2013 Product Catalog Advanced Controls & Drives Effective April 1, 2013 Medium Voltage Variable Frequency Drives SECTI
Views 483 Downloads 107 File size 9MB
2013 Product Catalog Advanced Controls & Drives Effective April 1, 2013
Medium Voltage Variable Frequency Drives
SECTION 1
Low Voltage Variable Frequency Drives
SECTION 2
Medium Voltage Starters
SECTION 3 SECTION 4
Low Voltage Starters
http://benshaw.cwfc.com
24/7/365 Service and Support Field Services
• Installations & commissioning • On-site repairs - Scheduled/emergency • On-site retrofits and upgrades
Factory Services
• Send-in repairs - Scheduled/emergency • Send-in retrofits and upgrades • Quick ship modified — Benshaw Express stock • Benshaw and 3rd party
Technical Training
• In-class in our training center • In-class at your facility • Customized for your business
Maintenance Services
• Thermography • Service contracts • Preventive - Maintenance / agreements • Power quality
Spare Parts
• 24/7/365 availability • Emergency delivery - Courier available • Replace or repair
Technology Retrofits
• Solid state motor controls and drives • Electromechanical motor controls • Orphaned OEM equipment retrofits
Medium Voltage Variable Frequency Drives Engineered Medium Voltage Drive Products M2L 3000 Series.......................................................2
To order WEB STOCKED items: visit www.BenshawExpress.com
1-1
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP
Introducing ... With over 20 years of medium voltage motor controls experience, Benshaw is now introducing a new family of medium voltage drives. Our medium voltage drive features a unique technology that allows Benshaw to offer a simple, compact, and reliable drive solution. Our innovative topology, coupled with an advanced control architecture, will enable customers to transform the way they do business. The M2L 3000 Medium Voltage Variable Frequency Drive is a step change in motor control power technology. Though designed for industrial applications, it benefits from Curtiss-Wright’s wide ranging experience in defense and nuclear-related technologies, an arena where products must meet the most rigorous standards and where failure is simply not an option. Our innovative patented topology — modular multilevel converter (M2LC) — is powered by state-of-the-art hardware and software controls. Our control algorithms are setting the stage for the next generation of VFDs.
Key Features: Compact Modular Design Simplistic component arrangement with minimal total part count
Installation Flexibility Optimal for retrofits
Arc Resistant Safety by design — arc flash footprint inherently lower
Energy Efficiency Inverter efficiency ≥99.5%
XCS Converter
M2L Inverter
Developed, designed, and manufactured in the USA. Supported around the globe.
Robust Control Architecture High performance, reliability and immunity from EMI, through noise tolerant signaling & fiber optic communications
1-2
To learn more about the M2L 3000, visit http://benshaw.cwfc.com, call 412-968-0100 or e-mail [email protected].
To order: call 412-968-0100
Engineered Medium Voltage Drive Products
Variable Frequency Drives
m2l 3000 series FRAME SIZES / weights / model number assembler - overview Converter Frame Sizes Frame
Model Number Assembler - Overview
Dimensions (in.) H
W
D
Weight (lbs.)
1
66 64 40 6200
2
91 76 44 9200
3
* *
*
Supply Voltage
*
Choose:
Disconnect Option
Inverter Frame Sizes Frame
Page 1-17
Dimensions (in.) H
W
D
Weight (lbs.)
1
66 61 40 1452
2
74 71 40 1500
3
* *
*
*
* = Consult factory
Choose:
Choose:
Supply Voltage Supply Frequency Motor Current
Uptime Option
Page 1-4
Page 1-17
Choose:
XCS Converter
M2L Inverter
M
Converter front
Converter side
To order WEB STOCKED items: visit www.BenshawExpress.com
Inverter front
Motor Voltage Motor Current Page 1-5
Motor
Inverter side
1-3
Engineered Medium Voltage Drive Products
Variable Frequency Drives
m2l 3000 series model number assembler - converter section Example Part Number:
XCS-3
4
6
4
0140
Options**
Series: XCS-3 = M2L-3000 Converter Input Voltage: 1 = 480 2 = 2400 3 = 3300 4 = 4160 5 = 4800 6 = 6600 7 = 6900 8 = 8320 A = 10000 B = 11000 C = 12000 D = 12470 E = 13200 F = 13800 Z = Other (specify at time of ordering) Input Freqency: 5 = 50 Hz 6 = 60 Hz Motor / Inverter Output Voltage: (Must match M2L-3 Output Voltage code) 2 = 2300 3 = 3300 4 = 4160 5 = 4800 * 6 = 6600 7 = 6900 8 = 8320 * A = 10000 * B = 11000 * C = 12000 * D = 12470 * E = 13200 * F = 13800 * Z = Other (specify at time of ordering) Inverter Output Rated Current (Total): 0035 = 35 amps 0070 = 70 amps 0100 = 100 amps 0140 = 140 amps 0190 = 190 amps 0260 = 260 amps 0300 = 300 amps 0440 = 440 amps 0550 = 550 amps 0880 = 880 amps * 1200 = 1200 amps * Blank = Standard / Base Unit OP = Options selected. For Option choices see page 12. * = Consult factory
1-4
To order: call 412-968-0100
Engineered Medium Voltage Drive Products
Variable Frequency Drives
m2l 3000 series model number assembler - inverter section Example Part Number:
M2L-3
X
6
4
0140
Options**
Series: M2L-3 = M2L-3000 Inverter Section Input Supply: X = with XCS Transformer Converter Section D = DC Bus Supply (Inverter only), Consult factory for voltage specifications Motor / Output Base Freqency: 5 = 50 Hz 6 = 60 Hz Motor / Inverter Output Voltage: (Must match XCS-3 Output Voltage code, when XCS is supplied) 2 = 2300 3 = 3300 4 = 4160 5 = 4800 * 6 = 6600 7 = 6900 8 = 8320 * A = 10000 * B = 11000 * C = 12000 * D = 12470 * E = 13200 * F = 13800 * Z = Other (specify at time of ordering) Inverter Output Rated Current: 0035 = 35 amps 0070 = 70 amps 0100 = 100 amps 0140 = 140 amps 0190 = 190 amps 0260 = 260 amps 0300 = 300 amps 0440 = 440 amps 0550 = 550 amps 0880 = 880 amps * 1200 = 1200 amps * Blank = Standard / Base Unit OP = Options selected. For Option choices see page 12. * = Consult factory
To order WEB STOCKED items: visit www.BenshawExpress.com
1-5
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 2.3 kV Converter Input & Output 60 Hz
Cell Current
Dimensions (in.)
Weight (lbs.)
Model Number
HP
XCS-32620140
500
140
1
66 64 40 6200
XCS-32620140
600
140
1
66 64 40 6200
XCS-32620190
700
190
2
91 76 44 9200
XCS-32620190
800
190
2
91 76 44 9200
XCS-32620260
900
260
2
91 76 44 9200
XCS-32620260
1000
260
2
91 76 44 9200
XCS-32620300
1250
300
2
91 76 44 9200
XCS-32620440
1500 440 3 *
*
*
*
XCS-32620440
1750 440 3 *
*
*
*
XCS-32620440
2000 440 3 *
*
*
*
XCS-32620550
2250 550 3 *
*
*
*
XCS-32620550
2500 550 3 *
*
*
*
XCS-32620880
3000 880 3 *
*
*
*
XCS-32620880
3500 880 3 *
*
*
*
Frame
H
W
D
* = Consult factory
1-6
To order: call 412-968-0100
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 2.3 kV Inverter Input & Output 60 Hz
Cell Current
Dimensions (in.)
Weight (lbs.)
Model Number
HP
M2L-3X620140
500
140
1
66 61 40 1452
M2L-3X620140
600
140
1
66 61 40 1452
M2L-3X620190
700
190
2
74 71 40 1500
M2L-3X620190
800
190
2
74 71 40 1500
M2L-3X620260
900
260
2
74 71 40 1500
M2L-3X620260
1000
260
2
74 71 40 1500
M2L-3X620300
1250
300
2
74 71 40 1500
M2L-3X620440
1500 440 3 * *
*
*
M2L-3X620440
1750 440 3 * *
*
*
M2L-3X620440
2000 440 3 *
*
*
*
M2L-3X620550
2250 550 3 *
*
*
*
M2L-3X620550
2500 550 3 *
*
*
*
M2L-3X620880
3000 880 3 *
*
*
*
M2L-3X620880
3500 880 3 *
*
*
*
Frame
H
W
D
* = Consult factory
To order WEB STOCKED items: visit www.BenshawExpress.com
1-7
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 3.3 kV Converter Input & Output 60 Hz
Cell Current
Dimensions (in.)
Weight (lbs.)
Model Number
HP
XCS-33630100
500
100
1
66 64 40 6200
XCS-33630100
600
100
1
66 64 40 6200
XCS-33630140
700
140
1
66 64 40 6200
XCS-33630140
800
140
1
66 64 40 6200
XCS-33630190
900
190
2
91 76 44 9200
XCS-33630190
1000
190
2
91 76 44 9200
XCS-33630260
1250
260
2
91 76 44 9200
XCS-33630260
1500
260
2
91 76 44 9200
XCS-33630300
1750
300
2
91 76 44 9200
XCS-33630440
2000 440 3 *
*
*
*
XCS-33630440
2250 440 3 *
*
*
*
XCS-33630440
2500 440 3 *
*
*
*
XCS-33630550
3000 550 3 *
*
*
*
XCS-33630550
3500 550 3 *
*
*
*
XCS-33630880
4000 880 3 *
*
*
*
XCS-33630880
4500 880 3 *
*
*
*
XCS-33630880
5000 880 3 *
*
*
*
Frame
H
W
D
* = Consult factory
1-8
To order: call 412-968-0100
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 3.3 kV Inverter Input & Output 60 Hz
Cell Current
Dimensions (in.)
Weight (lbs.)
Model Number
HP
M2L-3X630100
500
100
1
66 61 40 1452
M2L-3X630100
600
100
1
66 61 40 1452
M2L-3X630140
700
140
1
66 61 40 1452
M2L-3X630140
800
140
1
66 61 40 1452
M2L-3X630190
900
190
2
74 71 40 1500
M2L-3X630190
1000
190
2
74 71 40 1500
M2L-3X630260
1250
260
2
74 71 40 1500
M2L-3X630260
1500
260
2
74 71 40 1500
M2L-3X630300
1750
300
2
74 71 40 1500
M2L-3X630440
2000 440 3 *
*
*
*
M2L-3X630440
2250 440 3 *
*
*
*
M2L-3X630440
2500 440 3 *
*
*
*
M2L-3X630550
3000 550 3 *
*
*
*
M2L-3X630550
3500 550 3 *
*
*
*
M2L-3X630880
4000 880 3 *
*
*
*
M2L-3X630880
4500 880 3 *
*
*
*
M2L-3X630880
5000 880 3 *
*
*
*
Frame
H
W
D
* = Consult factory
To order WEB STOCKED items: visit www.BenshawExpress.com
1-9
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 4.2 kV Converter Input & Output 60 Hz
Cell Current
Dimensions (in.)
Weight (lbs.)
Model Number
HP
XCS-34640070
500
70
1
66 64 40 6200
XCS-34640100
600
100
1
66 64 40 6200
XCS-34640100
700
100
1
66 64 40 6200
XCS-34640140
800
140
1
66 64 40 6200
XCS-34640140
900
140
2
66 64 40 6200
XCS-34640140
1000
140
2
66 64 40 6200
XCS-34640190
1250
190
2
91 76 44 9200
XCS-34640190
1500
190
2
91 76 44 9200
XCS-34640260
1750
260
2
91 76 44 9200
XCS-34640260
2000
260
3
91 76 44 9200
XCS-34640300
2250
300
3
91 76 44 9200
XCS-34640440
2500 440 3 *
*
*
*
XCS-34640440
3000 440 3 *
*
*
*
XCS-34640440
3500 440 3 *
*
*
*
XCS-34640550
4000 550 3 *
*
*
*
XCS-34640880
4500 880 3 *
*
*
*
XCS-34640880
5000 880 3 *
*
*
*
XCS-34640880
5500 880 3 *
*
*
*
XCS-34640880
6000 880 3 *
*
*
*
Frame
H
W
D
* = Consult factory
1 - 10
To order: call 412-968-0100
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 4.2 kV Inverter Input & Output 60 Hz
Cell Current
Dimensions (in.)
Weight (lbs.)
Model Number
HP
M2L-3X640070
500
70
1
66 61 40 1452
M2L-3X640100
600
100
1
66 61 40 1452
M2L-3X640100
700
100
1
66 61 40 1452
M2L-3X640140
800
140
1
66 61 40 1452
M2L-3X640140
900
140
2
66 61 40 1452
M2L-3X640140
1000
140
2
66 61 40 1452
M2L-3X640190
1250
190
2
74 71 40 1500
M2L-3X640190
1500
190
2
74 71 40 1500
M2L-3X640260
1750
260
2
74 71 40 1500
M2L-3X640260
2000
260
3
74 71 40 1500
M2L-3X640300
2250
300
3
74 71 40 1500
M2L-3X640440
2500 440 3 *
*
*
*
M2L-3X640440
3000 440 3 *
*
*
*
M2L-3X640440
3500 440 3 *
*
*
*
M2L-3X640550
4000 550 3 *
*
*
*
M2L-3X640880
4500 880 3 *
*
*
*
M2L-3X640880
5000 880 3 *
*
*
*
M2L-3X640880
5500 880 3 *
*
*
*
M2L-3X640880
6000 880 3 *
*
*
*
Frame
H
W
D
* = Consult factory
To order WEB STOCKED items: visit www.BenshawExpress.com
1 - 11
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series options Certifications Catalog Number
Description
C01
UL Listing*
C02
CE Conformity*
C03
CSA Certification*
Fieldbus Commuications Catalog Number
Description
FBC01
Profibus DP
FBC02
Modbus TCP/IP
FBC03
Ethernet IP
FBC04
Device Net
Motor Control Catalog Number
Description
MC01
Four Quadrant Control*
MC02
Bidirectional Bumpless Transfer*
Control Accessories Catalog Number
Description
CA01
Pushbutton Control
CA02
Local - Off - Remote Selector
CA03
Hand - Off - Auto Selector
CA04
Keyed Local - Off - Remote Selector
CA05
Keyed Hand - Off - Auto Selector
Cooling Fan / Control Power Catalog Number
Description
TR01
2300/220 VAC 10 KVA
TR02
3300/220 VAC 10 KVA
TR03
4160/220 VAC 10 KVA
TR04
6600/220 VAC 10 KVA
TR05
6900/220 VAC 10 KVA
* = Consult factory
1 - 12
To order: call 412-968-0100
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series options Disconnect Catalog Number
Description
CF01
400 Amp, Fused, 24” x 92”
CF02
1200 Amp Fused aa x bb
CF03 circuit breaker
Uptime Enhancement Catalog Number
Description
UE01
Solid State Cell Bypass*
UE02
redundant fans*
UE03
Medium voltage reduce voltage starter bypass
UE04
ATL starter bypass
Drive Interface Catalog Number
Description
HMI01
11 inch touch pad HMI
HMI02
Smart Device (ipad)*
* = Consult factory
To order WEB STOCKED items: visit www.BenshawExpress.com
1 - 13
Engineered Medium Voltage Drive Products
Variable Frequency Drives m2l 3000 series connection diagram
*
* Customer Supplied
1 - 14
To order: call 412-968-0100
Low Voltage Variable Frequency Drives Standard Low Voltage Drive Products General Purpose Micro Drives..................................2 Sensorless Vector Drives..........................................5 Built-To-Order Packaged Drives.............................10 NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives........................................15
Standard Low Voltage Drive Options Input Line Reactors.................................................21 Output Reactors......................................................27 Long Lead Filters....................................................29 Dynamic Brake Resistors and Brake Modules........32
Engineered Low Voltage Drive Products Sensorless Vector Drives........................................34 Clean Power Drives................................................35 Custom-engineered Drive Solutions.......................36
To order WEB STOCKED items: visit www.BenshawExpress.com
2-1
Standard Low Voltage Drive Products
General Purpose Micro Drives
gx series 1–5 hp, 230 / 460 v, nema 1 / protected chassis RATINGS Constant Torque: 1–5 HP @ 460 V 1–5 HP @ 230 V Chassis VFD converts to NEMA 1 with conduit kit
Product Highlights: The GX series is a compact, economical chassis drive designed for low horsepower applications. The GX series has a powerful set of parameters with a simple, easy to use keypad. The programming structure provides quick, simple setup. Although small in size, the GX series provides a large amount of digital I/O for custom applications.
Key Advantages:
Standard Features:
• Small, compact design
• Standard I/O: 8 digital inputs, 2 analog inputs, 1 analog output, 1 relay output, 1 open collector output
• Constant torque rated • Sensorless vector control or V/Hz control • Standard dynamic braking transistor • Flexible, programmable I/O • Integral PID control • Standard ModBus RTU port • Windows based software
• Digital metering: Output current, output frequency, DC link voltage, motor RPM, output power, output voltage, output torque • Protection: Over current, ground fault, over voltage, current limit, motor overload, output phase loss, over heat, loss of signal, and more • Communications: ModBus RTU (standard) • Voltage tolerance: ±10% • Control methods: Open loop V/Hz, sensorless vector control • V/Hz patterns: Linear, squared, user programmable V/Hz
• Analog inputs: 1 at 0/4 – 20 mA, 1 at 0 – 10 Vdc • Relay output and open collector output: 1 Form C relay output and 1 open collector output, programmable to running, faulted, stopped, ready, at speed, high or low frequency levels, loss of signal, and more • Digital inputs: 8 digital inputs configurable to forward run, reverse run, 3 wire start /stop, reset, jog, preset speeds, motorized pot function, external trip, alternate ramp selections, HOA, and more • User interface: 4 digit LED display • Stop methods: Coast, decel, DC injection braking, and optional dynamic braking
• Analog output functions: 1 analog output 0 – 10 Vdc. Configurable to motor speed, output current, output voltage, DC link voltage.
2-2
To order: call 412-968-0100
Standard Low Voltage Drive Products
General Purpose Micro Drives gx series control terminal layout
LED display
T/M
Description
MO
Multi-function open collector output
MG
MO common
24
24 V power supply (100 mA max.)
P1 P2
Multi-function input terminal (factory setting)
CM
Input signal common
P3 P4 P5 CM P6 P7 P8
RX: Reverse run
BX: Emergency stop Multi-function input terminal (factory setting)
RST: Trip reset
Input signal common Multi-step freq. — Low Multi-function input terminal (factory setting)
Multi-step freq. — Middle Multi-step freq. — High
V1
Freq. setting voltage signal input: -0 – 10 V
I
Freq. setting current signal input: 0 – 20 mA
AM
Multi-function analog output signal: 0 – 10 V
3A
S+ S–
Left/right up/down keys
JOG: Jog operation
10 V power supply for potentiometer
3C
Run/stop buttons
FX: Forward run
VR
3B
Status indicators
Save parameters
Normally open contact Multi-function relay output terminal
Normally closed contact Common
Programmable I/O
Modbus terminal
RS485 communication terminal
To order WEB STOCKED items: visit www.BenshawExpress.com
2-3
Standard Low Voltage Drive Products
General Purpose Micro Drives gx series protected chassis, 1–5 hp, 230 / 460 v 230 V Model Number
RSI-001-GX-2 • RSI-002-GX-2 • RSI-003-GX-2 • RSI-005-GX-2 •
Constant Torque HP
Variable Torque
Amps
HP
Amps
Dimensions (in.) H
W
D
Weight (lbs.)
1
4.2
-
-
5.0 2.8 5.1 2
2
6.8
-
-
5.0 3.9 5.1 3
3
9.6
-
-
5.0 5.5 6.1 4
5
15.2
-
-
5.0 5.5 6.1 5
460 V Model Number
RSI-001-GX-4 • RSI-002-GX-4 • RSI-003-GX-4 • RSI-005-GX-4 •
Constant Torque HP
Variable Torque
Amps
HP
Amps
Dimensions (in.) H
W
D
Weight (lbs.)
1
2.1
-
-
5.0 2.8 5.1 2
2
3.4
-
-
5.0 3.9 5.1 3
3
4.8
-
-
5.0 5.5 6.1 4
5
7.6
-
-
5.0 5.5 6.1 5
NEMA 1 CONDUIT KITS GX-NEMA1KIT-A GX-NEMA1KIT-B GX-NEMA1KIT-C
Conduit Kit For 1 HP GX Drive Conduit Kit For 2 HP GX Drive Conduit Kit For 3 HP AND 5 HP GX Drive
REMOTE KEYPAD VFD-2M-GX-KEYPAD
Remote Mount Keypad and 2 Meter Cable
Units are stocked as protected chassis. If NEMA 1 enclosed is required, add NEMA 1 conduit kit. Conduit kits will need to be installed by customer. Web stocked •
2-4
To order: call 412-968-0100
Standard Low Voltage Drive Products
Sensorless Vector Drives
sg series variable torque / standard duty / heavy duty RATINGS Variable Torque: 7.5–40 HP @ 230 V 7.5–700 HP @ 460 V 7.5–400 HP @ 600 V Standard Duty: 7.5–40 HP @ 230 V 7.5–600 HP @ 460 V 7.5–400 HP @ 600 V Heavy Duty: 5–30 HP @ 230 V 5–500 HP @ 460 V 5–300 HP @ 600 V
Highlights: The SG series is a compact, economical drive designed for the most demanding applications. The flexible power stack allows the user to apply it to heavy duty loads (150% for 60 secs), standard duty loads (120% for 60 secs), or variable torque loads (110% for 60 secs). With over 250 programmable parameters, Benshaw’s SG series drives are configurable to meet the needs of almost any industrial application, yet remain simple and easy to use.
Key Advantages: • Standard and heavy duty ratings • Integral PID Control • Sensorless vector control or V/Hz control • Integral multiple motor control for pumping applications • Uploadable / downloadable keypad • Flexible, programmable I/O • Economical, compact design • Simple, easy to use LCD interface • Standard ModBus RTU port • Windows-based software
Standard Features: • Standard I/O: 8 digital inputs, 2 analog inputs, 2 analog outputs, 5 relay outputs
• Communications: Modbus RTU (standard). Optional Fieldbus includes DeviceNet, Profibus, BacNet, LonWorks, Modbus TCP
• Optional I/O: Isolated analog output board (adds 2 additional analog outputs, 0/4 – 20 mA)
• Voltage tolerance: -15%, +10%
• Digital metering: Output currents, ground current, output frequency, DC link voltage, motor RPM, output motor voltage, run time, and more
• V/Hz patterns: Linear, squared, user programmable V/Hz
• Protection: Over current, ground fault, over voltage, current limit, motor overload, phase loss, over heat, loss of signal and more • Analog inputs: 1 at 0/4 – 20 mA, 1 at 0 – 10 Vdc (or -10 to 10 Vdc)
• Control methods: V/Hz, sensorless vector, slip compensation
• Analog outputs: 2 at 0 – 10 Vdc (standard), 2 at 0/4 – 20 mA (with option board). Configurable to motor speed, output current, output voltage, DC link voltage, power, PID follower
To order WEB STOCKED items: visit www.BenshawExpress.com
• Relay outputs: 1 Form C fault relay output, 4 Form A relay outputs configurable to running, faulted, ready, at speed, high or low frequency levels, loss of signal, ready, and more • Digital inputs: 8 digital inputs configurable to forward run, reverse run, 3 wire start / stop, reset, jog, preset speeds, motorized pot function, external trip, alternate ramp selections, HOA, and more • User interface: 2 line LCD display, 16 characters per line • Stop methods: Coast, decel, DC injection braking, Flux braking and optional dynamic braking
2-5
Standard Low Voltage Drive Products
Sensorless Vector Drives sg series basic wiring diagram
DB UNIT (option)
MCCB1
MC1
ACR
R S T G
3 Phase AC input
P1P2
24 VDC (50mA max)
24
Default: Speed-L
M1
Default: Speed-M
M2
Default: Speed-H
M3
Default: RST
M4
BX (E-STOP)
M5
Default: JOG
M6
Default: FX
M7
Default: RX
M8 CM
24G
CN1
Sourcing 24G Mode PNP Sinking 24P Mode NPN
M
W Motor
E
Safety stop (600V only)
V1
I
0[V]~+12[V]
Analog input
0/4[mA]~20[mA]
5G
24V 4.9mA
S0
Default: Frequency
Analog meter
S1
Default: Voltage
Max output voltage:12V Source max: 30mA Sink max: 20mA
5G 3A 3C 3B
C1 A2 C2 Aux. relays
A3
Fault relay output 250Vac, 1A
24G
C3
A0
A4
B0
C4
Pulse input method: (A+B), (A) Input freq: 0Hz~100KHz
Terminating resistor
C-
Pulse input
5G
24G
NT
C+ 24G
2-6
V
V1S -12[V]~+12[V]
A1
RS-485
U
U V W E/G
RSi-SG Setting Switch
Relay outputs programmable 250Vac, 1A
N
5G
Motor thermal detection
To order: call 412-968-0100
Standard Low Voltage Drive Products
Sensorless Vector Drives SG Series nema 1 230 V Model Number
RSI-007-SG-2B RSI-010-SG-2B RSI-015-SG-2B RSI-020-SG-2B RSI-025-SG-2B RSI-030-SG-2B RSI-040-SG-2B
Variable Torque HP
A
Standard Duty HP
A
Heavy Duty HP
A
Dimensions (in.) H
W
D
Weight (lbs.)
7.5 24 7.5 22 5 17 11.2 5.9 6.2 11 10 32 10 29 7.5 23 11.2 7.9 7.2 14 15 46 15 42 10 33 11.2 7.9 7.2 14 20 60 20 55 15 44 17.9 9.8 7.9 28 25 74 25 67 20 54 17.9 9.8 7.9 29 30 88 30 80 25 68 23.6 12 9.2 44 40 115 40 105 30 84 23.6 12 9.2 44
460 V Model Number
RSI-007-SG-4B RSI-010-SG-4B RSI-015-SG-4B RSI-020-SG-4B RSI-025-SG-4B RSI-030-SG-4B RSI-040-SG-4B RSI-050-SG-4B RSI-060-SG-4B RSI-075-SG-4B RSI-100-SG-4B RSI-125-SG-4B RSI-150-SG-4 • * RSI-200-SG-4 • * RSI-250-SG-4 • * RSI-350-SG-4 • * RSI-400-SG-4 • * RSI-500-SG-4 • RSI-600-SG-4 • RSI-700-SG-4 •
Variable Torque HP
A
Standard Duty HP
A
Heavy Duty HP
A
Dimensions (in.) H
W
D
Weight (lbs.)
7.5 12 7.5 11 5 8 11.2 5.9 6.2 11 10 16 10 14 7.5 11 11.2 7.9 7.2 14 15 24 15 22 10 17 11.2 7.9 7.2 14 20 30 20 27 15 22 17.9 9.8 7.9 28 25 39 25 35 20 28 17.9 9.8 7.9 29 30 45 30 41 25 34 23.6 12 9.2 44 40 61 40 55 30 44 23.6 12 9.2 44 50 75 50 68 40 55 25.3 12.1 10.5 60 60 91 60 83 50 66 25.3 12.1 10.5 60 75 110 75 100 60 80 25.3 12.1 11.2 64 100 152 100 139 75 111 30.2 14.5 12.1 95 125 183 125 167 100 134 30.2 14.5 12.1 95 150 223 150 204 125 164 30.9 20.1 16.6 225 200 264 200 242 150 194 30.9 20.1 16.6 225 250 325 250 302 200 240 33.9 20.1 16.6 255 350 432 300 396 250 317 42.5 27.2 17.3 450 400 547 400 501 300 401 42.5 27.2 17.3 450 500 613 450 562 350 450 44.9 30.8 17.4 540 600 731 500 670 400 536 51.3 36.3 19.5 840 700 877 600 804 500 643 51.3 36.3 19.5 840
Variable Torque = 110% current for 1 minute / Standard Duty = 120% current for 1 minute / Heavy Duty = 150% current for 1 minute Units ending in a “B” designate NEMA 1. Units not ending in a “B” are protected chassis units. •
Protected chassis only (power terminal covers do not meet NEMA 1).
*
DC Link Reactor (internal)
Web stocked To order WEB STOCKED items: visit www.BenshawExpress.com
2-7
Standard Low Voltage Drive Products
Sensorless Vector Drives sg series nema 1 / protected chassis 600 V Model Number
RSI-007-SG-6B RSI-010-SG-6B RSI-015-SG-6B RSI-020-SG-6B RSI-025-SG-6B RSI-030-SG-6B RSI-040-SG-6B RSI-050-SG-6B RSI-060-SG-6B RSI-075-SG-6B RSI-100-SG-6B RSI-125-SG-6B RSI-150-SG-6 • * RSI-200-SG-6 • * RSI-250-SG-6 • * RSI-350-SG-6 • * RSI-400-SG-6 • *
Variable Torque HP
A
Standard Duty HP
A
Heavy Duty HP
A
Dimensions (in.) H
W
D
Weight (lbs.)
7.5 9 7.5 8.2 5 6.6 14 7.9 7.2 15 10 12 10 11 7.5 9 14 7.9 7.2 16 15 17 15 15.5 10 12 14 7.9 7.2 16 20 23 20 21 15 17 17.9 9.8 7.9 28 25 27 25 24.7 20 19.8 17.9 9.8 7.9 29 30 34 30 31 25 25 23.6 12 9.2 44 40 43 40 39 30 31.5 23.6 12 9.2 44 50 55 50 50 40 43 25.3 11.8 11.5 71 60 64 60 58.6 50 55 25.3 11.8 11.5 71 75 80 75 73 60 64 25.3 11.8 11.5 71 100 104 100 95 75 80 30.2 14.6 13.3 102 125 128 125 117 100 104 30.2 14.6 13.3 102 150 150 150 137 125 128 30.9 20 16.6 225 200 200 200 184 150 147 33.9 20 16.6 255 250 242 250 222 150 177 33.9 20 16.6 255 350 333 300 305 250 244 42.5 27.2 17.7 450 400 424 400 389 300 311 42.5 27.2 17.7 450
Variable Torque = 110% current for 1 minute / Standard Duty = 120% current for 1 minute / Heavy Duty = 150% current for 1 minute Units ending in a “B” designate NEMA 1. Units not ending in a “B” are protected chassis units. •
Protected chassis only (power terminal covers do not meet NEMA 1).
*
DC Link Reactor
Web stocked
2-8
To order: call 412-968-0100
Standard Low Voltage Drive Products
Sensorless Vector Drives sg series options Dynamic Brake Transistor Modules Catalog Number
Description
VFD-RSI-DBU-020-2
230V Dynamic braking transistor for 1 – 20 HP VFD, 10% duty cycle
VFD-RSI-DBU-030-2
230V Dynamic braking transistor for 25 – 30 HP VFD, 10% duty cycle
VFD-RSI-DBU-050-2
230V Dynamic braking transistor for 40 – 50 HP VFD, 10% duty cycle
VFD-RSI-DBU-020-4
460V Dynamic braking transistor for 1 – 20 HP VFD, 10% duty cycle
VFD-RSI-DBU-030-4
460V Dynamic braking transistor for 25 – 30 HP VFD, 10% duty cycle
VFD-RSI-DBU-050-4
460V Dynamic braking transistor for 40 – 50 HP VFD, 10% duty cycle
VFD-RSI-DBU-075-4
460V Dynamic braking transistor for 60 – 75 HP VFD, 10% duty cycle
VFD-RSI-DBU-100-4
460V Dynamic braking transistor for 100 HP VFD, 10% duty cycle
• For HP greater than 100 HP or duty cycle greater than 10%, consult factory.
Fieldbus Communication Cards Catalog Number
Description
PC-400001-00 Devicenet communication board kit, SG VFD PC-400002-00
Profibus communication board kit, SG VFD
PC-400003-00
LonWorks communication board kit, SG VFD
PC-400004-00
BacNet communication board kit, SG VFD
PC-400005-00
Modbus TCP communication board kit, SG VFD
Display / Keypad Remote Mounting Catalog Number
Description
LCD-100000-00
Replacement display/keypad
VFD-2M-RE-CABLE-SG
2 Meter keypad cable
VFD-3M-RE-CABLE-SG
3 Meter keypad cable
VFD-5M-RE-CABLE-SG
5 Meter keypad cable
VFD-KEYPAD-SG-BEZEL
Bezel, for SG keypad, remote mounting
VFD-KEYPAD-SG-BLANK
Keypad blank, installs in drive when keypad is remote
Analog Output Card Catalog Number
Description
VFD-RSI-SG-4-20-MA
4 - 20 mA Output card, adds (2) 4-20 mA outputs
To order WEB STOCKED items: visit www.BenshawExpress.com
2-9
Built-To-Order, 2 Week Shipment
Packaged Drives
SGP Series standard duty / heavy duty SG Series sensorless vector drive
RATINGS Standard Duty: 7.5–40 HP @ 230 V 7.5–125 HP @ 460 V Heavy Duty: 5–30 HP @ 230 V 5–100 HP @ 460 V
Control power transformer
Input circuit breaker and disconnect
User terminal strip
Bypass contactor
Highlights:
NEMA 12 ventilated enclosure
Benshaw’s Built-To-Order packaged drives meet UL and CE approvals and are available with standard (7.5–125 HP) and heavy duty (5–100 HP) ratings to meet your drive requirements.
Key Advantages:
Standard Features:
Options:
• Standard and heavy duty ratings
• Circuit breaker
• UL and CE approvals
• NEMA 12 ventilated enclosure with fans and filters
• Pre-designed options configurable to your application
• SG Series Sensorless Vector Drive • User terminal strip
• Input line reactor
OPERATING CONDITIONS Operating Temperature: -10–40°C Storage Temperature: -20°C–65°C Humidity: Less than 90% RH max (non-condensing) Altitude: 3,300 ft. max.
2 - 10
• Door mounted keypad • Control power transformer • User input and output power connections
• Disconnect fused or unfused • Output reactor • 3 contactor bypass • Door mounted operator station (6 configurations)
• -10°–40° C operating environment temperature range • -20°–65° C storage temperature
To order: call 412-968-0100
Built-To-Order, 2 Week Shipment
Packaged Drives
SGP Series part number assembler
SGP 005
2
SD
NC
A
3B
1
12
SG Built-To-Order Packaged Drives
Enclosure
Horsepower
Door Mounted Devices
005 = 5 HP
1 = None
007 = 7.5 HP
2 = Start/stop PB, reset PB, HOA switch, speed pot
010 = 10 HP 015 = 15 HP 020 = 20 HP 025 = 25 HP 030 = 30 HP 040 = 40 HP 050 = 50 HP 060 = 60 HP 075 = 75 HP 125 = 125 HP
12 = NEMA 12 V
3 = Option 2 plus power ON, VFD running, VFD fault light 4 = Start/stop PB, fault reset PB, HOA switch, speed pot, jog PB, fwd/rev switch, VFD fault light 5 = VFD/Off/bypass switch, bypass running light 6 = Start/stop PB, reset PB, HOA switch, speed pot, VFD running light, VFD/off/bypass switch, bypass running light
Voltage 2 = 230 V 4 = 460 V
Bypass Type NN = None 3B = 3 Contactor bypass
Duty Type SD = 120% 1 min std duty
Reactor Options
HD = 150% 1 min heavy duty
A = No reactors B = Input reactor
Disconnect Option
C = Output reactor
NC = Non-combination
D = Input and output reactor
CB = Circuit breaker FD = Fusible disconnect CF = Non-fused disconnect IF = Inline fuse
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 11
Built-To-Order, 2 Week Shipment
Packaged Drives
SGP Series standard duty rated 120% O/L for 1 minute 230 Vac, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated Model Number
HP
Dimensions (in.)
A
H
W
D
Weight (lbs.)
SGP0072SDXXXXXX12
7.5
22 30 24 16 90
SGP0102SDXXXXXX12
10
28 30 24 16 93
SGP0152SDXXXXXX12
15
42 36 30 16 99
SGP0202SDXXXXXX12
20
54 36 30 16 104
SGP0252SDXXXXXX12
25
68 36 30 16 110
SGP0302SDXXXXXX12
30
80 36 30 16 148
SGP0402SDXXXXXX12
40
104 36 30 16 158
460 Vac, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated Model Number
HP
Dimensions (in.)
A
H
W
D
Weight (lbs.)
SGP0074SDXXXXXX12
7.5
11 30 24 16 90
SGP0104SDXXXXXX12
10
14 30 24 16 93
SGP0154SDXXXXXX12
15
21 30 24 16 99
SGP0204SDXXXXXX12
20
27 30 24 16 104
SGP0254SDXXXXXX12
25
34 30 24 16 110
SGP0304SDXXXXXX12
30
40 36 30 16 148
SGP0404SDXXXXXX12
40
52 36 30 16 158
SGP0504SDXXXXXX12
50
65 36 30 16 174
SGP0604SDXXXXXX12
60
77 36 30 16 174
SGP0754SDXXXXXX12
75
96 36 30 16 178
SGP1004SDXXXXXX12 *
100
125
46
30
16
259
SGP1254SDXXXXXX12 *
125
156
46
30
16
259
*
Dimensions will increase to 70x30x18 for units with three contactor bypass.
•
Refer to page 2-11 for Disconnect Options, Reactor Options, Bypass Type, and Door Mounting Devices
2 - 12
To order: call 412-968-0100
Built-To-Order, 2 Week Shipment
Packaged Drives
SGP Series heavy duty rated 150% O/L for 1 minute 230 Vac, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated Model Number
HP
SGP0052HDXXXXXX12
5
A
Dimensions (in.) H
W
D
Weight (lbs.)
17 30 24 16 90
SGP0072HDXXXXXX12
7.5
23 30 24 16 90
SGP0102HDXXXXXX12
10
33 30 24 16 93
SGP0152HDXXXXXX12
15
44 36 30 16 99
SGP0202HDXXXXXX12
20
54 36 30 16 104
SGP0252HDXXXXXX12
25
68 36 30 16 110
SGP0302HDXXXXXX12
30
84 36 30 16 148
460 Vac, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated Model Number
HP
SGP0054HDXXXXXX12
5
SGP0074HDXXXXXX12
7.5
A 8
Dimensions (in.) H
W
D
Weight (lbs.)
30 24 16 90
11 30 24 16 90
SGP0104HDXXXXXX12
10
14 30 24 16 93
SGP0154HDXXXXXX12
15
21 30 24 16 99
SGP0204HDXXXXXX12
20
27 30 24 16 104
SGP0254HDXXXXXX12
25
34 36 30 16 110
SGP0304HDXXXXXX12
30
40 36 30 16 148
SGP0404HDXXXXXX12
40
52 36 30 16 158
SGP0504HDXXXXXX12
50
65 36 30 16 174
SGP0604HDXXXXXX12
60
77 36 30 16 174
SGP0754HDXXXXXX12 *
75
96
46
30
16
178
SGP1004HDXXXXXX12 *
100
125
46
30
16
259
*
Dimensions will increase to 70x30x18 for units with three contactor bypass.
•
Refer to page 2-11 for Disconnect Options, Reactor Options, Bypass Type, and Door Mounting Devices
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 13
Built-To-Order, 2 Week Shipment
Packaged Drives
SGP Series modular control options Options
CO1 CO2 CO3 CO4 CO5 CO6
Keypad
•
•
•
•
•
•
Start PB
•
•
•
•
Stop PB
•
•
•
•
Reset PB
•
•
•
•
HOA Switch
•
•
•
•
Speed POT
•
•
•
•
Run Light
•
•
Fault Light
•
•
Power On Light
•
Jog PB
•
FWD/REV Switch
•
VFD/OFF Bypass Switch
•
•
Bypass Running Light
•
•
•
If selecting a unit with bypass, you must select either option 5 or 6.
•
Door mounted keypad is standard.
2 - 14
To order: call 412-968-0100
Standard Low Voltage Drive Products
NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series standard duty / heavy duty RATINGS Constant Torque: 1 HP @ 115 V 1–20 HP @ 230 V 1–200 HP @ 460 / 600 V
Highlights: The S4 Series is a line of high performance NEMA 4X washdown / NEMA 12 variable frequency drives. Benshaw’s S4 variable frequency drives are built to withstand the harshest environments and hold up under your most demanding pressure washing applications. All S4 Series drives combine a simple user interface with an array of features and are suited to almost any indoor environment. S4 variable frequency drives come standard with over 180 configurable parameters to match specific application and interface requirements. A standard dynamic braking transistor and resistor are also included for regenerative applications.
Key Advantages: • NEMA 4X IP66 washdown duty enclosure* • Standard braking transistor and resistor • Sensorless vector control • Standard and Heavy Duty ratings • LCD plain English display • Simple, easy-to-use interface • Standard ModBus communication port • Integral PI control
Standard Features: • NEMA 4X IP66 washdown enclosure*
• Control methods: V/Hz, sensorless vector, slip compensation
• Standard I/O: 10 digital inputs, 2 analog inputs, 2 analog outputs, 2 relay outputs, 2 open collector outputs, 1 pulsed output
• V/Hz pattern: Linear, fan and pump, 2-step
• Digital metering: Output current, output voltage, power, MWh meter, run time, power on time, bus voltage, output frequency, and more • Communications: ModBus RTU (standard) • Voltage tolerance: ±10%
• Analog output functions: 1 at 0 – 10 Vdc, 1 at 0 /4-20 mA. Configurable to motor speed, output current, output voltage, DC link voltage, output power, output torque, PID • Analog inputs: 0 – 10 Vdc, 0/4-20 mA, –10 Vdc to 10 Vdc, pulse train input
• Relay outputs: Running, forward, reverse, ready, faulted, at speed, keypad control, adjustable torque levels, adjustable current levels, PID limits, loss of reference, timers • Digital inputs: 10 digital inputs. configurable to run, preset speeds, jogging, PID disable, fault reset, drive enable, timers, motorized pot, and more • User interface: 2 line LCD display, 16 characters per line • Braking functions: Decel, coast, DC injection, dynamic braking (internal IGBT and resistor) * Units 1–100 HP are NEMA 4X. Units 125–200 HP are NEMA 12.
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 15
Standard Low Voltage Drive Products
NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series basic wiring diagram
+24 Vdc
+24
NC2
Forward Run
FWD
RC2
Reverse Run
REV
NO2
Jog
R/J
NC1
Digital Input #1
DI1
RC1
Digital Input #2
DI2
NO1
Digital Input #3
DI3
DO1
Digital Output #1
Digital Input #4
DI4
DO2
Digital Output #2
Digital Input #5
DI5
DOQ
Pulse Train Output
MOL
dcom
Common
EN
dcom
Common
dcom
Imet
4 – 20 mA output
cin+
acom
Analog Common
cin-
Vmet
0 – 10 Vdc Output
+10
acom
Analog Common
External Fault
Enable
Relay #2
Relay #1
4 – 20 mA input
0 – 10 Vdc Input
Vin1
acom
0 – 10 Vdc Input
2 - 16
Vin2
To order: call 412-968-0100
Standard Low Voltage Drive Products
NEMA 4X Washdown Sensorless Vector Drives s4 series
230 V Model Number
RSI-001-S4-2W RSI-002-S4-2W RSI-003-S4-2W RSI-005-S4-2W RSI-007-S4-2W RSI-010-S4-2W RSI-015-S4-2W RSI-020-S4-2W RSI-025-S4-2W
Standard Duty HP 1
Heavy Duty
Dimensions (in.)
Weight (lbs.)
A
HP
A
4.2
0.5
2.5 9.5 6.5 6.1 9
H
W
D
2 6.8 1 4.8 9.5 6.5 6.1 9 3 9.6 2 7.8 9.5 6.5 8.5 9 5 15.2 3 11 12 8.7 6.5 14 7.5 22 5 17.5 12 8.7 6.5 14 10
28
7.5
25.3
17.4
10.8
7.9
30
15 42 10 37.2 17.4 10.8 7.9 30 20
54
15
48.3 20.2 11.3 11.7 50
25
68
20
62.1 20.2 11.3 11.7 50
110 V Input / 230 V Output Model Number
RSI-001-S4-1SW • •
Standard Duty HP 1
Heavy Duty
Dimensions (in.)
Weight (lbs.)
A
HP
A
4.2
0.5
2.5 9.5 6.5 6.1 9
H
W
D
Single phase 110 V input / 3 phase 230 V output
Web stocked
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 17
Standard Low Voltage Drive Products
NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series
460 V Model Number
RSI-001-S4-4W RSI-002-S4-4W RSI-003-S4-4W RSI-005-S4-4W RSI-007-S4-4W RSI-010-S4-4W RSI-015-S4-4W RSI-020-S4-4W RSI-025-S4-4W RSI-030-S4-4W RSI-040-S4-4W RSI-050-S4-4W RSI-060-S4-4W RSI-075-S4-4W RSI-100-S4-4W RSI-125-S4-4D * RSI-150-S4-4D * RSI-200-S4-4D *
Standard Duty HP
A
Heavy Duty HP
A
Dimensions (in.) H
W
D
Weight (lbs.)
1
2.1
0.5
1.1 9.5 6.5 6.1 9
2
3.4
1
2.1 9.5 6.5 6.1 9
3
4.8
2
3.4 9.5 6.5 8.5 9
5
7.6
3
4.8
12
8.7
6.5
14
7.5
11
5
7.6
12
8.7
6.5
14
10
14
7.5
11
12
8.7
6.5
14
15
21
10
14
17.4
10.8
7.9
30
20
27
15
21
17.4
10.8
7.9
30
25
34
20
27
17.4
10.8
7.9
30
30
40
25
34
17.4
10.8
7.9
30
40
52
30
40
20.2 11.3 11.7 50
50
65
40
52
20.2 11.3 11.7 50
60
77
50
65
29.4 12.9 13.8 95
75
96
60
77
29.4 12.9 13.8 95
100
124
75
96
29.4 12.9 13.8 95
125
156
100
124
50.5
16.5
18
305
150
180
125
156
50.5
16.5
18
305
200
240
150
180
50.5
16.5
18
305
Web Stocked *
Units ending in “D” are NEMA 12 and not washdown
2 - 18
To order: call 412-968-0100
Standard Low Voltage Drive Products
NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series
600 V Model Number
Standard Duty HP
A
Heavy Duty
Dimensions (in.)
HP
A
H
W
D
Weight (lbs.)
RSI-001-S4-6W
1
1.7
0.5
0.9
12 8.7 6.5 14
RSI-002-S4-6W
2
2.7
1
1.7
12 8.7 6.5 14
RSI-003-S4-6W
3
3.9
2
2.7
12 8.7 6.5 14
RSI-005-S4-6W
5
6.1
3
3.9
12 8.7 6.5 14
RSI-007-S4-6W
7.5
9
5
6.1
12 8.7 6.5 14
RSI-010-S4-6W
10
11
7.5
9
12 8.7 6.5 14
RSI-015-S4-6W
15
17
10
11
17.4 10.8 7.9
30
RSI-020-S4-6W
20
22
15
17
17.4 10.8 7.9
30
RSI-025-S4-6W
25
27
20
22
17.4 10.8 7.9
30
RSI-030-S4-6W
30
32
25
27
17.4 10.8 7.9
30
RSI-040-S4-6W
40
41
30
32
20.2 11.3 11.7 50
RSI-050-S4-6W
50
52
40
41
20.2 11.3 11.7 50
RSI-060-S4-6W
60
68
50
52
29.4 12.9 13.8 95
RSI-075-S4-6W
75
82
60
62
29.4 12.9 13.8 95
RSI-100-S4-6W
100
107
75
77
29.4 12.9 13.8 95
RSI-125-S4-6D *
125
125
100
99
50.5
16.5
18
305
RSI-150-S4-6D *
150
144
125
125
50.5
16.5
18
305
RSI-200-S4-6D *
200
192
150
140
50.5
16.5
18
305
*
Units ending in “D” are NEMA 12 and not washdown
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 19
Standard Low Voltage Drive Products
NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series options Display / Keypad Remote Mounting Options Catalog Number
Description
VFD-S4-REMOTE-KEYPAD-KIT
Includes remote keypad, interface board and 2M cable
VFD-XBLANKKPS0
Keypad blank, size 0 & 2, installs in drive when keypad is remote
VFD-XBLANKKPS1
Keypad blank, size 1, installs in drive when keypad is remote
VFD-XBLANKKPS3
Keypad blank, size 3, 4 and 5, installs in drrive when keypad is remote
VFD-S4-100FT-REMOTEKIT-A
100 foot remote display Kit, 30 HP and below
VFD-S4-100FT-REMOTEKIT-B
100 foot remote display Kit, 40 HP and above
Display / Keypad Replacement Catalog Number
Description
LCD-S4KEYPADS0R
Replacement keypad/display, S4 VFD, size 0 and 2
LCD-S4KEYPADS1R
Replacement keypad/display, S4 VFD, size 1
VFD-RSI-S4-REMOTEKEYPAD
Replacement keypad/display, for frame size 3, 4, and 5 and remote
Drive Mounting Options Catalog Number
Description
BRKT-100646-00
Fins out mounting bracket, 40 HP, 50 HP (frame size 3)
BRKT-100645-00
Fins out mounting bracket, 60 HP, 75 HP and 100 HP (frame size 4)
BRKT-100134-03
Fins out mounting bracket, 125 HP, 150 HP and 200 HP (frame size 5)
2 - 20
To order: call 412-968-0100
Standard Low Voltage Drive Options
Input Line Reactors 3% impedance
230 V Model Number
•
HP
A
Dimensions (in.)
Weight (lbs.)
Open
Enclosed (NEMA 1)
REA-KDRA25L
REA-KDRA25L-C1
1
4.6 6.5 8 6 8
REA-KDRA27L
REA-KDRA27L-C1
2
7.5 6.5 8 6 8
REA-KDRA28L
REA-KDRA28L-C1
3
10.6 6.5 8 6 8
REA-KDRB22L
REA-KDRB22L-C1
5
16.7 6.5 8 6 12
REA-KDRB23L
REA-KDRB23L-C2
7.5
24.2 7.5 10 7 14
H
W
D
REA-KDRD25L
REA-KDRD25L-C2
10
30.8 7.5 10 7 18
REA-KDRD24L
REA-KDRD24L-C2
15
46.2 7.5 10 7 18
REA-KDRD26L
REA-KDRD26L-C2
20
59.4 7.5 10 7 18
REA-KDRC22L
REA-KDRC22L-C2
25
74.8 7.5 10 7 21
REA-KDRF24L
REA-KDRF24L-C4
30
88 15.5 15 13 65
REA-KDRF25L
REA-KDRF25L-C4
40
114 15.5 15 13 65
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 21
Standard Low Voltage Drive Options
Input Line Reactors 3% impedance
480 V Model Number
•
HP
Dimensions (in.)
A
Weight (lbs.)
Open
Enclosed (NEMA 1)
REA-KDRA8L
REA-KDRA8L-C1
1
2.1 6.5 8 6 8
REA-KDRA1L
REA-KDRA1L-C1
2
3.4 6.5 8 6 8
REA-KDRA2L
REA-KDRA2L-C1
3
4.8 6.5 8 6 8
REA-KDRA3L
REA-KDRA3L-C1
5
7.6 6.5 8 6 8
REA-KDRA4L
REA-KDRA4L-C1
7.5
11 6.5 8 6 8
REA-KDRA5L
REA-KDRA5L-C1
10
14 6.5 8 6 9
REA-KDRB2L
REA-KDRB2L-C1
15
21 6.5 8 6 12
REA-KDRB1L
REA-KDRB1L-C1
20
27 6.5 8 6 12
REA-KDRD1L
REA-KDRD1L-C2
25
34 7.5 10 7 16
REA-KDRD2L
REA-KDRD2L-C2
30
40 7.5 10 7 16
H
W
D
REA-KDRC1L
REA-KDRC1L-C2
40
52 7.5 10 7 21
REA-KDRF2L
REA-KDRF2L-C3
50
65 9 12 8 37
REA-KDRF4L
REA-KDRF4L-C3
60
77 9 12 8 42
REA-KDRF3L
REA-KDRF3L-C4
75
96 15.5 15 13 65
REA-KDRH3L
REA-KDRH3L-C4
100
124 15.5 15 13 65
REA-KDRH2L
REA-KDRH2L-C4
125
156 15.5 15 13 75
REA-KDRH1L
REA-KDRH1L-C4
150
180 15.5 15 13 75
REA-KDRG3L
REA-KDRG3L-C4
200
240 15.5 15 13 100
REA-KDRG1L
REA-KDRG1L-C4
250
302 15.5 15 13 100
REA-KDRG2L
REA-KDRG2L-C4
300
361 15.5 15 13 100
REA-KDRJ2L
REA-KDRJ2L-C5
350
414 18.5 20 16 120
REA-KDRJ1L
REA-KDRJ1L-C5
400
477 18.5 20 16 120
REA-KDRL2L
REA-KDRL2L-C5
500
590 18.5 20 16 160
REA-KDRL3L
REA-KDRL3L-C5
600
720 18.5 20 16 205
REA-KDRS1L
REA-KDRS1L-C7
700
840
36 28.5 30.3 318
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
2 - 22
To order: call 412-968-0100
Standard Low Voltage Drive Options
Input Line Reactors 3% impedance
600 V Model Number
•
HP
A
Dimensions (in.)
Weight (lbs.)
Open
Enclosed (NEMA 1)
REA-KDRA50L
REA-KDRA50L-C1
1
1.7 6.5 8 6 8
REA-KDRA46L
REA-KDRA46L-C1
2
2.7 6.5 8 6 8
REA-KDRA52L
REA-KDRA52L-C1
3
3.9 6.5 8 6 8
REA-KDRA47L
REA-KDRA47L-C1
5
6.1 6.5 8 6 8
REA-KDRA48L
REA-KDRA48L-C1
7.5
9 6.5 8 6 8
REA-KDRA49L
REA-KDRA49L-C1
10
11 6.5 8 6 9
REA-KDRB45L
REA-KDRB45L-C1
15
17 6.5 8 6 12
REA-KDRB44L
REA-KDRB44L-C1
20
22 6.5 8 6 12
REA-KDRB43L
REA-KDRB43L-C1
25
27 6.5 8 6 12
REA-KDRD42L
REA-KDRD42L-C2
30
32 7.5 10 7 18
H
W
D
REA-KDRC43L
REA-KDRC43-C2
40
41 7.5 10 7 21
REA-KDRC44L
REA-KDRC44L-C2
50
52 7.5 10 7 21
REA-KDRF46L
REA-KDRF46L-C3
60
62 9 12 8 42
REA-KDRF47L
REA-KDRF47L-C3
75
77 9 12 8 42
REA-KDRF45L
REA-KDRF45L-C4
100
99 15.5 15 13 65
REA-KDRH43L
REA-KDRH43L-C4
125
125 15.5 15 13 80
REA-KDRH44L
REA-KDRH44L-C4
150
144 15.5 15 13 80
REA-KDRI42L
REA-KDRI42L-C4
200
192 15.5 15 13 85
REA-KDRG47L
REA-KDRG47L-C4
250
242 15.5 15 13 100
REA-KDRG45L
REA-KDRG45L-C4
300
289 15.5 15 13 100
REA-KDRJ45L
REA-KDRJ45L-C5
350
336 18.5 20 16 120
REA-KDRJ43L
REA-KDRJ43L-C5
400
382 18.5 20 16 120
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 23
Standard Low Voltage Drive Options
Input Line Reactors 5% impedance
240 V Model Number
•
HP
A
Dimensions (in.)
Weight (lbs.)
Open
Enclosed (NEMA 1)
REA-KDRA25H
REA-KDRA25H-C1
1
REA-KDRA26H
REA-KDRA26H-C1
2
7.5 6.5 8 6 8
REA-KDRA28H
REA-KDRA28H-C1
3
10.6 6.5 8 6 8
REA-KDRB25H
REA-KDRB25H-C1
5
16.7 6.5 8 6 12
H
W
D
4.6 6.5 8 6 8
REA-KDRB26H
REA-KDRB26H-C1
7.5 24.2 6.5 8 6 12
REA-KDRD21H
REA-KDRD21H-C2
10
30.8 7.5 10 7 18
REA-KDRD22H
REA-KDRD22H-C2
15
46.2 7.5 10 7 18
REA-KDRC22H
REA-KDRC22H-C2
20
59.4 7.5 10 7 21
REA-KDRF28H
REA-KDRF28H-C3
25
74.8 9 12 8 42
REA-KDRF25H
REA-KDRF25H-C4
30
88 15.5 15 13 65
REA-KDRF26H
REA-KDRF26H-C4
40
114 15.5 15 13 65
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
2 - 24
To order: call 412-968-0100
Standard Low Voltage Drive Options
Input Line Reactors 5% impedance
480 V Model Number
•
HP
A
Dimensions (in.)
Weight (lbs.)
Open
Enclosed (NEMA 1)
REA-KDRA8H
REA-KDRA8H-C1
1
2.1 6.5 8 6 8
REA-KDRA1H
REA-KDRA1H-C1
2
3.4 6.5 8 6 8
REA-KDRA2H
REA-KDRA2H-C1
3
4.8 6.5 8 6 8
REA-KDRA3H
REA-KDRA3H-C1
5
7.6 6.5 8 6 8
REA-KDRA4H
REA-KDRA4H-C1
7.5
11 6.5 8 6 9
REA-KDRA5H
REA-KDRA5H-C1
10
14 6.5 8 6 9
REA-KDRB2H
REA-KDRB2H-C1
15
21 6.5 8 6 11
REA-KDRC3H
REA-KDRC3H-C1
20
27 6.5 8 6 19
REA-KDRC1H
REA-KDRC1H-C2
25
34 7.5 10 7 21
H
W
D
REA-KDRE2H
REA-KDRE2H-C2
30
40 7.5 10 7 22
REA-KDRF4H
REA-KDRF4H-C3
40
52 9 12 8 37
REA-KDRF1H
REA-KDRF1H-C3
50
65 9 12 8 37
REA-KDRF2H
REA-KDRF2H-C3
60
77 9 12 8 37
REA-KDRH2H
REA-KDRH2H-C4
75
96 15.5 15 13 80
REA-KDRI2H
REA-KDRI2H-C4
100
124 15.5 15 13 87
REA-KDRG3H
REA-KDRG3H-C4
125
156 15.5 15 13 90
REA-KDRG1H
REA-KDRG1H-C4
150
180 15.5 15 13 90
REA-KDRJ1H
REA-KDRJ1H-C5
200
240 18.5 20 16 120
REA-KDRL1H
REA-KDRL1H-C5
250
302 18.5 20 16 160
REA-KDRL2H
REA-KDRL2H-C5
300
361 18.5 20 16 145
REA-KDRL3H
REA-KDRL3H-C5
350
414 18.5 20 16 150
REA-KDRL4H
REA-KDRL4H-C5
400
477 18.5 20 16 160
REA-KDRL6H
REA-KDRL6H-C5
500
590 18.5 20 16 170
REA-KDRS1H
REA-KDRS1H-C7
600
720
36 28.5 30.3 420
REA-KDRS2H
REA-KDRS2H-C7
700
840
36 28.5 30.3 420
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 25
Standard Low Voltage Drive Options
Input Line Reactors 5% impedance
600 V Model Number
•
HP
A
Dimensions (in.)
Weight (lbs.)
Open
Enclosed (NEMA 1)
REA-KDRA50H
REA-KDRA50H-C1
1
1.7 6.5 8 6 8
REA-KDRA43H
REA-KDRA43H-C1
2
2.7 6.5 8 6 8
REA-KDRA44H
REA-KDRA44H-C1
3
3.9 6.5 8 6 8
REA-KDRA45H
REA-KDRA45H-C1
5
6.1 6.5 8 6 8
REA-KDRB42H
REA-KDRB42H-C2
7.5
9 7.5 10 7 14
H
W
D
REA-KDRB43H
REA-KDRB43H-C2
10
11 7.5 10 7 14
REA-KDRB44H
REA-KDRB44H-C2
15
17 7.5 10 7 14
REA-KDRD41H
REA-KDRD41H-C2
20
22 7.5 10 7 18
REA-KDRC43H
REA-KDRC43H-C2
25
27 7.5 10 7 21
REA-KDRE42H
REA-KDRE42H-C2
30
32 7.5 10 7 22
REA-KDRF44H
REA-KDRF44H-C3
40
41 9 12 8 42
REA-KDRF45H
REA-KDRF45H-C3
50
52 9 12 8 42
REA-KDRH43H
REA-KDRH43H-C4
60
62 15.5 15 13 80
REA-KDRH42H
REA-KDRH42H-C4
75
77 15.5 15 13 80
REA-KDRI41H
REA-KDRI41H-C4
100
99 15.5 15 13 85
REA-KDRG44H
REA-KDRG44H-C4
125
125 15.5 15 13 100
REA-KDRG45H
REA-KDRG45H-C4
150
144 15.5 15 13 100
REA-KDRJ41H
REA-KDRJ41H-C5
200
192 18.5 20 16 120
REA-KDRL46H
REA-KDRL46H-C5
250
242 18.5 20 16 160
REA-KDRL47H
REA-KDRL47H-C5
300
289 18.5 20 16 160
REA-KDRL48H
REA-KDRL48H-C5
350
336 18.5 20 16 160
REA-KDRL49H
REA-KDRL49H-C5
400
382 18.5 20 16 160
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
2 - 26
To order: call 412-968-0100
Standard Low Voltage Drive Options
Output Reactors 1.5% impedance
480 V Model Number
•
HP
A
Dimensions (in.)
Weight (lbs.)
Open
Enclosed (NEMA 1)
REA-KDRA1P
REA-KDRA1P-C1
2
3.4 8 6.5 8 6
REA-KDRA2P
REA-KDRA2P-C1
3
4.8 8 6.5 8 6
REA-KDRA3P
REA-KDRA3P-C1
5
7.6 8 6.5 8 6
REA-KDRA4P
REA-KDRA4P-C1
7.5
11
REA-KDRB1P
REA-KDRB1P-C1
10
14 11 6.5 8 6
REA-KDRD1P
REA-KDRD1P-C2
15
21
16 7.5 10 7
REA-KDRD2P
REA-KDRD2P-C2
20
27
16 7.5 10 7
REA-KDRD3P
REA-KDRD3P-C2
25
34
18 7.5 10 7
REA-KDRD4P
REA-KDRD4P-C2
30
40
18 7.5 10 7
REA-KDRC1P
REA-KDRC1P-C2
40
52
21 7.5 10 7
REA-KDRF1P
REA-KDRF1P-C3
50
65 37 9 12 8
REA-KDRF2P
REA-KDRF2P-C3
60
77 37 9 12 8
REA-KDRF3P
REA-KDRF3P-C4
75
96
65 15.5 15 13
H
W
D
9 6.5 8 6
REA-KDRH1P
REA-KDRH1P-C4
100
124
75 15.5 15 13
REA-KDRI1P
REA-KDRI1P-C4
125
156
85 15.5 15 13
REA-KDRI2P
REA-KDRI2P-C4
150
180
90 15.5 15 13
REA-KDRG1P
REA-KDRG1P-C4
200
240
95 15.5 15 13
REA-KDRJ1P
REA-KDRJ1P-C5
250
302 120 18.5 20 16
REA-KDRJ2P
REA-KDRJ2P-C5
300
361 120 18.5 20 16
REA-KDRL1P
REA-KDRL1P-C5
350
414 135 18.5 20 16
REA-KDRL2P
REA-KDRL2P-C5
400
477 145 18.5 20 16
REA-KDRL3P
REA-KDRL3P-C5
450
515 150 18.5 20 16
REA-KDRL4P
REA-KDRL4P-C5
500
590 150 18.5 20 16
230 V drives/motors can operate with extended lead lengths (500 ft. or involves multiple motors from one drive, use an appropiately sized (current) 480 V reactor or a long lead fillter.
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 27
Standard Low Voltage Drive Options
Output Reactors 1.5% impedance
600 V Model Number
HP
Dimensions (in.)
A
Weight (lbs.)
Open
Enclosed (NEMA 1)
REA-KDRA31P
REA-KDRA31P-C1
2
2.7 8 6.5 8 6
REA-KDRA35P
REA-KDRA35P-C1
3
3.9 8 6.5 8 6
REA-KDRA33P
REA-KDRA33P-C1
5
6.1 8 6.5 8 6
REA-KDRA34P
REA-KDRA34P-C1
7.5
9
9 6.5 8 6
REA-KDRA36P
REA-KDRA36P-C1
10
11
9 6.5 8 6
H
W
D
REA-KDRD31P
REA-KDRD31P-C2
15
17
16 7.5 10 7
REA-KDRD32P
REA-KDRD32P-C2
20
22
16 7.5 10 7
REA-KDRD35P
REA-KDRD35P-C2
25
27
16 7.5 10 7
REA-KDRD33P
REA-KDRD33P-C2
30
32
18 7.5 10 7
REA-KDRD34P
REA-KDRD34P-C2
40
41
18 7.5 10 7
REA-KDRC31P
REA-KDRC31P-C2
50
52
21 7.5 10 7
REA-KDRF31P
REA-KDRF31P-C3
60
62 37 9 12 8
REA-KDRF32P
REA-KDRF32P-C3
75
77 37 9 12 8
REA-KDRF33P
REA-KDRF33P-C4
100
99
65 15.5 15 13
REA-KDRH31P
REA-KDRH31P-C4
125
125
75 15.5 15 13
REA-KDRI31P
REA-KDRI31P-C4
150
144
85 15.5 15 13
REA-KDRI32P
REA-KDRI32P-C4
200
192
90 15.5 15 13
REA-KDRG31P
REA-KDRG31P-C4
250
242
95 15.5 15 13
REA-KDRJ31P
REA-KDRJ31P-C5
300
289 120 18.5 20 16
REA-KDRJ32P
REA-KDRJ32P-C5
350
336 120 18.5 20 16
REA-KDRL31P
REA-KDRL31P-C5
400
382 135 18.5 20 16
2 - 28
To order: call 412-968-0100
Standard Low Voltage Drive Options
Long Lead Filters (DV/DT) 240 V
Dimensions (in.)
Model Number
•
HP
A
H (in.)W Dimensions
D Weight (lbs.)
Open
Enclosed (NEMA 1)
FLTR-V1K3A00
FLTR-V1K3A01
0.5
3
9 5.5 10 11
FLTR-V1K4A00
FLTR-V1K4A01
0.75
4
9 5.5 10 11
H
W
D
FLTR-V1K6A00
FLTR-V1K6A01
1~1.5
6
9 5.5 10 11
FLTR-V1K8A00
FLTR-V1K8A01
2
8
9 5.5 10 11
FLTR-V1K12A00
FLTR-V1K12A01
3
12
9 5.5 10 11
FLTR-V1K16A00
FLTR-V1K16A01
5
16
9 5.5 10 15
FLTR-V1K25A00
FLTR-V1K25A01
7.5
25
9 5.5 10 15
FLTR-V1K35A00
FLTR-V1K35A01
10
35
12 8 11.5 23
FLTR-V1K45A00
FLTR-V1K45A01
15
45
12 8 11.5 23
FLTR-V1K55A00
FLTR-V1K55A01
20
55
12 8 11.5 23
FLTR-V1K80A00
FLTR-V1K80A01
25~30
80
12 8 11.5 29
FLTR-V1K110A00
FLTR-V1K110A01
40
110 16.5 18 15 68
Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet. Long lead filters protect the motor from high DV/DT.
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 29
Standard Low Voltage Drive Options
Long Lead Filters (DV/DT) 480 V
Dimensions (in.)
Model Number
•
HP
A
H (in.)W Dimensions
D Weight (lbs.)
Open
Enclosed (NEMA 1)
FLTR-V1K2A00
FLTR-V1K2A01
0.75
2
9 5.5 10 11
FLTR-V1K3A00
FLTR-V1K3A01
1~1.5
3
9 5.5 10 11
H
W
D
FLTR-V1K4A00
FLTR-V1K4A01
2
4
9 5.5 10 11
FLTR-V1K6A00
FLTR-V1K6A01
3
6
9 5.5 10 11
FLTR-V1K8A00
FLTR-V1K8A01
5
8
9 5.5 10 11
FLTR-V1K12A00
FLTR-V1K12A01
7.5
12
9 5.5 10 11
FLTR-V1K16A00
FLTR-V1K16A01
10
16
9 5.5 10 15
FLTR-V1K18A00
FLTR-V1K18A01
10
18
9 5.5 10 15
FLTR-V1K21A00
FLTR-V1K21A01
15
21
9 5.5 10 15
FLTR-V1K25A00
FLTR-V1K25A01
15
25
9 5.5 10 15
FLTR-V1K27A00
FLTR-V1K27A01
20
27
9 5.5 10 15
FLTR-V1K35A00
FLTR-V1K35A01
25
35
12 8 11.5 23
FLTR-V1K45A00
FLTR-V1K45A01
30
45
12 8 11.5 23
FLTR-V1K55A00
FLTR-V1K55A01
40
55
12 8 11.5 23
FLTR-V1K80A00
FLTR-V1K80A01
50~60
80
12 8 11.5 29
FLTR-V1K110A00
FLTR-V1K110A01
75
110 16.5 18 15 68
FLTR-V1K130A00
FLTR-V1K130A01
100
130 16.5 18 15 83
FLTR-V1K160A00
FLTR-V1K160A01
125
160 16.5 18 15 83
FLTR-V1K200A00
FLTR-V1K200A01
150
200 16.5 18 15 93
FLTR-V1K250A00
FLTR-V1K250A01
200
250 16.5 18 15 93
FLTR-V1K305A00
FLTR-V1K305A01
250
305 16.5 18 30 117
FLTR-V1K362A00
FLTR-V1K362A01
300
362 16.5 18 30 117
FLTR-V1K420A00
FLTR-V1K420A01
350
420 16.5 18 30 132
FLTR-V1K480A00
FLTR-V1K480A01
400
480 16.5 18 30 138
FLTR-V1K600A00
FLTR-V1K600A01
500
600 16.5 18 30 168
FLTR-V1K750A00
FLTR-V1K750A01
600
750 16.5 18 30 180
Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet. Long lead filters protect the motor from high DV/DT.
2 - 30
To order: call 412-968-0100
Standard Low Voltage Drive Options
Long Lead Filters (DV/DT) 600 V
Dimensions (in.)
Model Number
•
HP
A
H (in.)W Dimensions
D Weight (lbs.)
Open
Enclosed (NEMA 1)
FLTR-V1K2A00
FLTR-V1K2A01
1
2
9 5.5 10 11
FLTR-V1K3A00
FLTR-V1K3A01
2
3
9 5.5 10 11
H
W
D
FLTR-V1K4A00
FLTR-V1K4A01
3
4
9 5.5 10 11
FLTR-V1K8A00
FLTR-V1K8A01
5
8
9 5.5 10 11
FLTR-V1K12A00
FLTR-V1K12A01
10
12
9 5.5 10 11
FLTR-V1K18A00
FLTR-V1K18A01
15
18
9 5.5 10 15
FLTR-V1K25A00
FLTR-V1K25A01
20
25
9 5.5 10 15
FLTR-V1K27A00
FLTR-V1K27A01
25
27
9 5.5 10 15
FLTR-V1K35A00
FLTR-V1K35A01
30
35
12 8 11.5 23
FLTR-V1K45A00
FLTR-V1K45A01
40
45
12 8 11.5 23
FLTR-V1K55A00
FLTR-V1K55A01
50
55
12 8 11.5 23
FLTR-V1K80A00
FLTR-V1K80A01
75
80
12 8 11.5 29
FLTR-V1K110A00
FLTR-V1K110A01
100
110 16.5 18 15 68
FLTR-V1K130A00
FLTR-V1K130A01
125
130 16.5 18 15 83
FLTR-V1K160A00
FLTR-V1K160A01
150
160 16.5 18 15 83
FLTR-V1K200A00
FLTR-V1K200A01
200
200 16.5 18 15 933
FLTR-V1K250A00
FLTR-V1K250A01
250
250 16.5 18 15 93
FLTR-V1K305A00
FLTR-V1K305A01
300
305 16.5 18 30 117
FLTR-V1K362A00
FLTR-V1K362A01
350
362 16.5 18 30 117
FLTR-V1K420A00
FLTR-V1K420A01
450
420 16.5 18 30 132
Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet. Long lead filters protect the motor from high DV/DT.
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 31
Standard Low Voltage Drive Options
Dynamic Brake Resistors and Brake Modules Dynamic brake resistors and modules are used to address over voltage conditions with drives. Over voltage trips occur when the DC bus in the drive increases to the over voltage trip level. This increase in voltage occurs when the mechanical energy in the motor is converted into regenerative electrical energy, which is transferred back into the drive (the motor acts like a generator). Regeneration occurs when: • The deceleration time is too quick. • The load has high inertia and keeps rotating after the drive output power has decreased below that of the load. (Ex: fly wheels, large fans) • The load is an over hauling load, cyclical or periodic. (Ex: pump jack, punch press) • When the motor suddenly becomes unloaded. (Ex: lumber mill saw applications) Regeneration can occur on an occasional basis or periodically (cyclical) depending on the type of load. A dynamic brake module and resistor are required to be added to the drive to dissipate this excess power. The module and resistor must be sized correctly depending on the application. Contact Benshaw for assistance with sizing brake resistors and brake modules.
2 - 32
To order: call 412-968-0100
Engineered Low Voltage Drive Packages overview Benshaw is a recognized industry leader in the shipment of engineered drives from our state-of-the-art factory, with dedicated engineering teams and a complete inventory of components necessary to build engineered solutions for you. Select the enclosure, disconnect, bypass, pilot devices, control strategy and filters required to meet your most demanding applications.
Control Modifications — Whatever you specify • Pilot devices, control power transformers, switches, meters, relays, space heaters, protective devices, PLCs, etc.
Combination Drive Packages — To meet your requirements • Circuit breaker protection • Non-fused disconnect protection • Fusible disconnect protection • Flange or rotary handle mechanism
Bypass Packages — To fit your application • Two contactor • Three contactor • Reduced voltage solid state starters
Enclosures — To Match your environment • Standard designs — NEMA 1, 12, 3R • Custom enclosures • Special enclosures — 4, 4X, air conditioned • Motor control centers
Filters — For your unique application • Line reactors 3% and 5% • Long lead filters • Load reactors • Harmonic filters • 18 pulse systems
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 33
Engineered Low Voltage Drive Products
Sensorless Vector Drives engineered packages part number assembler
RSI
060
SG
4
NC
A
01
VFD
Enclosure
RSI = Redistart Inverter
01=NEMA 1 12=NEMA 12 04=NEMA 4
Horsepower 001 = 1 HP
060 = 60 HP
3R=NEMA 3R
002 = 2 HP
075 = 75 HP
1A=NEMA 12 ventilated
003 = 3 HP
100 = 100 HP
005 = 5 HP
125 = 125 HP
Package Type
007 = 7.5 HP
150 = 150 HP
A = Packaged drive
010 = 10 HP
200 = 200 HP
015 = 15 HP
250 = 250 HP
B = Packaged drive with two contactor bypass
020 = 20 HP
300 = 300 HP
025 = 25 HP
400 = 400 HP
030 = 30 HP
500 = 500 HP
040 = 40 HP
600 = 600 HP
050 = 50 HP
700 = 700 HP
VFD Series
C = Packaged drive with three contactor bypass Disconnect Options Options NC = Non-combination CB = Circuit breaker FD = Fusible disconnect
SG = Sensorless Vector Drive S4 = Washdown Sensorless Vector Drive Voltage 2 = 230 V 4 = 460 V 6 = 600 V
2 - 34
To order: call 412-968-0100
Engineered Low Voltage Drive Products
Clean Power Drives sg 519 series IEEE-519 Compliant RATINGS Variable Torque: 7.5–700 HP @ 460 V 7.5–400 HP @ 600 V+ Standard Duty: 7.5–600 HP @ 460 V 7.5–400 HP @ 600 V+ Heavy Duty: 5–500 HP @ 460 V 5–300 HP @ 600 V+
Product Highlights:
Standard features:
Benshaw’s SG 519 Series drives are designed and manufactured to limit voltage and current distortion levels to within the levels defined by IEEE-519*. This eliminates the need for expensive, time consuming harmonic analysis and avoids the resonance problems associated with inefficient harmonic filters.
• UL listed
Our municipal projects and engineering team will work with you to configure a clean power solution that meets your specifications and requirements. Modular design The modular design of Benshaw’s SG 519 Series drives eliminates maintenance problems inherent in older drive designs and improves drive reliability by significantly reducing power module part counts. This design approach also allows each drive unit to be customtailored to your specific requirements. Optional bypass
• Limits voltage and current harmonics to IEEE-519* levels • Addresses poor power factor • Eliminates expensive harmonic analysis • Avoids resonance problems associated with inefficient harmonic filters • Prevents overloading of circuit breakers, feeders and transformers • Run from motor/generator systems • NEMA 1, 12V, 3R, 4 or 4X enclosures available, plus custom configurations
An optional bypass design configuration (ATL or RVSS) is available for SG 519 drive packages when mission critical reliability is important and disruptive downtime cannot be tolerated. * IEEE-519, 1992 Table 10-2 and Table 10-3. + Consult factory, not UL listed.
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 35
Custom-engineered drive solutions.
Whether you need simple modifications made to one of Benshaw’s standard drive packages, a custom engineered, application-specific drive package or a turnkey drive solution, Benshaw can help. With engineering experience and complete motor control system production capabilities, Benshaw delivers all of the competence, convenience and value you’d expect from a leader in engineered control systems. Whatever your motor control needs may be, Benshaw’s engineering teams and application specialists can help you find a cost-effective, reliable solution.
Quality assurance testing Benshaw’s assembly teams perform a preliminary quality assurance inspection before delivery is made. Drive assemblies undergo a variety of testing procedures, including motor operation testing, load testing, control circuit testing, wire pull testing, electrical performance checks, mechanical alignment inspection, torque measurement and user interface/ pilot device functionality. All test processes meet or exceed ISO 9001 requirements, and all tests are documented and archived for quality verification.
2 - 36
To order: call 412-968-0100
For any drive application. In any configuration.
Enclosures
Control modifications
• Standard NEMA 1, 12 and 3R enclosure designs • Custom enclosures
Over 250 control modifications and accessories are available from Benshaw, including:
• NEMA 4, 4X, air conditioned and other special enclosures
• Pilot devices • Control power transformers
• Motor control centers
• Switches
• Combination drive packages
• Meters
• 15–2,000 A circuit breakers
• Relays
• 40–2,000 A non-fused disconnects
• Space heaters
• 30–800 A fusible disconnects
• PLCs
• Flange or rotary handle mechanisms
• Protective devices
Bypass packages • Two contactor • Three contactor • Reduced voltage solid state starters Filters • Line reactors (3% and 5%) • Long lead filters • Passive harmonic filters • 18 pulse systems (IEEE-519)
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 37
Integrated control solutions using both Benshaw
Systems integration is a central focus of our business, and a competitive advantage for our customers Benshaw’s success in the OEM and industrial marketplace is a direct result of our willingness as a company to think “beyond the box”. We’ve made systems integration a central focus of our business, and we make learning your business a top priority. By focusing on the bigger picture we gain a better understanding of your process, your control requirements, and your market objectives. We then apply that knowledge toward the development and production of complete, costeffective, fully integrated control solutions.
2 - 38
Customized enclosures Benshaw takes great pride in our ability to design and deliver custom control enclosures that truly complement the form and function of your machine. NEMA 1, 12, 3R, 4 and 4X enclosures in unit mount, console mount, free-standing and wallmount configurations are available to suit your needs. Every enclosure we design is carefully crafted to meet your dimensional requirements, prototyped and tested for fit and compliance with relevant safety standards, fabricated to exacting tolerances and finished to your paint specification.
To order: call 412-968-0100
and additional brands.
Intelligent motor controls
Integrated control sensors
Benshaw offers a full range of intelligent, programmable, low and medium voltage starters and drives—from fractional to 20,000 HP—to meet a variety of motor control needs.
Benshaw can integrate any number of sensors, transducers, relays, switches, meters and protective devices, as required, to precisely monitor and respond to all critical process, machine or environmental variables.
Motor control products include full voltage starters, solid state reduced voltage starters and variable frequency drives. Reversing, two-speed, DC braking, wye-delta, synchronous and wound rotor control are supported.
Integrated machine logic Benshaw can supply standard or PC-based programmable logiccontrollers, and will custom design hardware or software to meet process requirements. Networking capabilities, remote monitoring and custom designed human machine interface packages are also available.
Integrated power packages Benshaw can also incorporate all of the power distribution components needed for your machine in one simple, plug-and-play package. Turnkey power distribution packages typically include all internal and external motor control wiring harnesses, power wiring harnesses, motor/machine sensor connections, and, if needed, a fully integrated power factor correction unit.
Typical OEM/Industrial applications • Air and process compressors • Blowers and air handling equipment • Chillers • Conveyors • Food/liquid processing equipment • Industrial refrigeration equipment • Municipal waste/water handling machines • Pumps • Pipelines • Shredders/grinders • Specialty machinery • Transfer lines
All power systems are factory tested at Benshaw with custombuilt machine simulators and wire pull-testers to guarantee reliable performance.
To order WEB STOCKED items: visit www.BenshawExpress.com
2 - 39
2 - 40
To order: call 412-968-0100
Medium Voltage Starters Standard Medium Voltage Starter Products MX3 Controller...........................................................2 Solid State Starters..................................................4
Engineered Medium Voltage Starter Products Combination Solid State Starters...........................11 Smart Full Voltage ATL Starters..............................15 Full Voltage ATL Starters.........................................18 Main Lug Only.........................................................20 Load Interrupter Switch..........................................23 Wound Rotor Starters.............................................25 Synchronous Starters.............................................26 Mechanical Packaging Options..............................27 Turnkey Solutions...................................................28
Engineered Medium Voltage Starter Options Pilot Devices...........................................................30 Control Options.......................................................32 Motor Protection Relays.........................................34 Enclosure Options...................................................35 Power Factor Correction Capacitors.......................36 Surge / Lighting Arrestors.......................................38 Surge Capacitors....................................................39 Line Reactors..........................................................40 Documentation.......................................................41 To order WEB STOCKED items: visit www.BenshawExpress.com
3-1
Standard Medium Voltage Starter Products
Next Generation Intelligent Motor Control mx3 controller
KEYPAD (INCLUDED)
OPTIONAL RTD MODULES
Highlights:
Key Features:
Next generation MX technology forms the backbone of Benshaw’s entire line of intelligent medium voltage motor controls. With fiber optic firing, enhanced programming capabilities, ease of use, and a unique, flexible architecture—Benshaw’s MX3 controller delivers unprecedented functionality and all of the rugged, dependable performance you’ve come to expect from a world leader in solid state motor controls and drives. 3
MX3 controllers, power components, software and sensors are all designed, built and tested to perform as an integrated control system, eliminating the coordination and performance problems inherent in other forms of reduced voltage starting. With more built-in features, more configurable options, greater expandability and a broader communications capability than any other motor control on the market, Benshaw’s next generation MX3 technology will shorten your commissioning times, improve motor performance and protection, enhance diagnostic capability and streamline many electrical system monitoring and maintenance tasks. 3-2
FIBER OPTIC FIRING • Integrated technology • Noise immunity • High voltage isolation • Safe, reliable SCR control
• High performance motor control with multiple starting modes built-in • Flexible, programmable I/O • Integrated motor protection • Line and motor metering • Diagnostic capabilities with event log and real-time clock • Built-in remote self-testing (BIST) • Expanded communications capabilities • Intelligent SCR power poles • Intelligent MV MCC integration
To order: call 412-968-0100
Standard Medium Voltage Starter Products
Next Generation Intelligent Motor Control mx3 controller control features Multiple Starting Modes:
• Control power low
• Voltage ramp
• Stack over temperature
• Current ramp
• Motor PTC input
- Adjustable initial current
• RTD modules
- Adjustable maximum current - Adjustable ramp time • Torque ramp (TruTorque) - Adjustable initial torque - Adjustable maximum torque
Metering: • Accuracy: - 3% out-of-box - 2% factory calibrated • Average current • L1 current
- Adjustable ramp time
• L2 current
• Power ramp
• L3 current
- Adjustable initial torque
• Current imbalance %
- Adjustable maximum torque
• Ground fault current
- Adjustable ramp time
• L1 – L2 voltage
• Linear/tach feedback control
• L2 – L3 voltage
Motor Protection: • Motor thermal overload • Independent starting and running OL’s
• Average volts
• L3 – L1 voltage • Overload % • Power factor • Watts
• Up to speed timer exceeded
• VA
• Low line voltage
• KW hours
• Low line frequency
• MW hours
• High line frequency
• Phase order
• Phase reversal
• Line frequency
• Phase loss
• Analog input
• Instantaneous overcurrent
• Analog output
• Overcurrent
• Run time — days
• Undercurrent
• Run time — hours
• Current imbalance
• # of starts
• Ground fault (residual or zero sequence)
• Tru Torque %
• Shorted or open SCR • Disconnect fault • Inline contactor fault
• VARS
8 Digital Inputs Configurable to: • Stop • Fault
1 Analog 4 – 20 mA / 0 – 10 Vdc Input Configurable to: • Trip high level
• Fault reset
• Trip low level
• Bypass / inline confirm
1 Analog 4 – 20 mA / 0 – 10 Vdc Output Configurable to:
• OL reset • Local/remote selection • Heater enable
• Current (0 – 200%/0 – 800%)
• Heater disable
• Voltage (0 – 150%)
• Dual ramp selection
• OL (0 – 150%)
• 1 dedicated start input
• kW (0 – 10 kW/0 – 100 kW)
• Disconnect
• MW (0 – 1 MW)
• Slow speed
• Analog input (0 – 100%)
• Brake enable
• Firing (0 – 100%)
• Brake disable
• Calibration
6 Relay Outputs Configurable to:
User Interface:
• Faulted • Running • Up to speed • Alarm condition • Ready condition • Locked out • Over current
• Event log (99 events) • Door mounted LCD display - Set/examine operating parameters - View status information, line current, voltage and frequency
• Under current
- Start and stop the solid state starter
• OL alarm
1 Communication Port:
• Shunt trip
• ModBus / RS485
• Ground fault • Energy saver indication • Heating indication • Cooling fan
• Power % • Peak starting current
Advanced Functionality: • Dual ramp selection • Adjustable kick current • Programmable decel modes • MV BIST test (built-in self test)
• Last starting duration • RTD temperatures • Real-time clock
To order WEB STOCKED items: visit www.BenshawExpress.com
3-3
Standard Medium Voltage Starter Products
Prepackaged Solid State Starters
MVRXE SERIES emergency atl bypass, severe duty, load break fusible disconnect
Highlights: The Benshaw Medium Voltage Starter is a microprocessor controlled solid state reduced voltage starter for three phase induction motors. The starter provides a closed-loop current ramp for smooth stepless motor acceleration. Supplied in a free standing enclosure. Enclosures are available in NEMA 12 or NEMA 3R configurations. The medium voltage enclosure consists of two distinct compartments. The medium voltage or power pole section is located in the main body of the enclosure, whereas the low voltage section containing the control logic is located behind the door as an isolated compartment. Each starter is supplied with a load break isolation switch, Class “R” motor fuses, inline vacuum contactor, solid state power poles, and a vacuum bypass contactor, which is used to bypass the SCR power poles once the motor is up to full speed. The logic control incorporates the MX3 computer that has all the circuitry required to drive the power semiconductors, which are located in the power section. MVRXE starters provide solid state reduced voltage starting for normal operation and full voltage emergency back-up starting, with complete electronic motor protection at the flip of a switch.
Key Advantages:
This unique redundant design is ideal for critical applications where downtime is extremely disruptive and cannot be tolerated.
• Service entrance labeled (optional)
MX3 solid state controls provide precise digital starting and stopping, motor protection, metering, diagnostics and communications, standard.
• Solid state reduced voltage starting — normal operations
• NEMA 12, UL 347 listed • 45 kV BIL • Built-in self test (BIST) features for “quick commissioning”
• 425 A load break • Switch selectable emergency backup full voltage starter • MX3-embedded digital control • Fiber optic firing • Advanced motor protection • Advanced metering • Power quality protection • Diagnostics and ModBus RTU485 communications standard
3-4
To order: call 412-968-0100
Standard Medium Voltage Starter Products
Prepackaged Solid State Starters
MVRXE SERIES emergency atl bypass, severe duty, load break fusible disconnect
Standard Features: • NEMA 12, solid state starter, UL347 listed, Class E-2 • 45 kV BIL • 200 MVA (2300 Vac)/350 MVA (4160 Vac) short circuit fault rated. • 500% – 30 seconds rated solid state starter — UL347 certified and listed. • 8,000 PIV — UL347 certified and listed at 2.4kV • 12,000 PIV — UL347 certified and listed at 4.2kV • Fiber optic firing
• 425 A load break, 5 kV rated disconnect switch, with viewing window, grounding assembly and lockable handle mechanism. Mechanically interlocked for safety. • Fixed mounted, start duty rated vacuum contactors for isolation and SCR bypass, wired for normal bypass operation and full voltage start operation, with (2) N/O and (2) N/C auxiliary contacts. • Separately mounted “SPE” series electronic overload device has the following standard features:
• Selectable solid state or emergency full voltage operation via selector switch mounted inside of LV compartment
- Class 10 – 30 adjustable
• Load matched Class R fusing with blown fuse indication
- Phase reversal protection
- Phase imbalance protection - 1 NO/1 NC trip contact - “Trip free” design - Phase loss protection
Benshaw MVRXE vs. any autotransformer starter Motor Control & Protection Functions
Any Auto Transformer
Benshaw MVRXE
Soft Start
YES
YES
Soft Stop
NO
YES
Full Voltage Bypass Starting
NO
YES
Load Break Disconnect Switch
NO
YES
Built-In Self Test
NO
YES
UL 347/Service Entrance Rated (Optional)
NO
YES
3 Year Warranty
NO
YES
Plain English Digital Display
NO
YES
Electronic OL Protection
NO
YES
Electronic Power Quality
NO
YES
Digital Metering
NO
YES
Embedded Plain English Diagnostics
NO
YES
Embeded RS485
NO
YES
Incoming Line Landing Pad
NO
YES
Integrated Control & Protection
NO
YES
UL Zero Sequence Ground Fault *
NO
YES
To order WEB STOCKED items: visit www.BenshawExpress.com
• Built-in self test (BIST) features for “quick commissioning” • 120 Vac, 1000 VA CPT with primary and secondary fusing, with 500 VA available for customer use • Door-mounted start and stop push-buttons. • Door-mounted LCD keypad • Door-mounted run indication light • Door-mounted local-off-remote switch • Door-mounted reset button • Terminal strip mounted inside LV compartment for: - Remote start/stop control - Remote up-to-speed indication - Remote run indication - Remote fault indication • Benshaw MX3 controller with complete soft start, soft stop and motor protection capabilities • 485 communications capabilities — local through door connection or remote from starter (optional) • ModBus communications standard
* Optional ground fault CT required
3-5
Standard Medium Voltage Starter Products
Prepackaged Solid State Starters
MVRXE SERIES emergency atl bypass, severe duty, load break fusible disconnect MVRXE12—2300 V Model Number
HP
A
MVRXE12-650-2300-** MVRXE12-750-2300-** MVRXE12-1500-2300-**
650
Dimensions (in.)
Weight (lbs.)
H
W
D
160
92
36
32
1,800
750
180
92
36
32
1,800
1500
360
92
36
32
1,800
Model Number
HP
A
MVRXE18-1000-4160-** MVRXE18-1500-4160-** MVRXE18-3000-4160-**
1000 133 92 36 32 2,000
MVRXE18—4160 V
•
Dimensions (in.) H
W
D
Weight (lbs.)
1500 200 92 36 32 2,000 3000 360 92 36 32 2,000
Starters are top entry / bottom exit — top exit available upon request. Dimensions and weights are approximate.
** Insert appropriate option code as shown: NEMA 12 = 12 / NEMA 3R = 3R
Web stocked NOTE: Power fuses ship loose. Please provide motor full load amps at time of order for proper fuse sizing.
Modular Options Catalog Number
Description
A171 A008 A406 A407 A408 *
SPACE HEATER WITH THERMOSTAT (INCLUDED IN NEMA 3R OPTION) Description E-STOP PUSH-BUTTON, MUSHROOM HEAD, RED
TOP LEFT OR TOP RIGHT MOUNTING, ACCOMODATES STRESS CONES
8 CHANNEL RTD MODULE, 100 OHM PLATINUM (ALSO AVAILABLE FOR REMOTE MOUNTING) 16 CHANNEL RTD MODULE(S), 100 OHM PLATINUM (ALSO AVAILABLE FOR REMOTE MOUNTING) TOP HAT ENCLOSURE MODULE FOR TOP ENTRY (18”H X 30”W X 20”D),
A409 SERVICE ENTRANCE LABELED A106 ADDITIONAL 1000VA CONTROL POWER TRANSFORMER •
The MVRXE series was designed as an integrated package. Listed above are the available modular options. For systems requiring more extensive requirements, please refer to the engineered section of the MV catalog.
*
Top hat will ship loose for customer installation.
## Built-to-order: Please allow 2 weeks for shipment of complete MVRXE unit when ordering these options to a stock starter.
Protective Relay Options Catalog Number
Description
A875
GROUND FAULT CT, 2000:1, 4.0:DIA. (FOR MX3 USE)
A876
GROUND FAULT CT, 2000:1, 8.13:DIA. (FOR MX3 USE)
3-6
To order: call 412-968-0100
Built-To Order, 2 Week Shipment
Solid State Reduced Voltage Starters 4,160 Volt MVRMX Series 0–1,500 HP or 1,501–3,000 HP
Highlights: Benshaw has analyzed and value engineered our MV SSRV Engineered-To-Order product options, and developed a modular architecture, to offer those options most ordered on a Built-To-Order program. This has enabled us to offer you a customized product with a reduced lead time. Our goal is to optimize our response to meet your mission critical application needs. The RediStart CFMVRMX series with MX3 technology is a fully integrated, programmable family of Class E2 load break/combination solid state starters. This integrated design includes control and power electronics, bypass and isolation contactors that reduce maintenance and operating costs when compared to other methods.
Key Advantages: Protect machinery from failure and excessive maintenance caused by mechanical shock during starting or stopping. The RediStart MVRMX provides smooth, stepless acceleration and controlled deceleration.
Power Section Features: Description
Specification
Starting Method
Closed Loop Current Control Ramp Torque Ramp Power Ramp (kW) Voltage Ramp Linear Accel/Tach Feedback
Protect electrical systems from disruptive voltage drops and power outages caused by motor locked rotor inrush current. The RediStart MVRMX starter precisely controls the current ramp during start up.
Power Ratings
Reference Table A (next page)
Control Input
120 Vac or Dry Contact, 2 or 3 Wire
Standard Insulation Test
2X RATED V + 2,000 V
Nominal Voltage Ratings
4.16 kV
Ambient Temperature
0 – 40° C to 3,300 ft.
Protect mission critical motors from failure or unscheduled outages caused by machine or electrical system faults. The RediStart MVRMX starter provides complete, high performance, coordinated line monitoring, motor control and protection.
Frequency Range
23–72 Hz on Control Board
Overall Efficiency (W/Bypass)
99.5%
Metering Functions
47 Parameters
Relay Outputs
24 Functions
Over/Under Voltage Protection
10 to 30%
Power Loss (W/Bypass)