No. Model Version System For SUPOR with 1 TQ-A001 T2.0 SUPOR-A-PA32128 Module For SUPOR with 2 TQ-A002 T1.0 S
Views 145 Downloads 1 File size 334KB
No.
Model
Version
System
For SUPOR with 1
TQ-A001
T2.0
SUPOR-A-PA32128 Module
For SUPOR with 2
TQ-A002
T1.0
SUPOR-A-PA32128 Module
Probe
SIUI Probe
ITT Connector
Picture
Description
a) Y splitter for two phased array probes. b) Max. supporting elements: 64.
a) Y splitter for two phased array probes. b) After adapting, max. supporting elements: 64.
1
No.
3
Model
TQ-A003
Version
T1.0
System
For Omniscan
SIUI
MX/MX2
Probe
For SUPOR with 4
TQ-A004
T1.0
Probe
SUPOR-A-PA32128 module
Olympus Probe
Picture
Description a) Y splitter for two phased array probes. b) After adapting, max. supporting elements: 64. c) Suitable for Omniscan MX/MX2 with 32:128 module. d) The adapter is connected to the probe connector with a 75cm probe cable.
a) Y splitter for two phased array probes. b) After adapting, max. supporting elements: 64.
2
No.
Model
Version
System
D-Type Male)
C1(78 Way D-Type Female)
connector
connector
For TD HandyScan 5
6
TQ-A005
TQ-A006
T1.0
T1.0
Probe
With C1(78 Way
For SyncScan series PA module
SIUI Probe
Picture
Description
a) Y splitter for two phased array probes. b) After adapting, max. supporting elements: 32. c) The adapter is connected to the probe connector with a 100cm probe cable.
a) Y splitter for two phased array probes. b) After adapting, max. supporting elements: 64.
3
No.
7
8
Model
TQ-A007
TQ-A008
Version
T1.0
T1.0
System
Probe
Picture
Description
For SUPOR with SUPOR-A-PA32128 SIUI or SUPOR-A-PA1664 Probe module
a) Y splitter for two phased array probes. b) Max. supporting elements: 32.
TD HandyScan, C1(78 Way D-Type male) connector
a) Adapter for one phased array probe. b) After adapting, max. supporting elements: 64. c) Two sides are connected by 75cm probe cable.
SIUI Probe
4
No.
9
10
Model
TQ-A009
TQ-A010
Version
T1.0
T1.0
System
Probe
For SUPOR with SUPOR-A-PA32128 Olympus or Probe SUPOR-A-PA1664 module
Omni connector, with Olympus Omniscan MX2
C1 connector, with TD phased array probe
Picture
Description
a) Y splitter for two phased array probes. d) After adapting, max. supporting elements: 32.
a) Adapter for one phased array probe, max. supporting elements: 64. b) Two sides are connected by 75cm probe cable.
5
No.
11
12
Model
TQ-A011
TQ-A012
Version
T1.0
T1.0
System
With Sonatest VEO (With the same connector as Olympus)
GE equipment (Tyco connector)
Probe
Picture
Description
Olympus Probe
a) Y splitter for two phased array probes. b) Suitable for VEO 16:64 module. c) After adapting, max. supporting elements: 32. d) Two sides are connected by 100cm probe cable.
SIUI Probe
a) Y splitter for two phased array probes. b) After adapting, max. supporting elements: 32. c) The adapter is connected to the probe connector with a 75cm probe cable.
6
No.
13
14
Model
TQ-A013
TQ-A014
Version
T1.0
T1.0
System
GE equipment (Tyco connector)
TD handyscan equipment, max. supporting elements: 64.
Probe
Picture
Description
SIUI Probe
a) Y splitter for two phased array probes. b) After adapting, max. supporting elements: 64 c) The adapter is connected to the probe connector with a 75cm probe cable.
Olympus probe (Omni connector)
a) Y splitter for two phased array probes. b) After adapting, max. supporting elements: 32 c) Two sides are connected by 75cm probe cable.
7
No.
15
16
Model
TQ-A015
RT1-Z-P1
Version
System
T1.0
For Olympus system
T1.0
For Olympus Omniscan MX/MX2 system
Probe
RP1-Z-T1
T2.0
Olympus probe (Omni connector)
SIUI Probe
b) Adapter for one phased array probe. c) Max. supporting elements: 128.
with PA module or
Olympus
SyncScan series
Probe
with PA module.
Description
a) Y splitter for two phased array probes. b) After adapting, max. supporting elements: 64 c) Two sides are connected by 75cm probe cable.
For SUPOR series 17
Picture
a) Adapter for one phased array probe. b) Max. supporting elements: 128, subject to the system. 8
No.
Model
Version
System
Probe
Picture
Description a) Adapter for one phased array probe. b) Max. supporting
For Zetec system 18
RT1-Z-0.75-H1 T1.0
with Hypertronics connector,
SIUI Probe
elements: 128 c) The adapter is connected to the probe matching box with a 75cm probe cable.
a) Adapter for one phased array probe. b) Max. supporting 19
RH1-Z-0.75-T1 T1.0
For SUPOR series with PA module
Zetec DYNARAY Probe
elements: 128 c) The adapter is connected to the probe matching box with a 75cm probe cable.
9
No.
Model
Version
System
Probe
Picture
Description
a) Adapter for one phased array probe. b) Max. supporting For Zetec System 20
RP1-Z-0.75-H1 T1.0
with Hypertronics connector
Olympus Probe
elements: 128. c) The adapter is connected to the probe matching box with a 75cm probe cable.
a) Adapter for one phased array probe. b) Max. supporting 21
RH1-Z-0.75-P1 T1.0
For Omniscan MX/MX2
Zetec DYNARAY Probe
elements: 128. c) The adapter is connected to the probe matching box with a 75cm probe cable.
10