10095 El Dwg 001 Cover Page

3 5 4 6 7 8 9 10 11 12 13 14 15 16 A A PROJECT INFORMATION B NAME ADDRESS 497.7 kW (DC) PHOTOVOLTAIC

Views 72 Downloads 0 File size 476KB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

Citation preview

3

5

4

6

7

8

9

10

11

12

13

14

15

16

A

A

PROJECT INFORMATION

B

NAME ADDRESS

497.7 kW (DC) PHOTOVOLTAIC SYSTEM

:- H T MEDIA :- PLOT No.8,

B

CONSISTING OF (1580) 315Wp MODULES 497.7 kW PROJECT IN HT MEDIA

UDYOGVIHAR, GREATER NOIDA COORDINATES

:- Lat 28.50°,Lon 77.47°

C

C

D

D

E

E

F

F

G

G

PROJECT NOTES :-

APPLICABLE STANDARDS:-

1

THIS DESIGN DOCUMENT EXPLAINS THE TECHNICAL DETAILS OF 497.7 kW PHOTOVOLTAIC SYSTEM INSTALLED OVER THE ROOFTOP OF HT MEDIA

1.

DESIGNING OF THE SOLAR PV PLANT IS IN ACCORDANCE WITH THE ELECTRICAL STANDARDS NATIONAL ELECTRIC CODE (NEC:-ARTICLE-690) BOOK.

2.

THE LOCATION OF THE INTER-CONNECTION POINT IS IN THE MAIN LT PANEL 7B UNDER SESSION 1

2.

OTHER INTERNATIONAL STANDARDS ARE IEC-61724, IEC-61727, IEC-60364, IEC-61277, IEC-61836, IEC-61725, IEC-62446, IEC-62548, IEC-62093, IEC-60364-7-712, IEEE-1547, ETC.

H

3.

ALL MATERIALS, WORKMANSHIP AND CONSTRUCTION FOR THE SITE IMPROVEMENTS SHOWN SHALL BE IN ACCORDANCE WITH CURRENT PREVAILING MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, STANDARDS AND REQUIREMENTS.

4.

3.

THE INDIVIDUAL EQUIPMENTS USED IN THE PV PLANT ARE IN ACCORDANCE WITH THE FOLLOWING. SOLAR PANELS:

ALL INFORMATION SHOWN MUST BE VERIFIED PRIOR TO USE FOR CONSTRUCTION ACTIVITIES.

I

5.

SOLAR INVERTER:

REFER TO THE SUPPLIER INSTALLATION MANUAL WHEN INSTALLING MOUNTING HARDWARE ON THE ROOF.

CABLES: SWITCH, CONNECTOR & ENCLOSURES: GROUNDING & LIGHTNING: DATA MONITORING:MOUNTING STRUCTURE:CIVIL WORKS:-

NOTE: THE DRAWINGS OF THIS DRAWING SET IS THE PROPERTY OF AMPLUS SOLAR POWER PVT. LTD. COPYING OR REUSE OF THIS DRAWING WITHOUT PERMISSION IS PROHIBITED.

J

H

IEC-61215/IS-14286, IEC-61701, IEC-61730, DIN-E N 62176. IEC-61683, IEC-62109-1, IEC - 62116, IEC-61727, IEC-60068-2,27,30,75,78 ETC. IEC-60189, IS-694, IS-1554, IS-7098-1,2-PFG-1169. IS/IEC-60947, IP65/67, IEC-62208, IEC- 529, EN-50521. IS-3043, NFC-17-102. IEC-61724. IS-875, IS-4759, IS-2062. IS- 456, IS-800.

I

J

INSTALLATION WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL THE CODES, REGULATIONS AND LAWS AS REQUIRED BY THE COUNTRY AND STATE. INSTALLATION WORK SHALL ALSO COMPLY IEC-62124, IEC-62548, IEC-60364-7-712, IEC-60364-4-41.

K

RELEASE STATUS

K

DATE

PRELIMINARY FOR TENDER ONLY FOR CONSTRUCTION

AMPLUS SOLAR POWER PRIVATE LIMITED

ARCHITECTURAL

ISSUED FOR REVIEW MECH.

INST.

ELEC.

STRL.

VS

JK

A

02.11.2016

ARCH.

APPROV.

NATURE OF REVISION & DESCRIPTION

CHECKED

DRAWN

REV.

REVIEWED

L

CIVIL & STRUCTURAL

02.11.2016

ELECTRICAL

6TH FLOOR,THE PALM SQUARE,SEC.-66, GOLF COURSE EX.ROAD, GURGAON - 122102

JK

DRAWN :

INSTRUMENTATION MECHANICAL

DATE

2

3

4

5

6

7

CHECKED :

VS

APPROVED :

VS

VS

SCALE: NONE DATE:07-11-2016 JOB NO. 10095

10095-EL-DWG- 001

REVIEWED 1

JK

REVIEWED :

8

9

10

11

12

13

14

15

16

L