F01S100 V100R001 Product Description Issue 01 Date 2009-10-28 Huawei Proprietary and Confidential Copyright © Huaw
Views 82 Downloads 1 File size 2MB
F01S100 V100R001
Product Description
Issue
01
Date
2009-10-28
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, please contact our local office or company headquarters.
Huawei Technologies Co., Ltd. Address:
Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China
Website:
http://www.huawei.com
Email:
[email protected]
Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions and other Huawei trademarks are the property of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but the statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
F01S100 Product Description
Contents
Contents About This Document.....................................................................................................................1 1 Product Feature...........................................................................................................................1-1 1.1 Prominent Security Performance....................................................................................................................1-2 1.2 Prominent Protection Performance.................................................................................................................1-2 1.3 Easy Installation..............................................................................................................................................1-2 1.4 Prominent Monitoring and Maintainability.....................................................................................................1-3 1.5 Compact and Reliable Structure......................................................................................................................1-4
2 Product Structure........................................................................................................................2-1 2.1 Appearance and Dimensions...........................................................................................................................2-2 2.2 Structure..........................................................................................................................................................2-2 2.3 Power System..................................................................................................................................................2-4 2.3.1 AC PDU.................................................................................................................................................2-6 2.3.2 AC Single-phase Lightning Protection Bar............................................................................................2-7 2.3.3 Battery....................................................................................................................................................2-8 2.3.4 Battery Heater........................................................................................................................................2-9 2.3.5 Remote power supply.............................................................................................................................2-9 2.3.6 DC PDU...............................................................................................................................................2-10 2.4 Cable Distribution Device.............................................................................................................................2-10 2.4.1 MDF.....................................................................................................................................................2-10 2.4.2 ODF......................................................................................................................................................2-12 2.5 Temperature Control Unit.............................................................................................................................2-13 2.6 Monitoring System........................................................................................................................................2-14 2.6.1 Monitoring Scheme..............................................................................................................................2-14 2.6.2 Sensor...................................................................................................................................................2-15
3 System Configuration...............................................................................................................3-1 3.1 F01S100 cabinet Configured with the MA5610.............................................................................................3-2 3.2 F01S100 cabinet Configured with the MA5616.............................................................................................3-2
4 System Parameters.....................................................................................................................4-1 5 Environmental Specifications..................................................................................................5-1 6 Standards Compliance..............................................................................................................6-1 Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
i
F01S100 Product Description
Contents
7 Acronyms and Abbreviations..................................................................................................7-1
ii
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
Figures
Figures Figure 1-1 The installation of the F01S100 cabinet ............................................................................................1-3 Figure 2-1 Appearance and dimensions of the F01S100 cabinet.........................................................................2-2 Figure 2-2 Structure of the F01S100 cabinet.......................................................................................................2-3 Figure 2-3 Power distribution scheme of the F01S100 cabinet...........................................................................2-5 Figure 2-4 Appearance of battery.........................................................................................................................2-8 Figure 2-5 Appearance of the MDF in the F01S100 cabinet.............................................................................2-11 Figure 2-6 Appearance of the ODF in the F01S100 cabinet..............................................................................2-13 Figure 2-7 Monitoring scheme of the F01S100 cabinet.....................................................................................2-14 Figure 2-8 Appearance of the door status sensor...............................................................................................2-15
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
iii
F01S100 Product Description
Tables
Tables Table 2-1 Structure of the F01S100 cabinet (configured with the AC-powered MA5610/MA5616).................2-4 Table 2-2 Structure of the F01S100 cabinet (configured with the DC-powered MA5610/MA5616).................2-4 Table 2-3 Specifications of the lightning arrester................................................................................................2-6 Table 2-4 Technical specifications of the maintenance socket............................................................................2-7 Table 2-5 Technical specifications of the AC single-phase lightning protection bar...........................................2-7 Table 2-6 Technical specifications of battery.......................................................................................................2-8 Table 2-7 Technical specifications of the battery heater......................................................................................2-9 Table 2-8 Technical specifications of the remote power supply........................................................................2-10 Table 2-9 Specifications of the MDF in the F01S100 cabinet...........................................................................2-11 Table 2-10 Specifications of the ODF................................................................................................................2-13 Table 2-11 Technical parameters of the heat dissipation fan.............................................................................2-14 Table 3-1 Number of subscribers supported by the F01S100 cabinet in different configurations.......................3-2 Table 3-2 Number of subscribers supported by the F01S100 cabinet in different configurations.......................3-2 Table 4-1 Dimensions of the F01S100 cabinet....................................................................................................4-1 Table 4-2 Weight of the F01S100 cabinet............................................................................................................4-1 Table 4-3 Power of the F01S100 cabinet.............................................................................................................4-1 Table 5-1 Environment specifications of the F01S100 cabinet............................................................................5-1 Table 6-1 Standards compliance of the F01S100 cabinet....................................................................................6-1
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
v
F01S100 Product Description
About This Document
About This Document Overview The F01S100 cabinet can hold the MA5610 and MA5616. The F01S100 cabinet is a smallcapacity device that can provide the LAN, POTS, ADSL2+, and VDSL2 services for the subscriber. This document describes the product feature, product structure, system configuration,system parameters,environmental specifications,standards compliance and acronyms and abbreviations of the F01S100 cabinet.
Related Version The following table lists the product version related to this document. Product Name
Version
MA5610/MA5616
V800R307
Intended Audience The intended audience of this document is: l
Network planning engineers
l
Installation and commissioning engineers
l
Field maintenance engineers
l
Network monitoring engineers
l
System maintenance engineers
l
Data configuration engineers
l
Application developers
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
1
F01S100 Product Description
About This Document
Organization The F01S100 cabinetis an indoor and front access cabinet of a small capacity. The following table lists the contents of the document. Chapter...
Describes...
1 Product Feature
The security performance, protection performance, installation method, and structure of the F01S100 cabinet.
2 Product Structure
The appearance, structure, and parameters of the F01S100 cabinet, and the functions of the components.
3 System Configuration
The configuration of the F01S100 cabinet.
4 System Parameters
The dimensions, weight, power consumption, configuration and environmental parameters of the F01S100 cabinet.
5 Environmental Specifications
The environmental parameters of the F01S100 cabinet.
6 Standards Compliance
The standards that the F01S100 cabinet complies with in terms of environment, structure, power system, and lighting protection.
7 Acronyms and Abbreviations
The acronyms and abbreviations used in this document.
Conventions Symbol Conventions The following symbols may be found in this document. They are defined as follows. Symbol
Description Indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Indicates a hazard with a medium or low level of risk which, if not avoided, could result in minor or moderate injury. Indicates a potentially hazardous situation that, if not avoided, could cause equipment damage, data loss, and performance degradation, or unexpected results. Indicates a tip that may help you solve a problem or save your time.
2
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
About This Document
Symbol
Description Provides additional information to emphasize or supplement important points of the main text.
General Conventions Convention
Description
Times New Roman
Normal paragraphs are in Times New Roman.
Boldface
Names of files, directories, folders, and users are in boldface. For example, log in as user root.
Italic
Book titles are in italics.
Courier New
Terminal display is in Courier New.
Command Conventions Convention
Description
Boldface
The keywords of a command line are in boldface.
Italic
Command arguments are in italic.
[]
Items (keywords or arguments) in square brackets [ ] are optional.
{ x | y | ... }
Alternative items are grouped in braces and separated by vertical bars. One is selected.
[ x | y | ... ]
Optional alternative items are grouped in square brackets and separated by vertical bars. One or none is selected.
{ x | y | ... } *
Alternative items are grouped in braces and separated by vertical bars. A minimum of one or a maximum of all can be selected.
GUI Conventions
Issue 01 (2009-10-28)
Convention
Description
Boldface
Buttons, menus, parameters, tabs, window, and dialog titles are in boldface. For example, click OK.
>
Multi-level menus are in boldface and separated by the ">" signs. For example, choose File > Create > Folder.
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
3
F01S100 Product Description
About This Document
Keyboard Operation Format
Description
Key
Press the key. For example, press Enter and press Tab.
Key 1+Key 2
Press the keys concurrently. For example, pressing Ctrl +Alt+A means the three keys should be pressed concurrently.
Key 1, Key 2
Press the keys in turn. For example, pressing Alt, A means the two keys should be pressed in turn.
Mouse Operation Action
Description
Click
Select and release the primary mouse button without moving the pointer.
Double-click
Press the primary mouse button twice continuously and quickly without moving the pointer.
Drag
Press and hold the primary mouse button and move the pointer to a certain position.
Update History Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions.
Updates in Issue 01 (2009-10-28) This is the first release.
4
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
1 Product Feature
1
Product Feature
About This Chapter This topic describes the security performance, protection performance, installation method, monitoring, maintenance, and structure of the F01S100 cabinet. 1.1 Prominent Security Performance The F01S100 cabinet features prominent security performance to comply with the international safety standards. 1.2 Prominent Protection Performance The F01S100 cabinet features prominent protection performance to meet the requirements of the outdoor or the indoor environment that does not have any protection. 1.3 Easy Installation The F01S100 cabinet can be installed on the wall, on a pole, or on a concrete pedestal. 1.4 Prominent Monitoring and Maintainability The structure of the F01S100 cabinet meets the requirements of real-time monitoring and easy maintenance. 1.5 Compact and Reliable Structure The compact design of the F01S100 cabinet facilitates the installation of the F01S100 cabinet and ensures that the F01S100 cabinet runs reliably.
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
1-1
F01S100 Product Description
1 Product Feature
1.1 Prominent Security Performance The F01S100 cabinet features prominent security performance to comply with the international safety standards. l
The F01S100 cabinet features prominent protection performance and anti-attack performance.
l
The F01S100 cabinet uses the HW-2802A lock to secure the cabinet door and serve as an anti-theft measure.
1.2 Prominent Protection Performance The F01S100 cabinet features prominent protection performance to meet the requirements of the outdoor or the indoor environment that does not have any protection. l
When the F01S100 cabinet is configured with the MA5610/MA5616 (device that uses the forced air cooling mode for heat dissipation), the F01S100 cabinet provides the IP protection rating of the integrated device reaches IP55 ("IP" refers to International Protection. The first number "5" refers to the class for preventing the solid particle from entering the device. That is, the cabinet cannot completely prevent dust from entering the device, but the amount of dust that enters the cabinet does not damage the device. The second number "5" refers to the class for preventing water from entering the cabinet. That is, the water sprayed from different directions to the cabinet does not damage the device.).
l
The built-in lightning arrester in the AC PDU or AC single-phase lightning protection bar protects the AC power supply.
l
The built-in external line protection unit (optional) and the service boards provide 2-level protection for the service ports and meet the requirements of the K-45 protection index.
1.3 Easy Installation The F01S100 cabinet can be installed on the wall, on a pole, or on a concrete pedestal. The F01S100 cabinet can be easily installed. l
The F01S100 cabinet has firm mounting brackets on its top and thus can be hoisted in a safe and reliable way.
l
The F01S100 cabinet provides a marking-off plate. During the installation, you can use the marking-off plate to determine the installation position of the cabinet. As a result, you need to carry the cabinet only once.
l
The wall mounting installation parts of the F01S100 cabinet enable you to install the F01S100 cabinet on the wall that has the surface differences smaller than 10 mm. This lowers the risk of installing the cabinet.
Figure 1-1 shows the installation of the F01S100 cabinet
1-2
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
1 Product Feature
Figure 1-1 The installation of the F01S100 cabinet
1.4 Prominent Monitoring and Maintainability The structure of the F01S100 cabinet meets the requirements of real-time monitoring and easy maintenance. Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
1-3
F01S100 Product Description
1 Product Feature l
The F01S100 cabinet monitors the states of the internal ambient temperature, door status, lightning arrester (optional), heat dissipation fan (optional), and major alarms of the remote power supply in real time to support the remote alarming function.
l
The F01S100 cabinet (configured with AC-powered MA5610/MA5616) provides an AC power socket to supply power to the maintenance terminal and implement on-site maintenance.
1.5 Compact and Reliable Structure The compact design of the F01S100 cabinet facilitates the installation of the F01S100 cabinet and ensures that the F01S100 cabinet runs reliably.
1-4
l
When the F01S100 cabinet configured with the AC-powered MA5610/MA5616, it integrates the AC-powered MA5610/MA5616, main distribution frame (MDF), optical distribution frame (ODF), AC PDU, battery (optional), battery heater (optional) and enhanced heat dissipation module (optional). The F01S100 cabinet can be installed quickly on site to meet the requirement for quick deployment.
l
When the F01S100 cabinet configured with the DC-powered MA5610/MA5616, it integrates the DC-powered MA5610/MA5616, MDF, ODF, remote power supply, DC PDU and enhanced heat dissipation module (optional). The F01S100 cabinet can be installed quickly on site to meet the requirement for quick deployment.
l
The ventilation design of the F01S100 cabinet can ensure that the F01S100 cabinet runs reliably in the outdoor or indoor environment when the F01S100 cabinet is not configured with any air conditioner.
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
2 Product Structure
2
Product Structure
About This Chapter This topic describes the appearance, structure, component function, and related technical parameter of the F01S100 cabinet. 2.1 Appearance and Dimensions This topic shows the appearance and dimensions of the F01S100 cabinet. 2.2 Structure This topic describes the structure of the F01S100 cabinet when it is configured with different devices. 2.3 Power System The F01S100 cabinet uses the optional AC PDU or AC single-phase lightning protection bar to support the AC-powered MA5616/MA5610. It can also use the remote power supply to support the DC-powered MA5616/MA5610. 2.4 Cable Distribution Device The F01S100 cabinet is configured with the built-in MDF and ODF. The MDF is used to connect the internal subscriber cable and the external subscriber cable. The ODF is used to connect the optical fiber and the optical communication device. 2.5 Temperature Control Unit This topic provides the technical parameters of the built-in temperature control unit used in the F01S100 cabinet. 2.6 Monitoring System This topic describes the monitoring scheme and the built-in sensors of the F01S100 cabinet.
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
2-1
F01S100 Product Description
2 Product Structure
2.1 Appearance and Dimensions This topic shows the appearance and dimensions of the F01S100 cabinet. Figure 2-1 shows the appearance and dimensions of the F01S100 cabinet. Figure 2-1 Appearance and dimensions of the F01S100 cabinet
2.2 Structure This topic describes the structure of the F01S100 cabinet when it is configured with different devices.
2-2
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
2 Product Structure NOTE
The F01S100 cabinet provides a space of 4 U for installing devices and can be configured with the following devices: l
One AC-powered MA5610/MA5616. During installation, the AC-powered MA5610/MA5616 must be installed at the outermost 2 U position to facilitate heat dissipation and future maintenance.
l
One DC-powered MA5610/MA5616 + one remote power supply + one DC PDU. During installation, the DC-powered MA5610/MA5616 must be installed at the outermost 2 U position to facilitate heat dissipation and future maintenance; the DC PDU must be installed at the inmost 1 U position.
Figure 2-2 shows the structure of the F01S100 cabinet. The advantages of the F01S100 cabinet structure are as follows: l
The F01S100 cabinet can be installed and maintained from its front. Cables and boards can be installed or removed easily.
l
The low-noise design is excellent. The noise is lowered to 35 dBA at nights, which is as quiet as in a library.
l
The F01S100 cabinet provides the excellent cabling management function.
l
The F01S100 cabinet supports up to 256 narrowband lines, which is the largest capacity for the products of the same type in the industry.
Figure 2-2 Structure of the F01S100 cabinet
Configured with the AC-powered MA5610/MA5616 Table 2-1 shows the structure of the F01S100 cabinet configured with the AC-powered MA5610/MA5616. Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
2-3
F01S100 Product Description
2 Product Structure
Table 2-1 Structure of the F01S100 cabinet (configured with the AC-powered MA5610/ MA5616) Item
Component Name
Service device
One AC-powered MA5610/MA5616
Power system
l
AC PDU
l
Battery (optional)
l
Battery Heater (optional)
Cable distribution device
l
MDF
l
ODF
Temperature control unit
Enhanced heat dissipation module (optional)
Monitoring system
Sensor (optional)
Configured with the DC-powered MA5610/MA5616 Table 2-2 shows the structure of the F01S100 cabinet configured with the DC-powered MA5610/MA5616. Table 2-2 Structure of the F01S100 cabinet (configured with the DC-powered MA5610/ MA5616) Item
Component Name
Service device
One DC-powered MA5610/MA5616
Power system
Remote power supply / DC PDU
Cable distribution device
l
MDF
l
ODF
Temperature control unit
Enhanced heat dissipation module (optional)
Monitoring system
Sensor (optional)
2.3 Power System The F01S100 cabinet uses the optional AC PDU or AC single-phase lightning protection bar to support the AC-powered MA5616/MA5610. It can also use the remote power supply to support the DC-powered MA5616/MA5610. Figure 2-3 shows the power distribution scheme of the F01S100 cabinet 2-4
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
2 Product Structure
Figure 2-3 Power distribution scheme of the F01S100 cabinet
2.3.1 AC PDU This topic describes the power distribution scheme and the related technical specifications of the built-in AC PDU (optional) in the F01S100 cabinet. 2.3.2 AC Single-phase Lightning Protection Bar This topic describes the power distribution scheme and the related technical specifications of the built-in AC single-phase lightning protection bar (optional) in the F01S100 cabinet. 2.3.3 Battery Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
2-5
F01S100 Product Description
2 Product Structure
When the F01S100 cabinet is configured with the AC-powered MA5610/MA5616, batteries can be selected as the backup power supply. 2.3.4 Battery Heater This topic describes the technical specifications of the battery heater used in the F01S100 cabinet. 2.3.5 Remote power supply When configured with the DC-powered MA5610/MA5616, the F01S100 cabinet uses the remote power supply as its DC power input. 2.3.6 DC PDU This topic describes technical specifications of the built-in DC PDU in the F01S100 cabinet.
2.3.1 AC PDU This topic describes the power distribution scheme and the related technical specifications of the built-in AC PDU (optional) in the F01S100 cabinet. The AC PDU consists of the lightning arrester, maintenance socket, and MCB.
Lightning Arrester The lightning arrester protects the 220 V single-phase power system against the surge voltage caused by the lightning. Table 2-3 lists the technical specifications of the lightning arrester. Table 2-3 Specifications of the lightning arrester Item
Value
Rated voltage
220 VAC
Maximum continuous running voltage (Uc)
380 VAC
Rated discharge current (In)
20 kA (8/20 μs)
Maximum discharge current (Imax)
40 kA (8/20 μs)
Protection rating (Up)
l
< 1.5kV (8/20 μs, 5 kA)
l
< 1.8kV (8/20 μs, 15 kA)
Response time
≤ 25 ns
Dimensions
100 mm x 65 mm x 72 mm
Environment for usage
l
Temperature: –40°C to +70°C
l
Relative humidity: ≤ 95%
Maintenance Socket The maintenance socket is connected to the maintenance terminal to facilitate the on-site maintenance. Table 2-4 lists the technical specifications of the maintenance socket. 2-6
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
2 Product Structure
Table 2-4 Technical specifications of the maintenance socket Item
Value
220 VAC power supply
220 VAC/3 A
MCB The MCB controls the external AC input.
2.3.2 AC Single-phase Lightning Protection Bar This topic describes the power distribution scheme and the related technical specifications of the built-in AC single-phase lightning protection bar (optional) in the F01S100 cabinet. Table 2-5 lists the technical specifications of the AC single-phase lightning protection bar used in the F01S100 cabinet. Table 2-5 Technical specifications of the AC single-phase lightning protection bar Item
Value
Rated working voltage
250 VAC
Maximum continuous running voltage (Uc)
385 VAC
Working frequency
47 Hz to 63 Hz
Rated working current
8A
Fuse current
8A
Fuse type
Slow-blow
Protection mode
L-N, L-PE, and N-PE
Rated through-current capacity (In)
5 kA (8/20 μs)
Maximum discharge current (Imax)
15 kA (8/20 μs)
Voltage protection rating (Up)
1500 V (8/20 us)
LED for improper grounding
Off: normal Red and on: An alarm is generated.
LED for polarity reversal
Off: normal Yellow and on: An alarm is generated.
LED for lightning protection
Off: normal Red and on: The lightning protection fails.
Issue 01 (2009-10-28)
Type of socket hole
Versatile
Number of socket holes
3 bits
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
2-7
F01S100 Product Description
2 Product Structure
Item
Value
Shell protection rating
IP20
Flame retardant rating
94-V0
Response time
Ta ≤ 25 ns
Cable specifications
With a diameter of 8 mm and a length of 2 m
Working temperature
–40°C to +70°C
Storage temperature
–40°C to +85°C
Relative humidity
5% to 95%
Dimensions (W x D x H)
288 mm x 58 mm x 46 mm
2.3.3 Battery When the F01S100 cabinet is configured with the AC-powered MA5610/MA5616, batteries can be selected as the backup power supply. The AC-powered MA5610/MA5616 provides the interface for batteries. NOTE
When the F01S100 cabinet is configured with the AC-powered MA5610/MA5616, a set (four batteries) of 12 Ah batteries can be selected as the backup power supply.
Figure 2-4 shows appearance of battery. Figure 2-4 Appearance of battery
Table 2-6 lists the technical specifications of the batteries used in the F01S100 cabinet. Table 2-6 Technical specifications of battery
2-8
Item
Value
Rate working voltage (when configured with four batteries)
–48 VDC
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
2 Product Structure
Item
Value
Rated capacity
12 Ah
Floating charging voltage of the battery set
–54 VDC
Maximum charging current
3.6 A
Voltage of a single battery
–12 VDC
Working temperature range
–15°C to +50°C
Dimensions of a single battery (W x D x H)
151 mm x 100 mm x 98 mm
Weight of a single battery
3.83 kg
2.3.4 Battery Heater This topic describes the technical specifications of the battery heater used in the F01S100 cabinet. NOTE
Two battery heaters must be configured when the F01S100 cabinet is used in the area where the ambient temperature is below 0°C.
Table 2-7 lists the technical specifications of the battery heater used in the F01S100 cabinet. Table 2-7 Technical specifications of the battery heater Item
Value
Rated voltage
220 VAC
Voltage range
150 VAC to 300 VAC
Rated heating power
70 W
Insulation resistance
The insulation resistance between the heater leading power cable and the heater shell must be greater than 10 megohms.
Working environment
The heater can work reliably in the environment with relative humidity of 5% to 95%.
Dimensions (L x W x D)
180 mm x 125 mm x 2 mm
2.3.5 Remote power supply When configured with the DC-powered MA5610/MA5616, the F01S100 cabinet uses the remote power supply as its DC power input. Table 2-8 lists the technical specifications of the remote power supply used in the F01S100 cabinet. Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
2-9
F01S100 Product Description
2 Product Structure
Table 2-8 Technical specifications of the remote power supply Item
Value
Input rated voltage
340 VDC (+/-170 VDC)
Input voltage range
285 VDC to 348 VDC
Output rated voltage
–48 VDC
Output voltage range
–40 VDC to –57 VDC
Cooling method
Forced air cooling
Working temperature range
-40℃ to +70℃
Storage temperature range
-40℃ to +80℃
Weight
2.5 kg
Dimensions (W x D x H)
445 mm x 230 mm x 44.5 mm
2.3.6 DC PDU This topic describes technical specifications of the built-in DC PDU in the F01S100 cabinet. The DC PDU consists of the MCB. The MCB controls the -48 VDC output of the remote power supply.
2.4 Cable Distribution Device The F01S100 cabinet is configured with the built-in MDF and ODF. The MDF is used to connect the internal subscriber cable and the external subscriber cable. The ODF is used to connect the optical fiber and the optical communication device. 2.4.1 MDF This topic describes the specifications of the built-in MDF in the F01S100 cabinet. 2.4.2 ODF This topic provides the appearance of the built-in ODF in the F01S100 cabinet and describes the capacity specifications of the ODF.
2.4.1 MDF This topic describes the specifications of the built-in MDF in the F01S100 cabinet.
2-10
l
The 16-pair exchange side terminal blocks are installed to be connected with the internal cables of the MDF and the jumper cables. The exchange side terminal blocks are also used for tests and open circuits.
l
The 10-pair cable side terminal blocks are installed to be connected with the external cables of the MDF and the jumper cables. The protective unit (optional) installed in the cable side terminal block provides the overvoltage protection and generates alarms. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
2 Product Structure l
The harness, which consists of the connector, subscriber cable, and terminal block, provides connections between the service boards and the MDF.
Figure 2-5 shows the appearance of the MDF in the F01S100 cabinet. Figure 2-5 Appearance of the MDF in the F01S100 cabinet
Table 2-9 lists the specifications of the MDF. Table 2-9 Specifications of the MDF in the F01S100 cabinet
Issue 01 (2009-10-28)
Item
Value
Type of the exchange side terminal block
JPX658-STO-236XD (White)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
2-11
F01S100 Product Description
2 Product Structure
Item
Value
Height of the exchange side terminal block
12 mm
Type of the cable side terminal block
l
JPX658-FA8-239XB (White)
l
JPX658-FA8-239XH (Yellow)
l
JPX658-BLK2-E10VB (White)
l
JPX658-BLK2-E10VH (Yellow)
l
JPX658-FA8-239XB (15 mm)
l
JPX658-FA8-239XH (15 mm)
l
JPX658-BLK2-E10VB (13 mm)
l
JPX658-BLK2-E10VH (13 mm)
l
JPX658-FA9-280J
l
JPX658-FA10-97
l
JPX658-SPD2-G400T
l
JPX658-VPS3-Y600-VDSL2
l
JPX658-VPS3-E270A-VDSL2
l
JPX658-VPS3-E270B-VDSL2
l
JPX658-VPS3-E320-VDSL2
Height of the cable side terminal block
Type of the protective unit
Type of the SPL
Height of the MDF
680 mm, which can be adjusted flexibly.
2.4.2 ODF This topic provides the appearance of the built-in ODF in the F01S100 cabinet and describes the capacity specifications of the ODF. The ODF is used to connect the optical fiber and the optical communication device. The ODF can perform the following functions: l
Fasten and protect optical fibers.
l
Protect the cores of the peeled optical fibers.
l
Distribute optical fibers.
l
Adjust optical fibers.
l
Store optical fibers.
Figure 2-6 shows the appearance of the ODF in the F01S100 cabinet.
2-12
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
2 Product Structure
Figure 2-6 Appearance of the ODF in the F01S100 cabinet
Table 2-10 lists the specifications of the built-in ODF in the F01S100 cabinet. Table 2-10 Specifications of the ODF ODF Type
Port Type
Capacity
ODF (simple)
FC/PC
6 adapters (default configuration: 2 adapters)
2.5 Temperature Control Unit This topic provides the technical parameters of the built-in temperature control unit used in the F01S100 cabinet. The F01S100 cabinet uses the heat exchanger mounted on the cabinet wall for heat dissipation. Besides, the cabinet can also be configured with a enhanced heat dissipation module to further improve the heat dissipation performance and to meet the requirement of the environment with a temperature higher than 45°C (When the solar radiation intensity is 1120 W/m2, the highest environment temperature is 50°C). The enhanced heat dissipation consists of two heat dissipation fans. Table 2-11 describes the technical parameters of the heat dissipation fan.
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
2-13
F01S100 Product Description
2 Product Structure
Table 2-11 Technical parameters of the heat dissipation fan Item
Value
Rated voltage
-48 VDC
Running voltage
–28 VDC to –54 VDC
Input current
0.17 A
Running power
8.16 W
Rotating speed
3700 rpm
Wind volume
81.97 CFM
Dimensions
92 mm x 92 mm x 25.4 mm
2.6 Monitoring System This topic describes the monitoring scheme and the built-in sensors of the F01S100 cabinet. 2.6.1 Monitoring Scheme The service chassis installed in the F01S100 cabinet monitors the environment and key components of the cabinet. 2.6.2 Sensor This topic provides the appearances of the built-in sensors in the F01S100 cabinet and provides the information about the functions of the sensors.
2.6.1 Monitoring Scheme The service chassis installed in the F01S100 cabinet monitors the environment and key components of the cabinet. Figure 2-7 shows the monitoring scheme of the F01S100 cabinet. Figure 2-7 Monitoring scheme of the F01S100 cabinet
2-14
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
2 Product Structure
2.6.2 Sensor This topic provides the appearances of the built-in sensors in the F01S100 cabinet and provides the information about the functions of the sensors.
Door status sensor The door status sensor uses the door status switch as the probe. The door status switch consists of two built-in parts. The spring clips of the door status switch attract each other due to electromagnetic interaction. The door status switch monitors the status of the cabinet door, and outputs the dry contact output signals that do not have polarity. Figure 2-8 shows the appearance of the door status sensor. Figure 2-8 Appearance of the door status sensor
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
2-15
F01S100 Product Description
3 System Configuration
3
System Configuration
About This Chapter This topic provides the number of subscribers supported by the F01S100 cabinet. 3.1 F01S100 cabinet Configured with the MA5610 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5610. 3.2 F01S100 cabinet Configured with the MA5616 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5616.
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
3-1
F01S100 Product Description
3 System Configuration
3.1 F01S100 cabinet Configured with the MA5610 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5610. Table 3-1 lists the number of subscribers supported by the F01S100 cabinet in different configurations. Table 3-1 Number of subscribers supported by the F01S100 cabinet in different configurations Configuration
Maximum Number of Subscribers
One MA5610 (configured with four ASPB boards)
256 POTS
One MA5610 (configured with three EIUA boards + one ASPB board)
48 LAN + 64 POTS
One MA5610 (configured with two EIUA boards + two ASPB boards)
32 LAN + 128 POTS
One MA5610 (configured with one EIUA board + three ASPB boards)
16 LAN + 192 POTS
NOTE
l
The ASPB board is the 64-channel narrowband service board that provides the POTS service.
l
The EIUA board is the 16-channel Ethernet access board that provides the LAN service.
In Table 3-1, the number of subscribers is counted when the cabinet is configured with the device provided by Huawei. For details of the device, see the MA5610 Hardware Description.
3.2 F01S100 cabinet Configured with the MA5616 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5616. Table 3-2 lists the number of subscribers supported by the F01S100 cabinet in different configurations. Table 3-2 Number of subscribers supported by the F01S100 cabinet in different configurations
3-2
Configuration
Maximum Number of Subscribers
One MA5616 (configured with four ASPB boards)
256 POTS
One MA5616 (configured with four ADLE boards)
128 ADSL2+
One MA5616 (configured with one ASPB board + three ADLE boards)
64 POTS + 96 ADSL2+
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
3 System Configuration
Configuration
Maximum Number of Subscribers
One MA5616 (configured with four VDSE/VDSH/ VDTH boards)
96 VDSL2
One MA5616 (configured with two ASPB boards + two VDSE/VDSH boards)
128 POTS + 48 VDSL2
NOTE
l
The ASPB board is the 64-channel narrowband service board that provides the POTS service.
l
The ADLE board is the 32-channel ADSL2+ service board with a built-in splitter. It provides the ADSL2+ services.
l
The VDSE board is the 24-channel VDSL2 service board with a built-in splitter. It provides the VDSL2 service.
l
The VDSH board is the 24-channel VDSL2 service board without a built-in splitter. It provides the VDSL2 service.
l
The VDTH board is the 24-channel VDSL2 service board without a built-in splitter. It provides the VDSL2 service.
l
The VDGE board is the 16-channel VDSL2 service board with a built-in splitter. It provides the VDSL2 service.
In Table 3-2, the number of subscribers is counted when the cabinet is configured with the device provided by Huawei. For details of the device, see the MA5616 Hardware Description.
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
3-3
F01S100 Product Description
4 System Parameters
4
System Parameters
This topic provides the parameters of the F01S100 cabinet. Table 4-1 lists the dimensions of the F01S100 cabinet. Table 4-1 Dimensions of the F01S100 cabinet Item
Dimensions (W x D x H)
F01S100 cabinet (without battery compartment)
720 mm x 250 mm x 830 mm
F01S100 cabinet (with battery compartment)
720 mm x 250 mm x 1030 mm
Table 4-2 lists the weight of the F01S100 cabinet. Table 4-2 Weight of the F01S100 cabinet Item
Weight
F01S100 cabinet (without battery compartment, fullyloaded)
57 kg
F01S100 cabinet (fully-loaded, with battery compartment, fully-loaded)
84 kg
Table 4-3 lists the power of the F01S100 cabinet. Table 4-3 Power of the F01S100 cabinet
Issue 01 (2009-10-28)
Item
Value
Maximum power of the F01S100 cabinet (configured with the AC-powered MA5610/MA5616)
187.6 W
Maximum power of the F01S100 cabinet (configured with the DC-powered MA5610/MA5616)
250 W
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
4-1
F01S100 Product Description
5 Environmental Specifications
5
Environmental Specifications
This topic describes the environmental specifications for the storage, transportation, and running of the cabinet. Table 5-1 lists the environment specifications for the storage, transportation, and running of the F01S100 cabinet. Table 5-1 Environment specifications of the F01S100 cabinet Environment
Item
Value
Storage
Solar radiation intensity
≤1120 W/m2
Temperature
–45°C to +45°C
Relative humidity
8% to 100%
Air pressure
70 kPa to 106 kPa
Solar radiation intensity
≤1120 W/m2
Temperature
–40°C to +70°C
Relative humidity (without much variation in temperature)
95% (+45°C)
Relative humidity (with much variation in temperature: air/air)
95% (-40°C to +30°C)
Air pressure
≥ 70 kPa
Solar radiation intensity
≤1120 W/m2
Temperature (when the F01S100 cabinet is configured with one MA5610/MA5616, without the enhanced heat dissipation module and )
–33°C to +45°C
Temperature (when the F01S100 cabinet is configured with one MA5610/MA5616, with the enhanced heat dissipation module and )
–33°C to +50°C
Transportation
Running
Issue 01 (2009-10-28)
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
5-1
F01S100 Product Description
5 Environmental Specifications
Environment
5-2
Item
Value
Relative humidity
8% to 100%
Air pressure
70 kPa to 106 kPa
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
6 Standards Compliance
6
Standards Compliance
This topic provides the standards that the F01S100 cabinet complies with in terms of the environment, structure, power system and lightning proof. Table 6-1 provides the standards compliance of the F01S100 cabinet. Table 6-1 Standards compliance of the F01S100 cabinet
Issue 01 (2009-10-28)
Item
Standards Compliance
Class
Running environment
ETSI EN 300 019-1-4: Environmental conditions and environmental test for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at nonweather protected locations
Class 4.1E Nonweatherprotected locationsextended
Transportation environment
ETSI 300 019 – 1 - 2: Environmental conditions and environmental test for telecommunications equipment; Part 1-2: Classification of environmental conditions; Transportation
Class 2.2 Public transportation
Storage environment
ETSI EN 300 019–1–1
Class 1.3E
Safety
IEC 60950–1/ IEC 60065: Safety of information of technology equipment
Necessary
Protection
IEC 60950-22: Degrees of protection provided by enclosures (IP code)
IP55
Noise
ETSI EN 300 753 1997-10
Class 4.1 Rural
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
6-1
F01S100 Product Description
6 Standards Compliance
6-2
Structure
IEC 297_1 (2,3): Cabinets and Pitches of racks structure
-
MDF
K.45: Resistibility of telecommunication equipment installed in the access and trunk networks to overvoltage and overcurrent
-
YD 694-2004
-
Lightning proof
ITU-T K.45: Performance requirement for surge protective device connected to low-voltage distribution systems of telecommunication stations/ sites
Necessary
Grounding
ETSI EN 300 253: Earthing and bonding of telecommunication equipment in telecommunication centers
Necessary
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)
F01S100 Product Description
7 Acronyms and Abbreviations
7
Acronyms and Abbreviations
A AC
Alternating current
ADSL
Asymmetrical digital subscriber line
ADSL2+
Asymmetrical digital subscriber line 2 plus
D DC
Direct current
E EMC
Electro magnetic compatibility
EMU
Environment monitoring unit
EN
End node
ETS
European Telecommunication Standard
ETSI
European Telecommunications Standards Institute
F FE
Fast Ethernet
G GE
Gigabit Ethernet
I IDC Issue 01 (2009-10-28)
Internet data center Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
7-1
F01S100 Product Description
7 Acronyms and Abbreviations
IEC
International Electrotechnical Commission
IEEE
Institute of Electrical and Electronics Engineers
IP
Internet protocol
ITU-T
International Telecommunication Union - Telecommunication Standardization Sector
L LAN
Local area network
M MDF
Main distribution frame
O ODF
Optical distribution frame
P POTS
Plain old telephone service
PSTN
Public switched telephone network
V
7-2
VDSL
Very high speed digital subscriber line
VDSL2
Very high speed digital subscriber line 2
Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009-10-28)