2013 Product Catalog Advanced Controls & Drives Effective April 1, 2013

Medium Voltage Variable Frequency Drives

SECTION 1

Low Voltage Variable Frequency Drives

SECTION 2

Medium Voltage Starters

SECTION 3 SECTION 4

Low Voltage Starters

http://benshaw.cwfc.com

24/7/365 Service and Support Field Services

• Installations & commissioning • On-site repairs - Scheduled/emergency • On-site retrofits and upgrades

Factory Services

• Send-in repairs - Scheduled/emergency • Send-in retrofits and upgrades • Quick ship modified —  Benshaw Express stock • Benshaw and 3rd party

Technical Training

• In-class in our training center • In-class at your facility • Customized for your business

Maintenance Services

• Thermography • Service contracts • Preventive - Maintenance / agreements • Power quality

Spare Parts

• 24/7/365 availability • Emergency delivery - Courier available • Replace or repair

Technology Retrofits

• Solid state motor controls and drives • Electromechanical motor controls • Orphaned OEM equipment retrofits

Medium Voltage Variable Frequency Drives Engineered Medium Voltage Drive Products M2L 3000 Series.......................................................2

To order WEB STOCKED items: visit www.BenshawExpress.com

1-1

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP

Introducing ... With over 20 years of medium voltage motor controls experience, Benshaw is now introducing a new family of medium voltage drives. Our medium voltage drive features a unique technology that allows Benshaw to offer a simple, compact, and reliable drive solution. Our innovative topology, coupled with an advanced control architecture, will enable customers to transform the way they do business. The M2L 3000 Medium Voltage Variable Frequency Drive is a step change in motor control power technology. Though designed for industrial applications, it benefits from Curtiss-Wright’s wide ranging experience in defense and nuclear-related technologies, an arena where products must meet the most rigorous standards and where failure is simply not an option. Our innovative patented topology — modular multilevel converter (M2LC) — is powered by state-of-the-art hardware and software controls. Our control algorithms are setting the stage for the next generation of VFDs.

Key Features: Compact Modular Design Simplistic component arrangement with minimal total part count

Installation Flexibility Optimal for retrofits

Arc Resistant Safety by design — arc flash footprint inherently lower

Energy Efficiency Inverter efficiency ≥99.5%

XCS Converter

M2L Inverter

Developed, designed, and manufactured in the USA. Supported around the globe.

Robust Control Architecture High performance, reliability and immunity from EMI, through noise tolerant signaling & fiber optic communications

1-2

To learn more about the M2L 3000, visit http://benshaw.cwfc.com, call 412-968-0100 or e-mail [email protected].

To order: call 412-968-0100

Engineered Medium Voltage Drive Products

Variable Frequency Drives

m2l 3000 series FRAME SIZES / weights / model number assembler - overview Converter Frame Sizes Frame

Model Number Assembler - Overview

Dimensions (in.) H

W

D

Weight (lbs.)

1

66 64 40 6200

2

91 76 44 9200

3

* *

*

Supply Voltage

*

Choose:



Disconnect Option

Inverter Frame Sizes Frame

Page 1-17

Dimensions (in.) H

W

D

Weight (lbs.)

1

66 61 40 1452

2

74 71 40 1500

3

* *

*

*

* = Consult factory

Choose:

Choose:

Supply Voltage Supply Frequency Motor Current

Uptime Option

Page 1-4

Page 1-17

Choose:

XCS Converter

M2L Inverter

M

Converter front

Converter side

To order WEB STOCKED items: visit www.BenshawExpress.com

Inverter front

Motor Voltage Motor Current Page 1-5

Motor

Inverter side

1-3

Engineered Medium Voltage Drive Products

Variable Frequency Drives

m2l 3000 series model number assembler - converter section Example Part Number:

XCS-3

4

6

4

0140

Options**

Series: XCS-3 = M2L-3000 Converter Input Voltage: 1 = 480 2 = 2400 3 = 3300 4 = 4160 5 = 4800 6 = 6600 7 = 6900 8 = 8320 A = 10000 B = 11000 C = 12000 D = 12470 E = 13200 F = 13800 Z = Other (specify at time of ordering) Input Freqency: 5 = 50 Hz 6 = 60 Hz Motor / Inverter Output Voltage: (Must match M2L-3 Output Voltage code) 2 = 2300 3 = 3300 4 = 4160 5 = 4800 * 6 = 6600 7 = 6900 8 = 8320 * A = 10000 * B = 11000 * C = 12000 * D = 12470 * E = 13200 * F = 13800 * Z = Other (specify at time of ordering) Inverter Output Rated Current (Total): 0035 = 35 amps 0070 = 70 amps 0100 = 100 amps 0140 = 140 amps 0190 = 190 amps 0260 = 260 amps 0300 = 300 amps 0440 = 440 amps 0550 = 550 amps 0880 = 880 amps * 1200 = 1200 amps * Blank = Standard / Base Unit OP = Options selected. For Option choices see page 12. * = Consult factory

1-4

To order: call 412-968-0100

Engineered Medium Voltage Drive Products

Variable Frequency Drives

m2l 3000 series model number assembler - inverter section Example Part Number:

M2L-3

X

6

4

0140

Options**

Series: M2L-3 = M2L-3000 Inverter Section Input Supply: X = with XCS Transformer Converter Section D = DC Bus Supply (Inverter only), Consult factory for voltage specifications Motor / Output Base Freqency: 5 = 50 Hz 6 = 60 Hz Motor / Inverter Output Voltage: (Must match XCS-3 Output Voltage code, when XCS is supplied) 2 = 2300 3 = 3300 4 = 4160 5 = 4800 * 6 = 6600 7 = 6900 8 = 8320 * A = 10000 * B = 11000 * C = 12000 * D = 12470 * E = 13200 * F = 13800 * Z = Other (specify at time of ordering) Inverter Output Rated Current: 0035 = 35 amps 0070 = 70 amps 0100 = 100 amps 0140 = 140 amps 0190 = 190 amps 0260 = 260 amps 0300 = 300 amps 0440 = 440 amps 0550 = 550 amps 0880 = 880 amps * 1200 = 1200 amps * Blank = Standard / Base Unit OP = Options selected. For Option choices see page 12. * = Consult factory

To order WEB STOCKED items: visit www.BenshawExpress.com

1-5

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 2.3 kV Converter Input & Output 60 Hz

Cell Current

Dimensions (in.)

Weight (lbs.)

Model Number

HP

XCS-32620140

500

140

1

66 64 40 6200

XCS-32620140

600

140

1

66 64 40 6200

XCS-32620190

700

190

2

91 76 44 9200

XCS-32620190

800

190

2

91 76 44 9200

XCS-32620260

900

260

2

91 76 44 9200

XCS-32620260

1000

260

2

91 76 44 9200

XCS-32620300

1250

300

2

91 76 44 9200

XCS-32620440

1500 440 3 *

*

*

*

XCS-32620440

1750 440 3 *

*

*

*

XCS-32620440

2000 440 3 *

*

*

*

XCS-32620550

2250 550 3 *

*

*

*

XCS-32620550

2500 550 3 *

*

*

*

XCS-32620880

3000 880 3 *

*

*

*

XCS-32620880

3500 880 3 *

*

*

*

Frame

H

W

D

* = Consult factory

1-6

To order: call 412-968-0100

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 2.3 kV Inverter Input & Output 60 Hz

Cell Current

Dimensions (in.)

Weight (lbs.)

Model Number

HP

M2L-3X620140

500

140

1

66 61 40 1452

M2L-3X620140

600

140

1

66 61 40 1452

M2L-3X620190

700

190

2

74 71 40 1500

M2L-3X620190

800

190

2

74 71 40 1500

M2L-3X620260

900

260

2

74 71 40 1500

M2L-3X620260

1000

260

2

74 71 40 1500

M2L-3X620300

1250

300

2

74 71 40 1500

M2L-3X620440

1500 440 3 * *

*

*

M2L-3X620440

1750 440 3 * *

*

*

M2L-3X620440

2000 440 3 *

*

*

*

M2L-3X620550

2250 550 3 *

*

*

*

M2L-3X620550

2500 550 3 *

*

*

*

M2L-3X620880

3000 880 3 *

*

*

*

M2L-3X620880

3500 880 3 *

*

*

*

Frame

H

W

D

* = Consult factory

To order WEB STOCKED items: visit www.BenshawExpress.com

1-7

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 3.3 kV Converter Input & Output 60 Hz

Cell Current

Dimensions (in.)

Weight (lbs.)

Model Number

HP

XCS-33630100

500

100

1

66 64 40 6200

XCS-33630100

600

100

1

66 64 40 6200

XCS-33630140

700

140

1

66 64 40 6200

XCS-33630140

800

140

1

66 64 40 6200

XCS-33630190

900

190

2

91 76 44 9200

XCS-33630190

1000

190

2

91 76 44 9200

XCS-33630260

1250

260

2

91 76 44 9200

XCS-33630260

1500

260

2

91 76 44 9200

XCS-33630300

1750

300

2

91 76 44 9200

XCS-33630440

2000 440 3 *

*

*

*

XCS-33630440

2250 440 3 *

*

*

*

XCS-33630440

2500 440 3 *

*

*

*

XCS-33630550

3000 550 3 *

*

*

*

XCS-33630550

3500 550 3 *

*

*

*

XCS-33630880

4000 880 3 *

*

*

*

XCS-33630880

4500 880 3 *

*

*

*

XCS-33630880

5000 880 3 *

*

*

*

Frame

H

W

D

* = Consult factory

1-8

To order: call 412-968-0100

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 3.3 kV Inverter Input & Output 60 Hz

Cell Current

Dimensions (in.)

Weight (lbs.)

Model Number

HP

M2L-3X630100

500

100

1

66 61 40 1452

M2L-3X630100

600

100

1

66 61 40 1452

M2L-3X630140

700

140

1

66 61 40 1452

M2L-3X630140

800

140

1

66 61 40 1452

M2L-3X630190

900

190

2

74 71 40 1500

M2L-3X630190

1000

190

2

74 71 40 1500

M2L-3X630260

1250

260

2

74 71 40 1500

M2L-3X630260

1500

260

2

74 71 40 1500

M2L-3X630300

1750

300

2

74 71 40 1500

M2L-3X630440

2000 440 3 *

*

*

*

M2L-3X630440

2250 440 3 *

*

*

*

M2L-3X630440

2500 440 3 *

*

*

*

M2L-3X630550

3000 550 3 *

*

*

*

M2L-3X630550

3500 550 3 *

*

*

*

M2L-3X630880

4000 880 3 *

*

*

*

M2L-3X630880

4500 880 3 *

*

*

*

M2L-3X630880

5000 880 3 *

*

*

*

Frame

H

W

D

* = Consult factory

To order WEB STOCKED items: visit www.BenshawExpress.com

1-9

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 4.2 kV Converter Input & Output 60 Hz

Cell Current

Dimensions (in.)

Weight (lbs.)

Model Number

HP

XCS-34640070

500

70

1

66 64 40 6200

XCS-34640100

600

100

1

66 64 40 6200

XCS-34640100

700

100

1

66 64 40 6200

XCS-34640140

800

140

1

66 64 40 6200

XCS-34640140

900

140

2

66 64 40 6200

XCS-34640140

1000

140

2

66 64 40 6200

XCS-34640190

1250

190

2

91 76 44 9200

XCS-34640190

1500

190

2

91 76 44 9200

XCS-34640260

1750

260

2

91 76 44 9200

XCS-34640260

2000

260

3

91 76 44 9200

XCS-34640300

2250

300

3

91 76 44 9200

XCS-34640440

2500 440 3 *

*

*

*

XCS-34640440

3000 440 3 *

*

*

*

XCS-34640440

3500 440 3 *

*

*

*

XCS-34640550

4000 550 3 *

*

*

*

XCS-34640880

4500 880 3 *

*

*

*

XCS-34640880

5000 880 3 *

*

*

*

XCS-34640880

5500 880 3 *

*

*

*

XCS-34640880

6000 880 3 *

*

*

*

Frame

H

W

D

* = Consult factory

1 - 10

To order: call 412-968-0100

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series 2.3–6.6 kV Class, 300–10,000 HP 4.2 kV Inverter Input & Output 60 Hz

Cell Current

Dimensions (in.)

Weight (lbs.)

Model Number

HP

M2L-3X640070

500

70

1

66 61 40 1452

M2L-3X640100

600

100

1

66 61 40 1452

M2L-3X640100

700

100

1

66 61 40 1452

M2L-3X640140

800

140

1

66 61 40 1452

M2L-3X640140

900

140

2

66 61 40 1452

M2L-3X640140

1000

140

2

66 61 40 1452

M2L-3X640190

1250

190

2

74 71 40 1500

M2L-3X640190

1500

190

2

74 71 40 1500

M2L-3X640260

1750

260

2

74 71 40 1500

M2L-3X640260

2000

260

3

74 71 40 1500

M2L-3X640300

2250

300

3

74 71 40 1500

M2L-3X640440

2500 440 3 *

*

*

*

M2L-3X640440

3000 440 3 *

*

*

*

M2L-3X640440

3500 440 3 *

*

*

*

M2L-3X640550

4000 550 3 *

*

*

*

M2L-3X640880

4500 880 3 *

*

*

*

M2L-3X640880

5000 880 3 *

*

*

*

M2L-3X640880

5500 880 3 *

*

*

*

M2L-3X640880

6000 880 3 *

*

*

*

Frame

H

W

D

* = Consult factory

To order WEB STOCKED items: visit www.BenshawExpress.com

1 - 11

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series options Certifications Catalog Number

Description

C01

UL Listing*

C02

CE Conformity*

C03

CSA Certification*

Fieldbus Commuications Catalog Number

Description

FBC01

Profibus DP

FBC02

Modbus TCP/IP

FBC03

Ethernet IP

FBC04

Device Net

Motor Control Catalog Number

Description

MC01

Four Quadrant Control*

MC02

Bidirectional Bumpless Transfer*

Control Accessories Catalog Number

Description

CA01

Pushbutton Control

CA02

Local - Off - Remote Selector

CA03

Hand - Off - Auto Selector

CA04

Keyed Local - Off - Remote Selector

CA05

Keyed Hand - Off - Auto Selector

Cooling Fan / Control Power Catalog Number

Description

TR01

2300/220 VAC 10 KVA

TR02

3300/220 VAC 10 KVA

TR03

4160/220 VAC 10 KVA

TR04

6600/220 VAC 10 KVA

TR05

6900/220 VAC 10 KVA

* = Consult factory

1 - 12

To order: call 412-968-0100

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series options Disconnect Catalog Number

Description

CF01

400 Amp, Fused, 24” x 92”

CF02

1200 Amp Fused aa x bb

CF03 circuit breaker

Uptime Enhancement Catalog Number

Description

UE01

Solid State Cell Bypass*

UE02

redundant fans*

UE03

Medium voltage reduce voltage starter bypass

UE04

ATL starter bypass

Drive Interface Catalog Number

Description

HMI01

11 inch touch pad HMI

HMI02

Smart Device (ipad)*

* = Consult factory

To order WEB STOCKED items: visit www.BenshawExpress.com

1 - 13

Engineered Medium Voltage Drive Products

Variable Frequency Drives m2l 3000 series connection diagram

*

* Customer Supplied

1 - 14

To order: call 412-968-0100

Low Voltage Variable Frequency Drives Standard Low Voltage Drive Products General Purpose Micro Drives..................................2 Sensorless Vector Drives..........................................5 Built-To-Order Packaged Drives.............................10 NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives........................................15

Standard Low Voltage Drive Options Input Line Reactors.................................................21 Output Reactors......................................................27 Long Lead Filters....................................................29 Dynamic Brake Resistors and Brake Modules........32

Engineered Low Voltage Drive Products Sensorless Vector Drives........................................34 Clean Power Drives................................................35 Custom-engineered Drive Solutions.......................36

To order WEB STOCKED items: visit www.BenshawExpress.com

2-1

Standard Low Voltage Drive Products

General Purpose Micro Drives

gx series 1–5 hp, 230 / 460 v, nema 1 / protected chassis RATINGS Constant Torque: 1–5 HP @ 460 V 1–5 HP @ 230 V Chassis VFD converts to NEMA 1 with conduit kit

Product Highlights: The GX series is a compact, economical chassis drive designed for low horsepower applications. The GX series has a powerful set of parameters with a simple, easy to use keypad. The programming structure provides quick, simple setup. Although small in size, the GX series provides a large amount of digital I/O for custom applications.

Key Advantages:

Standard Features:

• Small, compact design

• Standard I/O: 8 digital inputs, 2 analog inputs, 1 analog output, 1 relay output, 1 open collector output

• Constant torque rated • Sensorless vector control or V/Hz control • Standard dynamic braking transistor • Flexible, programmable I/O • Integral PID control • Standard ModBus RTU port • Windows based software

• Digital metering: Output current, output frequency, DC link voltage, motor RPM, output power, output voltage, output torque • Protection: Over current, ground fault, over voltage, current limit, motor overload, output phase loss, over heat, loss of signal, and more • Communications: ModBus RTU (standard) • Voltage tolerance: ±10% • Control methods: Open loop V/Hz, sensorless vector control • V/Hz patterns: Linear, squared, user programmable V/Hz

• Analog inputs: 1 at 0/4 – 20 mA, 1 at 0 – 10 Vdc • Relay output and open collector output: 1 Form C relay output and 1 open collector output, programmable to running, faulted, stopped, ready, at speed, high or low frequency levels, loss of signal, and more • Digital inputs: 8 digital inputs configurable to forward run, reverse run, 3 wire start /stop, reset, jog, preset speeds, motorized pot function, external trip, alternate ramp selections, HOA, and more • User interface: 4 digit LED display • Stop methods: Coast, decel, DC injection braking, and optional dynamic braking

• Analog output functions: 1 analog output 0 – 10 Vdc. Configurable to motor speed, output current, output voltage, DC link voltage.

2-2

To order: call 412-968-0100

Standard Low Voltage Drive Products

General Purpose Micro Drives gx series control terminal layout

LED display

T/M

Description

MO

Multi-function open collector output

MG

MO common

24

24 V power supply (100 mA max.)

P1 P2

Multi-function input terminal (factory setting)

CM

Input signal common

P3 P4 P5 CM P6 P7 P8

RX: Reverse run

BX: Emergency stop Multi-function input terminal (factory setting)

RST: Trip reset

Input signal common Multi-step freq. — Low Multi-function input terminal (factory setting)

Multi-step freq. — Middle Multi-step freq. — High

V1

Freq. setting voltage signal input: -0 – 10 V

I

Freq. setting current signal input: 0 – 20 mA

AM

Multi-function analog output signal: 0 – 10 V

3A

S+ S–

Left/right up/down keys

JOG: Jog operation

10 V power supply for potentiometer

3C

Run/stop buttons

FX: Forward run

VR

3B

Status indicators

Save parameters

Normally open contact Multi-function relay output terminal

Normally closed contact Common

Programmable I/O

Modbus terminal

RS485 communication terminal

To order WEB STOCKED items: visit www.BenshawExpress.com

2-3

Standard Low Voltage Drive Products

General Purpose Micro Drives gx series protected chassis, 1–5 hp, 230 / 460 v 230 V Model Number

 RSI-001-GX-2 •  RSI-002-GX-2 •  RSI-003-GX-2 •  RSI-005-GX-2 •

Constant Torque HP

Variable Torque

Amps

HP

Amps

Dimensions (in.) H

W

D

Weight (lbs.)

1

4.2

-

-

5.0 2.8 5.1 2

2

6.8

-

-

5.0 3.9 5.1 3

3

9.6

-

-

5.0 5.5 6.1 4

5

15.2

-

-

5.0 5.5 6.1 5

460 V Model Number

 RSI-001-GX-4 •  RSI-002-GX-4 •  RSI-003-GX-4 •  RSI-005-GX-4 •

Constant Torque HP

Variable Torque

Amps

HP

Amps

Dimensions (in.) H

W

D

Weight (lbs.)

1

2.1

-

-

5.0 2.8 5.1 2

2

3.4

-

-

5.0 3.9 5.1 3

3

4.8

-

-

5.0 5.5 6.1 4

5

7.6

-

-

5.0 5.5 6.1 5

NEMA 1 CONDUIT KITS  GX-NEMA1KIT-A  GX-NEMA1KIT-B  GX-NEMA1KIT-C

Conduit Kit For 1 HP GX Drive Conduit Kit For 2 HP GX Drive Conduit Kit For 3 HP AND 5 HP GX Drive

REMOTE KEYPAD  VFD-2M-GX-KEYPAD

Remote Mount Keypad and 2 Meter Cable

Units are stocked as protected chassis. If NEMA 1 enclosed is required, add NEMA 1 conduit kit. Conduit kits will need to be installed by customer.  Web stocked •

2-4

To order: call 412-968-0100

Standard Low Voltage Drive Products

Sensorless Vector Drives

sg series variable torque / standard duty / heavy duty RATINGS Variable Torque: 7.5–40 HP @ 230 V 7.5–700 HP @ 460 V 7.5–400 HP @ 600 V Standard Duty: 7.5–40 HP @ 230 V 7.5–600 HP @ 460 V 7.5–400 HP @ 600 V Heavy Duty: 5–30 HP @ 230 V 5–500 HP @ 460 V 5–300 HP @ 600 V

Highlights: The SG series is a compact, economical drive designed for the most demanding applications. The flexible power stack allows the user to apply it to heavy duty loads (150% for 60 secs), standard duty loads (120% for 60 secs), or variable torque loads (110% for 60 secs). With over 250 programmable parameters, Benshaw’s SG series drives are configurable to meet the needs of almost any industrial application, yet remain simple and easy to use.

Key Advantages: • Standard and heavy duty ratings • Integral PID Control • Sensorless vector control or V/Hz control • Integral multiple motor control for pumping applications • Uploadable / downloadable keypad • Flexible, programmable I/O • Economical, compact design • Simple, easy to use LCD interface • Standard ModBus RTU port • Windows-based software

Standard Features: • Standard I/O: 8 digital inputs, 2 analog inputs, 2 analog outputs, 5 relay outputs

• Communications: Modbus RTU (standard). Optional Fieldbus includes DeviceNet, Profibus, BacNet, LonWorks, Modbus TCP

• Optional I/O: Isolated analog output board (adds 2 additional analog outputs, 0/4 – 20 mA)

• Voltage tolerance: -15%, +10%

• Digital metering: Output currents, ground current, output frequency, DC link voltage, motor RPM, output motor voltage, run time, and more

• V/Hz patterns: Linear, squared, user programmable V/Hz

• Protection: Over current, ground fault, over voltage, current limit, motor overload, phase loss, over heat, loss of signal and more • Analog inputs: 1 at 0/4 – 20 mA, 1 at 0 – 10 Vdc (or -10 to 10 Vdc)

• Control methods: V/Hz, sensorless vector, slip compensation

• Analog outputs: 2 at 0 – 10 Vdc (standard), 2 at 0/4 – 20 mA (with option board). Configurable to motor speed, output current, output voltage, DC link voltage, power, PID follower

To order WEB STOCKED items: visit www.BenshawExpress.com

• Relay outputs: 1 Form C fault relay output, 4 Form A relay outputs configurable to running, faulted, ready, at speed, high or low frequency levels, loss of signal, ready, and more • Digital inputs: 8 digital inputs configurable to forward run, reverse run, 3 wire start / stop, reset, jog, preset speeds, motorized pot function, external trip, alternate ramp selections, HOA, and more • User interface: 2 line LCD display, 16 characters per line • Stop methods: Coast, decel, DC injection braking, Flux braking and optional dynamic braking

2-5

Standard Low Voltage Drive Products

Sensorless Vector Drives sg series basic wiring diagram

DB UNIT (option)

MCCB1

MC1

ACR

R S T G

3 Phase AC input

P1P2

24 VDC (50mA max)

24

Default: Speed-L

M1

Default: Speed-M

M2

Default: Speed-H

M3

Default: RST

M4

BX (E-STOP)

M5

Default: JOG

M6

Default: FX

M7

Default: RX

M8 CM

24G

CN1

Sourcing 24G Mode PNP Sinking 24P Mode NPN

M

W Motor

E

Safety stop (600V only)

V1

I

0[V]~+12[V]

Analog input

0/4[mA]~20[mA]

5G

24V 4.9mA

S0

Default: Frequency

Analog meter

S1

Default: Voltage

Max output voltage:12V Source max: 30mA Sink max: 20mA

5G 3A 3C 3B

C1 A2 C2 Aux. relays

A3

Fault relay output 250Vac, 1A

24G

C3

A0

A4

B0

C4

Pulse input method: (A+B), (A) Input freq: 0Hz~100KHz

Terminating resistor

C-

Pulse input

5G

24G

NT

C+ 24G

2-6

V

V1S -12[V]~+12[V]

A1

RS-485

U

U V W E/G

RSi-SG Setting Switch

Relay outputs programmable 250Vac, 1A

N

5G

Motor thermal detection

To order: call 412-968-0100

Standard Low Voltage Drive Products

Sensorless Vector Drives SG Series nema 1 230 V Model Number

 RSI-007-SG-2B  RSI-010-SG-2B  RSI-015-SG-2B  RSI-020-SG-2B  RSI-025-SG-2B  RSI-030-SG-2B  RSI-040-SG-2B

Variable Torque HP

A

Standard Duty HP

A

Heavy Duty HP

A

Dimensions (in.) H

W

D

Weight (lbs.)

7.5 24 7.5 22 5 17 11.2 5.9 6.2 11 10 32 10 29 7.5 23 11.2 7.9 7.2 14 15 46 15 42 10 33 11.2 7.9 7.2 14 20 60 20 55 15 44 17.9 9.8 7.9 28 25 74 25 67 20 54 17.9 9.8 7.9 29 30 88 30 80 25 68 23.6 12 9.2 44 40 115 40 105 30 84 23.6 12 9.2 44

460 V Model Number

 RSI-007-SG-4B  RSI-010-SG-4B  RSI-015-SG-4B  RSI-020-SG-4B  RSI-025-SG-4B  RSI-030-SG-4B  RSI-040-SG-4B  RSI-050-SG-4B  RSI-060-SG-4B  RSI-075-SG-4B  RSI-100-SG-4B  RSI-125-SG-4B  RSI-150-SG-4 • *  RSI-200-SG-4 • *  RSI-250-SG-4 • *  RSI-350-SG-4 • *  RSI-400-SG-4 • *  RSI-500-SG-4 •  RSI-600-SG-4 •  RSI-700-SG-4 •

Variable Torque HP

A

Standard Duty HP

A

Heavy Duty HP

A

Dimensions (in.) H

W

D

Weight (lbs.)

7.5 12 7.5 11 5 8 11.2 5.9 6.2 11 10 16 10 14 7.5 11 11.2 7.9 7.2 14 15 24 15 22 10 17 11.2 7.9 7.2 14 20 30 20 27 15 22 17.9 9.8 7.9 28 25 39 25 35 20 28 17.9 9.8 7.9 29 30 45 30 41 25 34 23.6 12 9.2 44 40 61 40 55 30 44 23.6 12 9.2 44 50 75 50 68 40 55 25.3 12.1 10.5 60 60 91 60 83 50 66 25.3 12.1 10.5 60 75 110 75 100 60 80 25.3 12.1 11.2 64 100 152 100 139 75 111 30.2 14.5 12.1 95 125 183 125 167 100 134 30.2 14.5 12.1 95 150 223 150 204 125 164 30.9 20.1 16.6 225 200 264 200 242 150 194 30.9 20.1 16.6 225 250 325 250 302 200 240 33.9 20.1 16.6 255 350 432 300 396 250 317 42.5 27.2 17.3 450 400 547 400 501 300 401 42.5 27.2 17.3 450 500 613 450 562 350 450 44.9 30.8 17.4 540 600 731 500 670 400 536 51.3 36.3 19.5 840 700 877 600 804 500 643 51.3 36.3 19.5 840

Variable Torque = 110% current for 1 minute / Standard Duty = 120% current for 1 minute / Heavy Duty = 150% current for 1 minute Units ending in a “B” designate NEMA 1. Units not ending in a “B” are protected chassis units. •

Protected chassis only (power terminal covers do not meet NEMA 1).

*

DC Link Reactor (internal)

 Web stocked To order WEB STOCKED items: visit www.BenshawExpress.com

2-7

Standard Low Voltage Drive Products

Sensorless Vector Drives sg series nema 1 / protected chassis 600 V Model Number

 RSI-007-SG-6B  RSI-010-SG-6B  RSI-015-SG-6B  RSI-020-SG-6B  RSI-025-SG-6B  RSI-030-SG-6B  RSI-040-SG-6B  RSI-050-SG-6B  RSI-060-SG-6B  RSI-075-SG-6B  RSI-100-SG-6B  RSI-125-SG-6B  RSI-150-SG-6 • *  RSI-200-SG-6 • *  RSI-250-SG-6 • *  RSI-350-SG-6 • *  RSI-400-SG-6 • *

Variable Torque HP

A

Standard Duty HP

A

Heavy Duty HP

A

Dimensions (in.) H

W

D

Weight (lbs.)

7.5 9 7.5 8.2 5 6.6 14 7.9 7.2 15 10 12 10 11 7.5 9 14 7.9 7.2 16 15 17 15 15.5 10 12 14 7.9 7.2 16 20 23 20 21 15 17 17.9 9.8 7.9 28 25 27 25 24.7 20 19.8 17.9 9.8 7.9 29 30 34 30 31 25 25 23.6 12 9.2 44 40 43 40 39 30 31.5 23.6 12 9.2 44 50 55 50 50 40 43 25.3 11.8 11.5 71 60 64 60 58.6 50 55 25.3 11.8 11.5 71 75 80 75 73 60 64 25.3 11.8 11.5 71 100 104 100 95 75 80 30.2 14.6 13.3 102 125 128 125 117 100 104 30.2 14.6 13.3 102 150 150 150 137 125 128 30.9 20 16.6 225 200 200 200 184 150 147 33.9 20 16.6 255 250 242 250 222 150 177 33.9 20 16.6 255 350 333 300 305 250 244 42.5 27.2 17.7 450 400 424 400 389 300 311 42.5 27.2 17.7 450

Variable Torque = 110% current for 1 minute / Standard Duty = 120% current for 1 minute / Heavy Duty = 150% current for 1 minute Units ending in a “B” designate NEMA 1. Units not ending in a “B” are protected chassis units. •

Protected chassis only (power terminal covers do not meet NEMA 1).

*

DC Link Reactor

 Web stocked

2-8

To order: call 412-968-0100

Standard Low Voltage Drive Products

Sensorless Vector Drives sg series options Dynamic Brake Transistor Modules Catalog Number

Description

VFD-RSI-DBU-020-2

230V Dynamic braking transistor for 1 – 20 HP VFD, 10% duty cycle

VFD-RSI-DBU-030-2

230V Dynamic braking transistor for 25 – 30 HP VFD, 10% duty cycle

VFD-RSI-DBU-050-2

230V Dynamic braking transistor for 40 – 50 HP VFD, 10% duty cycle

VFD-RSI-DBU-020-4

460V Dynamic braking transistor for 1 – 20 HP VFD, 10% duty cycle

VFD-RSI-DBU-030-4

460V Dynamic braking transistor for 25 – 30 HP VFD, 10% duty cycle

VFD-RSI-DBU-050-4

460V Dynamic braking transistor for 40 – 50 HP VFD, 10% duty cycle

VFD-RSI-DBU-075-4

460V Dynamic braking transistor for 60 – 75 HP VFD, 10% duty cycle

VFD-RSI-DBU-100-4

460V Dynamic braking transistor for 100 HP VFD, 10% duty cycle

• For HP greater than 100 HP or duty cycle greater than 10%, consult factory.

Fieldbus Communication Cards Catalog Number

Description

PC-400001-00 Devicenet communication board kit, SG VFD PC-400002-00

Profibus communication board kit, SG VFD

PC-400003-00

LonWorks communication board kit, SG VFD

PC-400004-00

BacNet communication board kit, SG VFD

PC-400005-00

Modbus TCP communication board kit, SG VFD

Display / Keypad Remote Mounting Catalog Number

Description

LCD-100000-00

Replacement display/keypad

VFD-2M-RE-CABLE-SG

2 Meter keypad cable

VFD-3M-RE-CABLE-SG

3 Meter keypad cable

VFD-5M-RE-CABLE-SG

5 Meter keypad cable

VFD-KEYPAD-SG-BEZEL

Bezel, for SG keypad, remote mounting

VFD-KEYPAD-SG-BLANK

Keypad blank, installs in drive when keypad is remote

Analog Output Card Catalog Number

Description

VFD-RSI-SG-4-20-MA

4 - 20 mA Output card, adds (2) 4-20 mA outputs

To order WEB STOCKED items: visit www.BenshawExpress.com

2-9

Built-To-Order, 2 Week Shipment

Packaged Drives

SGP Series standard duty / heavy duty SG Series sensorless vector drive

RATINGS Standard Duty: 7.5–40 HP @ 230 V 7.5–125 HP @ 460 V Heavy Duty: 5–30 HP @ 230 V 5–100 HP @ 460 V

Control power transformer

Input circuit breaker and disconnect

User terminal strip

Bypass contactor

Highlights:

NEMA 12 ventilated enclosure

Benshaw’s Built-To-Order packaged drives meet UL and CE approvals and are available with standard (7.5–125 HP) and heavy duty (5–100 HP) ratings to meet your drive requirements.

Key Advantages:

Standard Features:

Options:

• Standard and heavy duty ratings

• Circuit breaker

• UL and CE approvals

• NEMA 12 ventilated enclosure with fans and filters

• Pre-designed options configurable to your application

• SG Series Sensorless Vector Drive • User terminal strip

• Input line reactor

OPERATING CONDITIONS Operating Temperature: -10–40°C Storage Temperature: -20°C–65°C Humidity: Less than 90% RH max (non-condensing) Altitude: 3,300 ft. max.

2 - 10

• Door mounted keypad • Control power transformer • User input and output power connections

• Disconnect fused or unfused • Output reactor • 3 contactor bypass • Door mounted operator station (6 configurations)

• -10°–40° C operating environment temperature range • -20°–65° C storage temperature

To order: call 412-968-0100

Built-To-Order, 2 Week Shipment

Packaged Drives

SGP Series part number assembler

SGP 005

2

SD

NC

A

3B

1

12

SG Built-To-Order Packaged Drives

Enclosure

Horsepower

Door Mounted Devices

005 = 5 HP

1 = None

007 = 7.5 HP

2 = Start/stop PB, reset PB, HOA switch, speed pot

010 = 10 HP 015 = 15 HP 020 = 20 HP 025 = 25 HP 030 = 30 HP 040 = 40 HP 050 = 50 HP 060 = 60 HP 075 = 75 HP 125 = 125 HP

12 = NEMA 12 V

3 = Option 2 plus power ON, VFD running, VFD fault light 4 = Start/stop PB, fault reset PB, HOA switch, speed pot, jog PB, fwd/rev switch, VFD fault light 5 = VFD/Off/bypass switch, bypass running light 6 = Start/stop PB, reset PB, HOA switch, speed pot, VFD running light, VFD/off/bypass switch, bypass running light

Voltage 2 = 230 V 4 = 460 V

Bypass Type NN = None 3B = 3 Contactor bypass

Duty Type SD = 120% 1 min std duty

Reactor Options

HD = 150% 1 min heavy duty

A = No reactors B = Input reactor

Disconnect Option

C = Output reactor

NC = Non-combination

D = Input and output reactor

CB = Circuit breaker FD = Fusible disconnect CF = Non-fused disconnect IF = Inline fuse

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 11

Built-To-Order, 2 Week Shipment

Packaged Drives

SGP Series standard duty rated 120% O/L for 1 minute 230 Vac, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated Model Number

HP

Dimensions (in.)

A

H

W

D

Weight (lbs.)

SGP0072SDXXXXXX12

7.5

22 30 24 16 90

SGP0102SDXXXXXX12

10

28 30 24 16 93

SGP0152SDXXXXXX12

15

42 36 30 16 99

SGP0202SDXXXXXX12

20

54 36 30 16 104

SGP0252SDXXXXXX12

25

68 36 30 16 110

SGP0302SDXXXXXX12

30

80 36 30 16 148

SGP0402SDXXXXXX12

40

104 36 30 16 158

460 Vac, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated Model Number

HP

Dimensions (in.)

A

H

W

D

Weight (lbs.)

SGP0074SDXXXXXX12

7.5

11 30 24 16 90

SGP0104SDXXXXXX12

10

14 30 24 16 93

SGP0154SDXXXXXX12

15

21 30 24 16 99

SGP0204SDXXXXXX12

20

27 30 24 16 104

SGP0254SDXXXXXX12

25

34 30 24 16 110

SGP0304SDXXXXXX12

30

40 36 30 16 148

SGP0404SDXXXXXX12

40

52 36 30 16 158

SGP0504SDXXXXXX12

50

65 36 30 16 174

SGP0604SDXXXXXX12

60

77 36 30 16 174

SGP0754SDXXXXXX12

75

96 36 30 16 178

SGP1004SDXXXXXX12 *

100

125

46

30

16

259

SGP1254SDXXXXXX12 *

125

156

46

30

16

259

*

Dimensions will increase to 70x30x18 for units with three contactor bypass.



Refer to page 2-11 for Disconnect Options, Reactor Options, Bypass Type, and Door Mounting Devices

2 - 12

To order: call 412-968-0100

Built-To-Order, 2 Week Shipment

Packaged Drives

SGP Series heavy duty rated 150% O/L for 1 minute 230 Vac, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated Model Number

HP

SGP0052HDXXXXXX12

5

A

Dimensions (in.) H

W

D

Weight (lbs.)

17 30 24 16 90

SGP0072HDXXXXXX12

7.5

23 30 24 16 90

SGP0102HDXXXXXX12

10

33 30 24 16 93

SGP0152HDXXXXXX12

15

44 36 30 16 99

SGP0202HDXXXXXX12

20

54 36 30 16 104

SGP0252HDXXXXXX12

25

68 36 30 16 110

SGP0302HDXXXXXX12

30

84 36 30 16 148

460 Vac, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated Model Number

HP

SGP0054HDXXXXXX12

5

SGP0074HDXXXXXX12

7.5

A 8

Dimensions (in.) H

W

D

Weight (lbs.)

30 24 16 90

11 30 24 16 90

SGP0104HDXXXXXX12

10

14 30 24 16 93

SGP0154HDXXXXXX12

15

21 30 24 16 99

SGP0204HDXXXXXX12

20

27 30 24 16 104

SGP0254HDXXXXXX12

25

34 36 30 16 110

SGP0304HDXXXXXX12

30

40 36 30 16 148

SGP0404HDXXXXXX12

40

52 36 30 16 158

SGP0504HDXXXXXX12

50

65 36 30 16 174

SGP0604HDXXXXXX12

60

77 36 30 16 174

SGP0754HDXXXXXX12 *

75

96

46

30

16

178

SGP1004HDXXXXXX12 *

100

125

46

30

16

259

*

Dimensions will increase to 70x30x18 for units with three contactor bypass.



Refer to page 2-11 for Disconnect Options, Reactor Options, Bypass Type, and Door Mounting Devices

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 13

Built-To-Order, 2 Week Shipment

Packaged Drives

SGP Series modular control options Options

CO1 CO2 CO3 CO4 CO5 CO6

Keypad













Start PB













Stop PB













Reset PB













HOA Switch













Speed POT













Run Light













Fault Light











Power On Light











Jog PB











FWD/REV Switch











VFD/OFF Bypass Switch













Bypass Running Light















If selecting a unit with bypass, you must select either option 5 or 6.



Door mounted keypad is standard.

2 - 14

To order: call 412-968-0100

Standard Low Voltage Drive Products

NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series standard duty / heavy duty RATINGS Constant Torque: 1 HP @ 115 V 1–20 HP @ 230 V 1–200 HP @ 460 / 600 V

Highlights: The S4 Series is a line of high performance NEMA 4X washdown / NEMA 12 variable frequency drives. Benshaw’s S4 variable frequency drives are built to withstand the harshest environments and hold up under your most demanding pressure washing applications. All S4 Series drives combine a simple user interface with an array of features and are suited to almost any indoor environment. S4 variable frequency drives come standard with over 180 configurable parameters to match specific application and interface requirements. A standard dynamic braking transistor and resistor are also included for regenerative applications.

Key Advantages: • NEMA 4X IP66 washdown duty enclosure* • Standard braking transistor and resistor • Sensorless vector control • Standard and Heavy Duty ratings • LCD plain English display • Simple, easy-to-use interface • Standard ModBus communication port • Integral PI control

Standard Features: • NEMA 4X IP66 washdown enclosure*

• Control methods: V/Hz, sensorless vector, slip compensation

• Standard I/O: 10 digital inputs, 2 analog inputs, 2 analog outputs, 2 relay outputs, 2 open collector outputs, 1 pulsed output

• V/Hz pattern: Linear, fan and pump, 2-step

• Digital metering: Output current, output voltage, power, MWh meter, run time, power on time, bus voltage, output frequency, and more • Communications: ModBus RTU (standard) • Voltage tolerance: ±10%

• Analog output functions: 1 at 0 – 10 Vdc, 1 at 0 /4-20 mA. Configurable to motor speed, output current, output voltage, DC link voltage, output power, output torque, PID • Analog inputs: 0 – 10 Vdc, 0/4-20 mA, –10 Vdc to 10 Vdc, pulse train input

• Relay outputs: Running, forward, reverse, ready, faulted, at speed, keypad control, adjustable torque levels, adjustable current levels, PID limits, loss of reference, timers • Digital inputs: 10 digital inputs. configurable to run, preset speeds, jogging, PID disable, fault reset, drive enable, timers, motorized pot, and more • User interface: 2 line LCD display, 16 characters per line • Braking functions: Decel, coast, DC injection, dynamic braking (internal IGBT and resistor) * Units 1–100 HP are NEMA 4X. Units 125–200 HP are NEMA 12.

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 15

Standard Low Voltage Drive Products

NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series basic wiring diagram

+24 Vdc

+24

NC2

Forward Run

FWD

RC2

Reverse Run

REV

NO2

Jog

R/J

NC1

Digital Input #1

DI1

RC1

Digital Input #2

DI2

NO1

Digital Input #3

DI3

DO1

Digital Output #1

Digital Input #4

DI4

DO2

Digital Output #2

Digital Input #5

DI5

DOQ

Pulse Train Output

MOL

dcom

Common

EN

dcom

Common

dcom

Imet

4 – 20 mA output

cin+

acom

Analog Common

cin-

Vmet

0 – 10 Vdc Output

+10

acom

Analog Common

External Fault

Enable

Relay #2

Relay #1

4 – 20 mA input

0 – 10 Vdc Input

Vin1

acom

0 – 10 Vdc Input

2 - 16

Vin2

To order: call 412-968-0100

Standard Low Voltage Drive Products

NEMA 4X Washdown Sensorless Vector Drives s4 series

230 V Model Number

 RSI-001-S4-2W  RSI-002-S4-2W  RSI-003-S4-2W  RSI-005-S4-2W  RSI-007-S4-2W  RSI-010-S4-2W  RSI-015-S4-2W  RSI-020-S4-2W  RSI-025-S4-2W

Standard Duty HP 1

Heavy Duty

Dimensions (in.)

Weight (lbs.)

A

HP

A

4.2

0.5

2.5 9.5 6.5 6.1 9

H

W

D

2 6.8 1 4.8 9.5 6.5 6.1 9 3 9.6 2 7.8 9.5 6.5 8.5 9 5 15.2 3 11 12 8.7 6.5 14 7.5 22 5 17.5 12 8.7 6.5 14 10

28

7.5

25.3

17.4

10.8

7.9

30

15 42 10 37.2 17.4 10.8 7.9 30 20

54

15

48.3 20.2 11.3 11.7 50

25

68

20

62.1 20.2 11.3 11.7 50

110 V Input / 230 V Output Model Number

 RSI-001-S4-1SW • •

Standard Duty HP 1

Heavy Duty

Dimensions (in.)

Weight (lbs.)

A

HP

A

4.2

0.5

2.5 9.5 6.5 6.1 9

H

W

D

Single phase 110 V input / 3 phase 230 V output

 Web stocked

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 17

Standard Low Voltage Drive Products

NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series

460 V Model Number

 RSI-001-S4-4W  RSI-002-S4-4W  RSI-003-S4-4W  RSI-005-S4-4W  RSI-007-S4-4W  RSI-010-S4-4W  RSI-015-S4-4W  RSI-020-S4-4W  RSI-025-S4-4W  RSI-030-S4-4W  RSI-040-S4-4W  RSI-050-S4-4W  RSI-060-S4-4W  RSI-075-S4-4W  RSI-100-S4-4W  RSI-125-S4-4D *  RSI-150-S4-4D *  RSI-200-S4-4D *

Standard Duty HP

A

Heavy Duty HP

A

Dimensions (in.) H

W

D

Weight (lbs.)

1

2.1

0.5

1.1 9.5 6.5 6.1 9

2

3.4

1

2.1 9.5 6.5 6.1 9

3

4.8

2

3.4 9.5 6.5 8.5 9

5

7.6

3

4.8

12

8.7

6.5

14

7.5

11

5

7.6

12

8.7

6.5

14

10

14

7.5

11

12

8.7

6.5

14

15

21

10

14

17.4

10.8

7.9

30

20

27

15

21

17.4

10.8

7.9

30

25

34

20

27

17.4

10.8

7.9

30

30

40

25

34

17.4

10.8

7.9

30

40

52

30

40

20.2 11.3 11.7 50

50

65

40

52

20.2 11.3 11.7 50

60

77

50

65

29.4 12.9 13.8 95

75

96

60

77

29.4 12.9 13.8 95

100

124

75

96

29.4 12.9 13.8 95

125

156

100

124

50.5

16.5

18

305

150

180

125

156

50.5

16.5

18

305

200

240

150

180

50.5

16.5

18

305

 Web Stocked *

Units ending in “D” are NEMA 12 and not washdown

2 - 18

To order: call 412-968-0100

Standard Low Voltage Drive Products

NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series

600 V Model Number

Standard Duty HP

A

Heavy Duty

Dimensions (in.)

HP

A

H

W

D

Weight (lbs.)

RSI-001-S4-6W

1

1.7

0.5

0.9

12 8.7 6.5 14

RSI-002-S4-6W

2

2.7

1

1.7

12 8.7 6.5 14

RSI-003-S4-6W

3

3.9

2

2.7

12 8.7 6.5 14

RSI-005-S4-6W

5

6.1

3

3.9

12 8.7 6.5 14

RSI-007-S4-6W

7.5

9

5

6.1

12 8.7 6.5 14

RSI-010-S4-6W

10

11

7.5

9

12 8.7 6.5 14

RSI-015-S4-6W

15

17

10

11

17.4 10.8 7.9

30

RSI-020-S4-6W

20

22

15

17

17.4 10.8 7.9

30

RSI-025-S4-6W

25

27

20

22

17.4 10.8 7.9

30

RSI-030-S4-6W

30

32

25

27

17.4 10.8 7.9

30

RSI-040-S4-6W

40

41

30

32

20.2 11.3 11.7 50

RSI-050-S4-6W

50

52

40

41

20.2 11.3 11.7 50

RSI-060-S4-6W

60

68

50

52

29.4 12.9 13.8 95

RSI-075-S4-6W

75

82

60

62

29.4 12.9 13.8 95

RSI-100-S4-6W

100

107

75

77

29.4 12.9 13.8 95

RSI-125-S4-6D *

125

125

100

99

50.5

16.5

18

305

RSI-150-S4-6D *

150

144

125

125

50.5

16.5

18

305

RSI-200-S4-6D *

200

192

150

140

50.5

16.5

18

305

*

Units ending in “D” are NEMA 12 and not washdown

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 19

Standard Low Voltage Drive Products

NEMA 4X Washdown / NEMA 12 Sensorless Vector Drives s4 series options Display / Keypad Remote Mounting Options Catalog Number

Description

VFD-S4-REMOTE-KEYPAD-KIT

Includes remote keypad, interface board and 2M cable

VFD-XBLANKKPS0

Keypad blank, size 0 & 2, installs in drive when keypad is remote

VFD-XBLANKKPS1

Keypad blank, size 1, installs in drive when keypad is remote

VFD-XBLANKKPS3

Keypad blank, size 3, 4 and 5, installs in drrive when keypad is remote

VFD-S4-100FT-REMOTEKIT-A

100 foot remote display Kit, 30 HP and below

VFD-S4-100FT-REMOTEKIT-B

100 foot remote display Kit, 40 HP and above

Display / Keypad Replacement Catalog Number

Description

LCD-S4KEYPADS0R

Replacement keypad/display, S4 VFD, size 0 and 2

LCD-S4KEYPADS1R

Replacement keypad/display, S4 VFD, size 1

VFD-RSI-S4-REMOTEKEYPAD

Replacement keypad/display, for frame size 3, 4, and 5 and remote

Drive Mounting Options Catalog Number

Description

BRKT-100646-00

Fins out mounting bracket, 40 HP, 50 HP (frame size 3)

BRKT-100645-00

Fins out mounting bracket, 60 HP, 75 HP and 100 HP (frame size 4)

BRKT-100134-03

Fins out mounting bracket, 125 HP, 150 HP and 200 HP (frame size 5)

2 - 20

To order: call 412-968-0100

Standard Low Voltage Drive Options

Input Line Reactors 3% impedance

230 V Model Number



HP

A

Dimensions (in.)

Weight (lbs.)

Open

Enclosed (NEMA 1)

REA-KDRA25L

REA-KDRA25L-C1

1

4.6 6.5 8 6 8

REA-KDRA27L

REA-KDRA27L-C1

2

7.5 6.5 8 6 8

REA-KDRA28L

REA-KDRA28L-C1

3

10.6 6.5 8 6 8

REA-KDRB22L

REA-KDRB22L-C1

5

16.7 6.5 8 6 12

REA-KDRB23L

REA-KDRB23L-C2

7.5

24.2 7.5 10 7 14

H

W

D

REA-KDRD25L

REA-KDRD25L-C2

10

30.8 7.5 10 7 18

REA-KDRD24L

REA-KDRD24L-C2

15

46.2 7.5 10 7 18

REA-KDRD26L

REA-KDRD26L-C2

20

59.4 7.5 10 7 18

REA-KDRC22L

REA-KDRC22L-C2

25

74.8 7.5 10 7 21

REA-KDRF24L

REA-KDRF24L-C4

30

88 15.5 15 13 65

REA-KDRF25L

REA-KDRF25L-C4

40

114 15.5 15 13 65

Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 21

Standard Low Voltage Drive Options

Input Line Reactors 3% impedance

480 V Model Number



HP

Dimensions (in.)

A

Weight (lbs.)

Open

Enclosed (NEMA 1)

REA-KDRA8L

REA-KDRA8L-C1

1

2.1 6.5 8 6 8

REA-KDRA1L

REA-KDRA1L-C1

2

3.4 6.5 8 6 8

REA-KDRA2L

REA-KDRA2L-C1

3

4.8 6.5 8 6 8

REA-KDRA3L

REA-KDRA3L-C1

5

7.6 6.5 8 6 8

REA-KDRA4L

REA-KDRA4L-C1

7.5

11 6.5 8 6 8

REA-KDRA5L

REA-KDRA5L-C1

10

14 6.5 8 6 9

REA-KDRB2L

REA-KDRB2L-C1

15

21 6.5 8 6 12

REA-KDRB1L

REA-KDRB1L-C1

20

27 6.5 8 6 12

REA-KDRD1L

REA-KDRD1L-C2

25

34 7.5 10 7 16

REA-KDRD2L

REA-KDRD2L-C2

30

40 7.5 10 7 16

H

W

D

REA-KDRC1L

REA-KDRC1L-C2

40

52 7.5 10 7 21

REA-KDRF2L

REA-KDRF2L-C3

50

65 9 12 8 37

REA-KDRF4L

REA-KDRF4L-C3

60

77 9 12 8 42

REA-KDRF3L

REA-KDRF3L-C4

75

96 15.5 15 13 65

REA-KDRH3L

REA-KDRH3L-C4

100

124 15.5 15 13 65

REA-KDRH2L

REA-KDRH2L-C4

125

156 15.5 15 13 75

REA-KDRH1L

REA-KDRH1L-C4

150

180 15.5 15 13 75

REA-KDRG3L

REA-KDRG3L-C4

200

240 15.5 15 13 100

REA-KDRG1L

REA-KDRG1L-C4

250

302 15.5 15 13 100

REA-KDRG2L

REA-KDRG2L-C4

300

361 15.5 15 13 100

REA-KDRJ2L

REA-KDRJ2L-C5

350

414 18.5 20 16 120

REA-KDRJ1L

REA-KDRJ1L-C5

400

477 18.5 20 16 120

REA-KDRL2L

REA-KDRL2L-C5

500

590 18.5 20 16 160

REA-KDRL3L

REA-KDRL3L-C5

600

720 18.5 20 16 205

REA-KDRS1L

REA-KDRS1L-C7

700

840

36 28.5 30.3 318

Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

2 - 22

To order: call 412-968-0100

Standard Low Voltage Drive Options

Input Line Reactors 3% impedance

600 V Model Number



HP

A

Dimensions (in.)

Weight (lbs.)

Open

Enclosed (NEMA 1)

REA-KDRA50L

REA-KDRA50L-C1

1

1.7 6.5 8 6 8

REA-KDRA46L

REA-KDRA46L-C1

2

2.7 6.5 8 6 8

REA-KDRA52L

REA-KDRA52L-C1

3

3.9 6.5 8 6 8

REA-KDRA47L

REA-KDRA47L-C1

5

6.1 6.5 8 6 8

REA-KDRA48L

REA-KDRA48L-C1

7.5

9 6.5 8 6 8

REA-KDRA49L

REA-KDRA49L-C1

10

11 6.5 8 6 9

REA-KDRB45L

REA-KDRB45L-C1

15

17 6.5 8 6 12

REA-KDRB44L

REA-KDRB44L-C1

20

22 6.5 8 6 12

REA-KDRB43L

REA-KDRB43L-C1

25

27 6.5 8 6 12

REA-KDRD42L

REA-KDRD42L-C2

30

32 7.5 10 7 18

H

W

D

REA-KDRC43L

REA-KDRC43-C2

40

41 7.5 10 7 21

REA-KDRC44L

REA-KDRC44L-C2

50

52 7.5 10 7 21

REA-KDRF46L

REA-KDRF46L-C3

60

62 9 12 8 42

REA-KDRF47L

REA-KDRF47L-C3

75

77 9 12 8 42

REA-KDRF45L

REA-KDRF45L-C4

100

99 15.5 15 13 65

REA-KDRH43L

REA-KDRH43L-C4

125

125 15.5 15 13 80

REA-KDRH44L

REA-KDRH44L-C4

150

144 15.5 15 13 80

REA-KDRI42L

REA-KDRI42L-C4

200

192 15.5 15 13 85

REA-KDRG47L

REA-KDRG47L-C4

250

242 15.5 15 13 100

REA-KDRG45L

REA-KDRG45L-C4

300

289 15.5 15 13 100

REA-KDRJ45L

REA-KDRJ45L-C5

350

336 18.5 20 16 120

REA-KDRJ43L

REA-KDRJ43L-C5

400

382 18.5 20 16 120

Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 23

Standard Low Voltage Drive Options

Input Line Reactors 5% impedance

240 V Model Number



HP

A

Dimensions (in.)

Weight (lbs.)

Open

Enclosed (NEMA 1)

REA-KDRA25H

REA-KDRA25H-C1

1

REA-KDRA26H

REA-KDRA26H-C1

2

7.5 6.5 8 6 8

REA-KDRA28H

REA-KDRA28H-C1

3

10.6 6.5 8 6 8

REA-KDRB25H

REA-KDRB25H-C1

5

16.7 6.5 8 6 12

H

W

D

4.6 6.5 8 6 8

REA-KDRB26H

REA-KDRB26H-C1

7.5 24.2 6.5 8 6 12

REA-KDRD21H

REA-KDRD21H-C2

10

30.8 7.5 10 7 18

REA-KDRD22H

REA-KDRD22H-C2

15

46.2 7.5 10 7 18

REA-KDRC22H

REA-KDRC22H-C2

20

59.4 7.5 10 7 21

REA-KDRF28H

REA-KDRF28H-C3

25

74.8 9 12 8 42

REA-KDRF25H

REA-KDRF25H-C4

30

88 15.5 15 13 65

REA-KDRF26H

REA-KDRF26H-C4

40

114 15.5 15 13 65

Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

2 - 24

To order: call 412-968-0100

Standard Low Voltage Drive Options

Input Line Reactors 5% impedance

480 V Model Number



HP

A

Dimensions (in.)

Weight (lbs.)

Open

Enclosed (NEMA 1)

REA-KDRA8H

REA-KDRA8H-C1

1

2.1 6.5 8 6 8

REA-KDRA1H

REA-KDRA1H-C1

2

3.4 6.5 8 6 8

REA-KDRA2H

REA-KDRA2H-C1

3

4.8 6.5 8 6 8

REA-KDRA3H

REA-KDRA3H-C1

5

7.6 6.5 8 6 8

REA-KDRA4H

REA-KDRA4H-C1

7.5

11 6.5 8 6 9

REA-KDRA5H

REA-KDRA5H-C1

10

14 6.5 8 6 9

REA-KDRB2H

REA-KDRB2H-C1

15

21 6.5 8 6 11

REA-KDRC3H

REA-KDRC3H-C1

20

27 6.5 8 6 19

REA-KDRC1H

REA-KDRC1H-C2

25

34 7.5 10 7 21

H

W

D

REA-KDRE2H

REA-KDRE2H-C2

30

40 7.5 10 7 22

REA-KDRF4H

REA-KDRF4H-C3

40

52 9 12 8 37

REA-KDRF1H

REA-KDRF1H-C3

50

65 9 12 8 37

REA-KDRF2H

REA-KDRF2H-C3

60

77 9 12 8 37

REA-KDRH2H

REA-KDRH2H-C4

75

96 15.5 15 13 80

REA-KDRI2H

REA-KDRI2H-C4

100

124 15.5 15 13 87

REA-KDRG3H

REA-KDRG3H-C4

125

156 15.5 15 13 90

REA-KDRG1H

REA-KDRG1H-C4

150

180 15.5 15 13 90

REA-KDRJ1H

REA-KDRJ1H-C5

200

240 18.5 20 16 120

REA-KDRL1H

REA-KDRL1H-C5

250

302 18.5 20 16 160

REA-KDRL2H

REA-KDRL2H-C5

300

361 18.5 20 16 145

REA-KDRL3H

REA-KDRL3H-C5

350

414 18.5 20 16 150

REA-KDRL4H

REA-KDRL4H-C5

400

477 18.5 20 16 160

REA-KDRL6H

REA-KDRL6H-C5

500

590 18.5 20 16 170

REA-KDRS1H

REA-KDRS1H-C7

600

720

36 28.5 30.3 420

REA-KDRS2H

REA-KDRS2H-C7

700

840

36 28.5 30.3 420

Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 25

Standard Low Voltage Drive Options

Input Line Reactors 5% impedance

600 V Model Number



HP

A

Dimensions (in.)

Weight (lbs.)

Open

Enclosed (NEMA 1)

REA-KDRA50H

REA-KDRA50H-C1

1

1.7 6.5 8 6 8

REA-KDRA43H

REA-KDRA43H-C1

2

2.7 6.5 8 6 8

REA-KDRA44H

REA-KDRA44H-C1

3

3.9 6.5 8 6 8

REA-KDRA45H

REA-KDRA45H-C1

5

6.1 6.5 8 6 8

REA-KDRB42H

REA-KDRB42H-C2

7.5

9 7.5 10 7 14

H

W

D

REA-KDRB43H

REA-KDRB43H-C2

10

11 7.5 10 7 14

REA-KDRB44H

REA-KDRB44H-C2

15

17 7.5 10 7 14

REA-KDRD41H

REA-KDRD41H-C2

20

22 7.5 10 7 18

REA-KDRC43H

REA-KDRC43H-C2

25

27 7.5 10 7 21

REA-KDRE42H

REA-KDRE42H-C2

30

32 7.5 10 7 22

REA-KDRF44H

REA-KDRF44H-C3

40

41 9 12 8 42

REA-KDRF45H

REA-KDRF45H-C3

50

52 9 12 8 42

REA-KDRH43H

REA-KDRH43H-C4

60

62 15.5 15 13 80

REA-KDRH42H

REA-KDRH42H-C4

75

77 15.5 15 13 80

REA-KDRI41H

REA-KDRI41H-C4

100

99 15.5 15 13 85

REA-KDRG44H

REA-KDRG44H-C4

125

125 15.5 15 13 100

REA-KDRG45H

REA-KDRG45H-C4

150

144 15.5 15 13 100

REA-KDRJ41H

REA-KDRJ41H-C5

200

192 18.5 20 16 120

REA-KDRL46H

REA-KDRL46H-C5

250

242 18.5 20 16 160

REA-KDRL47H

REA-KDRL47H-C5

300

289 18.5 20 16 160

REA-KDRL48H

REA-KDRL48H-C5

350

336 18.5 20 16 160

REA-KDRL49H

REA-KDRL49H-C5

400

382 18.5 20 16 160

Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems. They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

2 - 26

To order: call 412-968-0100

Standard Low Voltage Drive Options

Output Reactors 1.5% impedance

480 V Model Number



HP

A

Dimensions (in.)

Weight (lbs.)

Open

Enclosed (NEMA 1)

REA-KDRA1P

REA-KDRA1P-C1

2

3.4 8 6.5 8 6

REA-KDRA2P

REA-KDRA2P-C1

3

4.8 8 6.5 8 6

REA-KDRA3P

REA-KDRA3P-C1

5

7.6 8 6.5 8 6

REA-KDRA4P

REA-KDRA4P-C1

7.5

11

REA-KDRB1P

REA-KDRB1P-C1

10

14 11 6.5 8 6

REA-KDRD1P

REA-KDRD1P-C2

15

21

16 7.5 10 7

REA-KDRD2P

REA-KDRD2P-C2

20

27

16 7.5 10 7

REA-KDRD3P

REA-KDRD3P-C2

25

34

18 7.5 10 7

REA-KDRD4P

REA-KDRD4P-C2

30

40

18 7.5 10 7

REA-KDRC1P

REA-KDRC1P-C2

40

52

21 7.5 10 7

REA-KDRF1P

REA-KDRF1P-C3

50

65 37 9 12 8

REA-KDRF2P

REA-KDRF2P-C3

60

77 37 9 12 8

REA-KDRF3P

REA-KDRF3P-C4

75

96

65 15.5 15 13

H

W

D

9 6.5 8 6

REA-KDRH1P

REA-KDRH1P-C4

100

124

75 15.5 15 13

REA-KDRI1P

REA-KDRI1P-C4

125

156

85 15.5 15 13

REA-KDRI2P

REA-KDRI2P-C4

150

180

90 15.5 15 13

REA-KDRG1P

REA-KDRG1P-C4

200

240

95 15.5 15 13

REA-KDRJ1P

REA-KDRJ1P-C5

250

302 120 18.5 20 16

REA-KDRJ2P

REA-KDRJ2P-C5

300

361 120 18.5 20 16

REA-KDRL1P

REA-KDRL1P-C5

350

414 135 18.5 20 16

REA-KDRL2P

REA-KDRL2P-C5

400

477 145 18.5 20 16

REA-KDRL3P

REA-KDRL3P-C5

450

515 150 18.5 20 16

REA-KDRL4P

REA-KDRL4P-C5

500

590 150 18.5 20 16

230 V drives/motors can operate with extended lead lengths (500 ft. or involves multiple motors from one drive, use an appropiately sized (current) 480 V reactor or a long lead fillter.

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 27

Standard Low Voltage Drive Options

Output Reactors 1.5% impedance

600 V Model Number

HP

Dimensions (in.)

A

Weight (lbs.)

Open

Enclosed (NEMA 1)

REA-KDRA31P

REA-KDRA31P-C1

2

2.7 8 6.5 8 6

REA-KDRA35P

REA-KDRA35P-C1

3

3.9 8 6.5 8 6

REA-KDRA33P

REA-KDRA33P-C1

5

6.1 8 6.5 8 6

REA-KDRA34P

REA-KDRA34P-C1

7.5

9

9 6.5 8 6

REA-KDRA36P

REA-KDRA36P-C1

10

11

9 6.5 8 6

H

W

D

REA-KDRD31P

REA-KDRD31P-C2

15

17

16 7.5 10 7

REA-KDRD32P

REA-KDRD32P-C2

20

22

16 7.5 10 7

REA-KDRD35P

REA-KDRD35P-C2

25

27

16 7.5 10 7

REA-KDRD33P

REA-KDRD33P-C2

30

32

18 7.5 10 7

REA-KDRD34P

REA-KDRD34P-C2

40

41

18 7.5 10 7

REA-KDRC31P

REA-KDRC31P-C2

50

52

21 7.5 10 7

REA-KDRF31P

REA-KDRF31P-C3

60

62 37 9 12 8

REA-KDRF32P

REA-KDRF32P-C3

75

77 37 9 12 8

REA-KDRF33P

REA-KDRF33P-C4

100

99

65 15.5 15 13

REA-KDRH31P

REA-KDRH31P-C4

125

125

75 15.5 15 13

REA-KDRI31P

REA-KDRI31P-C4

150

144

85 15.5 15 13

REA-KDRI32P

REA-KDRI32P-C4

200

192

90 15.5 15 13

REA-KDRG31P

REA-KDRG31P-C4

250

242

95 15.5 15 13

REA-KDRJ31P

REA-KDRJ31P-C5

300

289 120 18.5 20 16

REA-KDRJ32P

REA-KDRJ32P-C5

350

336 120 18.5 20 16

REA-KDRL31P

REA-KDRL31P-C5

400

382 135 18.5 20 16

2 - 28

To order: call 412-968-0100

Standard Low Voltage Drive Options

Long Lead Filters (DV/DT) 240 V

Dimensions (in.)

Model Number



HP

A

H (in.)W Dimensions

D Weight (lbs.)

Open

Enclosed (NEMA 1)

FLTR-V1K3A00

FLTR-V1K3A01

0.5

3

9 5.5 10 11

FLTR-V1K4A00

FLTR-V1K4A01

0.75

4

9 5.5 10 11

H

W

D

FLTR-V1K6A00

FLTR-V1K6A01

1~1.5

6

9 5.5 10 11

FLTR-V1K8A00

FLTR-V1K8A01

2

8

9 5.5 10 11

FLTR-V1K12A00

FLTR-V1K12A01

3

12

9 5.5 10 11

FLTR-V1K16A00

FLTR-V1K16A01

5

16

9 5.5 10 15

FLTR-V1K25A00

FLTR-V1K25A01

7.5

25

9 5.5 10 15

FLTR-V1K35A00

FLTR-V1K35A01

10

35

12 8 11.5 23

FLTR-V1K45A00

FLTR-V1K45A01

15

45

12 8 11.5 23

FLTR-V1K55A00

FLTR-V1K55A01

20

55

12 8 11.5 23

FLTR-V1K80A00

FLTR-V1K80A01

25~30

80

12 8 11.5 29

FLTR-V1K110A00

FLTR-V1K110A01

40

110 16.5 18 15 68

Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet. Long lead filters protect the motor from high DV/DT.

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 29

Standard Low Voltage Drive Options

Long Lead Filters (DV/DT) 480 V

Dimensions (in.)

Model Number



HP

A

H (in.)W Dimensions

D Weight (lbs.)

Open

Enclosed (NEMA 1)

FLTR-V1K2A00

FLTR-V1K2A01

0.75

2

9 5.5 10 11

FLTR-V1K3A00

FLTR-V1K3A01

1~1.5

3

9 5.5 10 11

H

W

D

FLTR-V1K4A00

FLTR-V1K4A01

2

4

9 5.5 10 11

FLTR-V1K6A00

FLTR-V1K6A01

3

6

9 5.5 10 11

FLTR-V1K8A00

FLTR-V1K8A01

5

8

9 5.5 10 11

FLTR-V1K12A00

FLTR-V1K12A01

7.5

12

9 5.5 10 11

FLTR-V1K16A00

FLTR-V1K16A01

10

16

9 5.5 10 15

FLTR-V1K18A00

FLTR-V1K18A01

10

18

9 5.5 10 15

FLTR-V1K21A00

FLTR-V1K21A01

15

21

9 5.5 10 15

FLTR-V1K25A00

FLTR-V1K25A01

15

25

9 5.5 10 15

FLTR-V1K27A00

FLTR-V1K27A01

20

27

9 5.5 10 15

FLTR-V1K35A00

FLTR-V1K35A01

25

35

12 8 11.5 23

FLTR-V1K45A00

FLTR-V1K45A01

30

45

12 8 11.5 23

FLTR-V1K55A00

FLTR-V1K55A01

40

55

12 8 11.5 23

FLTR-V1K80A00

FLTR-V1K80A01

50~60

80

12 8 11.5 29

FLTR-V1K110A00

FLTR-V1K110A01

75

110 16.5 18 15 68

FLTR-V1K130A00

FLTR-V1K130A01

100

130 16.5 18 15 83

FLTR-V1K160A00

FLTR-V1K160A01

125

160 16.5 18 15 83

FLTR-V1K200A00

FLTR-V1K200A01

150

200 16.5 18 15 93

FLTR-V1K250A00

FLTR-V1K250A01

200

250 16.5 18 15 93

FLTR-V1K305A00

FLTR-V1K305A01

250

305 16.5 18 30 117

FLTR-V1K362A00

FLTR-V1K362A01

300

362 16.5 18 30 117

FLTR-V1K420A00

FLTR-V1K420A01

350

420 16.5 18 30 132

FLTR-V1K480A00

FLTR-V1K480A01

400

480 16.5 18 30 138

FLTR-V1K600A00

FLTR-V1K600A01

500

600 16.5 18 30 168

FLTR-V1K750A00

FLTR-V1K750A01

600

750 16.5 18 30 180

Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet. Long lead filters protect the motor from high DV/DT.

2 - 30

To order: call 412-968-0100

Standard Low Voltage Drive Options

Long Lead Filters (DV/DT) 600 V

Dimensions (in.)

Model Number



HP

A

H (in.)W Dimensions

D Weight (lbs.)

Open

Enclosed (NEMA 1)

FLTR-V1K2A00

FLTR-V1K2A01

1

2

9 5.5 10 11

FLTR-V1K3A00

FLTR-V1K3A01

2

3

9 5.5 10 11

H

W

D

FLTR-V1K4A00

FLTR-V1K4A01

3

4

9 5.5 10 11

FLTR-V1K8A00

FLTR-V1K8A01

5

8

9 5.5 10 11

FLTR-V1K12A00

FLTR-V1K12A01

10

12

9 5.5 10 11

FLTR-V1K18A00

FLTR-V1K18A01

15

18

9 5.5 10 15

FLTR-V1K25A00

FLTR-V1K25A01

20

25

9 5.5 10 15

FLTR-V1K27A00

FLTR-V1K27A01

25

27

9 5.5 10 15

FLTR-V1K35A00

FLTR-V1K35A01

30

35

12 8 11.5 23

FLTR-V1K45A00

FLTR-V1K45A01

40

45

12 8 11.5 23

FLTR-V1K55A00

FLTR-V1K55A01

50

55

12 8 11.5 23

FLTR-V1K80A00

FLTR-V1K80A01

75

80

12 8 11.5 29

FLTR-V1K110A00

FLTR-V1K110A01

100

110 16.5 18 15 68

FLTR-V1K130A00

FLTR-V1K130A01

125

130 16.5 18 15 83

FLTR-V1K160A00

FLTR-V1K160A01

150

160 16.5 18 15 83

FLTR-V1K200A00

FLTR-V1K200A01

200

200 16.5 18 15 933

FLTR-V1K250A00

FLTR-V1K250A01

250

250 16.5 18 15 93

FLTR-V1K305A00

FLTR-V1K305A01

300

305 16.5 18 30 117

FLTR-V1K362A00

FLTR-V1K362A01

350

362 16.5 18 30 117

FLTR-V1K420A00

FLTR-V1K420A01

450

420 16.5 18 30 132

Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet. Long lead filters protect the motor from high DV/DT.

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 31

Standard Low Voltage Drive Options

Dynamic Brake Resistors and Brake Modules Dynamic brake resistors and modules are used to address over voltage conditions with drives. Over voltage trips occur when the DC bus in the drive increases to the over voltage trip level. This increase in voltage occurs when the mechanical energy in the motor is converted into regenerative electrical energy, which is transferred back into the drive (the motor acts like a generator). Regeneration occurs when: • The deceleration time is too quick. • The load has high inertia and keeps rotating after the drive output power has decreased below that of the load. (Ex: fly wheels, large fans) • The load is an over hauling load, cyclical or periodic. (Ex: pump jack, punch press) • When the motor suddenly becomes unloaded. (Ex: lumber mill saw applications) Regeneration can occur on an occasional basis or periodically (cyclical) depending on the type of load. A dynamic brake module and resistor are required to be added to the drive to dissipate this excess power. The module and resistor must be sized correctly depending on the application. Contact Benshaw for assistance with sizing brake resistors and brake modules.

2 - 32

To order: call 412-968-0100

Engineered Low Voltage Drive Packages overview Benshaw is a recognized industry leader in the shipment of engineered drives from our state-of-the-art factory, with dedicated engineering teams and a complete inventory of components necessary to build engineered solutions for you. Select the enclosure, disconnect, bypass, pilot devices, control strategy and filters required to meet your most demanding applications.

Control Modifications — Whatever you specify • Pilot devices, control power transformers, switches, meters, relays, space heaters, protective devices, PLCs, etc.

Combination Drive Packages — To meet your requirements • Circuit breaker protection • Non-fused disconnect protection • Fusible disconnect protection • Flange or rotary handle mechanism

Bypass Packages — To fit your application • Two contactor • Three contactor • Reduced voltage solid state starters

Enclosures — To Match your environment • Standard designs — NEMA 1, 12, 3R • Custom enclosures • Special enclosures — 4, 4X, air conditioned • Motor control centers

Filters — For your unique application • Line reactors 3% and 5% • Long lead filters • Load reactors • Harmonic filters • 18 pulse systems

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 33

Engineered Low Voltage Drive Products

Sensorless Vector Drives engineered packages part number assembler

RSI

060

SG

4

NC

A

01

VFD

Enclosure

RSI = Redistart Inverter

01=NEMA 1 12=NEMA 12 04=NEMA 4

Horsepower 001 = 1 HP

060 = 60 HP

3R=NEMA 3R

002 = 2 HP

075 = 75 HP

1A=NEMA 12 ventilated

003 = 3 HP

100 = 100 HP

005 = 5 HP

125 = 125 HP

Package Type

007 = 7.5 HP

150 = 150 HP

A = Packaged drive

010 = 10 HP

200 = 200 HP

015 = 15 HP

250 = 250 HP

B = Packaged drive with two contactor bypass

020 = 20 HP

300 = 300 HP

025 = 25 HP

400 = 400 HP

030 = 30 HP

500 = 500 HP

040 = 40 HP

600 = 600 HP

050 = 50 HP

700 = 700 HP

VFD Series

C = Packaged drive with three contactor bypass Disconnect Options Options NC = Non-combination CB = Circuit breaker FD = Fusible disconnect

SG = Sensorless Vector Drive S4 = Washdown Sensorless Vector Drive Voltage 2 = 230 V 4 = 460 V 6 = 600 V

2 - 34

To order: call 412-968-0100

Engineered Low Voltage Drive Products

Clean Power Drives sg 519 series IEEE-519 Compliant RATINGS Variable Torque: 7.5–700 HP @ 460 V 7.5–400 HP @ 600 V+ Standard Duty: 7.5–600 HP @ 460 V 7.5–400 HP @ 600 V+ Heavy Duty: 5–500 HP @ 460 V 5–300 HP @ 600 V+

Product Highlights:

Standard features:

Benshaw’s SG 519 Series drives are designed and manufactured to limit voltage and current distortion levels to within the levels defined by IEEE-519*. This eliminates the need for expensive, time consuming harmonic analysis and avoids the resonance problems associated with inefficient harmonic filters.

• UL listed

Our municipal projects and engineering team will work with you to configure a clean power solution that meets your specifications and requirements. Modular design The modular design of Benshaw’s SG 519 Series drives eliminates maintenance problems inherent in older drive designs and improves drive reliability by significantly reducing power module part counts. This design approach also allows each drive unit to be customtailored to your specific requirements. Optional bypass

• Limits voltage and current harmonics to IEEE-519* levels • Addresses poor power factor • Eliminates expensive harmonic analysis • Avoids resonance problems associated with inefficient harmonic filters • Prevents overloading of circuit breakers, feeders and transformers • Run from motor/generator systems • NEMA 1, 12V, 3R, 4 or 4X enclosures available, plus custom configurations

An optional bypass design configuration (ATL or RVSS) is available for SG 519 drive packages when mission critical reliability is important and disruptive downtime cannot be tolerated. * IEEE-519, 1992 Table 10-2 and Table 10-3. + Consult factory, not UL listed.

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 35

Custom-engineered drive solutions.

Whether you need simple modifications made to one of Benshaw’s standard drive packages, a custom engineered, application-specific drive package or a turnkey drive solution, Benshaw can help. With engineering experience and complete motor control system production capabilities, Benshaw delivers all of the competence, convenience and value you’d expect from a leader in engineered control systems. Whatever your motor control needs may be, Benshaw’s engineering teams and application specialists can help you find a cost-effective, reliable solution.

Quality assurance testing Benshaw’s assembly teams perform a preliminary quality assurance inspection before delivery is made. Drive assemblies undergo a variety of testing procedures, including motor operation testing, load testing, control circuit testing, wire pull testing, electrical performance checks, mechanical alignment inspection, torque measurement and user interface/ pilot device functionality. All test processes meet or exceed ISO 9001 requirements, and all tests are documented and archived for quality verification.

2 - 36

To order: call 412-968-0100

For any drive application. In any configuration.

Enclosures

Control modifications

• Standard NEMA 1, 12 and 3R enclosure designs • Custom enclosures

Over 250 control modifications and accessories are available from Benshaw, including:

• NEMA 4, 4X, air conditioned and other special enclosures

• Pilot devices • Control power transformers

• Motor control centers

• Switches

• Combination drive packages

• Meters

• 15–2,000 A circuit breakers

• Relays

• 40–2,000 A non-fused disconnects

• Space heaters

• 30–800 A fusible disconnects

• PLCs

• Flange or rotary handle mechanisms

• Protective devices

Bypass packages • Two contactor • Three contactor • Reduced voltage solid state starters Filters • Line reactors (3% and 5%) • Long lead filters • Passive harmonic filters • 18 pulse systems (IEEE-519)

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 37

Integrated control solutions using both Benshaw

Systems integration is a central focus of our business, and a competitive advantage for our customers Benshaw’s success in the OEM and industrial marketplace is a direct result of our willingness as a company to think “beyond the box”. We’ve made systems integration a central focus of our business, and we make learning your business a top priority. By focusing on the bigger picture we gain a better understanding of your process, your control requirements, and your market objectives. We then apply that knowledge toward the development and production of complete, costeffective, fully integrated control solutions.

2 - 38

Customized enclosures Benshaw takes great pride in our ability to design and deliver custom control enclosures that truly complement the form and function of your machine. NEMA 1, 12, 3R, 4 and 4X enclosures in unit mount, console mount, free-standing and wallmount configurations are available to suit your needs. Every enclosure we design is carefully crafted to meet your dimensional requirements, prototyped and tested for fit and compliance with relevant safety standards, fabricated to exacting tolerances and finished to your paint specification.

To order: call 412-968-0100

and additional brands.

Intelligent motor controls

Integrated control sensors

Benshaw offers a full range of intelligent, programmable, low and medium voltage starters and drives—from fractional to 20,000 HP—to meet a variety of motor control needs.

Benshaw can integrate any number of sensors, transducers, relays, switches, meters and protective devices, as required, to precisely monitor and respond to all critical process, machine or environmental variables.

Motor control products include full voltage starters, solid state reduced voltage starters and variable frequency drives. Reversing, two-speed, DC braking, wye-delta, synchronous and wound rotor control are supported.

Integrated machine logic Benshaw can supply standard or PC-based programmable logiccontrollers, and will custom design hardware or software to meet process requirements. Networking capabilities, remote monitoring and custom designed human machine interface packages are also available.

Integrated power packages Benshaw can also incorporate all of the power distribution components needed for your machine in one simple, plug-and-play package. Turnkey power distribution packages typically include all internal and external motor control wiring harnesses, power wiring harnesses, motor/machine sensor connections, and, if needed, a fully integrated power factor correction unit.

Typical OEM/Industrial applications • Air and process compressors • Blowers and air handling equipment • Chillers • Conveyors • Food/liquid processing equipment • Industrial refrigeration equipment • Municipal waste/water handling machines • Pumps • Pipelines • Shredders/grinders • Specialty machinery • Transfer lines

All power systems are factory tested at Benshaw with custombuilt machine simulators and wire pull-testers to guarantee reliable performance.

To order WEB STOCKED items: visit www.BenshawExpress.com

2 - 39

2 - 40

To order: call 412-968-0100

Medium Voltage Starters Standard Medium Voltage Starter Products MX3 Controller...........................................................2 Solid State Starters..................................................4

Engineered Medium Voltage Starter Products Combination Solid State Starters...........................11 Smart Full Voltage ATL Starters..............................15 Full Voltage ATL Starters.........................................18 Main Lug Only.........................................................20 Load Interrupter Switch..........................................23 Wound Rotor Starters.............................................25 Synchronous Starters.............................................26 Mechanical Packaging Options..............................27 Turnkey Solutions...................................................28

Engineered Medium Voltage Starter Options Pilot Devices...........................................................30 Control Options.......................................................32 Motor Protection Relays.........................................34 Enclosure Options...................................................35 Power Factor Correction Capacitors.......................36 Surge / Lighting Arrestors.......................................38 Surge Capacitors....................................................39 Line Reactors..........................................................40 Documentation.......................................................41 To order WEB STOCKED items: visit www.BenshawExpress.com

3-1

Standard Medium Voltage Starter Products

Next Generation Intelligent Motor Control mx3 controller

KEYPAD (INCLUDED)

OPTIONAL RTD MODULES

Highlights:

Key Features:

Next generation MX technology forms the backbone of Benshaw’s entire line of intelligent medium voltage motor controls. With fiber optic firing, enhanced programming capabilities, ease of use, and a unique, flexible architecture—Benshaw’s MX3 controller delivers unprecedented functionality and all of the rugged, dependable performance you’ve come to expect from a world leader in solid state motor controls and drives. 3

MX3 controllers, power components, software and sensors are all designed, built and tested to perform as an integrated control system, eliminating the coordination and performance problems inherent in other forms of reduced voltage starting. With more built-in features, more configurable options, greater expandability and a broader communications capability than any other motor control on the market, Benshaw’s next generation MX3 technology will shorten your commissioning times, improve motor performance and protection, enhance diagnostic capability and streamline many electrical system monitoring and maintenance tasks. 3-2

FIBER OPTIC FIRING • Integrated technology • Noise immunity • High voltage isolation • Safe, reliable SCR control

• High performance motor control with multiple starting modes built-in • Flexible, programmable I/O • Integrated motor protection • Line and motor metering • Diagnostic capabilities with event log and real-time clock • Built-in remote self-testing (BIST) • Expanded communications capabilities • Intelligent SCR power poles • Intelligent MV MCC integration

To order: call 412-968-0100

Standard Medium Voltage Starter Products

Next Generation Intelligent Motor Control mx3 controller control features Multiple Starting Modes:

• Control power low

• Voltage ramp

• Stack over temperature

• Current ramp

• Motor PTC input

- Adjustable initial current

• RTD modules

- Adjustable maximum current - Adjustable ramp time • Torque ramp (TruTorque) - Adjustable initial torque - Adjustable maximum torque

Metering: • Accuracy: - 3% out-of-box - 2% factory calibrated • Average current • L1 current

- Adjustable ramp time

• L2 current

• Power ramp

• L3 current

- Adjustable initial torque

• Current imbalance %

- Adjustable maximum torque

• Ground fault current

- Adjustable ramp time

• L1 – L2 voltage

• Linear/tach feedback control

• L2 – L3 voltage

Motor Protection: • Motor thermal overload • Independent starting and running OL’s

• Average volts

• L3 – L1 voltage • Overload % • Power factor • Watts

• Up to speed timer exceeded

• VA

• Low line voltage

• KW hours

• Low line frequency

• MW hours

• High line frequency

• Phase order

• Phase reversal

• Line frequency

• Phase loss

• Analog input

• Instantaneous overcurrent

• Analog output

• Overcurrent

• Run time — days

• Undercurrent

• Run time — hours

• Current imbalance

• # of starts

• Ground fault (residual or zero sequence)

• Tru Torque %

• Shorted or open SCR • Disconnect fault • Inline contactor fault

• VARS

8 Digital Inputs Configurable to: • Stop • Fault

1 Analog 4 – 20 mA / 0 – 10 Vdc Input Configurable to: • Trip high level

• Fault reset

• Trip low level

• Bypass / inline confirm

1 Analog 4 – 20 mA / 0 – 10 Vdc Output Configurable to:

• OL reset • Local/remote selection • Heater enable

• Current (0 – 200%/0 – 800%)

• Heater disable

• Voltage (0 – 150%)

• Dual ramp selection

• OL (0 – 150%)

• 1 dedicated start input

• kW (0 – 10 kW/0 – 100 kW)

• Disconnect

• MW (0 – 1 MW)

• Slow speed

• Analog input (0 – 100%)

• Brake enable

• Firing (0 – 100%)

• Brake disable

• Calibration

6 Relay Outputs Configurable to:

User Interface:

• Faulted • Running • Up to speed • Alarm condition • Ready condition • Locked out • Over current

• Event log (99 events) • Door mounted LCD display - Set/examine operating parameters - View status information, line current, voltage and frequency

• Under current

- Start and stop the solid state starter

• OL alarm

1 Communication Port:

• Shunt trip

• ModBus / RS485

• Ground fault • Energy saver indication • Heating indication • Cooling fan

• Power % • Peak starting current

Advanced Functionality: • Dual ramp selection • Adjustable kick current • Programmable decel modes • MV BIST test (built-in self test)

• Last starting duration • RTD temperatures • Real-time clock

To order WEB STOCKED items: visit www.BenshawExpress.com

3-3

Standard Medium Voltage Starter Products

Prepackaged Solid State Starters

MVRXE SERIES emergency atl bypass, severe duty, load break fusible disconnect

Highlights: The Benshaw Medium Voltage Starter is a microprocessor controlled solid state reduced voltage starter for three phase induction motors. The starter provides a closed-loop current ramp for smooth stepless motor acceleration. Supplied in a free standing enclosure. Enclosures are available in NEMA 12 or NEMA 3R configurations. The medium voltage enclosure consists of two distinct compartments. The medium voltage or power pole section is located in the main body of the enclosure, whereas the low voltage section containing the control logic is located behind the door as an isolated compartment. Each starter is supplied with a load break isolation switch, Class “R” motor fuses, inline vacuum contactor, solid state power poles, and a vacuum bypass contactor, which is used to bypass the SCR power poles once the motor is up to full speed. The logic control incorporates the MX3 computer that has all the circuitry required to drive the power semiconductors, which are located in the power section. MVRXE starters provide solid state reduced voltage starting for normal operation and full voltage emergency back-up starting, with complete electronic motor protection at the flip of a switch.

Key Advantages:

This unique redundant design is ideal for critical applications where downtime is extremely disruptive and cannot be tolerated.

• Service entrance labeled (optional)

MX3 solid state controls provide precise digital starting and stopping, motor protection, metering, diagnostics and communications, standard.

• Solid state reduced voltage starting — normal operations

• NEMA 12, UL 347 listed • 45 kV BIL • Built-in self test (BIST) features for “quick commissioning”

• 425 A load break • Switch selectable emergency backup full voltage starter • MX3-embedded digital control • Fiber optic firing • Advanced motor protection • Advanced metering • Power quality protection • Diagnostics and ModBus RTU485 communications standard

3-4

To order: call 412-968-0100

Standard Medium Voltage Starter Products

Prepackaged Solid State Starters

MVRXE SERIES emergency atl bypass, severe duty, load break fusible disconnect

Standard Features: • NEMA 12, solid state starter, UL347 listed, Class E-2 • 45 kV BIL • 200 MVA (2300 Vac)/350 MVA (4160 Vac) short circuit fault rated. • 500% – 30 seconds rated solid state starter — UL347 certified and listed. • 8,000 PIV — UL347 certified and listed at 2.4kV • 12,000 PIV — UL347 certified and listed at 4.2kV • Fiber optic firing

• 425 A load break, 5 kV rated disconnect switch, with viewing window, grounding assembly and lockable handle mechanism. Mechanically interlocked for safety. • Fixed mounted, start duty rated vacuum contactors for isolation and SCR bypass, wired for normal bypass operation and full voltage start operation, with (2) N/O and (2) N/C auxiliary contacts. • Separately mounted “SPE” series electronic overload device has the following standard features:

• Selectable solid state or emergency full voltage operation via selector switch mounted inside of LV compartment

- Class 10 – 30 adjustable

• Load matched Class R fusing with blown fuse indication

- Phase reversal protection

- Phase imbalance protection - 1 NO/1 NC trip contact - “Trip free” design - Phase loss protection

Benshaw MVRXE vs. any autotransformer starter Motor Control & Protection Functions

Any Auto Transformer

Benshaw MVRXE

Soft Start

YES

YES

Soft Stop

NO

YES

Full Voltage Bypass Starting

NO

YES

Load Break Disconnect Switch

NO

YES

Built-In Self Test

NO

YES

UL 347/Service Entrance Rated (Optional)

NO

YES

3 Year Warranty

NO

YES

Plain English Digital Display

NO

YES

Electronic OL Protection

NO

YES

Electronic Power Quality

NO

YES

Digital Metering

NO

YES

Embedded Plain English Diagnostics

NO

YES

Embeded RS485

NO

YES

Incoming Line Landing Pad

NO

YES

Integrated Control & Protection

NO

YES

UL Zero Sequence Ground Fault *

NO

YES

To order WEB STOCKED items: visit www.BenshawExpress.com

• Built-in self test (BIST) features for “quick commissioning” • 120 Vac, 1000 VA CPT with primary and secondary fusing, with 500 VA available for customer use • Door-mounted start and stop push-buttons. • Door-mounted LCD keypad • Door-mounted run indication light • Door-mounted local-off-remote switch • Door-mounted reset button • Terminal strip mounted inside LV compartment for: - Remote start/stop control - Remote up-to-speed indication - Remote run indication - Remote fault indication • Benshaw MX3 controller with complete soft start, soft stop and motor protection capabilities • 485 communications capabilities —  local through door connection or remote from starter (optional) • ModBus communications standard

* Optional ground fault CT required

3-5

Standard Medium Voltage Starter Products

Prepackaged Solid State Starters

MVRXE SERIES emergency atl bypass, severe duty, load break fusible disconnect MVRXE12—2300 V Model Number

HP

A

 MVRXE12-650-2300-**  MVRXE12-750-2300-**  MVRXE12-1500-2300-**

650

Dimensions (in.)

Weight (lbs.)

H

W

D

160

92

36

32

1,800

750

180

92

36

32

1,800

1500

360

92

36

32

1,800

Model Number

HP

A

 MVRXE18-1000-4160-**  MVRXE18-1500-4160-**  MVRXE18-3000-4160-**

1000 133 92 36 32 2,000

MVRXE18—4160 V



Dimensions (in.) H

W

D

Weight (lbs.)

1500 200 92 36 32 2,000 3000 360 92 36 32 2,000

Starters are top entry / bottom exit — top exit available upon request. Dimensions and weights are approximate.

** Insert appropriate option code as shown: NEMA 12 = 12 / NEMA 3R = 3R

 Web stocked NOTE: Power fuses ship loose. Please provide motor full load amps at time of order for proper fuse sizing.

Modular Options Catalog Number

Description

 A171  A008  A406  A407  A408 *

SPACE HEATER WITH THERMOSTAT (INCLUDED IN NEMA 3R OPTION) Description E-STOP PUSH-BUTTON, MUSHROOM HEAD, RED



TOP LEFT OR TOP RIGHT MOUNTING, ACCOMODATES STRESS CONES

8 CHANNEL RTD MODULE, 100 OHM PLATINUM (ALSO AVAILABLE FOR REMOTE MOUNTING) 16 CHANNEL RTD MODULE(S), 100 OHM PLATINUM (ALSO AVAILABLE FOR REMOTE MOUNTING) TOP HAT ENCLOSURE MODULE FOR TOP ENTRY (18”H X 30”W X 20”D),

 A409 SERVICE ENTRANCE LABELED  A106 ADDITIONAL 1000VA CONTROL POWER TRANSFORMER •

The MVRXE series was designed as an integrated package. Listed above are the available modular options. For systems requiring more extensive requirements, please refer to the engineered section of the MV catalog.

*

Top hat will ship loose for customer installation.

## Built-to-order: Please allow 2 weeks for shipment of complete MVRXE unit when ordering these options to a stock starter.

Protective Relay Options Catalog Number

Description

A875

GROUND FAULT CT, 2000:1, 4.0:DIA. (FOR MX3 USE)

A876

GROUND FAULT CT, 2000:1, 8.13:DIA. (FOR MX3 USE)

3-6

To order: call 412-968-0100

Built-To Order, 2 Week Shipment

Solid State Reduced Voltage Starters 4,160 Volt MVRMX Series 0–1,500 HP or 1,501–3,000 HP

Highlights: Benshaw has analyzed and value engineered our MV SSRV Engineered-To-Order product options, and developed a modular architecture, to offer those options most ordered on a Built-To-Order program. This has enabled us to offer you a customized product with a reduced lead time. Our goal is to optimize our response to meet your mission critical application needs. The RediStart CFMVRMX series with MX3 technology is a fully integrated, programmable family of Class E2 load break/combination solid state starters. This integrated design includes control and power electronics, bypass and isolation contactors that reduce maintenance and operating costs when compared to other methods.

Key Advantages: Protect machinery from failure and excessive maintenance caused by mechanical shock during starting or stopping. The RediStart MVRMX provides smooth, stepless acceleration and controlled deceleration.

Power Section Features: Description

Specification

Starting Method

Closed Loop Current Control Ramp Torque Ramp Power Ramp (kW) Voltage Ramp Linear Accel/Tach Feedback

Protect electrical systems from disruptive voltage drops and power outages caused by motor locked rotor inrush current. The RediStart MVRMX starter precisely controls the current ramp during start up.

Power Ratings

Reference Table A (next page)

Control Input

120 Vac or Dry Contact, 2 or 3 Wire

Standard Insulation Test

2X RATED V + 2,000 V

Nominal Voltage Ratings

4.16 kV

Ambient Temperature

0 – 40° C to 3,300 ft.

Protect mission critical motors from failure or unscheduled outages caused by machine or electrical system faults. The RediStart MVRMX starter provides complete, high performance, coordinated line monitoring, motor control and protection.

Frequency Range

23–72 Hz on Control Board

Overall Efficiency (W/Bypass)

99.5%

Metering Functions

47 Parameters

Relay Outputs

24 Functions

Over/Under Voltage Protection

10 to 30%

Power Loss (W/Bypass)