Redundant Systems Mini Compact Outdoor SSPA C-Band 1:1 Redundant Mini Compact Outdoor Plate Assembly DESCRIPTION Teled
Views 27 Downloads 2 File size 336KB
Redundant Systems Mini Compact Outdoor SSPA
C-Band 1:1 Redundant Mini Compact Outdoor Plate Assembly
DESCRIPTION Teledyne Paradise Datacom’s Outdoor series of redundant Mini Compact Outdoor amplifier systems provide the highest degree of earth station redundancy and reliability. Based on Teledyne Paradise Datacom’s family of rugged and robust SSPAs, these systems provide the highest MTBFs possible. These systems can be configured in either 1:1 or 1:2 redundant configurations using the Teledyne Paradise Datacom family of redundant controllers. The RCP2-1100 and RCP2-1200 Redundant Controllers provide an extremely user-friendly interface for complete monitor and control of the high power amplifiers in either 1:1 or 1:2 configurations. The RCP front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights provide easy indication of system status. All RCP monitor and control is available locally at the front panel LCD display, and also remotely by the RS-232, RS-485 or Ethernet interface ports. Teledyne Paradise Datacom LLC 328 Innovation Blvd., Suite 100 State College, PA 16803 USA Tel: (814) 238-3450 Fax: (814) 238-3829 1 OF 8
www.paradisedata.com
FEATURES • System Output Power to: 200 W C-Band; 200 W X-Band; 80 W Ku-Band • Universal Input, Power Factor Corrected Power Supply • Output Power Monitoring • Separate 1RU Redundant Controller or Controllerless configurations OPTIONS • System Output Power Monitor • L-Band Input operation • Input switching or Input splitting • Cold Standby Amplifier Operation
Teledyne Paradise Datacom Ltd. 2&3 The Matchyns, London Road, Rivenhall End Witham, Essex CM8 3HA United Kingdom Tel: +44(0) 1376 515636 Fax: +44(0) 1376 533764 209495 REV A ECO 16884
Redundant Systems Mini Compact Outdoor SSPA
Mini Compact Outdoor Output Power Levels C-Band: 75 W - 200 W X-Band: 50 W - 200 W Ku-Band: 50 W - 80 W
Typical C-Band System Output Power 1:1 Redundant Output Power
Single Thread Amplifier Model
PSAT dBm (W)
HPACC3075AC
48.6 (72)
HPACC3100AC Single Thread Amplifier Model HPACC3200AC
P1dB dBm (W)
PSAT dBm (W)
P1dB dBm (W)
48.3 (68)
HPAXX3050AC
46.8 (48)
46.3 (43)
HPAXX3075AC
48.6 (72)
48.1 (65)
HPAXX3100AC
49.8 (95)
49.3 (85)
Single Thread Amplifier Model
1:1 Redundant Output Power PSAT dBm (W)
PLINEAR dBm (W)
HPAXX3200AC
52.8 (190)
49.8 (95)
49.8 (95)
Typical Ku-Band System Output Power 1:1 Redundant Output Power
Single Thread Amplifier Model
PSAT dBm (W)
P1dB dBm (W)
HPAKU3050AC
46.8 (48)
45.8 (38)
Single Thread Amplifier Model HPAKU3080AC
2 OF 8
1:1 Redundant Output Power
Single Thread Amplifier Model
49.8 (95) 49.3 (85) 1:1 Redundant Output Power PSAT dBm (W) PLINEAR dBm (W) 52.8 (190)
Typical X-Band System Output Power
1:1 Redundant Output Power PSAT dBm (W) PLINEAR dBm (W) 48.8 (76)
45.8 (38)
209495 REV A ECO 16884
Redundant Systems Mini Compact Outdoor SSPA General Specifications PARAMETER Gain Gain Flatness Gain Slope Gain Variation vs. Temperature Gain Adjustment Intermodulation Distortion AM/PM Conversion
Spurious (SSPA only) Harmonics (SSPA only)
NOTES
LIMITS
UNITS
minimum full band (C-/X-/Ku-Bands) full band (Extended C-Band, Extended Ku-Band) per 40 MHz -40°C to +60°C 0.1 dB resolution
67 ±1.0 ±1.5 +0.3 ±1.5 20
dB dB dB dB/40 MHz dB dB
Two-tone 3dB back off relative to P1dB @ rated PLINEAR1
-25 -25
dBc dBc
(@ rated P1dB) (@P1dB-1dB) (@P1dB-2dB) (@ rated PLINEAR)1
3.5 1.5 1.0 2.0
°/dB °/dB °/dB °/dB
(@ rated P1dB), (@ rated PLINEAR)1 (@ rated P1dB-3dB), (@ rated PLINEAR)1
-60 -50
dBc dBc
Input/Output VSWR Noise Figure
1.50:1 at maximum gain
10
dB
Group Delay (per 40 MHz segment)
Linear Parabolic Ripple
0.01 0.003 1.0
ns/MHz ns/MHz2 ns p-p
Transmit Band Noise Output Power Density
TX Band RX Band
-75 -150
dBW/4 KHz dBW/4 KHz
0 - 10 KHz 10 KHz - 500 KHz 500 KHz - 1 MHz
-45 -20 (1.25 + log F) -80
dBc dBc dBc
Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz
-90 -100 -110 -120 -125 -130
dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz
Psat to (Psat - 20 dBm)
20 ± 1.0
dBm
°C
Residual AM Noise
Phase Noise
RF Power Detector
Environmental Operating Temperature
Ambient
-40 to +60
condensing
100
%
Integrated, Forced Air
265
CFM
Relative Humidity Cooling System 1
200W C-Band, 200W X-Band and 80W Ku-Bands only.
Mechanical Size, Mini Compact Outdoor Weight, Mini Compact Outdoor
width X length X height
9.0 X 12.0 X 6.50 229 X 305 X 165
inches mm
Base unit
24.5 (11.2) ± 3%
lbs.(kg)
Paint
White; powder coat
RF Input RF Output - Ku-Band RF Output - C-Band RF Output - X-Band RF Output Sample Line Power Monitor and Control Link Port Redundancy Switch Auxiliary +15VDC LNB Power (500 mA)
Type N WR75 Waveguide WR137 Waveguide WR112 Waveguide Type N 3-pin MS type 32-pin MS type 6-pin MS type 6-pin MS type 6-pin MS type
Female Grooved Flange Grooved Flange Grooved Flange Female Plug Socket Socket Socket Socket
Finish Connectors
Specifications are subject to change. 3 OF 8
209495 REV A ECO 16884
Redundant Systems Mini Compact Outdoor SSPA L-Band Operation Paradise Datacom offers C-, X-, and Ku-Band amplifiers with an integrated L-Band Block Up Converter. • BUC includes Smart Reference Technology which enables the BUC to detect and switch to an extenally supplied reference. • Optional internal high stability reference. • Can lock to an externally supplied reference of 10 or 50 MHz without modification. • Can accept a wide range of external reference power (-10dBm to +5 dBm) • Can accept FSK monitor and control signal via the IFL. Available Frequency Plans Band
Frequency Band
IF Input
LO Frequency
RF Output
Gain Change
C
Standard C-Band
950 - 1525 MHz
4.900 GHz
5.850 - 6.425 GHz
0-4 dB
C
Extended C-Band
950 - 1825 MHz
4.900 GHz
5.850 - 6.725 GHz
0-4 dB
X
Standard X-Band
950 - 1450 MHz
6.950 GHz
7.900 - 8.400 GHz
0-2 dB
Ku
Standard Ku-Band
950 - 1450 MHz
13.050 GHz
14.00 - 14.50 GHz
0-2 dB
Ku
Extended Ku-Band
950 - 1700 MHz
12.800 GHz
13.75 - 14.50 GHz
0-2 dB
Ku
Sub Ku-Band 1
1200 - 1450 MHz
11.800 GHz
13.00 - 13.25 GHz
0-2 dB
Ku
Sub Ku-Band 2
950 - 1450 MHz
11.800 GHz
12.75 - 13.25 GHz
0-2 dB
Electrical Specifications for Mini Compact Outdoor SSPA with BUC PARAMETER Gain Gain Flatness Gain Slope Gain Adjusted Range Gain Stability Phase Noise
Spurious
Noise Figure Input VSWR Internal Reference Option
4 OF 8
NOTES
LIMITS
UNITS
Nominal setting full band (C-,X-,Ku-bands) full band (Extended C-/Ku) per 40 MHz (C-,X-,Ku-bands)
75 ± 2.0 ± 2.5 ± 0.5 20 55 - 75 ± 1.5
dB dB dB dB/40 MHz dB dB dB
Typical Adj. Range -40 to +60 °C Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz
Absolute max. -30 -60 -70 -80 -90 -90
C-band (typ.) -60 -80 -80 -85 -120 -125
X-band (typ.) -60 -75 -75 -100 -110 -122
Ku-band (typ.) -50 -65 -72 -90 -110 -120
dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz
In-Band Signal Related (C-/X-/Ku-Band) (Extended C-Band) Close to Carrier Spurious (< 20 MHz) Local Oscillator Non-Signal Related
-50 -40 -50 -30 -40
dBc dBc dBc dBm dBm
At 75 dB gain setting
20
dB
L-Band
1.5 : 1
Reference accuracy @ 25 °C Reference Stability over Temperature (-20 to +85 °C)
± 3 • 10-7 ± 1.5 • 10-8
209495 REV A ECO 16884
Redundant Systems Mini Compact Outdoor SSPA Amp 1
RF OUT-POL 1
RF IN-POL 1 Amp 2
RF IN-POL 2
1:1 Redundant HPA System, Input Switching
Amp 3
RF OUT-POL 2
1:2 Redundant HPA System, Input Switching
Teledyne Paradise Datacom’s Mini Compact Outdoor Redundant Systems are designed with built-in redundancy for 1:1 systems, so all system-level monitor and control is internal and no separate controller is required, although an optional RCP2-1100 1:1 Redundant Controller is available. Either Ethernet or RS-485 communications are selectable for user monitor and control. All 1:2 redundant systems require a separate RCP2-1200 Redundant Controller.
RCP2-1100 1:1 Redundant Controller
RCP2-1200 1:2 Redundant Controller
The RCP2-1X00 is the heart of the Redundant System. It provides an extremely user friendly interface for complete monitor and control of the high power amplifiers. The front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights are provided for easy indication of system status. All RCP2-1X00 monitor and control is available locally, at the front panel LCD display, as well as remotely by the RS-232 or RS-485 interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel of the RCP2-1X00.
5 OF 8
209495 REV A ECO 16884
Redundant Systems Mini Compact Outdoor SSPA 23.50 [596.9] 22.50 [571.5] (2x)
9.00 [228.6]
11.75 [298.45] (4x)
9.00 [228.6] Ø.39 [Ø9.8]
1.00 [25.4] (2x)
.00 [0]
1.00 [25.4] (3x)
5.57 [141.5]
8.40 [213.36] (2x)
11.75 [298.45]
20.40 [518.16] (2x)
22.50 [571.5] (3x)
23.50 [596.9]
.00 [0]
12.32 [312.92] 11.20 [284.4]
.25 [6.35] .00 [0]
Outline Drawing, Typical Ku-Band Mini Compact Outdoor SSPA 1:1 Redundant System
6 OF 8
209495 REV A ECO 16884
Redundant Systems Mini Compact Outdoor SSPA 23.50 [596.90] 22.50 [571.50] (2x)
9.00 [228.60]
11.75 [298.45]
Ø.39 [Ø9.80]
9.00 [228.60]
.00 [.00] .00 [.00]
1.00 [25.40] (3x)
5.00 [127.00]
8.40 [213.36] (2x)
11.75 [298.45]
20.40 [518.16] (2x)
22.50 [571.50] (3x)
23.50 [596.90]
1.00 [25.40] (2x)
12.57 [319.39] 11.20 [284.40]
.25 [6.35] .00 [.00]
Outline Drawing, Typical C-Band Mini Compact Outdoor SSPA 1:1 Redundant System
7 OF 8
209495 REV A ECO 16884
Redundant Systems Mini Compact Outdoor SSPA Part Number Configuration, Mini Compact Outdoor Systems HPA
3
C
Band CC - C-Band XX - X-Band KU - Ku-Band
Configuration Modifier XXX XMX XTX1 XUX1
Power Level (in Watts) C-Band 075, 100 or 200 X-Band 050, 075, 100 or 200 Ku-Band 050 or 080
Frequency Sub Band C-Band A1 - 5.85 - 6.425 GHz B1 - 5.85 - 6.725 GHz X-Band A1 - 7.90 to 8.40 GHz Ku-Band A1 - 14.00 - 14.50 GHz B1 - 13.75 - 14.50 GHz E1,2 - 13.00 - 13.25 GHz F1,2 - 12.75 - 13.25 GHz
1
= = = =
Standard MS-Connector Covers Transmit Band Filter MS-Connector Covers & Transmit Band Filter
X-Band only.
System Configuration
A1 = 1:1 w/ Input Switching, Internal control B = 1:1 w/ Input Splitter, Internal control C1 = 1:2 w/ Input Switching & RCP2-12002 D1 = 1:2 w/ Input Switching, Internal control F = 1:1 w/ Input Splitter & RCP2-11002 H1 = 1:1 w/ Input Switching & RCP2-11002 S = System (Custom) 1 2
Not available with BUC option P. Standard Cable Length of 100 ft. (30m) with RCP unit.
Block Up Converter A = None (RF Input) M = Internal Reference BUC P = External Reference BUC
Package C = Mini Compact Outdoor
1 2
Available with optional BUC. Not available in 80W Ku-Band units.
Specifications in this document are subject to change without notice. 8 OF 8
209495 REV A ECO 16884