Alcatel OmniPCX Enterprise Hardware description Overview OmniPCX Enterprise Stand Alone 5000 legacy users / 4000 I
Views 201 Downloads 1 File size 612KB
Alcatel OmniPCX Enterprise Hardware description Overview
OmniPCX Enterprise
Stand Alone
5000 legacy users / 4000 IP-Phones 90 Crystal IP-MG/IP-MG Network
50000 Users 100 Nodes R4.2/R4.2.1, R5.0 Ux/Lx and R5.1 will be fully compatible in Network The network link possibilities depend on the hardware configuration used
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Board positioning in racks Rack 1U (Small) CS, GD or MEX CPU
position 1
position 2
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Board positioning in racks Rack 3U (Large)
GD or MEX CPU
position 1
position 2
position 3
position 4
position 5
position 6
position 7
position 8
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Processing units Processing units and daughter boards with their location Name CS GD GA
Function Call Server Media Gateway Driver Media Gateway Applicative 16 Mbits/s link for expansion MEX rack INTIP B ACT-MG over IP link Xmem IDE controller for hard disk Multi Channel Vocoder MCV8 or MCV24 VoIP compression resources 7 or 21 compressors High Speed Link HSL1, HSL2 Expansion cabinet connection Ethernet LAN switch Slanx 3 ports +1 up-link AFU Auxiliary Function Unit
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Location IP MG IP MG IP MG IP MG ACT-MG CS GD,GA GD, MEX CS,GA GD
OmniPCX Enterprise Processing units - "In-the-skin" IP Server (IP RS) CS Can be plugged in slot 8 (3U rack) or in a slot 0 (dedicated rack for e-CS) Connected to the back panel only to get the power supply
Main characteristics Processor : ASPEN 133MHz Memory : S-DRAM 128 MBytes + basic NAND flash 32 MBytes Hard disk Connectors on front panel 1 Ethernet 10/100 Base-T 1 V24 access ON/OFF switch button Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Processing units - "In-the-skin" IP Server (IP RS) CS front panel LAN connection or directly to GD
SlanX accesses (4 ports)
Not used
V24 port (system console)
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
ON/OFF switch
OmniPCX Enterprise Processing units - "In-the-skin" IP Server (IP RS) CS daughter boards
Xmem IDE controller for hard disk (where is located the e-CS software)
SlanX 10/100 Mbits/s base-T ethernet LAN switch 3 crossed ports and 1 straight port (uplink) Auto-negotiation (full/half duplex) Flow control
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Processing units - "In-the-skin" IP Server (IP RS) CS board description
0-11PCM ASL
METRIC
Back panel connector
Xmem daughter board + hard disk
X
XCHANGE
X X
DSP0 DSP1
SLANX Daughter board
µP
SDRAM (128 Mbytes)
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
IP LAN
OmniPCX Enterprise Processing units - Media Gateway Driver GD All the intelligence of the IP Media Gateway is concentrated in the GD (no firmware in other boards)
Always in slot 0 1 Available position
Main characteristics Processor : ASPEN 133MHz
Memory : S-DRAM 64 MBytes + basic NAND flash 32 MBytes Connectors on front panel 1 Ethernet 10/100 Base-T 1 V24 access Switch ON/OFF button Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Processing units - Media Gateway Driver GD front panel LAN connection or directly to CS
expansion rack 1
expansion rack 2
V24 port (config., maintenance)
AFU features
ON/OFF switch for the power supply of the module
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Processing units - Media Gateway Driver GD daughter boards
MADA 1 or 3 DSPs for voice compression in Voice over IP applications. G.711, G.723.1, G.729, DTMF generation and detection, group 3 fax relay.
AFU Connection of external tuner, tape recorder,... Connection of external Loudspeaker.
HSL Two HSL connectors allow connection of up to 2 expansion racks, One HSL consists in 254 Time Slots. Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Processing units - Media Gateway Driver GD board description
0-11PCM ASL
METRIC
Back panel connector
MADA1 or 3 daughter board (VoIP compressors) DSP0
XCHANGE
DSP1
2 * HSL
AFU Daughter board HSL Daughter board
µP
SDRAM (64 Mytes)
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
IP LAN
OmniPCX Enterprise Processing units - GA GA Applicative processing unit plugged in a coupler position of the IP MG Used to provide additional resources VoIP compressors – Number of channels depends on the daughter board used – MADA1 or 3
Voice guides broadcast (4 languages max), 3 x "3 parties conference" – thanks to the GA DSP0
Communication with GD only (using 2 PCM) Other boards are not seen Must be plugged in a coupler position with 2 PCM
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Processing units - GA GA board description
0-11PCM ASL
METRIC
Back panel connector
MADA1 or 3 daughter board (VoIP compressors) DSP0
XCHANGE
DSP1
SLANX Daughter board
µP
SDRAM
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
IP LAN
OmniPCX Enterprise Processing units - MEX Plugged into slot 0 of an expansion rack Insures the control of its remote rack Up to 2 expansion racks can be connected on a main rack Connected to the main rack (GD) through a HSL link 16 Mbits/s link (5 meter shield cable maximum) Using HSL daughter boards The MEX board DSP0 receives from the DSP0 of the GD the switching information A virtual GPA is also associated to each MEX board
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Interface boards : extension interfaces Interface boards N am e U A I 4 ,8 ,1 6 S LI 4 ,8 ,1 6 D EC T8
F u n ctio n 4 ,8 o r 1 6 d ig ita l e q u ip m e n ts 4 ,8 o r 1 6 a n a lo g e q u ip m e n ts In te rfa ce s fo r 8 R a d io B a se S ta tio n s
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Lo ca tio n IP M G IP M G A C T -M G
OmniPCX Enterprise Interface boards : extension interfaces UAI (Universal Alcatel Interface) Digital equipment connection 4, 8 or 16 UA equipments UAG2 UAG3 Attendants IBS TSC and terminal adapters
Restrictions No UAI board in 8th slot of rack Large when MCV24 plugged on the GD (the PCM of the position 8 is reserved for the MCV24) No UAI16 in slot 5 to 8 of rack Large (because only one PCM available) Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Interface boards : extension interfaces SLI (Single Line Interface) Analogue equipments connection Sets Modem Fax
4, 8 or 16 equipments Supports Q23 and decadic dialling mode No MF Q23 detectors (use of DSP0 detectors) Restrictions No SLI16 in rack Small No SLI board in 8th slot of rack L when MCV24 plugged on GD Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Interface boards : external access interfaces Digital access boards (private or public network) Name BRA 2,4,8 PRA T2 PRA T1 PCM2
Function 2,4 or 8 ISDN Basic accesses 1 x 2Mbit/s access 1 x 1,544Mbit/s access 2Mbit/s Pulse Code Modulation interface
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Location IP MG IP MG IP MG ACT-MG
OmniPCX Enterprise Interface boards : external access interfaces Digital interfaces BRA (Basic Rate Interface) T0 interfaces (2B+D) – S0 FV leased line – public ISDN access
2, 4 or 8 accesses S0 mode not available
PRA T1 (Primary Rate Access T1) 1 x 1,544 Mbits T1 interface – public ISDN access – ABC-F Network links
Available in CCS mode (23B+D) or CAS mode (24B)
PRA T2 1 x 2 Mbits E1 (T2) access – public ISDN access, ABC-F Network links Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Interface boards : mixed interfaces Mixed boards (extension and external accesses interfaces) Offers BRA, UA and Z functions Nam e
N u m b e r o f T0
Num ber of UA
Num ber of Z
Lo c a tio n
M IX 4 8 4
4
8
4
IP M G
M IX 4 4 8
4
4
8
IP M G
M IX 2 4 4
2
4
4
IP M G
M IX 0 4 8
0
4
8
IP M G
M IX 0 8 4
0
8
4
IP M G
M IX 0 4 4
0
4
4
IP M G
2 PCMs are required for a MIX board No MIX boards in slot 5 to 8 of rack Large (because only one PCM available)
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Interface boards : external access interfaces
Analogue access boards (public operator, inter PABX) Name APA 4,8 EMTL ACEM
Function 4 or 8 analog interfaces 6 analog trunks for private tie line 4 analog trunks for private tie line
APA 4 or 8 analogue equipment for public/PSTN trunk
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Location IP MG ACT-MG ACT-MG
IP Rack Server Auxiliary boards Auxiliary boards LANX8, LANX16 Switch 10/100 Base T (autodetection) 8 or 16 ports ( 1 is crossed ( Uplink ))
RMA Secured remote access for maintenance
MODB Board supporting 1 external modem To manage the power supply of the rack dedicated to RMA Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Restrictions / limits Maximum number of PRA T1/T2 1 in rack S and 3 in rack L If MCV24 is used in rack L Slot 8 is useless (except for CS) ISDN accesses 12 accesses (T2, T1 and/or T0) maximum per IP MG No S0 on BRA or MIX interfaces Synchronization not transmitted from expansion rack to main rack Only accesses of the main rack can synchronize the whole IP MG Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
OmniPCX Enterprise Boards unplug Warning : To unplug a CPU CS you have first to switch it off The couplers boards are hot pluggable
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Crystal hardware CPU6 Step2 Integration of the CPU id Memory capacity increase (from 64 to128 Mo)
NPRAE (New Primary Rate Access on E1 interface)
2 E1 accesses E1
Various signaling protocols available: T2, ABC-F, QSIG, QSIG_GF & ISDN
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Crystal hardware GPA2-2 (General Purpose Auxiliary) MFR1/MFR2 Frequencies sending MLVP function (Multi Language Voice Prompt)
(2)
Conference function (up to 30 participants)
Usual frequencies detection VAD detection (Voice Activity Detection) At least one detection function whatever the board configuration is (in opposite to the GPA board)
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Crystal hardware INTIP2 (INTerconnecting on IP network)
Main processor update
V24 port connection modification Use of the same cable than the one used for CS, GD & GA boards
Addition of the V36 interface WAN access – 10 Mb/s max on X24/V11 – 1920 Kb/s max on V36
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Crystal hardware eUA32 & eZ32 (Legerity)
Cost reduction for the customer
Specific dedicated licenses are mandatory for UA and Z extensions (check of the UA & Z extensions management)
Impossibility to declare an UA32/Z32 board while using an eUA32/eZ32 board
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Crystal Platform
Crystal hardware - CPU7 CPU7 Replaces the CPU5 Processing unit INTEL PENTIUM III LP processor 700MHz
System memory SDRAM technology – 256 Mb
The embedded Ethernet link can be disabled by software, even if the corresponding on board jumper is present Force the Ethernet output bandwidth to 10 or 100 Mb, Half or Full duplex mode (“auto-sense” is the default mode) Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Crystal hardware - CPU7 CPU7 functionalities IO1 CPU signaling Clock and frame synchronization signals Tones generation Q23 signaling detection – Q23 – Q23x
DECT Timing Module (DTM) function – Synchronization of the IBS and RBS
“External Music” function Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Crystal hardware - CPU7 CPU7 restrictions This Board does not support any daughter boards No VMU No OBCA (use of IO2N(1) if required)
Only one DSP (used for the DTM function) instead two for the CPU6 With CPU6, the second DSP was used for the VPU function (voice Processing Unit)
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Crystal hardware GIP4-1/GIP4-4 compression daughter board Compression daughter board which replaces GIP6 daughter boards on INTIP/INTIP2 boards
Whatever the algorithm (G711, G723 or G729) and depth of echo cancellation are used, a DSP provides 8 compressors
64ms echo cancellation(1) compatibility
Two type of GIP4 GIP4-4 has 4 DSP and can provide up to 32 compressors GIP4-1 has 1 DSP and can provide up to 8 compressors
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Crystal hardware GIP4-1/GIP4-4 compression daughter board When two compression daughter boards on an INTIP2, both must be the same type
2 GIP4-4 or 2 GIP4-1
In case of two GIP4-4, there is only a maximum of 60 (2*30) compressors available on the INTIP/INTIP2 board (because of internal board PCMs) Configuration of the compression daughter board is done at the (“INTIP”) board level (mgr/Shelf / Board “ Review/Modify”)
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Common Platform
Common hardware MADA-1/MADA-3 compression daughter board Compression daughter board which replaces MCV8 and MCV24 daughter boards on GD/GA boards Two types of MADA (configurable at the board level)
(1)
MADA3 has 3 DSP and can provide(2) up to 24 compressors MADA1 has one DSP and can provide up to 8 compressors Whatever the algorithm (G711, G723 or G729) and depth of echo cancellation are used, a DSP provides 8 compressors There is only one MADAx daughter board on a GD/GA 64ms echo cancellation(3) compatibility
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.
Common hardware New Racks Powered by 110V or 220V With/without Battery (R5.1.2)
Offers a low cost alternative to UPS solution
Up to 8 hours autonomy
Reference for the 1U Rack – 110V / 220V
(1)
: 3EH 76020 AEAB
Reference for the 3U Rack – 110V: 3EH 76027 BEAB – 220V: 3EH 76027 AEAB
Alcatel-Lucent – Internal Proprietary – Use pursuant to Company instruction.