CHANGING OF INVERTER TYPE IN SPARE PART RMIO BOARD ABB Oy Drives 3AFE00470793 00470793.DOC Dept. Date Made by Chec
Views 140 Downloads 8 File size 23KB
CHANGING OF INVERTER TYPE IN SPARE PART RMIO BOARD
ABB Oy Drives
3AFE00470793 00470793.DOC
Dept.
Date
Made by
Checked / Accepted by
Revision
Page
EJC
22.10.2007
Anu Lindholm
Osmo Pasuri
C
1/2
Changing of inverter type in spare part RMIO board • standard software version ASXR7310 / AS7R7292 and later versions 1. Background The loading package of Standard Application is divided to two different HW related packages: AS7R7xxx and ASXR73xx The ASXR73xx package supports only types R2-R8 in products of ACS800-01, -02, -04, -07. The AS7R7xxx package supports only types R2i-R8i, nxR8i in products of ACS800-07, -11, -17, -31, -37, 104, -107 and ACS800LC Detailed list of software compatibility and the latest software versions in production can be found from following tables: ACS 800 Software Compatibility : http://search.abb.com/library/ABBLibrary.asp?DocumentID=3AFE64638211&LanguageCode=en&Docume ntPartId=1&Action=Launch ACS 800 Program Versions in Production : http://search.abb.com/library/ABBLibrary.asp?DocumentID=3AFE64810651&LanguageCode=en&Docume ntPartId=1&Action=Launch 2. Supported spare part inverter types All inverter types for spare part RMIO board are in 17 parameters. Each parameter contains one logical group of inverters. E.g. parameter 112.20 INV RECNF STD 200 includes 200 V standard drive series inverter types (SRxxxx_y). ASXR7xxx-type series: 112.20 INV RECNF STD 200 112.21 INV RECNF STD 400 (exl. parallel types) 112.22 INV RECNF STD 500 (exl. parallel types) 112.23 INV RECNF STD 690 (exl. parallel types)
-------------------------------------------------------------STD stands for standard series MD stands for multidrive hardware 811 meaning ACS800-11 hardware 817 meaning ACS800-17 hardware LC means water cooled hardware.
AS7R7xxx-type series: 112.21 INV RECNF STD 400 (exl. single types) 112.22 INV RECNF STD 500 (exl. single types) 112.23 INV RECNF STD 690 (exl. single types) 112.24 INV RECNF MD 400 112.25 INV RECNF MD 500 112.26 INV RECNF MD 690 112.27 INV RECNF 811 200 112.28 INV RECNF 811 400 112.29 INV RECNF 811 500 112.30 INV RECNF 811 690 112.31 INV RECNF 817 400 112.32 INV RECNF 817 500 112.33 INV RECNF 817 690 112.34 INV RECNF LC 400 112.35 INV RECNF LC 500 112.36 INV RECNF LC 690
___________________________________________________________________________
CHANGING OF INVERTER TYPE IN SPARE PART RMIO BOARD
ABB Oy Drives
3AFE00470793 00470793.DOC
Dept.
Date
Made by
Checked / Accepted by
Revision
Page
EJC
22.10.2007
Anu Lindholm
Osmo Pasuri
C
2/2
From AS7R7322 inverter types are divided in two groups. Both are available in the same DOS loading package, but require separate DriveWindow backup packages (XRNONE and LXNONE). When software is downloaded with DOS, only the inverter types in the same inverter group are downloaded and available in reconfiguration. The inverter group division is as follows: •
ACS800 Multi Drive, Air Cooled
XRNONE
400V Single Drive, parallel
2...4xR8
SR0610_3 … SR1850_3
500V Single Drive, parallel
2...4xR8
SR0760_5 … SR2310_5
690V Single Drive, parallel
2...6xR8
SR0750_7 … SR3490_7
400V MultiDrive
R2-R5, R6i...R8i, 2...6xR8i
NR0003_3 …NR3080_3
500V MultiDrive
R2-R5, R6i...R8i, 2...6xR8i
NR0004_5… NR3640_5
690V MultiDrive
R4-R5, R6i-R8i, 2...12xR8i
NR0011_7 … NR6970_7
230…690V ACS800-11/31
R5 – R6
MR0011_2 … MR0100_7
400-690V ACS800-17/37,
R7i, R8i+R8i,
MR0140_3 … MR3310_7
2...6xR8i + 2...6xR8i
•
•
ACS800 Multi Drive, Liquid Cooled LXNONE 400-690V Liquid Cooled
R8i, 2...10xR8i
LS0390_3 … LS6620_7
400-690V Liquid Cooled
R7i – R8i, 2...10xR8i
LC0120_3 … LC6620_7
ACS600 Drives (as before) XFNONE All ACS600 inverter types SFxxxx_y-, NFxxxx_y- and MFxxxx_y-inverter types
3. Other changes •
Parameter 112.06 INVERTER RECONFIG, where all the inverter types were previously, has been removed.
•
Inverter type selection texts can now be seen also on different DriveTools windows. Previously only selected number which was describing inverter type was displayed.
•
In new version XXNONE type values are downloaded automatically before the requested type. Previously XXNONE type had to be first and after that a required inverter type. If XXNONE loading was not done before loading new type, all inverter configuration parameters were not changed to new values.
•
In new version 102.1 PARAM LOCK is not needed to open if reconfigure parameter is changed using a DriveTool.
4. Inverter type changing procedure for RMIO boards having XXNONE, XRNONE or LXNONE type downloaded a. b. c.
Set 16.03 PASS CODE to 564. This opens parameter groups 112 and 190. Select inverter type from parameters 112.20- 112.36 Make a power down for RMIO card.
___________________________________________________________________________