Citation preview

LEGEND C-1 Regrinding hydrocyclone feeder C-2 O/F regringding cyclone C-3 U/F regringding cyclone C-4 Discharging of regrinding mill C-5 Copper cleaner feed C-6 Copper cleaner concentrate C-7 Copper cleaner tailings C-8 copper concentrate thickener feed C-9 U/F concentrate thickener C-10 O/F concentrate thickener C-11 Cleaner scavenger feed C-12 Cleaner scavenger concentrate C-13 Cleaner scavenger tailings

010

MILK OF LIME 000-FS-T-001

002

FROM BULK CONCENTRATE CONDITIONING TANK

M

C2

COPPER REGRIND MILL CYCLONE CLUSTER CYCLONE (13)

MOLY ROUGHER FLOTATION CELLS (4) M

HOLD

C5

M M HOLD

COPPER CLEANER FEED ROTARY DISTRIBUTOR

C1

C3

COPPER REGRIND MILL (1)

C4

COPPER CLEANER FLOTATION COLUMNS (4)

BY VENDOR

C6

M

COPPER CLEANER SCAVENGER FLOTATION CELLS (4)

C11

COPPER REGRIND MILL MOLY ROUGHER CYCLONES FEED CONCENTRATE PUMPBOX PUMPBOX

C10 COPPER CONCENTRATE THICKENER

000-FS-T-001

003

TO BULK CONCENTRATE THICKENER

C9

245-FS-T-002

M

COPPER CLEANER SCAVENGER FEED PUMPBOX

004

TO FILTER PLANT M M

1st MOLY CLEANER CELLS (4)

COPPER CONCENTRATE THICKENER OVERFLOW PUMPBOX

C8

C7

M

M M

M M

000-FS-T-002

DRAWING No.

000-FS-T-001

C13 C12 COPPER REGRIND MILL CYCLONES FEED PUMPBOX

COPPER CLEANER SCAVENGER TAILS PUMPBOX 000-FS-T-001

2nd MOLY CLEANER CELLS (3)

005

TO TRANSFER BOX OF PLANT TAILINGS THICKENER

M

000-FS-T-001

006

M TO BULK CONCENTRATE THICKENER

M 1st MOLY CLEANER TAILS PUMPBOX

MOLY REGRIND MILL CYCLONE CLUSTER CYCLONE (5)

4th MOLY CLEANER COLUMNS CELLS

3rd MOLY CLEANER COLUMNS CELLS

MOLY REGRIND MILL

MOLY CONCENTRATE THICKENER OVERFLOW PUMPBOX

M

BY VENDOR 000-FS-T-001

007

TO BULK CONCENTRATE THICKENER MOLY CONCENTRATE THICKENER 3rd MOLY CLEANER FEED PUMPBOX

2nd MOLY CLEANER TAILS PUMPBOX

4th MOLY CLEANER FEED PUMPBOX 280-FS-T-002

008

TO STORAGE TANK MOLY CLEANER-SCAVENGER FEED PUMPBOX M M

MOLY CLEANER SCAVENGER FLOTATION CELLS (4) M

000-FS-T-001 M

009

TO PLANT TAILINGS THICKENER

KNIFE GATE VALVE

LEGEND: PRIMARY FLOW LIQUID

SECONDARY FLOW LIQUID

CONSUMABLES INTERMITTENT OR ALTERNATE FLOW DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL QUALITY CONTROL

DISCIPLINE MANAGER NAME

MOLY CLEANER-SCAVENGER TAILS PUMPBOX

THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN

T I T L E

MOLY REGRIND MILL CYCLONES FEED PUMPBOX

SIGN & STAMP

NAME

R E V I S I O N S

R E F E R E N C E S DWG. NO.

SIGN

DOCUMENT CONTROL

NO.

D E S C R I P T I O N

BY

SCALE:

R E V I S I O N S CHECK

APPROVED

DATE

NO.

D E S C R I P T I O N

BY

CHECK

APPROVED

DATE

PROJECT

SHEET SIZE

TOROMOCHO PROJECT

A1

NOTICE

AREA THIS IS A COMPUTER GENERATED DRAWING. ALL CHANGES HERE TO SHALL BE PERFORMED USING CADD ONLY.

DRAWN BY:

A.P.

DATE:

18/02/09 TITLE

THIS DRAWING IS THE PROPERTY OF AND EMBODIES PROPRIETARY INFORMATION BELONGING TO AKER SOLUTIONS AND MUST BE RETURNED IMMEDIATELY UPON

CHECKED BY:

H.A.

DATE:

18/02/09

APPROVED BY:

P.Z.

DATE:

19/02/09

AUTHORIZED BY:

A.F.

DATE:

18/02/09

REQUEST. IT MUST NOT BE COPIED IN WHOLE OR IN

0

APPROVED FOR CONSTRUCTION

A.P.

H.A.

P.Z.

A.F.

19/02/09

PART, NOR THE INFORMATION SHOWN THERE ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE WRITTEN PERMISSION.

000-FS-T-002

OVERALL FLOW DIAGRAM SHEET 2 OF 2 (BASIC ENG.)

H

ISSUED FOR CLIENT APPROVAL

A.P.

H.A.

P.Z.

A.F.

03/02/09

G

RE-ISSUED FOR INTERNAL COORDINATION

A.P.

J.C.

P.Z.

A.F.

14/11/08

F

ISSUED FOR DESIGN (BASIC ENG.)

P.V.

P.M.

G.R.

19/09/08

MINERA CHINALCO PERU S.A. MCP APPROVED:

DATE:

User:

csc3427

19-02-2009

15:29:15

000 - GENERAL

OVERALL PROCESS FLOW DIAGRAM SHEET 2 OF 2

P:\SCL_04_Eng_Dwg\03_Pro\04_Final\000-FS-T-002_0.dgn

C-560

REVISION

CAD NO.

000-FS-T-002_0.dgn DWG. NO.

000-FS-T-002

0