TABLA 3: PLANILLA DE CALCULO RED DE AGUA POTABLE (QMáx hora Cañería PVC Tramo 1 2 3 4 5 6 7 8 9 10 2 3 4 5 6 7 8 9 10
Views 84 Downloads 0 File size 77KB
TABLA 3: PLANILLA DE CALCULO RED DE AGUA POTABLE (QMáx hora Cañería
PVC
Tramo 1 2 3 4 5 6 7 8 9 10
2 3 4 5 6 7 8 9 10 11
Longitud
Diámetro
Espesor
Diámetro
Caudal
Velocidad
L (m) 120.0 130.0 56.0 88.0 50.0 50.0
Nominal (m) 0.160 0.110 0.110 0.110 0.110 0.110 0.075 0.075 0.075 0.075
e
Interno (m) 0.1446 0.0946 0.0994 0.0994 0.1028 0.1028 0.0678 0.0678 0.0678 0.0678
Q (L/s) 17.5 12.0 10.3 8.0 6.0 4.0 4.0 4.0 4.0 4.0
V (m/s) 1.066 1.707 1.327 1.031 0.723 0.482 1.108 1.108 1.108 1.108
(mm) 0.0077 0.0053 0.0053 0.0053 0.0053 0.0053 0.0030 0.0030 0.0030 0.0030
Presion Inicial L=120 m D=160mm 1
17,5 L/s
L=56 m D=110mm
L=130 m D=160mm 2
NO BORRAR Tuberia PVC Clase 10 Diametro mm. Espesor mm Diametro mts 20 1.5 0.020 25 1.5 0.025 32 1.8 0.032 40 2.0 0.040 50 2.4 0.050 63 3.0 0.063 75 3.0 0.075 90 4.3 0.090 110 5.3 0.110 125 6.0 0.125 140 6.7 0.140 160 7.7 0.160 200 9.6 0.200 250 12.0 0.250
12 L/s
Espesor mts 0.0015 0.0015 0.0018 0.0020 0.0024 0.0030 0.0030 0.0043 0.0053 0.0060 0.0067 0.0077 0.0096 0.0120
3
10,3 L/s
315 355 100
15.2 17.1 19.2
0.315 0.355 0.100
0.0152 0.0171 0.0192
LE (QMáx hora) coef. Resistencia local
V /2g (m) 0.058 0.149 0.090 0.054 0.027 0.012 0.063 0.063 0.063 0.063 2
L=56 m D=110mm 10,3 L/s
Coef.
Coef.
Pérdida
Cota
Presión
Cota
Presión
Re
f
Ki
137,582 144,206 117,799 91,495 66,351 44,234 67,069 67,069 67,069 67,069
0.0167 0.0166 0.0173 0.0182 0.0195 0.0213 0.0194 0.0194 0.0194 0.0194
1 2 2 2 2 2 2 2 2 2
Energía (m) 0.86 3.68 1.05 0.98 0.31 0.15 0.13 0.13 0.13 0.13
Inicial (m) 100.0 98.0 92.0 90.0 88.0 93.0 94.0 94.0 94.0 94.0
Inicial (m) 16.51 17.65 19.97 20.92 21.94 16.63 15.48 15.36 15.23 15.11
Final (m) 98.0 92.0 90.0 88.0 93.0 94.0 94.0 94.0 94.0 94.0
Final (m) 17.6 20.0 20.9 21.9 16.6 15.5 15.4 15.2 15.1 15.0
L=88 m D=110mm 4
8 L/s
L=50 m D=75mm 5
6 L/s
L=50 m D=75mm 6
4 L/s
7
PRESION MINIMA DE LOS TRAMOS Recalcular ya que es Menor a 15 14.98