Capacidad Portante de Un Suelo

CAPACIDAD PORTANTE DE UN SUELO MNT + 0.00 DF NFC B DF B 2.75 2 �_� FACTOR DE SEGURIDAD 1.75 gr/cm3 γ 1.75 ton/m3

Views 177 Downloads 5 File size 3MB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

Citation preview

CAPACIDAD PORTANTE DE UN SUELO

MNT + 0.00

DF

NFC B

DF B

2.75 2

�_�

FACTOR DE SEGURIDAD 1.75 gr/cm3 γ 1.75 ton/m3

DATOS DE ENSAYO COHESION 0.12 ANGULO DE FRICCION 31.4

HALLANDO EL FACTOR DE CARGA NC, NQ, N‫ﻻ‬ SEGÚN LA TABLA 01 FACTOR DE CAPACIDAD DE CARGA ɸ 31 31.4 32

NC 32.67 33.80 35.49

NQ 20.63 21.65 23.18

HALLAR EL NC POR INTERPOLACION NC

33.80

HALLAR EL NQ POR INTERPOLACION NQ

21.65

N‫ﻻ‬ 25.99 27.68 30.22

HALLAR EL N‫ ﻻ‬POR INTERPOLACION N‫ﻻ‬

27.68

CALCULO DE CAPACIDA DE CARGA PARA UNA ZAPATA CORRIDA qc = CNC + ƔDF Nq + 1/2 Ɣ B Nɣ qc

Qadm

156.69 15.67 TON/M2 KG/CM2 CARGA ADMICIBLE 5.22 kg/cm2

PARA UNA ZAPATA CUADRADA qc = 1.3CNC + ƔDF Nq + 0.4 Ɣ B Nɣ qc

Qadm

148.22 14.82 TON/M2 KG/CM2 CARGA ADMICIBLE 4.94 kg/cm2

PARA UNA ZAPATA CIRCULAR qc = 1.3CNC + ƔDF Nq + 0.6Ɣ B Nɣ qc

Qadm

167.595313 16.7595313 TON/M2 KG/CM2 CARGA ADMICIBLE 5.58651043 kg/cm2

"Escriba aquí la ecuación." TABLA 01

ENSAYO KG/CM2

Consideraciones de anchos mínimos y Df en calculo capcidad de portante d e zaptas D f mínimo recomendable 1.20 m Anchos mínimo recomendable 1.20 m edificios hasta 4 pisos Anchos mínimo recomendable 1.50 a 2.00 m edificios mayores 4 pisos NFZ - 1.20