reboot)

Go to Top

Page 5

ALARM 7: RuDeviceGroup_GeneralHWError This alarm indicates problems with the component (written at beginning of alarm, in this case RU) restart RU port, restart whole RU board if doesn’t help, replace RU Cable between RU and FU disconnected - Plug back in and restart boards with restart aux unit command

ALARM 8: Device_ExternalUnitFailure This alarm appears if the feeder or jumper cable is connected incorrectly or damaged or the TMA can be faulty check the antenna, jumper cables, cable connections visually and also by swapping them among the sectors and see whether alarm moves check the TMA ALARM 9: ExternalTma_LnaFailureBranchA This alarm comes up when the two transistors amplifying the RF signals in the TMA fail. The cell can still carry traffic as long as branch B is working, however, the RX might be degraded. => run script to modify the TMA parameters Make sure the currentHighLimA TMA parameter is set to 180 just like the currentHighLimB.

ALARM 10: Nbap (in RNC) OR Equipment for RUDeviceGroup (in RBS) Check with Moshell the equipment view for the RBS Restart the specific RU/FU in RBS Subrack ALARM 11: Carrier_UL_GainProblem Check attenuation , RBS needs one of each, DPCL, TPA, TR ALARM 12: Carrier_UL_GainTruncated Check whether feeder loss is outside the acceptable range (max is 6db) Check power Are RU boards steady

Go to Top

Page 6

ALARM 13: AuxPlugInUnit_PiuConnectionLost Piu powered off? Cable problem? FU/RU? => Check "cabx" EC BUS disconnected Power to FCU was cut ALARM 14: Tma_LnaFailure Check voltage (what TMA gives out), if too low => check FU (bad or short circuit) => restart FU if 0 => check if internalpower is set to yes (in ExternalTma MO) check current (what antenna pulls out) => c heck if also AiDevice (antenna) alarm ALARM 15: CLU_LossofMain Lost power, node is in backup mode ALARM 16: FCU_DeviceGroup_NumberofHWEntitiesMismatch Was HW replaced? It then might have a different revision => restart PluginunitMO for that piece ALARM 17: FCU_DeviceGroup_FanFailure 1 FCU has fan, if enabled and unlocked, restart it ALARM 18: RXDiversityLoss Check if FU Is locked or the RX cable has been pulled out ALARM 19: CarrierReject If HSDPA is enabled, disable it, the alarm will then go away ALARM 20: IMAGroupInsufficientLinks IMAGroupInsufficientLinksatFarEnd IMA is usually disabled, but IMA link is enabled => delete/recreate IMA, if that doesn’t help, => or lock the active board (force it to go over to the redundant one), unlock after (so it goes back) => or reset the processor on board

Go to Top

Page 7

ALARM 21: PSUDeviceGroup_GeneralSWError restart PSUDeviceGroup ALARM 22: Carrier_SingalNotReceivedWithinTime i.e. Sector=1, Carrier=1 => is TXboard up? => disable HSDPA, txdevicegroup on slot 10

ALARM 23: Bfu_BatteryChargingFailure check voltage on battery, should be around 50V, if not "acc restartAuxUnit AuxPlugInUnit" (from PS1) ALARM 24: UtranCell_NbapMessageFailure (in RNC) AIDevice_ExternalUnitFailure + CarrierRejectSignalFromHW (in RBS) Check if antenna feeder is too low Check FU ALARM 25: UtranCell_NbapMessagefailure (RNC) Ai_Device_ExternalUnitFailure (RBS, equipment malfunction, FU… aidevice=1) Carrier_RejectSignalFromHardware (RBS) In RBS t&e: antennafeeder low/high turn off TMA power ALARM 26: RBS_LocalCellnotAdded (RNC) or NBapMessageFailure (RNC) RBS has no alarms cells are disabled, in RBS, txboard is down ALARM 27: UtranCell_InternalResourceUnavailable or UtranCell_NbapMessageFailure workaround to reload the module where the RBS is The module can be found in the properties of the RBS in EMAS under iub_links in the Radio Network view. Or it can be found using Moshell on the RNC >pr iublink

Go to Top

Page 8

Find the RBS in the list and do a get on it. ALARM 28:Antenna alarms pointing to one sector

To segregate whether the fault is in the feeder cable or the hardware, we need to swap the feeder cable on FU from one sector to another and see if the fault moves too. If Yes, then its definitely a fault in the Feeder cable. If not, then the fault should be in the FU board and it should be replaced. ALARM 29: ExternalTMA_degraded/Failed Moshell cabx # The cabx printout has PORT information at the end. # For a 3 sector site there are 6 PORT information. One line for # RU and FU devices (3 RU+3FU). The printout shows the port, for example, ==================================== SMN APN PORT BOARD ==================================== 0 12 port_0_dev_8 RU22 0 12 port_0_dev_8 FU 0 12 port_4_dev_9 RU22 0 12 port_4_dev_9 FU 0 12 port_8_dev_10 RU22 0 12 port_8_dev_10 FU -----------------------------------lhsh 001200/port_x_dev_yy fui get devstat # get port information from cabx Ensure that the devstat printout from above has ~16000mV for each sector and the current is between 50mA-200mA, if and only if the site has TMAs defined and is being powered by the UMTS RBS (MO:externalTMA, Attribute:internalpower). Each RBS in the US market, has threshold when this alarm is generated. These thresholds are input into the RBS using scripts. The thresholds vary for single band TMAs and dual band TMAs. Make sure that the right threshold is set for the type of TMA. acc SystemConstants=1 writeConst

Go to Top

Page 9

y 300 00001 acc SystemConstants=1 writeConst y 301 135 acc SystemConstants=1 writeConst y 302 270 acc SystemConstants=1 writeConst y 303 135 acc SystemConstants=1 writeConst y 304 270

ALARM 30: Carrier Diversity Failed/Degraded In the RBS antenna branch A is TX/RX while branch B is RX only. Hence there are two RX paths (RX diversity). The RBS monitors the two RX paths and compares the signal received from both of these paths. If there is significant "mismatch" between these paths (like TMA failure on branch B. Remember branch B has no supervision) then this alarm is generated. This alarm is suppressed if there is a higher priority alarm such as the AI_Device_antenna_system_problem. Give lgar command in moshell to see if this alarm was raised and suppressed. ALARM 31: IMA UNUSABLE Alarms on RBS Symptom:

Go to Top

Page 10

Warn IMA Link Reception Unusable at Far End remote_node_transmission_error ImaGroup=1-1-ima1,ImaLink=3 Warn IMA Link Reception Unusable at Far End remote_node_transmission_error ImaGroup=1-1-ima1,ImaLink=4 Warn IMA Link Transmit Unusable at Far End remote_node_transmission_error ImaGroup=1-1-ima1,ImaLink=3 Warn IMA Link Transmit Unusable at Far End remote_node_transmission_error ImaGroup=1-1-ima1,ImaLink=4 Warn Remote Defect Indication on IMA Link remote_node_transmission_error ImaGroup=1-1-ima1,ImaLink=3 Warn Remote Defect Indication on IMA Link remote_node_transmission_error ImaGroup=1-1-ima1,ImaLink=4 Solution: Make a cv on the RBS and cold restart RBS to clear alarms for imalink=3 and imalink=4. cvms acc 0 restart ALARM 32: Carrier_ULGainTruncated Symptoms The RBS sectors which have long feeder cables with feeder loss bigger than 6db get alarm Carrier_ULGainTruncated, Bad Coverage on UE The parameter ulfeederAtteunation should be set according to the actual feeder length, even if the feeder attenuation is greater than 6db. The problem occurs at sites with feeder losses bigger than 6dB and it is the entered feeder loss value that triggers this alarm. The alarm doesn't point out a real error (except in the case that the operator enters a value that are bigger than 6dB by mistake), its more of an information that the feeder are large and performance can get degraded with large feeder losses. REMEDY: This is a warning alarm issued when the UL amplification internally in the RBS cannot compensate for the attenuation in the Antenna Feeder Cable. Optimal sensitivity is no longer obtained. Nothing in the RBS changes state because of this situation and trafic handling continues. The external attenuation, that is the combination of the gain of the TMA and the UL Attenuation of the Antenna Feeder (AntFeederCable), is larger than what the Low Noice Amplifier (LNA) on the FU can compensate for. When that situation arise, the alarm Carrier_ULGainTruncated is issued. Accept the presence of the warning alarm. The ulAttenuation of AntennaFeederCable shall not be changed to a false value, as that impacts the power measurements.

Go to Top

Page 11

In most of the cases this alarm will be planned to be removed in a later sw revision on the RBS. ALARM 33: Loss of Tracking & Loss of Synch Reference Redundancy

RBS> alt 1969-12-31 21:44:18 M Loss of Tracking replaceable_unit_problem Synchronization=1 1969-12-31 21:45:18 w Loss of Synch Reference Redundancy replaceable_unit_problem Synchronization=1 RBS> lpr sync ============================================================================= ===== Proxy MO ============================================================================= ===== 102 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,TimingUnit=1,TuSyncRef=1 1035 TransportNetwork=1,Synchronization=1 1102 NodeBFunction=1,RBSxxxSynchronization=1 1164 NodeBFunction=1,Iub=RBS,NodeSynchTp=1 RBS> get 1035 ============================================================== 1035 TransportNetwork=1,Synchronization=1 ============================================================== SynchronizationId 1 degradationIsFault 0 (degrNotFault) syncRefActivity i[8] = 1 2 1 1 1 1 1 1 syncRefPriority i[8] = 1 2 0 0 0 0 0 0 syncRefStatus i[8] = 2 3 0 0 0 0 0 0 syncReference [8] = >>> syncReference = Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,Etmc1=1,E1PhysPathTerm=pp1

Go to Top

Page 12

>>> syncReference = Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,Etmc1=1,E1PhysPathTerm=pp2 >>> syncReference = >>> syncReference = >>> syncReference = >>> syncReference = >>> syncReference = >>> syncReference = systemClockA 2 (lockedMode) systemClockB 7 (notApplicable) systemClockRedundancy 0 (SYSTEM_CLOCK_USERS_USE_PLANE_A) userLabel ============================================================================= ===== Total: 1 MOs RBS> acl 1035 ============================================================================= ===== Proxy MO Action Nr of Params ============================================================================= ===== 1035 Synchronization=1 addSyncRefResource 2 1035 Synchronization=1 changeSyncRefPriority 2 1035 Synchronization=1 removeSyncRefResource 1 1035 Synchronization=1 resetLossOfTracking 1 ============================================================================= ===== RBS> acc 1035 resetLossOfTracking ============================================================================= ===== 1035 TransportNetwork=1,Synchronization=1

Go to Top

Page 13

============================================================================= ===== Are you Sure [y/n] ? y ============================================================================= ===== Proxy MO Action Nr of Params ============================================================================= ===== 1035 Synchronization=1 resetLossOfTracking 1 Parameter 1 of 1, syncReference (moRef-ManagedObject): Enter mo LDN: Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,Etmc1=1,E1PhysPathTerm=pp1 >>> Return value = null ============================================================================= =====Total: 1 MOs attempted, 1 MOs actioned RBS> acc 1035 resetLossOfTracking ============================================================================= =====1035 TransportNetwork=1,Synchronization=1 ============================================================================= ===== Are you Sure [y/n] ? y ============================================================================= ===== Proxy MO Action Nr of Params ============================================================================= ===== 1035 Synchronization=1 resetLossOfTracking 1 Parameter 1 of 1, syncReference (moRef-ManagedObject): Enter mo LDN: Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,Etmc1=1,E1PhysPathTerm=pp2 >>> Return value = null ============================================================================= ===== Total: 1 MOs attempted, 1 MOs actioned

Go to Top

Page 14

RBS> alt Alarm should be gone. ALARM 34: Switch Core Fault or PsDevice_LossOfMains Several ASPs lock sectors on their end. However, when they do so, some of them will block other components by chance. This will throw alarms such as the ones mentions above. Switch Core Fault: they blocked one of the redundancy slots. PsDevice_LossOfMains: they tampered with the PCU.

ALARM 35: RbsLocalCell_ConfiguredLimitExceedsLicensedLimit unavailable The cell range isn’t set prorerly. Block the cells on the RNC On the RBS, set the cell range with command set cell cellrange 35000 For e.g RBS> alt Starting to retrieve active alarms Nr of active alarms are: 23 ============================================================================= ======================================= Date & Time (Local) S Specific Problem MO (Cause/AdditionalInfo) ============================================================================= ======================================= 2012-08-08 16:40:39 m Emergency Unlock of Software Licensing Licensing=1 (Emergency state is activated) 2012-08-08 16:40:40 C License Key File Fault Licensing=1 (No license key file installed.) 2012-08-15 09:35:59 M EulForLargeRbsConfigLicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M NodeBFunction_16QamLicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M RbsLocalCell_MaxNumEulUsersExceedsLicensedLimit RbsLocalCell=S3C1 (unavailable) 2012-08-15 09:35:59 M NodeBFunction_HsdpaFlexibleSchedulerLicenseNotValid NodeBFunction=1 (unavailable)

Go to Top

Page 15

2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsdpaUsersExceedsLicensedLimit RbsLocalCell=S2C1 (unavailable) 2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsdpaUsersExceedsLicensedLimit RbsLocalCell=S1C1 (unavailable) 2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit RbsLocalCell=S3C1 (unavailable) 2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit RbsLocalCell=S2C1 (unavailable) 2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit RbsLocalCell=S1C1 (unavailable) 2012-08-15 09:35:59 M RbsLocalCell_MaxNumEulUsersExceedsLicensedLimit RbsLocalCell=S2C1 (unavailable) 2012-08-15 09:35:59 M NodeBFunction_HsdpaDynamicCodeAllocationLicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M NodeBFunction_DlPowerControlEulLicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M RbsLocalCell_MaxNumEulUsersExceedsLicensedLimit RbsLocalCell=S1C1 (unavailable) 2012-08-15 09:35:59 M NodeBFunction_HsdpaImprovedLinkAdaptationLicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsdpaUsersExceedsLicensedLimit RbsLocalCell=S3C1 (unavailable) 2012-08-15 09:35:59 M EnhUeDrxLicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M NodeBFunction_EnhancedLayer2LicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M HsFachLicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M NodeBFunction_HsdpaIncrementalRedundancyLicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M IncrNumHsCodesLicenseNotValid NodeBFunction=1 (unavailable) 2012-08-15 09:35:59 M NodeBFunction_64QamLicenseNotValid NodeBFunction=1 (unavailable) >>> Total: 23 Alarms (1 Critical, 21 Major) About : When there is a total power outage to the node, it will roll its time stamp back to the original timestamp which is of the year 1970. The license keys,

Go to Top

Page 16

however, has a valid date of the date when it was ordered, which usually is recent. And as a result the licence keys become invalid. Symptoms will be that there are many licence keys alarms and the node will stop carrying traffic. Conditions : : Node not carrying traffic Timestamp shows date like this 01-01-1970 (most of the cases) Cold restart will not help to set the time correctly. PROCEDURE: : Activate emergency unlock keys on the licenses Set the node to the correct recent timestamp. Refer to the RNC for correct timestamp. Alarm would be gone.

: :: : :: ALARM 36: Node Status Analyzer doesn’t open If you get the following error when opening "NODE STATUS ANALYZER" to view cell activity remotely: "mismatch: struct IDL:Configuration/DataTypes/UndefinedValue:1.0 UndefinedValue{long dummy} != string[0] vmcid: 0x0 minor code: 0 completed: No Please run the Iub consistency report on the RNC. How to open NODE STATUS ANALYZER: In WCDMA RAN Explorer, Select the RBSàRight click on itàGo to "Tools"àSelect "Node Status Analyzer" How to run the Iub consistency report: In WCDMA RAN Explorer, Select the RNC that RBS belongs toàRight click on itàGo to "Consistency"àSelect "IUB Consistency Report"

# The cabx printout has PORT information at the end.# For a 3 sector site there are 6 PORT information. One line for# RU and FU devices (3 RU+3FU). # The cabx printout has PORT information at the end.# For a 3 sector site there are 6 PORT information. One line for# RU and FU devices (3 RU+3FU).# The cabx printout has PORT information at the end.# For a 3 sector site there are 6 PORT information. One line for# RU and FU devices (3 RU+3FU).

Go to Top

Page 17

ALARM 37: RfCable_Disconnected equipment_malfunction Due to the TX plugin from FU board being disconnected. Plug it back in. A restart of the plugin unit may be required to eliminate the alarm.

ALARM 38: loss_of_signal ET 1-2 connector pulled out

ALARM 39: TU Synch Reference Loss of Signal loss_of_signal TU Synch Reference Loss of Signal loss_of_signal Probable cause: TimingUnit=1,TuSyncRef=1 is unlocked but disabled. Solution: Lock the TimingUnit=1,TuSyncRef=1 so that it is locked and disabled. RBSXXXX> alt

Starting to retrieve active alarms Nr of active alarms are: 1 ============================================================================= =================== Date & Time (Local) S Specific Problem Cause Mo-Reference ============================================================================= =================== 2007-09-20 01:33:03 M TU Synch Reference Loss of Signal loss_of_signal Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,TimingUnit=1,TuSyncRef=1 >>> Total: 1 Alarms (0 Critical, 1 Major) When u see this alarm, do a lst on TimingUnit=1,TuSyncRef=1: RBSXXXX> lst TimingUnit=1,TuSyncRef=1

Go to Top

Page 18

============================================================================= ====== Proxy Adm State Op. State MO ============================================================================= ====== 136 1 (UNLOCKED) 0 (DISABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,TimingUnit=1,TuSyncRef=1 ============================================================================= ====== Total: 1 MOs If it is unlocked like in the above state, than that is the cause of the alarm, the reson of the alarm is that the RBS are getting their synchronisation signal from the E1s and not from the timing unit by gps. So if this mo is unlocked it is expecting a sync signal that it is not getting so it thinks that the source of sync just droped and it lost the signal, hence the alarm. Lock that MO and the alarm should clear. RBSXXXX> lbl 136 ============================================================================= ====== Proxy Adm State Op. State MO ============================================================================= ====== 136 0 (LOCKED) 0 (DISABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,TimingUnit=1,TuSyncRef=1 ============================================================================= ====== Total: 1 MOs There should be no alarms left: RBSXXXX> alt Starting to retrieve active alarms Nr of active alarms are: 0 ============================================================================= =================== Date & Time (Local) S Specific Problem Cause Mo-Reference

Go to Top

Page 19

============================================================================= =================== >>> Total: 0 Alarms (0 Critical, 0 Major) TO finish, It is very important to create a cv and set it as startable. ALARM 40: AuxPlugInUnit_NewAuxiliaryUnitDetectedNotCorrespondingToTheDefinedConfigurati on While doing DUW integration for 6K series nodes we faces issues about sectors not coming up in the node. When you face such kind of alarm just ask your FE to follow the below steps :: 1. Ask FE to export & delete scripts while running the Cesar ftp on his computer. 2. After that restart the DUW & RRUWs. Note :: When you export and delete that does not delete the CVs that were previously created, it will re-create basic CVs again. Alarms should be gone now.