Accredited for compliance with ISO/ IEC 17025 Facility No. 19159 Komp. Bintang Industrial Park 1, Lot No. 27 – 28, Batu
Views 124 Downloads 1 File size 213KB
Accredited for compliance with ISO/ IEC 17025 Facility No. 19159
Komp. Bintang Industrial Park 1, Lot No. 27 – 28, Batu Ampar, Batam, Indonesia – 29457 Ph : +62 778 413 007 Fax : +62 778 413 017
MAGNETIC PARTICLE INSPECTION REPORT CONTRACTOR
:
PT. REKAYASA INDUSTRI
REPORT NO.
:
PTLA/MT/020
PROJECT
:
PROVISION OF 16” OFFSHORE SECTIONAL PIPE LINE RELOCATION AND INSTALATION
CONTRACT/ JOB NO
:
-
LOCATION
:
WORKSHOP PT. LOUIS ALAIN
TEST DATE
:
17 July 2014
SPECIFICATION:
ACCEPTANCE CRITERIA:
PROCEDURE NO:
API 1104 Rev. 2010
API 1104 Rev. 2010 SECT. 9.4
NDT-OPR-004 / 2:0 NDT-TEC-M002 REV . 1
SPECIMENT DATA MATERIAL
: API 5L X52
DRAWING NO.
: N/A
TESTING TEMPERATURE
: AMBIENT
WELDING PROCESS
: N/A
SURFACE CONDITION
: AS SMOOTH
WELD PREPARATION
: N/A
MATERIAL DIMENTION
: Ø 16 “ X THK = 12.7 mm
REQUEST FOR INSPECTION (RFI) NO.: PTLA/REKAYASA/MT-0022014
MPI DATA: EQUIPMENT USED
: AC YOKE
CONTRAST PAINT
SERIAL NUMBER
: 8820
CALIBRATION
: 10 LBS
CURRENT
: 220 – 240 V
ILLUMINATION
: DAY LIGHT
SENSITIVITY
: BURMAH CASTROL
BATCH NO.
: MAGNAFLUX – WCP 2 : 13H16K
MAGNETIC (POWDER / INK) : MAGNAFLUX – 7HF BATCH NO. INSPECTION METHODS
: 13H11K :
DRY
WET
CONTINUOS
RESIDUAL
RESULT:
Note:
IDENTIFICATION
JOINT NUMBER
WELDER
DIMENTION
MPI TEST COUPON 1
1.0 ML/WPS/REK/X52/2014
-
Ø 16 “ X THK = 12.7 mm
MPI TEST COUPON 2
1.0 ML/WPS/REK/X52/2014
-
Ø 16 “ X THK = 12.7 mm
MPI TEST COUPON 3
1.0 ML/WPS/REK/X52/2014
-
Ø 16 “ X THK = 12.7 mm
MPI TEST COUPON 4
1.0 ML/WPS/REK/X52/2014
-
Ø 16 “ X THK = 12.7 mm
MPI TEST COUPON 5
1.0 ML/WPS/REK/X52/2014
-
Ø 16 “ X THK = 12.7 mm
MPI TEST COUPON 6
1.0 ML/WPS/REK/X52/2014
-
Ø 16 “ X THK = 12.7 mm
MPI TEST COUPON 7
1.0 ML/WPS/REK/X52/2014
-
Ø 16 “ X THK = 12.7 mm
MPI TEST COUPON 8
1.0 ML/WPS/REK/X52/2014
-
Ø 16 “ X THK = 12.7 mm
C = Comply
C
RESULT DNC
DNC = Does Not Comply
REMARKS/ TEST RESTRICTIONS: MPI WAS CARIED OUT 100 % ON BEVEL SURFACE AREA NO RELEVANT INDICATION WAS FOUND DURING TIME OF INSPECTION
TECHNICIANS
VERIFIED BY: (SITE SUPERVISOR)
Name : ANDREW JORDAN Qualification: MT PCN II Date : 17 July 2014
Name : ANDREW JORDAN Qualification: MT PCN II Date : 17 July 2014
CONTRACTOR'S REP:
Name : Date :
Page 1 of 1
COMPANY OWNER REP:
Name : Date :
3rd PARTY (where applicable)
Name : Date :
NDT-FRM-006 Issued 3 Rev. 0
Accredited for compliance with ISO/ IEC 17025 Facility No. 19159 "This report signifies acceptancePark or otherwise the acceptance criteria of the applicable standard. Such compliance, or otherwise, does not infer or imply suitability and/or Komp. Bintang Industrial 1, Lotwith No.regard 27 – only 28, toBatu fitness for any particular use or purpose. No other communication by Oceaneering, whether oral or written, shall be construed as an opinion as to whether the weld or other work inspected Ampar, Batam, Indonesia – 29457 should be accepted or rejected." Ph : +62 778 413 007 Fax : +62 778 413 017
Page 2 of 1
NDT-FRM-006 Issued 3 Rev. 0
Accredited for compliance with ISO/ IEC 17025 Facility No. 19159
Komp. Bintang Industrial Park 1, Lot No. 27 – 28, Batu Ampar, Batam, Indonesia – 29457 Ph : +62 778 413 007 Fax : +62 778 413 017
MAGNETIC PARTICLE INSPECTION REPORT CONTRACTOR
:
REPORT NO.
:
PROJECT
:
CONTRACT/ JOB NO
:
TEST DATE
:
LOCATION : SKETCH/ PHOTOGRAPH:
TECHNICIANS
Name : Qualification: Date :
VERIFIED BY: (SITE SUPERVISOR)
Name : Qualification: Date :
CONTRACTOR'S REP:
Name : Date :
Page 3 of 1
COMPANY OWNER REP:
Name : Date :
3rd PARTY (where applicable)
Name : Date :
NDT-FRM-006 Issued 3 Rev. 0