ZTE SDR Alarms On ZONG Project

ZTE SDR Alarms on ZONG Project SDR Alarms Types Phase I Indoor site (GSU)  Phase l Outdoor site  Phase I Outdoor Sol

Views 95 Downloads 0 File size 502KB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

Citation preview

ZTE SDR Alarms on ZONG Project

SDR Alarms Types Phase I Indoor site (GSU)  Phase l Outdoor site  Phase I Outdoor Solar site (GSU)  Phase 0 Indoor site (GSUR)  Phase II site (MISU) 

Phase I Indoor

Phase I Indoor site Alarms detail

Precautions during SDR swap Conform sensors to BTS connections  Than conform with OMCR how many alarms are working on BTS  After that cut alarm cable from BTS end  BTS alarm cable connect with SDR alarm cable following color scheme  Than alarm test on SDR 

SDR to BTS color scheme

Phase I Outdoor site

Phase I Outdoor site Alarms detail

Precautions during SDR swap     

Conform sensors to BTS connections Than conform with OMCR how many alarms are working on BTS BTS alarm cable and SDR alarm cable color scheme is same Sensors alarm cable direct connect with SDR alarm cable same like BTS alarm cable Than alarm test on SDR

Outdoor Solar site

Phase I Outdoor Solar site Solar site alarm template is change to other sites  Solar site have seven alarm  All sensors are connect with GSU  GSU out put connect with BTS or SDR  Outdoor BTS and SDR alarm cable color combination are same 

Outdoor SDR solar site Alarm detail and connection

Precautions during SDR swap Conform GSU output to BTS connections  Than conform with OMCR how many alarms are working on BTS  BTS alarm cable and SDR alarm cable color scheme is same  GSU output cables connect with SDR alarm cable same like BTS alarm cable  Than alarm test on SDR 

Phase 0 Indoor sites

Phase 0 Indoor site Phase 0 site alarm template is same like Phase I sites  BTS alarm cable color combination not same with Phase I cable  All sensors are connect with GSUR  GSUR out put connect with BTS or SDR 

Phase 0 Indoor site Alarms detail

Precautions during SDR swap     

Conform sensors to BTS connections Than conform with OMCR how many alarms are working on BTS After that cut alarm cable from BTS end BTS alarm cable connect with SDR alarm cable following color scheme Than alarm test on SDR

SDR to BTS color scheme

Phase II (MISU)

Precautions during SDR swap First conform with OMCR how many alarms are working MISU  Conform MISU E1 connect with BTS PCM number  After swap conform SDR PCM number and connect with MISU  Than alarm test on SDR 

MISU E1 connection with SDR SDR E1 cable Color Orange Double Dot red

MISU E1Converter cable color White -Green

Orange Double Dot Black

Blue

Gray Double Dot red

White-Orange

Gray Double Dot Black

Orange