Paradise Datacom Mini-Redundant SSPA 209495 RevA

Redundant Systems Mini Compact Outdoor SSPA C-Band 1:1 Redundant Mini Compact Outdoor Plate Assembly DESCRIPTION Teled

Views 27 Downloads 2 File size 336KB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

Citation preview

Redundant Systems Mini Compact Outdoor SSPA

C-Band 1:1 Redundant Mini Compact Outdoor Plate Assembly

DESCRIPTION Teledyne Paradise Datacom’s Outdoor series of redundant Mini Compact Outdoor amplifier systems provide the highest degree of earth station redundancy and reliability. Based on Teledyne Paradise Datacom’s family of rugged and robust SSPAs, these systems provide the highest MTBFs possible. These systems can be configured in either 1:1 or 1:2 redundant configurations using the Teledyne Paradise Datacom family of redundant controllers. The RCP2-1100 and RCP2-1200 Redundant Controllers provide an extremely user-friendly interface for complete monitor and control of the high power amplifiers in either 1:1 or 1:2 configurations. The RCP front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights provide easy indication of system status. All RCP monitor and control is available locally at the front panel LCD display, and also remotely by the RS-232, RS-485 or Ethernet interface ports. Teledyne Paradise Datacom LLC 328 Innovation Blvd., Suite 100 State College, PA 16803 USA Tel: (814) 238-3450 Fax: (814) 238-3829 1 OF 8

www.paradisedata.com

FEATURES • System Output Power to: 200 W C-Band; 200 W X-Band; 80 W Ku-Band • Universal Input, Power Factor Corrected Power Supply • Output Power Monitoring • Separate 1RU Redundant Controller or Controllerless configurations OPTIONS • System Output Power Monitor • L-Band Input operation • Input switching or Input splitting • Cold Standby Amplifier Operation

Teledyne Paradise Datacom Ltd. 2&3 The Matchyns, London Road, Rivenhall End Witham, Essex CM8 3HA United Kingdom Tel: +44(0) 1376 515636 Fax: +44(0) 1376 533764 209495 REV A ECO 16884

Redundant Systems Mini Compact Outdoor SSPA

Mini Compact Outdoor Output Power Levels C-Band: 75 W - 200 W X-Band: 50 W - 200 W Ku-Band: 50 W - 80 W

Typical C-Band System Output Power 1:1 Redundant Output Power

Single Thread Amplifier Model

PSAT dBm (W)

HPACC3075AC

48.6 (72)

HPACC3100AC Single Thread Amplifier Model HPACC3200AC

P1dB dBm (W)

PSAT dBm (W)

P1dB dBm (W)

48.3 (68)

HPAXX3050AC

46.8 (48)

46.3 (43)

HPAXX3075AC

48.6 (72)

48.1 (65)

HPAXX3100AC

49.8 (95)

49.3 (85)

Single Thread Amplifier Model

1:1 Redundant Output Power PSAT dBm (W)

PLINEAR dBm (W)

HPAXX3200AC

52.8 (190)

49.8 (95)

49.8 (95)

Typical Ku-Band System Output Power 1:1 Redundant Output Power

Single Thread Amplifier Model

PSAT dBm (W)

P1dB dBm (W)

HPAKU3050AC

46.8 (48)

45.8 (38)

Single Thread Amplifier Model HPAKU3080AC

2 OF 8

1:1 Redundant Output Power

Single Thread Amplifier Model

49.8 (95) 49.3 (85) 1:1 Redundant Output Power PSAT dBm (W) PLINEAR dBm (W) 52.8 (190)

Typical X-Band System Output Power

1:1 Redundant Output Power PSAT dBm (W) PLINEAR dBm (W) 48.8 (76)

45.8 (38)

209495 REV A ECO 16884

Redundant Systems Mini Compact Outdoor SSPA General Specifications PARAMETER Gain Gain Flatness Gain Slope Gain Variation vs. Temperature Gain Adjustment Intermodulation Distortion AM/PM Conversion

Spurious (SSPA only) Harmonics (SSPA only)

NOTES

LIMITS

UNITS

minimum full band (C-/X-/Ku-Bands) full band (Extended C-Band, Extended Ku-Band) per 40 MHz -40°C to +60°C 0.1 dB resolution

67 ±1.0 ±1.5 +0.3 ±1.5 20

dB dB dB dB/40 MHz dB dB

Two-tone 3dB back off relative to P1dB @ rated PLINEAR1

-25 -25

dBc dBc

(@ rated P1dB) (@P1dB-1dB) (@P1dB-2dB) (@ rated PLINEAR)1

3.5 1.5 1.0 2.0

°/dB °/dB °/dB °/dB

(@ rated P1dB), (@ rated PLINEAR)1 (@ rated P1dB-3dB), (@ rated PLINEAR)1

-60 -50

dBc dBc

Input/Output VSWR Noise Figure

1.50:1 at maximum gain

10

dB

Group Delay (per 40 MHz segment)

Linear Parabolic Ripple

0.01 0.003 1.0

ns/MHz ns/MHz2 ns p-p

Transmit Band Noise Output Power Density

TX Band RX Band

-75 -150

dBW/4 KHz dBW/4 KHz

0 - 10 KHz 10 KHz - 500 KHz 500 KHz - 1 MHz

-45 -20 (1.25 + log F) -80

dBc dBc dBc

Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz

-90 -100 -110 -120 -125 -130

dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz

Psat to (Psat - 20 dBm)

20 ± 1.0

dBm

°C

Residual AM Noise

Phase Noise

RF Power Detector

Environmental Operating Temperature

Ambient

-40 to +60

condensing

100

%

Integrated, Forced Air

265

CFM

Relative Humidity Cooling System 1

200W C-Band, 200W X-Band and 80W Ku-Bands only.

Mechanical Size, Mini Compact Outdoor Weight, Mini Compact Outdoor

width X length X height

9.0 X 12.0 X 6.50 229 X 305 X 165

inches mm

Base unit

24.5 (11.2) ± 3%

lbs.(kg)

Paint

White; powder coat

RF Input RF Output - Ku-Band RF Output - C-Band RF Output - X-Band RF Output Sample Line Power Monitor and Control Link Port Redundancy Switch Auxiliary +15VDC LNB Power (500 mA)

Type N WR75 Waveguide WR137 Waveguide WR112 Waveguide Type N 3-pin MS type 32-pin MS type 6-pin MS type 6-pin MS type 6-pin MS type

Female Grooved Flange Grooved Flange Grooved Flange Female Plug Socket Socket Socket Socket

Finish Connectors

Specifications are subject to change. 3 OF 8

209495 REV A ECO 16884

Redundant Systems Mini Compact Outdoor SSPA L-Band Operation Paradise Datacom offers C-, X-, and Ku-Band amplifiers with an integrated L-Band Block Up Converter. • BUC includes Smart Reference Technology which enables the BUC to detect and switch to an extenally supplied reference. • Optional internal high stability reference. • Can lock to an externally supplied reference of 10 or 50 MHz without modification. • Can accept a wide range of external reference power (-10dBm to +5 dBm) • Can accept FSK monitor and control signal via the IFL. Available Frequency Plans Band

Frequency Band

IF Input

LO Frequency

RF Output

Gain Change

C

Standard C-Band

950 - 1525 MHz

4.900 GHz

5.850 - 6.425 GHz

0-4 dB

C

Extended C-Band

950 - 1825 MHz

4.900 GHz

5.850 - 6.725 GHz

0-4 dB

X

Standard X-Band

950 - 1450 MHz

6.950 GHz

7.900 - 8.400 GHz

0-2 dB

Ku

Standard Ku-Band

950 - 1450 MHz

13.050 GHz

14.00 - 14.50 GHz

0-2 dB

Ku

Extended Ku-Band

950 - 1700 MHz

12.800 GHz

13.75 - 14.50 GHz

0-2 dB

Ku

Sub Ku-Band 1

1200 - 1450 MHz

11.800 GHz

13.00 - 13.25 GHz

0-2 dB

Ku

Sub Ku-Band 2

950 - 1450 MHz

11.800 GHz

12.75 - 13.25 GHz

0-2 dB

Electrical Specifications for Mini Compact Outdoor SSPA with BUC PARAMETER Gain Gain Flatness Gain Slope Gain Adjusted Range Gain Stability Phase Noise

Spurious

Noise Figure Input VSWR Internal Reference Option

4 OF 8

NOTES

LIMITS

UNITS

Nominal setting full band (C-,X-,Ku-bands) full band (Extended C-/Ku) per 40 MHz (C-,X-,Ku-bands)

75 ± 2.0 ± 2.5 ± 0.5 20 55 - 75 ± 1.5

dB dB dB dB/40 MHz dB dB dB

Typical Adj. Range -40 to +60 °C Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz

Absolute max. -30 -60 -70 -80 -90 -90

C-band (typ.) -60 -80 -80 -85 -120 -125

X-band (typ.) -60 -75 -75 -100 -110 -122

Ku-band (typ.) -50 -65 -72 -90 -110 -120

dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz

In-Band Signal Related (C-/X-/Ku-Band) (Extended C-Band) Close to Carrier Spurious (< 20 MHz) Local Oscillator Non-Signal Related

-50 -40 -50 -30 -40

dBc dBc dBc dBm dBm

At 75 dB gain setting

20

dB

L-Band

1.5 : 1

Reference accuracy @ 25 °C Reference Stability over Temperature (-20 to +85 °C)

± 3 • 10-7 ± 1.5 • 10-8

209495 REV A ECO 16884

Redundant Systems Mini Compact Outdoor SSPA Amp 1

RF OUT-POL 1

RF IN-POL 1 Amp 2

RF IN-POL 2

1:1 Redundant HPA System, Input Switching

Amp 3

RF OUT-POL 2

1:2 Redundant HPA System, Input Switching

Teledyne Paradise Datacom’s Mini Compact Outdoor Redundant Systems are designed with built-in redundancy for 1:1 systems, so all system-level monitor and control is internal and no separate controller is required, although an optional RCP2-1100 1:1 Redundant Controller is available. Either Ethernet or RS-485 communications are selectable for user monitor and control. All 1:2 redundant systems require a separate RCP2-1200 Redundant Controller.

RCP2-1100 1:1 Redundant Controller

RCP2-1200 1:2 Redundant Controller

The RCP2-1X00 is the heart of the Redundant System. It provides an extremely user friendly interface for complete monitor and control of the high power amplifiers. The front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights are provided for easy indication of system status. All RCP2-1X00 monitor and control is available locally, at the front panel LCD display, as well as remotely by the RS-232 or RS-485 interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel of the RCP2-1X00.

5 OF 8

209495 REV A ECO 16884

Redundant Systems Mini Compact Outdoor SSPA 23.50 [596.9] 22.50 [571.5] (2x)

9.00 [228.6]

11.75 [298.45] (4x)

9.00 [228.6] Ø.39 [Ø9.8]

1.00 [25.4] (2x)

.00 [0]

1.00 [25.4] (3x)

5.57 [141.5]

8.40 [213.36] (2x)

11.75 [298.45]

20.40 [518.16] (2x)

22.50 [571.5] (3x)

23.50 [596.9]

.00 [0]

12.32 [312.92] 11.20 [284.4]

.25 [6.35] .00 [0]

Outline Drawing, Typical Ku-Band Mini Compact Outdoor SSPA 1:1 Redundant System

6 OF 8

209495 REV A ECO 16884

Redundant Systems Mini Compact Outdoor SSPA 23.50 [596.90] 22.50 [571.50] (2x)

9.00 [228.60]

11.75 [298.45]

Ø.39 [Ø9.80]

9.00 [228.60]

.00 [.00] .00 [.00]

1.00 [25.40] (3x)

5.00 [127.00]

8.40 [213.36] (2x)

11.75 [298.45]

20.40 [518.16] (2x)

22.50 [571.50] (3x)

23.50 [596.90]

1.00 [25.40] (2x)

12.57 [319.39] 11.20 [284.40]

.25 [6.35] .00 [.00]

Outline Drawing, Typical C-Band Mini Compact Outdoor SSPA 1:1 Redundant System

7 OF 8

209495 REV A ECO 16884

Redundant Systems Mini Compact Outdoor SSPA Part Number Configuration, Mini Compact Outdoor Systems HPA

3

C

Band CC - C-Band XX - X-Band KU - Ku-Band

Configuration Modifier XXX XMX XTX1 XUX1

Power Level (in Watts) C-Band 075, 100 or 200 X-Band 050, 075, 100 or 200 Ku-Band 050 or 080

Frequency Sub Band C-Band A1 - 5.85 - 6.425 GHz B1 - 5.85 - 6.725 GHz X-Band A1 - 7.90 to 8.40 GHz Ku-Band A1 - 14.00 - 14.50 GHz B1 - 13.75 - 14.50 GHz E1,2 - 13.00 - 13.25 GHz F1,2 - 12.75 - 13.25 GHz

1

= = = =

Standard MS-Connector Covers Transmit Band Filter MS-Connector Covers & Transmit Band Filter

X-Band only.

System Configuration

A1 = 1:1 w/ Input Switching, Internal control B = 1:1 w/ Input Splitter, Internal control C1 = 1:2 w/ Input Switching & RCP2-12002 D1 = 1:2 w/ Input Switching, Internal control F = 1:1 w/ Input Splitter & RCP2-11002 H1 = 1:1 w/ Input Switching & RCP2-11002 S = System (Custom) 1 2

Not available with BUC option P. Standard Cable Length of 100 ft. (30m) with RCP unit.

Block Up Converter A = None (RF Input) M = Internal Reference BUC P = External Reference BUC

Package C = Mini Compact Outdoor

1 2

Available with optional BUC. Not available in 80W Ku-Band units.

Specifications in this document are subject to change without notice. 8 OF 8

209495 REV A ECO 16884