10 QUESTIONS FOR ELECTRICAL SAFETY ELECTRICAL SAFETY: RECOGNIZING HAZARDS ASSOCIATED WITH THE USE OF ELECTRICAL ENERGY
Views 140 Downloads 5 File size 309KB
10 QUESTIONS
FOR ELECTRICAL SAFETY
ELECTRICAL SAFETY: RECOGNIZING HAZARDS ASSOCIATED WITH THE USE OF ELECTRICAL ENERGY AND TAKING PRECAUTIONS SO THAT HAZARDS DO NOT CAUSE INJURY OR DEATH.
1
6
PRE-JOB BRIEFING
4 Are all essential team members including onsite contractor
TEST BEFORE TOUCH
4 Has the isolation been tested to verify absence of voltage?
and subcontractors present at the pre-job meeting? Does everyone understand:
1.8
4 Has the test device been verified? 4 Has Earthing (Grounding) been applied, where required?
the hazards their roles & responsibilities, what to do if an incident occurs
2
PLANNING & PROCEDURES
7
PERMIT
PTW
4 Does the job have clear and complete:
4 Are physical barriers, protective equipment, special tools and other controls to prevent harm to personnel in place?
JHA
Scope
BARRIERS & GUARDING
Location
CAUTION - DO NOT ENTER
Electrical Safety Procedures
CAUTION - DO NOT ENTER
Permit to Work controls Mitigation measures?
3
8
COMPETENCY & AUTHORIZATION
4 Are all team members competent and authorised to carry out
PERSONAL PROTECTIVE EQUIPMENT
4 Is the appropriate level of PPE used to minimize exposure to
Qualification
shock and arc flash hazards?
the assigned electrical work?
4 Is the condition of the PPE acceptable for use?
4 Has signed authorisation been obtained for switching, testing and work on electrical systems?
4
9
EQUIPMENT ISOLATION
4 Is it possible to make contact with underground cables or
4 Has all electrical equipment been de-energised and isolated,
overhead power lines?
in line with Electrical Safety Rules and Procedures?
4 Are adequate controls in place to avoid contact?
4 Have remote methods been considered?
5
10
LOCK OUT – TAG OUT
PORTABLE ELECTRICAL EQUIPMENT
4 Has temporary and portable electrical equipment been
4 Have locks and tags been installed at electrical isolation points in accordance with Safe Isolation (LOTO) procedures?
4 Are tags properly filled-in and substantial, weatherproof
UNDERGROUND & OVERHEAD POWER LINES
LY RICAL ELECT TED A ISOL DANGER
and secure?
Visit the operational safety (GET) intranet site for additional resources: http://sww.shell.com/hse/safety/operational/index.html
inspected and approved prior to use?
4 Are portable power tools and personal devices inspected
and approved for the area classification?
REVISION 5: 10 AUG 2015
10 QUESTIONS FOR ELECTRICAL SAFETY
ELECTRICAL SAFETY: RECOGNIZING HAZARDS ASSOCIATED WITH THE USE OF ELECTRICAL ENERGY AND TAKING PRECAUTIONS SO THAT HAZARDS DO NOT CAUSE INJURY OR DEATH.