01. 2019 - Hisense VRF General Catalogue

To Know Hisense GLOBAL NETWORK Hisense Group, headquartered in eastern China, is an international conglomerate founded

Views 499 Downloads 19 File size 12MB

Report DMCA / Copyright

DOWNLOAD FILE

Recommend stories

Citation preview

To Know Hisense

GLOBAL NETWORK

Hisense Group, headquartered in eastern China, is an international conglomerate founded in 1969 mainly focusing on white goods and electronics. In the past several years, Hisense has held the record of being the 3rd most popular TV brand worldwide and the 2nd most popular VRF brand in China respectively. Over decades, we’ve dedicated ourselves to the technological innovation, quality assurance and integrated service delivery. In the upcoming 2019, with the collaboration of R&D centers, branch offices and service centers all around the world, Hisense VRF firmly hold confidence in providing excellent user experience and service to our values clients globally.

INDUSTRIAL MODULES

Real Estate High-end Plaza Chains Mould Design and Manufacturing Business Finance

TV and Display Devices Internet TV Operation Mobile Communication Devices Optical Communication Devices Chip

Real Estate and Modern Services

Multimedia

SPORTS MARKETING

IT Smart Systems

Household Appliances

Smart City Smart Community Smart Transportation Smart Business Medical Electronic Devices Smart Home System and Service

Refrigerator Freezer Air-conditioner Washing Machine Kitchen Appliance

HIGH-EFFICIENCY AND ENERGY-SAVING

What is Hisense VRF Hisense VRF is produced by Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd., jointly invested by Hisense Group and Hitachi Air Conditioning(changed to Johnson Hitachi in 2015) for air-conditioning manufacturing, technology development, marketing and service. The strict quality control system is the trustworthy guarantee of Hisense VRF. From designing, manufacturing to testing, Hisense VRF insists on abiding by the highest standard to keep high quality. Computer Simulation Development---The Most Advanced and Energy Saving Development Mode Excellence-led Manufacture Mode---Efficiency and Energy Saving Strict Quality Control and Component Test---High Quality, High Efficiency and Low Energy Consumption

KEY FEATURES AND BENEFITS 003 008 012 017 019

High Efficiency High Reliability Best Comfort More Flexibility Design More Flexibility Installation and Maintenance

PRODUCT LINE 027

Hi-FLEXi S Series

043

Hi-FLEXi G+ Series

CONTROL SYSTEM

057

Hi-FLEXi X Series

127

065

Hi-FLEXi R Series

127

075

Hi-FLEXi W Series Heat Recovery

128

083

Hi-Smart H Series

131

025

Why Choose Hisense VRF?

089

Outdoor Unit

124

Wired Controller Wireless Controller Receiver Kit for Wireless Control-optional Centralized Controller Building Management System

Air to Water Heat Pump

089

Hi-AquaSmart Series

093

MULTI-FUNCTION Series

More Space Saving​

OPTIONAL PARTS

Easier Transportation and Installation

141

High Technology and Outstanding Operation Performance

099

Comprehensive Product Lineup

113

Modular Combination Design Gives Greater Flexibility

Intelligent Control System

Indoor Unit ​Ventilation Solution​

137

Support Optional Parts

Key Features and Benefits High Efficiency High Reliability Best Comfort More Flexibility Design More Flexibility Installation and Maintenance

03/04

HIGH EFFICIENCY

Key Features and Benefits

New Generation of Enhanced Vapor Injection Scroll Compressor Hisense Hi-FLEXi S Series adopts a new generation of the high efficiency scroll compressor and the patented vapor injection technology*1. It can greatly enhance the heating performance and achieve high energy-saving efficiency. Powerful heating is guaranteed by Hi-FLEXi S Series, especially under low temperature with heating performance increased up to 25%, compared with the standard model. Note:*1. Patent number: a heat exchange cycle system and control methods and air conditioning, 201610909006.X

New Suction Structure Increase efficiency at high speed and stability under large capacity. Release Valve Increase efficiency by reducing compression loss especially for medium and low capacity conditions.

Anti-overcompression Technique Hisense high pressure chamber scroll compressor adopts patented Release Valve Technique, which effectively prevents the overcompression when compressor is in partial load operation and drastically promotes the intermediate pressure performance. ○Orbiting Scroll Lifting Force Optimization is improved ○Leakage Loss Reduction ○Improved Intermediate Pressure Performance

Injection Valve Heating performance improvement under partial load conditions by injection valve. New Scroll Shape High efficiency by asymmetric scroll shape. Compliant Frame Mechanism High performance technology by reduce leakage loss and friction loss. Featured Discharge System High reliability due to minimum oil loss at any condtion due to refrigerant flow out from center of compressor. Oil Equalization Mechanism Capacity can be enlarged by plural compressors and oil balance between plural compressors. High Efficiency Motor High efficiency by rare earth magnet and special designed motor. Oil Seperation High reliability by keeping oil in the compressor by this separation plate. High Reliability Oil Supply System Oil supply system using pressure difference without any problem even at low speed or partial load condition. PVE Oil Using PVE oil ensuring a high reliable and long life.

The Latest Dual FOC 180° Sine Wave DC Variable Speed Drive Technology The inverter adopts double FOC 180° vector sine wave drive algorithm to drive the compressor motor in dual mode, and possesses various protective functions against over current, over voltage, under voltage, short circuit, modules and heat sinks temperatures, power phase loss, bus voltage fluctuations and communication failures to ensure the efficiency and reliability.

30°

120°

120°

Exclusive Asymmetric Scroll

Current

60°

120°

Square Wave Voltage

Time

The asymmetric scroll structure effectively reduces refrigerant gas leakage during suction and compression and enhances operation efficiency and reliability.

Conventional Control Mode

Inside Chamber Pi=Ps Achieve Suction

Current

180°

180° Square Wave

Voltage

Time

Reduce Suction Loss and Leakage Loss High Efficiency

Outside Chamber Po>Pi During Compression

180° Sine Wave DC Inverter-Driven Technique

05/06

HIGH EFFICIENCY

Key Features and Benefits

Precise Capacity-output Control

Stepped Fins

The inverter technique combined with elaborate control algorithm ensures responsive capacity-output adjustment based on real-time indoor load, which reduces temperature fluctuation and provides coziness.

Load%

Previous fins

The latest developed fins

Load% Capacity Output Indoor Load

Capacity Output Indoor Load

Φ9.53 Overlapping section surface of fins

Hisense Precise Inverter Control

Time(h)

Conventional Inverter Control

Thick

Time(h)

Wind direction

Φ7.0

Thin

Overlapping section surface of fins

Wind direction

Hierarchical diagram of hydrophilic aluminum foil

Stepless Fan-speed Control

Lubricating layer Hydrophilic coating Corrosion-resistant coating

The BLDC motor equipped in outdoor unit can realize stepless fan-speed adjustment to ensure system efficiency and stability.

Fin

● Not easy to frost in heating mode; ● Slow down the corrosion of heat exchanger by corrosive gases; ● Destroying the surface tension of water droplets accelerates the down flow speed of defrost water or condensate water and improves the air conditioning performance.

Stepless

Efficient Axial Fan

The stability of discharge pressure and suction pressure of compressor is assured The stability of flow (capacity) dynamic allocation of indoor unit is assured Quick response of control system is improved, accordingly the system stability, durability and reliability are assured

Reduction of Air Flow Resistance

Air Flow Resistance

Air Streamline Grille

Heat Transfer Coefficient

Improvement of Heat Transfer

Face Velocity

Amount of Frost

HIGH EFFICIENCY

07/08

HIGH RELIABILITY

Key Features and Benefits

Patented 360° Fitted Refrigerant Cooling Technology, More Reliable Cooling System

Optimized Refrigerant Circuit The heat-exchange efficiency is substantially increased due to the specially designed refrigerant flow structure. Gas Phase

Liquid Phase Gas Phase

Liquid Phase

With the patented 360° refrigerant cooling technology, heat will be removed from the main PCB. It can help to improve the electrical reliability when it is running under high ambient temperature. This can effectively prevent poor heat dissipation and ensure stability and safety under cooling mode.

Increase the liquid refrigerant volume proportion

Conventional

2-in-1 Refrigerant Flow Path

Hi-FLEXi S Series Common Refrigerant Circuit

Hi-FLEXi W Series

Optimized Refrigerant Circuit

Gas

Liquid Refrigerant

Refrigerant

Gas

Liquid Refrigerant

Refrigerant

Oil Return The accumulator adopts porous oil return technology with a built-in fine strainer, which not only ensures oil balance between compressors within one module, but also plays an important role in the oil balance between modules.

Gas Refrigerant

Liquid Refrigerant

Gas Refrigerant

Gas-liquid mixed phase

Liquid phase

Liquid Refrigerant

Gas phase

Gas-liquid mixed phase

Liquid phase

Gas Refrigerant

Gas phase

Gas Refrigerant

Liquid Refrigerant

Outdoor unit 1

Increase the proportion of liquid refrigerant in the heat exchanger to improve heat transfer efficiency

Outdoor unit 2

Two-stage Subcooling A subcooling section is designed in the heat exchanger of outdoor unit to realize the first-stage subcooling. Furthermore, a high efficient double pipe is applied to achieve the second-stage subcooling. The total subcooling degree is up to 27℃ , which improves cooling capacity and increases the total piping length.

Two-Stage Super-Cooling Cycle Diagram

Two-Stage Super-Cooling Pressure Enthalpy Diagram

First Stage of Super-cooling

Sub-cooler

Heat Exchanger Super-cooling Section

Second Stage of Super-cooling

The Increased Cooling Capacity in Super-cooling Cycle

○The two-stage super-cooling cycle improves cooling capacity; ○The pressure loss of the refrigerant flow in the pipe is reduced ○The increased super-cooling degree promotes the stable operation of the electronic expansion valve; ○The increased super-cooling degree increases the total piping length.

Cooling Capacity

Accumulator

Oil Return Operation

Compressor Frequency

Except for this, the system implements oil-return operation based on compressor frequency and corresponding operation time. The oil-return operation takes 60 seconds, and can return to previous operation state when it’s done.

High

In winter under heating mode, this operation is implemented without changing to cooling, which guarantees heating effect.

Low

Time

T t

t

09/10

HIGH RELIABILITY

Key Features and Benefits

Rotational Operation

Oil Separation First-stage oil separation is realized through efficient oil separation structure inside high-pressure-chamber compressor. Only a small amount of oil is brought out of the compressor.

During second-stage oil separation, the small amount of oil discharged from compressor is separated by a large-capacity, high-efficiency centrifugal oil separator, with efficiency over 99%.

Regulating the operation time of each outdoor unit leads to load reduction on compressors, thus, outdoor unit endurance is improved.

A

B

100h ON

101h OFF

C 102h OFF

A

B

C

A

D 103h OFF

104h OFF

B 101h ON

D

B

C

C

D

102h OFF

103h OFF

D

A

Rotational Operation

A First-stage oil separation

Second-stage oil separation

104h OFF

B

C

105h OFF

D

106h OFF

D

A

B

103h ON

A

B

104h OFF

105h OFF

C

C

D

102h ON

C

D

A

103h OFF

B

Double Back-up Function

Oil Balance Through adjusting the amount of discharge oil and return oil in the compressor, accumulator and oil separator, oil balance is perfectly achieved without oil balance pipe. This can avoid fluctuations of system pressure and temperature to ensure stability, and simplify the construction work.

In single module system, one compressor can start to operate when another fails. In module combination, one outdoor unit can start to operate when another fails. Double back-up function ensures reliability and stability of Hisense VRF system.

Standby Status

Liquid pipe

Gas pipe

Without oil balance pipe

Compressor Backup

Outdoor Unit Backup

Operating Status

Failed Status

HIGH RELIABILITY

11/12

BEST COMFORT

Anti-corrosion

Key Features and Benefits

Refrigerant Temperature Control Hisense refrigerant temperature control can provide best comfort for users. The evaporating temperature value can be adjusted either automatically according to indoor load in a certain range or manually according to the application environment.

The anti-corrosion treated outdoor units have been designed to provide corrosion resistance against acid rain and salt corrosion.

Features:

1.Evaporating temperature can be adjusted between 2°C to 16°C

Fan Protection

which is the widest on the market. 2.Rapidly cooling depends on the lower evaporating temperature.

Convention

3.Preventing cold draft bases on the higher evaporating temperatures. 4.Save energy by increasing seasonal efficiency. Instantaneous reverse rotation with sudden increased torque may cause damage to the blades

External forces make the fan Counter-rotate

Precise Temperature Control

Fan Protection Function

Multiple thermal probes in indoor unit to provide precise real-time temperature feedback.

2000-step electronic expansion valve to ensure precise flow adjustment based on the actual load of Indoor Unit.

Unique Design outlet air temperature sensor

External forces make the fan Counter-rotate

The fan stops before the unit starts

Forward rotation with small starting torque, protect fan blades

2000-step Electronic Expansion Valve

Condensed Water Leakage Protection

Conventional Temperature Control

Float switch is a standard part in Hisense indoor unit. To protect the ceiling from getting wet or soaked, the float switch will work to stop indoor unit when condensed water can’t be drained in time because of blockage of drain pump or drain pump breakdown. Operating

Condensed Water Warning

Stop

Too Hot

Precisely judge indoor temperature: (1)Air return temperature. sensor

Most Comfortable

(2)temperature. sensor on Wired remote controller (3)Based on the average value.

Suitable for irregularly shaped room

Setting temperature.

±0.5

Comfortable

Too Cold

Hisense Temperature Control

13/14

BEST COMFORT

Key Features and Benefits

Rapid Heating Start-up

Outdoor Unit Noise Control

Combing the soft start of DC inverter compressor and rapid start of fixed speed compressor, the system can achieve 100% heating capacity output instantly to meet the air conditioning demand. HP

Night Mute Control Night-shift function is equipped to reduce the noise by up to 15 dB.

Load Change Curve

90 seconds rapid start-up

Peak Temperature

100% Capacity Output

Temperature Change Curve Common Models

Noise Change Curce

Hisense Hi-FLEXi S Series

0

90seconds

Time

5min

Low Noise Mode

*Taking 66HP as an example

The user can flexibly select the noise reduction value according to the actual requirement and meet the ability requirements. In addition, the operation period of low noise mode can be determined by external input (Signal input).

Intelligent Defrosting Mode The outdoor unit adopts 3 sensors to precisely grasp the defrosting opportunity. Also, it has an anti-frost structure at the bottom, both of which reduces the amount of frost to only 1/3 compared to ordinary defrosting mode.

Hisense optimal defrost mode

Heating operation Little frost

Heating operation

Defrosting

Still not much frost

Heating operation

VIP Mode

Heating operation Little frost

Heating operation

Heating operation

Heating operation

Heating operation

Hisense outdoor units have VIP mode setting function. Under this mode, the system will satisfy the cooling need of the VIP room firstly.

Still not much frost

Heating operation

Traditional defrosting mode Heating operation

Heating operation

Heating operation

Anti-frost Structure

Note: this function is an optional function. It can be set according to the actual requirement ( a system can set max.5 indoor units as VIP ) . Under the severe operating condition, other indoor units' capacity may be influenced when customers use this function.

15/16

BEST COMFORT

Key Features and Benefits

Demand Mode

Automatically Adjust Setting Temperature

The intelligent demand mode can adjust the air conditioning operation automatically according to peak-valley requirements of electricity. It achieves balance between comfort and energy-saving while meeting the power demand for daily work.

Power Consumption

When the power consumption value exceeds the set range, it will be restricted

With Motion Sensor, the indoor unit will automatically adjust the setting temperature according to the indoor heat source load. The indoor unit will be turned off automatically when no people in room. The sensor also comes with draft functions to direct the air blowing people or avoiding people.

Power Saving 20%-60%

Setting Power Greater efficiency within the set range

Normal Operating Cost

Daily running time Morning

Night

Demand Mode Operating Cost

More Reasonable Air Distribution Unser-friendly Air Supply Mode and Louvers Control Independently a. The unit has the breeze mode that provides miniature draft through the holes at the four flat corners. b. The 4 air louvers can be controlled independently and 4 air speed adjustment are available to meet various requirement.

More Health Duct Adapter In order to satisfy the fresh air intake function, the Duct Adapter as the optional part equips at the mini 4-way cassette type and 4-way cassette type.

Humidity Sensor Humidity Sensor has the automatic dehumidification function that will create comfortable indoor environment for users. Humidity Sensor possesses the low temperature dehumidification function.

Environmental Protection

Fresh Air Introduction

Hisense VRF adopts reliable eco-friendly refrigerant R410A, which is non-toxic to human and does not damage the Earth’s ozone layer. Also, we actively respond to Europe RoHS directive, controlling the use of hazardous substance strictly.

Hisense VRF system can introduce outdoor fresh air into indoor space through fresh air equipment such as all fresh air indoor unit and heat recovery ventilator, which constantly supplies fresh air and creates a healthy environment for users.

Environment-friendly Refrigerant

17/18

MORE FLEXIBILITY DESIGN

Key Features and Benefits

Summary of Pipe Length

Series Item

Unit

Fan Static Pressure Adaptive Technology Making Installation Space More Flexible S

W

G+

X

R

heat recovery

Total Piping Length

m

1000

1000

1000

1000

500

Max. piping Length Equivalent (actual)

m

190(165)

190(165)

190(165)

190(165)

190(165)

Height difference between Indoor Units

m

30

30

30

30

15

Piping Length between 1st Branch and indoor unit

m

90

90

90

90

40

Outdoor Unit is higher

m

90*

90*

90*

50

50

Outdoor Unit is lower

m

90*

90*

90*

40

40

m

10

10

10

10

10

Height difference between outdoor unit and indoor unit

Largest pipe length of pipes between outdoor units

Up to 110Pa*

Layered installing outdoor units easily dealing with heat dissipation problem.

Easy to conceal outdoor unit, good looking of facades

Air flow diagram

*Note: By the note corresponding, eternal static pressure of the outdoor unit can be up to 110Pa. For detailed information, please contact Hisense’s technical staff.

Minimized Floor Space

*Note: For detailed information, please consult the technical staff.

The large capacity outdoor units achieves the minimized floor space.

Wide Operating Range Meets Greater Demand With a wide operating temperature range, the outdoor unit can operate from -25°C WB to 16.5°C WB. The heating effect in winter is strong, which perfectly meets the customers’ needs in different environments. The unit is able to operate in -25°C WB ambient, when the unit is heating mode and also operate at 52°C WB ambient in cooling mode.

With static pressure adaptive technology, the fan of the outdoor unit can be adjusted in free static pressure based on system requirements to meet a variety of needs in different environments. The maximam external static pressure of the outdoor unit can be up to 110Pa*, which provides better conditions for the layered installation and centralized installation. Higher static pressure and further distance of air supply of the outdoor unit ensure the smooth flow of air and solve condensing problems of the outdoor unit effectively.Enough already been said about the static and flexibility so delete last sentence.

°C WB °C WB

VS

°C WB °C WB

24HP

24HP

previous

New

previous

New

19/20

MORE FLEXIBILITY INSTALLATION AND MAINTENANCE

Key Features and Benefits

One-touch Test Run

Compact and Light-weight Design

The one-touch test run can be operated at the outdoor unit side as well as the indoor unit side, which makes it much easier for commissioning.

ON

Easy for transportation

1

ON

2

3

4

5

6

Cooling mode test run

Elevator

7-segment LED on the Outdoor The 7-segment LED on the outdoor unit makes it easy to monitor and check the details about the operating status such as refrigerant temperature, pressure, compressor frequency, alarm code, etc., which makes both operation management and maintenance more convenient.

Realizing test run through the controller at the indoor unit side

1

2

3

4

5

Heating mode test run

Realizing test run through the DIP-switch at the outdoor unit side.

Intelligent Detection The specially designed Data collector can automatically detect the systems running condition. With real time monitoring, system parameters, trouble shooting and preventative maintenance can be managed.

Automatic Detection Through Computer

Indoor Unit Data Collector

H-Assist DeviceOutdoor Unit

Indoor Unit

Indoor Unit

21/22

MORE FLEXIBILITY INSTALLATION AND MAINTENANCE

Easy-to-read Error

Key Features and Benefits

Automatic Restart

The access hole is designed on the electrical box plate, which makes more convenient and safety checking PSW button and SEGD without taking down the electrical box plate.

Service Window

When power resumes, the AC will has two modes. Mode 1: the AC will re-start, no matter what status the AC is before power failure. Mode 2: the AC will return to previous setting automatically.

Service Window

The system operates normally before power off

01

Handle Hi-FLEXi S Series

After power off ( memory storage ) system stops running

02

Restore to the previous state when the power supply is recovered

03

Hi-FLEXi W Series

Automatic Addressing Hisense VRF system can assign indoor unit addresses automatically, It is convenient in the case of large system with a lot of indoor units.

Urgent Power-off Maintenance of Indoor Units When one indoor unit need maintenance, it can be powered off separately. Also, it does not need any setting on outdoor, automatically re-regist all indoor unit and have no influence on the whole system.

Product Line

Product Line Outdoor Unit Air to Water Heat Pump Indoor Unit ​Ventilation Solution​

25/26

OUTDOOR UNIT

HP

S

G+

X

R

W

H

MULTIFUNCTION

Hi-AquaSmart

2.5 3

4

5

Product Line

6

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112

27/28

OUTDOOR UNIT

Hi-FLEXi

Product Line

Patented 360°

S Series

Fitted Refrigerant Cooling Technology, More Reliable Cooling System With the patented 360° refrigerant cooling technology, Hi-FLEXi S Series will remove the heat from the main PCB, inverter module and outdoor unit's electrical box stably and efficiently. It can help to improve the electrical reliability of the unit when it is running under high ambient. This ensures stability and safety of the outdoor unit running and also prevents poor heat dissipation caused by the fan cycle rotation or stop mode.

Latest enhanced capacity series: G-type heat exchanger, more efficient Enhanced vapor injection scroll compressor with rapid heating performance Float switch design, ensuring decoration safety Wide operating range, precise temperature control

◎ The refrigerant heat sink of aluminum alloy with high thermal conductivity and the internal mechanical tube can integrate closely to keep the heat transfer efficiency.

Patent Number: 1.Processing method of refrigerant heat sink, air conditioning and refrigerant cooling, 201710413663.X 2.Refrigerant heat sink and air conditioning, 201720645923.

New Generation of Enhanced Vapor Injection Scroll Compressor Hisense Hi-FLEXi S Series adopts a new generation of the high efficiency scroll compressor and the patented vapor injection technology*1. It can greatly enhance the heating performance and achieve high energy-saving efficiency. Powerful heating is guaranteed by Hi-FLEXi S Series, especially under low temperature with heating performance increased up to 25%, compared with the standard model.

◎ A tin heat conductor is added between the refrigerant pipe and the heat sink built-in the electrical component to increase the heat transfer efficiency. Made by imported lead-free solder film with high thermal conductivity, the tin heat conductor greatly improve the overall performance.

Note:*1. Patent number: a heat exchange cycle system and control methods and air conditioning, 201610909006.X Patent Number: 3.Testing device and method of a refrigerant heat sink, 201710456157.9 4.Testing device and method for refrigerant heat sink, 201710601662.8

DC Frequency Inverter Technology in Compressor Hisense VRF adopts a wide range and high-precision inverter technology. Its adjustment range is 0-450Hz and the control accuracy is 0.01Hz. The running speed of outdoor DC inverter compressor can be adjusted continuously and freely, which improves the user experience and also enhances the energy efficiency of the unit.

Load % Air conditioning capacity output Indoor load

Tube Expander

Refrigerant Pipe

Heat Sink

Heat Sink

Heat Conductor

Precise Inverter Control

Time (h)

Heat Sink Built-in Electrical Component

29/30

OUTDOOR UNIT

Product Line

Extra Long Pipe Enabling The Height Difference Between Indoor and Outdoor Units up to 90 Meters *

Powerful Heating Performance Under Low Temperature The system uses the vapor injection two-stage compressor technology and intelligent defrost technology to achieve strong heating efficiency which ensures the strong heating performance even under -25℃ .

With extra long pipe, the height difference between the indoor unit and outdoor unit is up to 90 meters *, which makes installation more flexible. Maximum length of a single pipe: 190 meters total length of pipes: 1000 meters

Maximum height difference between indoor and outdoor units: the upper face of the outdoor unit is 50m and the bottom of the outdoor unit is 40m

Snowing

Snowing

largest pipe length of pipes between outdoor units: 10 meters

By the note corresponding: when the outdoor unit is above:90m* when the outdoor unit is below:90m*

Feel Cold

Feel Comfortable

Maximum length from the first branch pipe to the farthest indoor unit: 90m

Maximum height difference of indoor units: 30m

Rapid Heating Under Low Temperature *NOTE: For detailed information, please consult the technical staff.

When the Hi-FLEXi S Series is running at a low outdoor ambient of -15oC, the outlet air temperature of the indoor unit can reach up to 40oC or higher* in a short time. The outdoor unit has a fast and powerful heating efficiency, so it can offer you a warm and comfortable environment in winter.

Heating at -15 C o

This test result is based on the 10HP outdoor unit and 2 indoor units

50 40

Test conditions: Outdoor suction temperature: -15oC(dry bulb), 30 Relative humidity:75%, Indoor unit suction temperature:20oC(dry bulb), high air volume. 20 Length of indoor and outdoor pipes: 6 meters. Measurement sites: laboratory of constant temperature. Note: The actual heat time depends on the heat load, models and building structure.

Fan Static Pressure Adaptive Technology Making Installation Space More Flexible With static pressure adaptive technology, the fan of the outdoor unit can be adjusted in free static pressure based on system requirements to meet a variety of needs in different environments. The maximam external static pressure of the outdoor unit can be up to 110Pa*, which provides better conditions for the layered installation and centralized installation. Higher static pressure and further distance of air supply of the outdoor unit ensure the smooth flow of air and solve condensing problems of the outdoor unit effectively.Enough already been said about the static and flexibility so delete last sentence.

Time (Mins)

10 0

5

10

15

Hisense Hi-FLEXi S Series

20

25

30

35

Common models

Layered installing outdoor units easily dealing with heat dissipation problem.

Easy to conceal outdoor unit, good looking of facades

*Note: By the note corresponding, eternal static pressure of the outdoor unit can be up to 110Pa. For detailed information, please contact Hisense’s technical staff.

Air flow diagram

31/32

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

Hi-FLEXi S Series

HP

8HP

10HP

Model



Combination



Power Supply Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

12HP

14HP

16HP

18HP

AVWT-76HKSS AVWT-96HKSS AVWT-114HKSS AVWT-136HKSS AVWT-154HKSS AVWT-170HKSS

22.4 5.21 4.30 25.0 5.77 4.33 183 59

28.0 7.00 4.00 31.5 7.59 4.15 183 60

Φ19.05 Φ9.53 1730 950 750 1930 1015 790 13 25 17.2 224 243

Φ22.20 Φ9.53 1730 950 750 1930 1015 790 16 32 22.5 244 263

1 1

1 1





380-415V 3N~ 50Hz / 60Hz 33.5 40.0 8.65 10.53 3.87 3.80 37.5 45.0 9.21 11.72 4.07 3.84 183 200 62 62 Grayish White Enhanced Vapor Injection Compressor R410A Φ25.40 Φ25.40 Φ12.70 Φ12.70 1730 1730 950 1210 750 750 1930 1930 1015 1275 790 790 19 23 32 40 23.5 28.6 245 297 265 321 50% - 150% 1 1 1 2 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000





Hi-FLEXi S Series

HP

Model Combination

20HP

22HP

24HP

26HP

28HP

AVWT-190HKSS

AVWT-212HKSS

AVWT-232HKSS

AVWT-250HKSS

AVWT-272HKSS









56.0 17.90 3.13 63.0 19.87 3.17 267 63

61.5 20.50 3.00 69.0 22.48 3.07 296 64

Φ28.60 Φ15.88 1730 1350 750 1930 1420 790 33 63 44.5 361 395

Φ28.60 Φ15.88 1730 1350 750 1930 1420 790 36 63 49.8 369 396

2 2

2 2

Power Supply 45.0 12.50 3.60 50.0 13.70 3.65 200 62

50.0 15.63 3.20 56.0 16.97 3.30 200 62

Φ28.60 Φ12.70 1730 1210 750 1930 1275 790 26 40 33 298 322

Φ28.60 Φ15.88 1730 1210 750 1930 1275 790 29 50 38.6 347 371

1 2

2 2

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

380-415V 3N~ 50Hz / 60Hz 68.0 72.5 22.82 24.58 2.98 2.95 75.0 80.0 24.59 26.67 3.05 3.00 296 350 66 67 Grayish White Enhanced Vapor Injection Compressor R410A Φ28.60 Φ15.88 1730 1350 750 1930 1420 790 40 63 52.4 370 397 50% - 150% 2 2 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

— 80.0 27.59 2.90 90.0 30.41 2.96 350 67

Φ31.75 Φ19.05 1730 1600 750 1930 1665 790 43 80 56.9 414 446

Φ31.75 Φ19.05 1730 1600 750 1930 1665 790 47 80 58.2 415 447

2 2

2 2

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m

Cooling conditions: indoor air inlet temperature: 27oC DB 19℃ WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m

Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m

Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

33/34

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

30HP

32HP

34HP

Model

AVWT-290HKSS

AVWT-308HKSS

AVWT-324HKSS

AVWT-344HKSS

AVWT-360HKSS

Combination

AVWT-154HKSS AVWT-136HKSS

AVWT-154HKSS AVWT-154HKSS

AVWT-170HKSS AVWT-154HKSS

AVWT-190HKSS AVWT-154HKSS

AVWT-190HKSS AVWT-170HKSS

Hi-FLEXi S Series

HP

Power Supply Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

36HP

38HP

380-415V 3N~ 50Hz / 60Hz 95.0 101.0 28.13 30.40 3.38 3.32 106.0 113.0 30.67 33.57 3.46 3.37 400 467 67 67 Grayish White Enhanced Vapor Injection Compressor R410A

85.0 23.03 3.69 95.0 25.42 3.74 400 67

90.0 25.00 3.60 100.0 27.40 3.65 400 67

Φ31.75 Φ19.05 1730 1210+1210 750 1930 1275+1275 790 49 80 61.6 595 643

Φ31.75 Φ19.05 1730 1210+1210 750 1930 1275+1275 790 52 80 66 596 644

2 4

2 4

Φ38.1 Φ19.05 1730 1210+1210 750 1930 1275+1275 790 55 100 71.6 645 693 50% - 150% 3 4 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

Φ38.1 Φ19.05 1730 1210+1350 750 1930 1275+1420 790 62 100 83.1 708 766

3 4

4 4

1. Rated cooling capacity and rated heating capacity are tested in the following conditions: Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

42HP

44HP

Model

AVWT-402HKSS

AVWT-422HKSS

AVWT-444HKSS

AVWT-464HKSS

Combination

AVWT-190HKSS AVWT-190HKSS

AVWT-232HKSS AVWT-170HKSS

AVWT-232HKSS AVWT-190HKSS

AVWT-232HKSS AVWT-212HKSS

AVWT-232HKSS AVWT-232HKSS

HP

Power Supply 106.0 33.53 3.16 119.0 36.84 3.23 467 67

Φ38.1 Φ19.05 1730 1210+1350 750 1930 1275+1420 790 59 100 77.5 659 717

Notes:

40HP AVWT-380HKSS

Hi-FLEXi S Series

Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

46HP

48HP

380-415V 3N~ 50Hz / 60Hz 124.0 129.5 40.72 43.32 3.05 2.99 138.0 144.0 44.46 47.07 3.10 3.06 563 592 68 68 Grayish White Enhanced Vapor Injection Compressor R410A

112.0 35.80 3.13 126.0 39.74 3.17 534 67

118.0 38.45 3.07 131.0 41.56 3.15 496 67

Φ38.1 Φ19.05 1730 1350+1350 750 1930 1420+1420 790 64 125 89 722 790

Φ38.1 Φ19.05 1730 1210+1350 750 1930 1275+1420 790 64 125 91 717 768

4 4

4 4

Φ38.1 Φ19.05 1730 1350+1350 750 1930 1420+1420 790 64 125 96.9 731 792 50% - 150% 4 4 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

136.0 45.64 2.98 150.0 49.18 3.05 592 69

Φ41.3 Φ22.2 1730 1350+1350 750 1930 1420+1420 790 64 125 102.2 739 793

Φ41.3 Φ22.2 1730 1350+1350 750 1930 1420+1420 790 64 125 104.8 740 794

4 4

4 4

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions: Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

35/36

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

50HP

52HP

54HP

Model

AVWT-482HKSS

AVWT-504HKSS

AVWT-522HKSS

AVWT-544HKSS

Combination

AVWT-250HKSS AVWT-232HKSS

AVWT-272HKSS AVWT-232HKSS

AVWT-272HKSS AVWT-250HKSS

AVWT-272HKSS AVWT-272HKSS

Hi-FLEXi S Series

HP

Power Supply *1

Cooling Operation

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

140.5 47.40 2.96 155.0 51.26 3.02 646 70

56HP

380-415V 3N~ 50Hz / 60Hz 148.0 152.5 50.41 52.17 2.94 2.92 165.0 170.0 55.00 57.08 3.00 2.98 646 700 70 70 Grayish White Enhanced Vapor Injection Compressor R410A

Φ41.3 Φ22.2 1730 1350+1600 750 1930 1420+1665 790 64 160 109.3 784 843

Φ41.3 Φ22.2 1730 1350+1600 750 1930 1420+1665 790 64 160 110.6 785 844

4 4

4 4

160.0 55.18 2.90 180.0 60.82 2.96 700 70

Φ41.3 Φ22.2 1730 1600+1600 750 1930 1665+1665 790 64 160 115.1 829 893

Φ41.3 Φ22.2 1730 1600+1600 750 1930 1665+1665 790 64 160 116.4 830 894

4 4

4 4

50% - 150%

50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions: Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

58HP

60HP

62HP

Model

AVWT-552HKSS

AVWT-570HKSS

AVWT-592HKSS

AVWT-612HKSS

Combination

AVWT-212HKSS AVWT-170HKSS AVWT-170HKSS

AVWT-190HKSS AVWT-190HKSS AVWT-190HKSS

AVWT-232HKSS AVWT-190HKSS AVWT-170HKSS

AVWT-232HKSS AVWT-190HKSS AVWT-190HKSS

Hi-FLEXi S Series

HP

Power Supply Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

161.5 51.76 3.12 181.0 56.42 3.21 696 70

Φ44.5 Φ22.2 1730 1210+1210+1350 750 1930 1275+1275+1420 790 64 160 127 1063 1138 6 6

64HP

380-415V 3N~ 50Hz / 60Hz 168.0 174.0 53.70 56.35 3.13 3.09 189.0 194.0 59.61 61.43 3.17 3.16 801 763 70 70 Grayish White Enhanced Vapor Injection Compressor R410A Φ44.5 Φ44.5 Φ22.2 Φ22.2 1730 1730 1350+1350+1350 1210+1350+1350 750 750 1930 1930 1420+1420+1420 1275+1420+1420 790 790 64 64 160 160 133.5 135.5 1083 1078 1185 1163 50% - 150% 6 6 6 6 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

180.0 58.62 3.07 201.0 64.33 3.12 830 70

Φ44.5 Φ22.2 1730 1350+1350+1350 750 1930 1420+1420+1420 790 64 200 141.4 1092 1187

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions: Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oCor -25oC~-20oC, please contact our professional engineer.

6 6

37/38

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

66HP

68HP

70HP

72HP

Model

AVWT-634HKSS

AVWT-654HKSS

AVWT-676HKSS

AVWT-696HKSS

Combination

AVWT-232HKSS AVWT-212HKSS AVWT-190HKSS

AVWT-232HKSS AVWT-232HKSS AVWT-190HKSS

AVWT-232HKSS AVWT-232HKSS AVWT-212HKSS

AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS

Hi-FLEXi S Series

HP

Power Supply Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

185.5 61.22 3.03 207.0 66.94 3.09 859 70

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min

Φ44.5 Φ22.2 1730 1350+1350+1350 750 1930 1420+1420+1420 790 64 200 146.7 1100 1188 6 6

76HP

78HP

80HP

Model

AVWT-732HKSS

AVWT-754HKSS

AVWT-776HKSS

Combination

AVWT-250HKSS AVWT-232HKSS AVWT-232HKSS

AVWT-250HKSS AVWT-250HKSS AVWT-232HKSS

AVWT-272HKSS AVWT-250HKSS AVWT-232HKSS

AVWT-272HKSS AVWT-272HKSS AVWT-232HKSS

HP

Power Supply

380-415V 3N~ 50Hz / 60Hz 192.0 197.5 63.54 66.14 3.02 2.99 213.0 219.0 69.05 71.66 3.08 3.06 859 888 70 70 Grayish White Enhanced Vapor Injection Compressor R410A Φ50.8 Φ50.8 Φ25.4 Φ25.4 1730 1730 1350+1350+1350 1350+1350+1350 750 750 1930 1930 1420+1420+1420 1420+1420+1420 790 790 64 64 200 200 149.3 154.6 1101 1109 1189 1190 50% - 150% 6 6 6 6 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

74HP AVWT-714HKSS

Hi-FLEXi S Series

204.0 68.46 2.98 225.0 73.77 3.05 888 71

Φ50.8 Φ25.4 1730 1350+1350+1350 750 1930 1420+1420+1420 790 64 200 157.2 1110 1191

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions: Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

6 6

Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

208.5 70.22 2.97 230.0 75.85 3.03 942 71

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min

Φ50.8 Φ25.4 1730 1350+1350+1600 750 1930 1420+1420+1665 790 64 200 161.7 1154 1240 6 6

380-415V 3N~ 50Hz / 60Hz 213.0 220.5 71.98 74.99 2.96 2.95 235.0 245.0 77.93 81.67 3.02 3.00 996 996 71 71 Grayish White Enhanced Vapor Injection Compressor R410A Φ50.8 Φ50.8 Φ25.4 Φ25.4 1730 1730 1350+1600+1600 1350+1600+1600 750 750 1930 1930 1420+1665+1665 1420+1665+1665 790 790 64 64 200 200 166.2 167.5 1198 1199 1289 1290 50% - 150% 6 6 6 6 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

228.0 78.00 2.92 255.0 85.41 2.98 996 71

Φ50.8 Φ25.4 1730 1350+1600+1600 750 1930 1420+1665+1665 790 64 200 168.8 1200 1291

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions: Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

6 6

39/40

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

82HP

84HP

86HP

88HP

Model

AVWT-794HKSS

AVWT-816HKSS

AVWT-824HKSS

AVWT-844HKSS

Combination

AVWT-272HKSS AVWT-272HKSS AVWT-250HKSS

AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS

Hi-FLEXi S Series

HP

Power Supply Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

232.5 79.76 2.91 260.0 87.49 2.97 1050 72

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min

Φ50.8 Φ25.4 1730 1600+1600+1600 750 1930 1665+1665+1665 790 64 250 173.3 1244 1340 6 6

AVWT-232HKSS AVWT-212HKSS AVWT-190HKSS AVWT-190HKSS 380-415V 3N~ 50Hz / 60Hz 240.0 241.5 82.77 79.12 2.90 3.05 270.0 270.0 91.23 86.81 2.96 3.11 1050 1126 72 72 Grayish White Enhanced Vapor Injection Compressor R410A

AVWT-232HKSS AVWT-232HKSS AVWT-190HKSS AVWT-190HKSS

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

HP

90HP

92HP

94HP

96HP

AVWT-908HKSS

AVWT-928HKSS

Model

AVWT-866HKSS

AVWT-886HKSS

Combination

AVWT-232HKSS AVWT-232HKSS AVWT-212HKSS AVWT-190HKSS

AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-190HKSS AVWT-212HKSS 380-415V 3N~ 50Hz / 60Hz 260.0 265.5 86.36 88.96 3.01 2.98 288.0 294.0 93.64 96.25 3.08 3.05 1155 1184 72 72 Grayish White Enhanced Vapor Injection Compressor R410A

Power Supply 248.0 81.44 3.05 276.0 88.92 3.10 1126 72

Φ50.8 Φ50.8 Φ50.8 Φ25.4 Φ25.4 Φ25.4 1730 1730 1730 1600+1600+1600 1350+1350+1350+1350 1350+1350+1350+1350 750 750 750 1930 1930 1930 1665+1665+1665 1420+1420+1420+1420 1420+1420+1420+1420 790 790 790 64 64 64 250 250 250 174.6 191.2 193.8 1245 1461 1462 1341 1583 1584 50% - 150% 8 8 6 8 8 6 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

Notes:

Hi-FLEXi S Series

Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

253.5 84.04 3.02 282.0 91.53 3.08 1155 72

Φ50.8 Φ25.4 1730 1350+1350+1350+1350 750 1930 1420+1420+1420+1420 790 64 250 199.1 1470 1585 8 8

AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS 272.0 91.28 2.98 300.0 98.36 3.05 1184 72

Φ50.8 Φ50.8 Φ50.8 Φ25.4 Φ25.4 Φ25.4 1730 1730 1730 1350+1350+1350+1350 1350+1350+1350+1350 1350+1350+1350+1350 750 750 750 1930 1930 1930 1420+1420+1420+1420 1420+1420+1420+1420 1420+1420+1420+1420 790 790 790 64 64 64 250 250 320 201.7 207 209.6 1471 1479 1480 1586 1587 1588 50% - 150% 8 8 8 8 8 8 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m

Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

41/42

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

98HP

100HP

102HP

104HP

Model

AVWT-946HKSS

AVWT-968HKSS

AVWT-988HKSS

AVWT-1008HKSS

Combination

AVWT-250HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS

AVWT-272HKSS AVWT-272HKSS AVWT-232HKSS AVWT-272HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-212HKSS 380-415V 3N~ 50Hz / 60Hz 284.0 289.5 96.05 98.50 2.96 2.94 315.0 324.0 104.18 107.89 3.02 3.00 1238 1292 72 72 Grayish White Enhanced Vapor Injection Compressor R410A

AVWT-272HKSS AVWT-272HKSS AVWT-232HKSS AVWT-232HKSS

Hi-FLEXi S Series

HP

Power Supply Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

276.5 93.04 2.97 305.0 100.44 3.04 1238 72

1. Rated cooling capacity and rated heating capacity are tested in the following conditions: Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

HP

106HP

108HP

110HP

112HP

Model

AVWT-1026HKSS

AVWT-1048HKSS

AVWT-1066HKSS

AVWT-1088HKSS

Combination

AVWT-272HKSS AVWT-272HKSS AVWT-250HKSS AVWT-232HKSS

AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-232HKSS AVWT-250HKSS 380-415V 3N~ 50Hz / 60Hz 308.0 312.5 105.59 107.35 2.92 2.91 345.0 350.0 115.82 117.9 2.98 2.97 1346 1400 73 73 Grayish White Enhanced Vapor Injection Compressor R410A

AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS

Power Supply 296.0 100.82 2.94 330.0 110.00 3.00 1292 73

Φ50.8 Φ50.8 Φ50.8 Φ50.8 Φ25.4 Φ25.4 Φ25.4 Φ25.4 1730 1730 1730 1730 1350+1350+1350+1600 1350+1350+1350+1600 1350+1350+1600+1600 1350+1350+1600+1600 750 750 750 750 1930 1930 1930 1930 1420+1420+1420+1665 1420+1420+1420+1665 1420+1420+1665+1665 1420+1420+1665+1665 790 790 790 790 64 64 64 64 320 320 320 320 215.4 214.1 218.6 221.2 1525 1524 1569 1570 1638 1637 1687 1688 50% - 150% 8 8 8 8 8 8 8 8 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

Notes:

Hi-FLEXi S Series

Cooling Operation*1

Heating Operation*1 Air Flow Rate Noise level*2 Cabinet Color*3 Compressor Type Refrigerant Type Gas Line Liquid Line Out Dimension

kW Rated Capacity Power Consumption kW EER Rated Capacity kW Power Consumption kW COP m³/min dB(A)

H W D

mm mm mm mm mm mm mm mm

H W D Max.number of connectable IDU A Max. Fuse Current A Max. Running Current kg Net Weight kg Gross Weight Connection Ratio PC Compressor Quantity PC Condenser Fan Quantity Height Difference Between ODUs is Higher Than IDUs m ODUs and IDUs ODUs is Lower Than IDUs m m Height Difference Between IDUs Cooling DB Operation Range WB Heating Max. Total Piping Length m Packing Dimension

300.5 102.58 2.93 335.0 112.08 2.99 1346 73

320.0 110.36 2.90 360.0 121.64 2.96 1400 73

Φ50.8 Φ50.8 Φ50.8 Φ50.8 Φ25.4 Φ25.4 Φ25.4 Φ25.4 1730 1730 1730 1730 1350+1600+1600+1600 1350+1600+1600+1600 1600+1600+1600+1600 1600+1600+1600+1600 750 750 750 750 1930 1930 1930 1930 1420+1665+1665+1665 1420+1665+1665+1665 1665+1665+1665+1665 1665+1665+1665+1665 790 790 790 790 64 64 64 64 320 320 320 320 227 225.7 231.5 232.8 1615 1614 1659 1660 1738 1737 1787 1788 50% - 150% 8 8 8 8 8 8 8 8 50 (90*4) 40 (90*4) 30 -5oC~ 52oC*5 -25oC*5~ 16.5oC 1000

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions: Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.

43/44

OUTDOOR UNIT

Hi-FLEXi

Product Line

pole

G+ Series

6-pole high-flux neodymium magnetic motor rotor Motor rotor of the new type compressor uses the latest 6-pole highflux neodymium magneto structure, rotor shape design is optimized and all rotational speed control is more efficient. Original

Hi-FLEXi G+ Series is the latest larger capacity full DC inverter-driven multi-split central air conditioning product. It focuses on customers' requirement and comfort, representing Hisense high quality and technology. It’s characterized by:

Latest

New improved concentrated stator winding The new type motor stator is equipped with a centralized winding and more turns of windings, sets induced voltage to a higher value (to reduce current) and improves efficiency of motor at low rotational speed.

Latest enhanced capacity series: Brand new high-pressure chamber scroll compressor Integrated high-strength structure and convenient installation

Improved super-cooling

Adoption of double larger fans and low-pressure loss heat exchanger

The optimization of finned tubes, increasing of fins number and reducing of height on the basis of traditional secondary super-cooler reduces its pressure loss, increases coefficient of heat conduction and improves super-cooling performance.

Max. 22HP single unit, 4 modules' combination

Upgraded Core Technology

High-precise multiple electronic expansion valves control technology

New Hitachi high-pressure chamber scroll compressor, enhancing the efficiency Adoption of the brand new high-pressure chamber scroll compressor realizes high efficiency of motor, optimization of scroll plate and optimum fuel feeding, etc. and increases operation efficiency of compressor under overall operating conditions, especially, enhances intermediate performance greatly. High pressure chamber structure Oil film sealing technology Discharge pipes High strength roller-bearing Sensorless protection Oil sump shield Inner compressor cleaning function

The multiple high-precision electronic expansion valves equipped on the outdoor unit can adjust refrigerant flow of the unit rapidly and accurately according to commands, reduce power consumption during operation, improve energy efficiency and reduce fluctuation of indoor temperature, thus making the environment more comfortable and pleasant.

Electronic expansion valve

Anti-overcompressing Technique Exclusive asymmetric scroll technology Exclusive inner oil separating pipe New centralized stator winding

Optimization of the four-way valve

Optimization of ball check valve

Adoption of the new type high-capacity four-way valve reduces compression at four-way valve greatly, ensures suction intensity of compressor and improves performance of the complete machine.

The brand-new ball check valve, in which there is almost no part hindering fluid flow and thus the local pressure loss is improved significantly, enhances efficiency of the whole system.

Hitachi patent neodymium magnet motor rotor High strength shell design

Motor is the source of power of a compressor. Hi-FLEXi G+ Series compressor is equipped with a new DC motor (with centralized winding) which enhances performance of the compressor significantly at a frequency of 20-80Hz that the compressor operates at most frequently.

High capacity and less pressure loss four-way valve

45/46

OUTDOOR UNIT

Product Line

New Appearance

Wide Operation Range

The built-in design of PP air duct ensures safety of inner core effectively Combination of the integrated sheet-metal upper cover and protecting wire net structure realizes built-in design of PP air duct with optimal protection performance, effectively protecting important parts (e.g. fan) from being damaged when the outdoor unit being hit by object from high altitudes.

The highest working temperature reaches upto 52°C in cooling mode, and lowest working temperature reaches -20°C in heating mode.

A

Note: when the designed cooling temperature is over 43oC, please contact our professional engineer.

A

High strength motor bracket, more stable and quiet B

More Flexible Refrigerant Piping Work

B

B

High strength frame structure with inside upright column

Max. piping length: 190m* Max. total piping length: 1000m

Height difference between outdoor and indoor unit Outdoor unit is higher: 90m* Outdoor unit is lower: 90m*

Height difference between indoor units: 30m*

Integrated high-strength side plate decreases vibration and reduces noises Compared with the form combining stand column with wire net, Hi-FLEXi G+ Series is equipped with integrated highstrength side plates made from high-quality materials, which increases air handling area and reduces the vibration and noises produced during operation of the machine.

Max. piping length between 1st branch and indoor unit: 90m

Note: For data marked by *, please contact our professional engineer.

New-efficiency Common air conditioner

The 644mm large dual-fan leads the industry Hi-FLEXi G+ Series (20-22HP) is equipped with 644mm×2 large fans characterized by low noise and large air flow, greatly improving heat exchange efficiency of heat exchanger.

644mm

The Hi-FLEXi G+ Series adopts new structure and advanced technology, providing new High efficiency combination solution.

Hi-FLEXi G+ Series

Common double fans diameter: 540mm

Hisense double large fans diameter: 644mm

47/48

OUTDOOR UNIT

Product Line

6-side heat exchanging of low pressure-loss ∑ type heat exchanger The low pressure-loss ∑ type heat exchanger is structurally designed with a 6-side heat exchange structure and dual-fan, which realizes more uniform distribution of heat exchanger's wind field gradient under the same air-flow conditions, and improves heat-exchanging efficiency of heat exchanger. Meanwhile, higher height, larger heat exchange area and low pressure-loss optimization of flow in bypass branch of the heat exchanger itself improves heat-exchanging efficiency of refrigerant and ensures strong heat-exchanging performance of the complete machine.

New Installation

The modular design makes installation easier Hi-FLEXi G+ Series is characterized by compact structure and modular design by breaking up the whole system into parts, making it easier for both installation and transportation. Taking 88HP as an example, capacity of a single-module product is up to 22HP. And, it can be an assembly of 4 modules, not only meeting the high-capacity requirement but effectively save the space. The volume is convenient for elevator transportation

Large outdoor heat exchanger

Large outdoor heat exchanger of Hisense

Integrated four-side heat exchanger

Common four-side heat exchanger

Static pressure of outdoor unit is up to 85Pa

For the large outdoor heat exchanger of Hisense, the heat exchanger is characterized by larger face area and better heat-exchanging efficiency. Meanwhile, it reserves more space for arrangement of piping of refrigerating system and heat exchanger distribution pipe, thus ensuring better maintainability.

The maximum static pressure of outdoor unit is up to 85Pa and is suitable for layered installation and centralized installation. The higher static pressure and longer air supplying distance of outdoor unit ensures smooth circulation of air flow and solves the problem of heat dissipation of outdoor unit effectively. The outdoor unit featured with higher static pressure, well responds to the severe environment where the outdoor unit is placed at, is available for more flexible arrangement and is favorable for concealed installation of outdoor unit. *Note: for details, please consult the technical personnel.

1.90

Note: the other shape of heat exchanger is taken as an example.

Separation of machine room and electric room makes maintenance more convenient In the new structure, divisional design of front metal plate, separate assembling of metal plates in each part and separation of electric room and machine room improve repair and maintenance convenience. Modularized design of electric box and spatial independence of two variable frequency compressors’ control circuits reduce mutual crosstalk, enhance EMC performance greatly and make heat emission efficiency better.

Max.

85Pa

Layered arrangement of outdoor unit solves the problem of heat dissipation easily

Favorable for concealed installation of outdoor unit and making the facade more aesthetic

Air distribution schematic diagram

49/50

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

8HP

10HP

12HP

14HP

AC3Φ380V~415V/50/60Hz

AVWT-76UKSNA

AVWT-96UKSNA

AVWT-114UKSNA

AVWT-136UKSTA

AC3Φ208~230V/60Hz

AVWT-76U8SNA

AVWT-96U8SNA

AVWT-114U8SNA

AVWT-136U8STA

kW

22.4

28.0

33.5

40.0

KBtu/h

76.4

95.5

114.3

136.5

Power Consumption kW

5.00

6.95

8.66

10.61

EER

4.48

4.03

3.87

3.77

25.0

31.5

37.5

45.0

HP

Hi-FLEXi G+ Series Model Power Supply Combination

Nominal Capacity Heating Operation

kW KBtu/h

85.3

107.5

128.0

153.5

Power Consumption kW

5.00

6.35

8.06

9.91

COP

5.00

4.96

4.65

4.54

9,300

10,200

10,500

11,700

Air Flow Rate

m³/h

Outer Dimension (H×W×D)

mm

1,730×950×750

1,730×950×750

1,730×950×750

Packing Dimension (H×W×D)

mm

1,930×1,015×790

1,930×1,015×790

1,930×1,015×790

Net Weight

Kg

239

240

241

Gross Weight

Kg

251

252

253

Compressor Quantity

1

1

1

2

Condenser Fan Quantity

1

1

1

1

Model Power Supply

AC3Φ380V~415V/50/60Hz

AVWT-154UKSTA

AVWT-170UKSTA

AVWT-190UKS1A

AVWT-212UKS1A

AC3Φ208~230V/60Hz

AVWT-154U8STA

AVWT-170U8STA

AVWT-190U8S1A

AVWT-212U8S1A

63.0

69.0

Nominal Capacity Heating Operation

KBtu/h

170.6

191.1

215.0

235.4

Power Consumption kW

12.29

13.97

16.41

19.11

COP

4.07

4.01

3.84

3.61

11,700

14,400

15,300

16,200

331

Net Weight

Kg

332

333

394

395

353

Gross Weight

Kg

354

355

415

416

Compressor Quantity

2

2

2

2

Condenser Fan Quantity

1

1

2

2

Ivory White

Cabinet Color

16

19

23

165(190*)

165(190*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

15(30*)

15(30*)

15(30*)

15(30*)

63/64

65/65

65/66

66/68

-20~16.5

56.0

1,730×1,350×750

165(190*)

C WB

3.06

50.0

kW

1,930×1,420×790

13

o

20.10

3.41

1,730×1,350×750

165(190*)

Heating

16.42

3.48

1,930×1,420×790

Ф12.7

-5~52*

14.37

3.57

1,730×1,210×750

Ф25.4

C DB

12.61

EER

1,930×1,275×790

Ф12.7

o

Power Consumption kW

1,730×1,210×750

Ф25.4

Cooling

Cooling Operation

1,930×1,275×790

Ф9.53

dB(A)

209.8

mm

Ф22.2

Noise Level (208~230V/380~415V)

61.5

191.1

mm

Ф9.53

m

56.0

170.6

Packing Dimension (H×W×D)

Ф19.05

Between IDUs

50.0

153.5

Outer Dimension (H×W×D)

mm

Between ODU&IDU m

45.0

KBtu/h

1,730×1,210×750

mm

m

kW

Nominal Capacity

1,930×1,275×790

Liquid Line

Max. Piping Length

Operation Range

22HP

m³/h

Gas Line

Max. number of connectable IDU

Height Difference

20HP

Air Flow Rate

Ivory White

Cabinet Color Refrigerant Piping

18HP

Combination Nominal Capacity

Cooling Operation

16HP

HP

Hi-FLEXi G+ Series

Refrigerant Piping

Gas Line

mm

Ф28.6

Ф28.6

Ф28.6

Ф28.6

Liquid Line

mm

Ф12.7

Ф15.88

Ф15.88

φ15.88

Max. number of connectable IDU m

Max. Piping Length Height Difference

Between ODU&IDU m Between IDUs

Noise Level (208~230V/380~415V) Operation Range

m dB(A)

26

26

33

36

165(190*)

165(190*)

165(190*)

165(190*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

15(30*)

15(30*)

15(30*)

15(30*)

66/68

67/68

69/69

69/69

Cooling

o

C DB

-5~52*

Heating

o

C WB

-20~16.5

Notes:

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more

4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more

than 15m, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.

than 15m, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.

51/52

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

HP

Hi-FLEXi G+ Series Model Power Supply

AC3Φ208~230V/60Hz

Nominal Capacity

28HP

30HP

32HP

kW KBtu/h

AVWT-232U8SZA AVWT-250U8SZA AVWT-268U8SZA AVWT-287U8SZA AVWT-306U8SZA AVWT-324U8SZA AVWT-96U*

AVWT-114U*

AVWT-114U*

AVWT-96U*

AVWT-114U*

AVWT-154U*

AVWT-136U*

AVWT-136U*

AVWT-154U*

AVWT-190U*

AVWT-190U*

AVWT-170U*

68.0

73.5

78.5

84.0

89.5

95

232.0

250.8

267.8

286.6

305.4

324.1

17.56

19.27

21.26

23.37

25.08

26.97

EER

3.87

3.81

3.69

3.59

3.57

3.52

kW

76.5

82.5

87.5

94.5

100.5

106.0

KBtu/h

261.0

281.5

298.6

322.4

342.9

361.7

Power Consumption kW

16.3

18.0

20.3

22.8

24.5

26.25

COP

4.71

4.59

4.30

4.15

4.11

4.04

21,900

22,200

22,200

25,500

25,800

26,100

Air Flow Rate

m³/h

Outer Dimension (H×W×D)

mm

1,730×(950+1,210)×750

1,730×(950+1,350)×750

Packing Dimension (H×W×D)

mm

1,930×(1,015+1,275)×790

1,930×(1,015+1,420)×790

Net Weight

Kg

571

572

573

634

635

Gross Weight

Kg

605

606

607

667

Compressor Quantity

3

3

3

Condenser Fan Quantity

2

2

2

Height Difference

Operation Range

AVWT-190U*

AVWT-212U*

AVWT-190U*

AVWT-212U*

AVWT-212U*

100

106.5

112

117.5

123

341.2

363.4

382.1

400.9

419.7

28.74

32.70

32.84

36.52

40.20

3.48

3.26

3.41

3.22

3.06

kW

112.0

119.0

126.0

132.0

138.0

KBtu/h

382.1

406.0

429.9

450.4

470.9

Power Consumption kW

27.9

31.4

32.8

35.5

38.2

COP

4.01

3.79

3.84

3.72

3.61

28,800

27,900

30,600

31,500

32,400

789

790

668

709

Gross Weight

Kg

710

770

830

831

832

3

3

4

Compressor Quantity

4

4

4

4

4

3

3

2

Condenser Fan Quantity

2

3

4

4

4

40

43

47

50

53

56

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

68/69

69/70

71/73

72/73

72/73

72/73

Refrigerant Piping

mm

Ф38.1

Ф38.1

Ф38.1

Ф38.1

Ф38.1

Liquid Line

mm

Ф19.05

Ф19.05

Ф19.05

Ф19.05

Ф19.05

m

Max. Piping Length

Between ODU&IDU m Between IDUs

Noise Level (208~230V/380~415V) Operation Range

m dB(A)

59

64

64

64

64

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

72/73

72/73

74/74

74/74

74/74

Cooling

o

C DB

-5~52*

Heating

o

C WB

-20~16.5

Notes:

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

1,930×(1,420+1,420)×790

Gas Line

Max. number of connectable IDU

Height Difference

1,730×(1,350+1,350)×750

Ivory White

Cabinet Color Ф38.1

-20~16.5

AVWT-190U*

AVWT-212U*

788

Ф19.05

C WB

AVWT-154U*

AVWT-170U*

727

Ф31.75

o

AVWT-170U*

666

Ф19.05

Heating

AVWT-420U8SZA

Kg

Ф31.75

-5~52*

Nominal Capacity Heating Operation

AVWT-398U8SZA

Net Weight

Ф19.05

C DB

EER

AVWT-382U8SZA

665

Ф31.75

o

Power Consumption kW

AVWT-364U8SZA

1,730×(1,210+1,210)×750 1,730×(1,210+1,350)×750

Ф19.05

Cooling

Cooling Operation

AVWT-420UKSZA

1,930×(1,275+1,275)×790 1,930×(1,275+1,420)×790

Ф31.75

dB(A)

AVWT-340U8SZA

KBtu/h

AVWT-398UKSZA

mm

Ф19.05

Noise Level (208~230V/380~415V)

AC3Φ208~230V/60Hz

Nominal Capacity

AVWT-382UKSZA

mm

Ф28.6

m

AVWT-364UKSZA

Packing Dimension (H×W×D)

Ф15.88

Between IDUs

AVWT-340UKSZA

kW

44HP

Outer Dimension (H×W×D)

mm

Between ODU&IDU m

AC3Φ380V~415V/50/60Hz

Combination

42HP

1,730×(1,210+1,210)×750

mm

m

Model Power Supply

40HP

1,930×(1,275+1,275)×790

Liquid Line

Max. Piping Length

38HP

m³/h

Gas Line

Max. number of connectable IDU

36HP

HP

Hi-FLEXi G+ Series

Air Flow Rate

Ivory White

Cabinet Color Refrigerant Piping

34HP

Power Consumption kW

Nominal Capacity Heating Operation

26HP

AC3Φ380V~415V/50/60Hz AVWT-232UKSZA AVWT-250UKSZA AVWT-268UKSZA AVWT-287UKSZA AVWT-306UKSZA AVWT-324UKSZA

Combination

Cooling Operation

24HP

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7℃ DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more

4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more

than 15m, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.

than 15m, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.

53/54

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

Hi-FLEXi G+ Series Model Power Supply

HP

50HP

52HP

54HP AVWT-510UKSZA

AC3Φ208~230V/60Hz

AVWT-494U8SZA

AVWT-510U8SZA

AVWT-438U8SZA AVWT-454U8SZA AVWT-476U8SZA

Model Power Supply

HP

AC3Φ208~230V/60Hz

AVWT-114U*

AVWT-170U*

AVWT-154U*

AVWT-170U*

AVWT-170U*

AVWT-170U*

AVWT-190U*

AVWT-212U*

AVWT-170U*

AVWT-170U*

AVWT-170U*

AVWT-190U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-170U*

AVWT-170U*

AVWT-212U*

AVWT-212U*

AVWT-170U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

kW

156.5

161.5

167.5

173

179

184.5

KBtu/h

534.0

551.0

571.5

590.3

610.7

629.5

Power Consumption kW

47.07

48.83

50.89

54.56

56.62

60.29

EER

3.32

3.31

3.29

3.17

3.16

3.06

kW

175.0

181.0

188.0

194.0

201.0

207.0

KBtu/h

706.3

140

145.0

150

494.7

511.8

Power Consumption kW

35.63

37.39

41.36

43.12

43.10

EER

3.61

3.57

3.38

3.36

3.48

kW

143.5

149.5

156.5

162.5

168.0

KBtu/h

489.6

510.1

534.0

554.5

573.2

Power Consumption kW

34.3

35.99

39.5

41.1

41.9

COP

4.18

4.15

3.97

3.95

4.01

39,300

38,400

41,100

Combination

Nominal Capacity Cooling Operation

Nominal Capacity Heating Operation

597.1

617.6

641.5

661.9

685.8

Power Consumption kW

45.4

47.0

49.5

52.2

54.6

57.3

COP

3.86

3.85

3.80

3.72

3.68

3.61

42,300

45,000

45,900

46,800

47,700

48,600

m³/h

36,600

Air Flow Rate

m³/h

Outer Dimension (H×W×D)

mm

1,730×(950+1,210+1,210)×750

1,730×(950+12,10+1,350)×750

1,730×(1,210+1,210+1,210)×750

Outer Dimension (H×W×D)

mm

Packing Dimension (H×W×D)

mm

1,930×(1,015+1,275+1,275)×790

1,930×(1,015+1,275+1,420)×790

1,930×(1,275+1,275+1,275)×790

Packing Dimension (H×W×D)

Net Weight

Kg

906

907

968

969

999

Net Weight

Gross Weight

Kg

962

963

1,023

1,024

1,065

Gross Weight

Compressor Quantity

5

5

5

5

6

Condenser Fan Quantity

3

3

4

4

3

Height Difference

m Between ODU&IDU m Between IDUs

Noise Level (208~230V/380~415V) Operation Range

43,200

Ivory White

Cabinet Color

Max. Piping Length

m dB(A)

AVWT-534U8SZA AVWT-551U8SZA AVWT-572U8SZA AVWT-590U8SZA AVWT-611U8SZA AVWT-630U8SZA

AVWT-170U*

477.7

Max. number of connectable IDU

66HP

AVWT-114U*

133.5

mm

64HP

AVWT-154U*

455.5

mm

62HP

AVWT-114U*

128.5

Liquid Line

60HP

AVWT-170U*

438.4

Gas Line

58HP

AC3Φ380V~415V/50/60Hz AVWT-534UKSZA AVWT-551UKSZA AVWT-572UKSZA AVWT-590UKSZA AVWT-611UKSZA AVWT-630UKSZA

Air Flow Rate

Refrigerant Piping

56HP

AVWT-114U*

KBtu/h

Nominal Capacity

Hi-FLEXi G+ Series

AVWT-154U* kW

Nominal Capacity

Heating Operation

48HP

AC3Φ380V~415V/50/60Hz AVWT-438UKSZA AVWT-454UKSZA AVWT-476UKSZA AVWT-494UKSZA

Combination

Cooling Operation

46HP

Ф41.3

Ф41.3

Ф41.3

Ф41.3

Ф41.3

Ф22.2

Ф22.2

Ф22.2

Ф22.2

64

64

64

64

64

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

74/75

74/75

74/75

74/75

75/75

o

C DB

-5~52*

Heating

o

C WB

-20~16.5

1,730×(1,210+1,350+1,350)×750

1,730×(1,350+1,350+1,350)×750

mm

1,930×(1,275+1,275+1,420)×790

1,930×(1,210+1,420+1,420)×790

1,930×(1,420+1,420+1,420)×790

Kg

1,060

1,061

1,122

1,123

1,184

1,185

Kg

1,125

1,126

1,186

1,187

1,247

1,248

Compressor Quantity

6

6

6

6

6

6

Condenser Fan Quantity

4

4

5

5

6

6

Ivory White

Cabinet Color

Ф22.2

Cooling

1,730×(1,210+1,210+1,350)×750

Refrigerant Piping

Gas Line

mm

Ф41.3

Ф44.5

Ф44.5

Ф44.5

Ф44.5

Ф44.5

Liquid Line

mm

Ф22.2

Ф22.2

Ф22.2

Ф22.2

Ф22.2

Ф22.2

64

64

64

64

64

64

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

Max. number of connectable IDU m

Max. Piping Length Height Difference

Between ODU&IDU m Between IDUs

Noise Level (208~230V/380~415V) Operation Range

m dB(A)

50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

75/76

75/76

76/76

76/76

76/76

76/76

Cooling

o

C DB

-5~52*

Heating

o

C WB

-20~16.5

Notes:

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more

4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more

than 15m, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.

than 15m, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.

55/56

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

72HP

74HP

76HP

AC3Φ380V~415V/50/60Hz AVWT-649UKSZA AVWT-666UKSZA

AVWT-688UKSZA

AVWT-705UKSZA

AVWT-722UKSZA

AVWT-742UKSZA

AVWT-649U8SZA AVWT-666U8SZA

AVWT-688U8SZA

AVWT-705U8SZA

AVWT-722U8SZA

AVWT-742U8SZA

AVWT-114U*

AVWT-114U*

AVWT-170U*

Hi-FLEXi G+ Series Model Power Supply

HP

AC3Φ208~230V/60Hz

68HP

AVWT-114U*

AC3Φ380V~415V/50/60Hz

AVWT-761UKSZA

AVWT-782UKSZA

AVWT-800UKSZA

AVWT-821UKSZA

AVWT-840UKSZA

AC3Φ208~230V/60Hz

AVWT-761U8SZA

AVWT-782U8SZA

AVWT-800U8SZA

AVWT-821U8SZA

AVWT-840U8SZA

AVWT-170U*

AVWT-170U*

AVWT-170U*

AVWT-170U*

AVWT-190U*

AVWT-212U*

AVWT-170U*

AVWT-190U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

223

229

234.5

240.5

246

760.9

781.3

800.1

820.6

839.4

Power Consumption kW

68.93

70.99

74.66

76.72

80.39

EER

3.24

3.23

3.14

3.13

3.06

kW

250.0

257.0

263.0

270.0

276.0

KBtu/h

AVWT-170U*

AVWT-170U*

AVWT-170U*

AVWT-212U*

AVWT-170U*

AVWT-190U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

AVWT-212U*

190

195

201.5

206.5

211.5

217.5

648.3

665.3

687.5

704.6

721.6

742.1

Power Consumption kW

57.51

57.49

61.46

63.22

63.20

65.26

EER

3.30

3.39

3.28

3.27

3.35

3.33

kW

212.5

218.5

225.5

231.5

237.0

244.0

KBtu/h

725.1

745.5

769.4

789.9

808.6

832.5

Power Consumption kW

53.4

55.1

58.6

60.2

61.0

63.4

COP

3.98

3.97

3.85

3.84

3.88

3.85

54,600

57,300

59,400

60,300

m³/h

52,800

55,500

Outer Dimension (H×W×D)

mm

Packing Dimension (H×W×D)

mm

1,730×(950+1,210 +1,210+1,350)×750 1,930×(1,015+1,275 +1,275+1,420)×790

Net Weight

Kg

1,730×(950+1,210 +1,210+1,350)×750 1,930×(1,015+1,275 +1,275+1,420)×790

1,301

1,302

1,363

1,364

1,394

Gross Weight

Kg

1,378

1,379

1,439

1,440

Compressor Quantity

7

7

7

Condenser Fan Quantity

5

5

6

63,000

63,900

64,800

1,579

1,580

Gross Weight

Kg

1,542

1,602

1,603

1,663

1,664

7

8

8

Compressor Quantity

8

8

8

8

8

6

5

6

Condenser Fan Quantity

6

7

7

8

8

1,730×(1,210+1,350+1,350+1,350)×750

1,730×(1,350+1,350+1,350+1,350)×750

1,930×(1,275+1,420+1,420+1,420)×790

1,930×(1,420+1,420+1,420+1,420)×790

Ivory White

Cabinet Color Ф25.4

Ф25.4

64

64

64

64

64

64

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

76/77

76/77

76/77

76/77

76/77

76/77

-20~16.5

3.61

62,100

1,541

Ф25.4

C WB

3.66

1,481

Ф25.4

o

3.69

1,518

Ф25.4

Heating

3.75

1,517

Ф25.4

-5~52*

3.78

1,456

Liquid Line

C DB

76.5

COP

Kg

Ф50.8

o

941.7

73.7

Net Weight

Ф50.8

Cooling

921.2

71.3

1,455

Ф50.8

dB(A)

897.4

68.6

mm

Ф50.8

Noise Level (208~230V/380~415V)

876.9

66.2

Packing Dimension (H×W×D)

1,930×(1,015+1,210+1,420+1,420)×790

Ф50.8

m

853.0

Power Consumption kW

1,730×(1,210+1,210 +1,350+1,350)×750 1,930×(1,275+1,275 +1,420+1,420)×790

Ф50.8

Between IDUs

Nominal Capacity Heating Operation

mm

mm

Between ODU&IDU m

Cooling Operation

KBtu/h

Outer Dimension (H×W×D)

1,730×(1,210+1,210 1,730×(1,210+1,210 +1,210+1,350)×750 +1,350+1,350)×750 1,930×(1,275+1,275 1,930×(1,275+1,275 +1,275+1,420)×790 +1,420+1,420)×790

mm

m

Nominal Capacity

kW

61,200

Gas Line

Max. Piping Length

Combination

m³/h

Ivory White

Max. number of connectable IDU

Model Power Supply

Air Flow Rate

1,730×(950+1,210+1,350+1,350)×750

Cabinet Color

Operation Range

88HP

AVWT-212U*

Air Flow Rate

Height Difference

86HP

AVWT-154U*

Nominal Capacity

Refrigerant Piping

84HP

AVWT-170U*

KBtu/h

HP

82HP

AVWT-170U*

kW

Hi-FLEXi G+ Series

80HP

AVWT-170U*

Nominal Capacity

Heating Operation

AVWT-114U*

78HP

AVWT-154U*

Combination

Cooling Operation

70HP

Refrigerant Piping

Gas Line

mm

Ф50.8

Ф50.8

Ф50.8

Ф50.8

Ф50.8

Liquid Line

mm

Ф25.4

Ф25.4

Ф25.4

Ф25.4

Ф25.4

64

64

64

64

64

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

77/77

77/77

77/77

77/77

77/77

Max. number of connectable IDU m

Max. Piping Length Height Difference

Between ODU&IDU m Between IDUs

Noise Level (208~230V/380~415V) Operation Range

m dB(A)

Cooling

o

C DB

-5~52*

Heating

o

C WB

-20~16.5

Notes:

Notes:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

1. Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more

4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more

than 15m, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.

than 15m, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.

57/58

OUTDOOR UNIT

Hi-FLEXi

Product Line

Super-long Piping Conditions, More Convenient Design

X Series

Max. piping length: 190m* Max. total piping length: 1000m

Height difference between outdoor and indoor unit Outdoor unit is higher: 90m* Outdoor unit is lower: 90m*

Hi-FLEXi X Series is equipped with large capacity full DC inverter compressor. The wide capacity range and compact structure design make it suitable for various place such as office building, shopping mall, hospital, school and so on.

Height difference between indoor units: 30m* Max. piping length between 1st branch and indoor unit: 90m

High efficiency and large capacity scroll compressor Latest DC inverter-driven technology Stepless fan speed regulation technology Smart and accurate unit capacity allocation technology

Note: For data marked by ※, please contact with our professional engineer.

Intelligent control mode

Layered Installation, Flexibly Corresponding to High-rise Buildings For high-rise buildings,machine layer can be left to place outdoor units ,or machine room can be set up on each floor,By using exhaust duct to exhaust the air ,with long distance supply air ,can effectively prevent short circuit of return air,ensure good ventilation and heat exchange effects of outdoor units.

Wide Operating Range

Temperature℃

46.9443

The system can run in a wide temperature range, the lowest temperature can reach -20oC WB,ensure a good heating effect in winter.

45.4512 43.9582 42.4651 40.9721 39.4790

-20oC WB

37.9859

+15oC WB

36.4929 34.9998

Heating operation range

Airflow Schematic

-5oC DB

-15

-5

5

15

25

35

Max. 85Pa

45

Layered installation effect picture

Extra-high external static pressure design

+52oC DB

Cooling operation range

-25

Exhaust duct installation

55

Max. 85Pa

The efficient axial fan is designed adopting CFD, finite element method, aviation dynamic fluid simulation analysis and other advanced concepts; its air inlet angle and outlet angle are optimized; together with unique horn air vent design, the external static pressure of outdoor unit is higher, which can better exhaust air and ensure smooth air flow. Adopt high-efficiency DC fan motor The use of high-efficiency fan reduces energy consumption of the motor Can achieve industry-leading level of external static pressure 85Pa

59/60

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

8/10HP

HP

Hi-FLEXi X Series

Model Power Supply AC3Φ380~415V/50Hz

8HP AVWT-76UESRX

12/14/16HP

10HP

18HP

12HP

14HP

20/22HP

16HP

18HP

AVWT-96UESRX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX AVWT-172UESZX AVWT-76UESRX

Combination

AVWT-96UESRX kW

22.4

28.0

33.5

40.0

45.0

50.4

KBtu/h

76.5

95.6

114.3

136.5

153.5

172.0

Power Consumption kW

5.25

7.31

8.57

11.05

13.16

12.56

EER

4.27

3.83

3.91

3.62

3.42

4.01

kW

25.0

31.5

37.5

45.0

50.0

56.5

KBtu/h

85.3

107.5

128.0

153.5

170.6

192.8

Power Consumption kW

5.62

7.61

8.89

11.08

12.47

13.23

COP

4.45

4.14

4.22

4.06

4.01

4.27

155

170

175

190

190

155+170

Cooling Capacity Cooling Operation

Heating Capacity Heating Operation

Air Flow Rate

m³/min

Outer Dimension (H×W×D)

mm

1,720×950×750

1,720×1,210×750

Packing Dimension (H×W×D)

mm

1,882×1,018×828

1,882×1,278×828

Net Weight

Kg

197

197

224

227

247

Gross Weight

Kg

223

223

248

250

272

Compressor Quantity

1

1

1

1

1

1+1

Condenser Fan Quantity

1

1

1

1

1

1+1

Refrigerant Piping

Operation Range

Height Difference

307.1

13.82

15.88

17.14

19.62

21.73

24.21

26.32

Power Consumption kW EER Heating Capacity

4.05

3.87

3.91

3.75

3.61

3.51

3.42

kW

62.5

69.0

75.0

82.5

87.5

95.0

100.0

KBtu/h

213.3

235.5

256.0

281.5

298.6

324.1

341.2

14.51

16.5

17.78

19.97

21.36

23.55

24.94

Power Consumption kW COP

4.31

4.18

4.22

4.13

4.10

4.03

4.01

155+175

170+175

175+175

175+190

175+190

190+190

190+190

197+224

197+224

224+224

224+227

224+247

227+247

247+247

223+248

248+248

248+250

248+272

250+272

272+272

Compressor Quantity

1+1

1+1

1+1

1+1

1+1

1+1

1+1

Condenser Fan Quantity

1+1

1+1

1+1

1+1

1+1

1+1

1+1

1,720×(950+1,210)×750

1,720×(1,210+1,210)×750

Ivory White

Cabinet Color Φ28.6

Φ28.6

Φ12.7

Φ15.88

13

16

19

23

26

26

dB(A)

62/54

64/55

64/56

65/57

66/58

66/57

-5~52*

Refrigerant Piping

190

190

190

Between ODU&IDU

m

50(40)

50(40)

50(40)

50(40)

50(40)

50(40)

Between IDUs

m

15

15

15

15

15

15

Gas Line

mm

Φ28.6

Φ28.6

Φ28.6

Φ31.75

Φ31.75

Φ31.75

Φ31.75

Liquid Line

mm

Φ15.88

Φ15.88

Φ15.88

Φ19.05

Φ19.05

Φ19.05

Φ19.05

Max.Indoor Unit Connectable dB(A)

Noise Level Operation Range

-20~15 190

90.0

290

223+248

Φ12.7

190

85.0

267.8

Kg

Φ25.4

190

78.5

250.8

Kg

Φ12.7

m

73.5

228.6

Gross Weight

Φ25.4

Max.Single piping length

67.0

209.8

Net Weight

Φ9.53

C

61.5

191.1

197+197

Φ22.2

o

56.0

KBtu/h

223+223

Φ9.53

HeatingMode

kW

mm

Φ19.05

C

32HP AVWT307UESZX

mm

mm

o

30HP AVWT290UESZX

Packing Dimension (H×W×D)

mm

Cooling Mode

28HP AVWT268UESZX

Outer Dimension (H×W×D)

1,720×(950+950)×750

Liquid Line

Noise Level

26HP AVWT250UESZX

AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX Cooling Capacity

Heating Operation

24HP AVWT229UESZX

AVWT-76UESRX AVWT-96UESRX AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX

Combination

Cooling Operation

22HP AVWT210UESZX

m³/min

Gas Line

Max.Indoor Unit Connectable

Model Power Supply AC3Φ380~415V/50Hz

20HP AVWT190UESZX

Air Flow Rate

Ivory White

Cabinet Color

HP

Hi-FLEXi X Series

24/26/28/30/32HP

36

40

43

47

50

53

68/60

68/60

68/60

69/61

69/61

69/62

Cooling Mode

o

C

-5~52*

HeatingMode

o

C

-20~15

Max.Single piping length Height Difference

33 68/60

m

Between ODU&IDU m Between IDUs

m

190

190

190

190

190

190

190

50(40)

50(40)

50(40)

50(40)

50(40)

50(40)

50(40)

15

15

15

15

15

15

15

Notes:

Notes:

1. Rated cooling capacity capacity is tested in the following conditions:

1. Rated cooling capacity capacity is tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.When the cooling operation temperature is over 52oC, please contact our professional engineer.

4.When the cooling operation temperature is over 52oC, please contact our professional engineer.

61/62

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

34HP HP

Hi-FLEXi X Series

Model Power Supply AC3Φ380~415V/50Hz Combination

Cooling Capacity Cooling Operation

44/46/48HP

34HP

36HP

38HP

40HP

42HP

AVWT-324UESZX

AVWT-343UESZX

AVWT-365UESZX

AVWT-386UESZX

AVWT-404UESZX

AVWT-96UESRX

AVWT-114UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-136UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-136UESSX AVWT-154UESSX

AVWT-154UESSX

96.0

100.5

107.0

113.0

118.5

327.6

342.9

365.1

385.6

404.3

Power Consumption kW

24.45

25.71

28.19

30.3

32.78

EER

3.93

3.91

3.80

3.73

3.62

kW

106.5

112.5

120.0

125.0

132.5

KBtu/h

363.5

384.0

409.5

426.6

452.1

25.39

26.67

28.86

30.25

32.44

4.19

4.22

4.16

4.13

4.08

170+175+175

175+175+175

175+175+190

175+175+190

175+190+190

Heating Capacity Heating Operation

kW

36/38/40/42HP

KBtu/h

Power Consumption kW COP

Air Flow Rate

m³/min

Outer Dimension (H×W×D)

mm

Packing Dimension (H×W×D)

mm

Net Weight

Kg

197+224+224

224+224+224

224+224+227

224+224+247

224+227+247

Gross Weight

Kg

1,720×(950+1,210+1,210)×750

1,720×(1,210+1,210+1,210)×750

HP

Hi-FLEXi X Series

Model Power Supply AC3Φ380~415V/50Hz Combination

44HP AVWT-420UESZX

50/52HP 46HP

48HP

AVWT-444UESZX

AVWT-460UESZX

50HP AVWT-480UESZX

52HP AVWT-500UESZX

AVWT-114UESSX

AVWT-136UESSX AVWT-154UESSX

AVWT-114UESSX AVWT-114UESSX

AVWT-154UESSX

AVWT-154UESSX AVWT-154UESSX

AVWT-114UESSX AVWT-114UESSX

AVWT-154UESSX

AVWT-154UESSX AVWT-154UESSX

AVWT-114UESSX AVWT-136UESSX AVWT-136UESSX AVWT-136UESSX

kW

123.5

130.0

135.0

140.4

146.0

KBtu/h

421.1

443.6

460.6

479

498.2

Power Consumption kW

34.89

37.37

39.48

36.76

39.24

EER

3.54

3.48

3.42

3.82

3.72

kW

137.5

145.0

150.0

156.5

163.0

KBtu/h

Cooling Capacity Cooling Operation

Heating Capacity Heating Operation

469.2

494.7

511.8

534.0

556.2

Power Consumption kW

33.83

36.02

37.41

37.75

39.94

COP

4.06

4.03

4.01

4.15

4.08

175+190+190

190+190+190

190+190+190

Air Flow Rate

m³/min

Outer Dimension (H×W×D)

mm

Packing Dimension (H×W×D)

mm

1,720×(1,210+1,210+1,210)×750

175+175+175+190 175+175+190+190 1,720×(1,210+1,210+1,210+1,210)×750

223+248+248

248+248+248

248+248+250

248+248+272

248+250+272

Net Weight

Kg

224+247+247

227+247+247

247+247+247

224+224+224+227 224+224+227+227

Compressor Quantity

1+1+1

1+1+1

1+1+1

1+1+1

1+1+1

Gross Weight

Kg

248+272+272

250+272+272

272+272+272

248+248+248+250 248+248+250+250

Condenser Fan Quantity

1+1+1

1+1+1

1+1+1

1+1+1

1+1+1

Compressor Quantity

1+1+1

1+1+1

1+1+1

1+1+1+1

1+1+1+1

Condenser Fan Quantity

1+1+1

1+1+1

1+1+1

1+1+1+1

1+1+1+1

Ivory White

Cabinet Color Refrigerant Piping

Gas Line Liquid Line

mm

Φ31.75

Φ38.1

Φ38.1

Φ38.1

Φ38.1

mm

Φ19.05

Φ19.05

Φ19.05

Φ19.05

Φ19.05

Max.Indoor Unit Connectable Noise Level Operation Range

dB(A)

59

64

64

64

70/63

70/63

71/64

71/64

71/64

Cooling Mode

o

C

-5~52*

HeatingMode

o

C

-20~15

Max.Single piping length Height Difference

56

m

Between ODU&IDU m Between IDUs

Refrigerant Piping

Gas Line

mm

Φ38.1

Φ38.1

Φ38.1

Φ41.3

Φ41.3

Liquid Line

mm

Φ19.05

Φ19.05

Φ19.05

Φ22.2

Φ22.2

Max.Indoor Unit Connectable dB(A)

Noise Level

190

190

190

190

190

50(40)

50(40)

50(40)

50(40)

50(40)

15

15

15

15

15

m

Ivory White

Cabinet Color

Operation Range

Cooling Mode

o

C

HeatingMode

o

C

Max.Single piping length Height Difference

m

Between ODU&IDU m Between IDUs

64

64

64

64

64

72/65

72/65

72/65

73/66

73/66

-5~52* -20~15 190

190

190

190

190

50(40)

50(40)

50(40)

50(40)

50(40)

15

15

15

15

15

m

Notes:

Notes:

1. Rated cooling capacity capacity is tested in the following conditions:

1. Rated cooling capacity capacity is tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.When the cooling operation temperature is over 52oC, please contact our professional engineer.

4.For 4 modular combination please contact manufacture for special design. 5.When the cooling operation temperature is over 52oC, please contact our professional engineer.

63/64

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

54HP 56HP

58HP

AVWT-520UESZX

AVWT-540UESZX

AVWT-560UESZX

AVWT-114UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-114UESSX

AVWT-136UESSX

AVWT-136UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

kW

151.5

157.0

163.5

KBtu/h

516.9

535.7

557.9

Power Consumption kW

41.35

43.46

45.94

EER

3.66

3.61

3.56

kW

169.0

175.0

182.5

KBtu/h

576.6

597.1

622.7

Power Consumption kW

41.33

42.72

44.91

COP

4.09

4.10

4.06

175+175+190+190

175+175+190+190

175+190+190+190

HP AC3Φ380V~415V/50Hz

Combination

Cooling Capacity Cooling Operation

Heating Capacity Heating Opeartion

60/62/64HP

54HP

Hi-FLEXi X Series Model Power Supply

56/58HP 60HP

62HP

64HP

AVWT-580UESZX

AVWT-600UESZX

AVWT-620UESZX

AVWT-114UESSX

AVWT-136UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

AVWT-154UESSX

kW

168.5

175.0

180.0

KBtu/h

574.9

597.1

614.2

Power Consumption kW

48.05

50.53

52.64

EER

3.51

3.46

3.42

kW

187.5

195.0

200.0

KBtu/h

Hi-FLEXi X Series Model Power Supply

HP AC3Φ380V~415V/50Hz

Combination

Cooling Capacity Cooling Operation

Heating Capacity Heating Operation

639.8

665.3

682.4

Power Consumption kW

46.3

48.49

49.88

COP

4.05

4.02

4.01

175+190+190+190

190+190+190+190

190+190+190+190

Air Flow Rate

m³/min

Outer Dimension (H×W×D)

mm

Packing Dimension (H×W×D)

mm

-

-

-

224+227+247+247

Net Weight

Kg

224+247+247+247

227+247+247+247

247+247+247+247

Gross Weight

Kg

Air Flow Rate

m³/min

Outer Dimension (H×W×D)

mm

1,720×(1,210+1,210+1,210+1,210)×750

Packing Dimension (H×W×D)

mm

-

-

-

Net Weight

Kg

224+224+227+247

224+224+247+247

Gross Weight

Kg

1,720×(1,210+1,210+1,210+12,10)×750

1,720×(1,210+1,210+1,210+1,210)×750

248+248+250+272

248+248+272+272

248+250+272+272

248+272+272+272

250+272+272+272

272+272+272+272

Compressor Quantity

1+1+1+1

1+1+1+1

1+1+1+1

Compressor Quantity

1+1+1+1

1+1+1+1

1+1+1+1

Condenser Fan Quantity

1+1+1+1

1+1+1+1

1+1+1+1

Condenser Fan Quantity

1+1+1+1

1+1+1+1

1+1+1+1

Ivory White

Cabinet Color Refrigerant Piping

Gas Line

mm

Φ41.3

Φ41.3

Φ44.5

Liquid Line

mm

Φ22.2

Φ22.2

Φ22.2

Max.Indoor Unit Connectable Noise Level Operation Range

dB(A) Cooling Mode

o

HeatingMode

o

Max.Single piping length Height Difference

64

64

73/66

74/67

-5~52*

m

Refrigerant Piping

190

190

190

50(40)

50(40)

50(40)

15

15

15

Gas Line

mm

Φ44.5

Φ44.5

Φ44.5

Liquid Line

mm

Φ22.2

Φ22.2

Φ22.2

64

64

64

dB(A)

74/67

74/67

74/67

Max.Indoor Unit Connectable Noise Level Operation Range

-20~15

C

m

Between ODU&IDU m Between IDUs

64 73/66

C

Ivory White

Cabinet Color

Cooling Mode

o

C

HeatingMode

o

C

Max.Single piping length Height Difference

m

Between ODU&IDU m Between IDUs

m

Notes:

Notes:

1. Rated cooling capacity capacity is tested in the following conditions:

1. Rated cooling capacity capacity is tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m

-5~52* -20~15 190

190

190

50(40)

50(40)

50(40)

15

15

15

Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.

3.The final appearance of outdoor units is subject to the actual products.

3.The final appearance of outdoor units is subject to the actual products.

4.For 4 modular combination please contact manufacture for special design.

4.For 4 modular combination please contact manufacture for special design.

5.When the cooling operation temperature is over 52oC, please contact our professional engineer.

5.When the cooling operation temperature is over 52oC, please contact our professional engineer.

65/66

OUTDOOR UNIT

Hi-FLEXi

Product Line Cooling Domination Mode

R Series

Hisense Hi-FLEXi R Series heat recovery air conditioning systems can realize simultaneous cooling and heating operation within one refrigerating system, which not only contributes to energy conservation but also meets various requirements of different consumers.

High efficiency scroll compressor Simultaneous cooling and heating Lastest inverter control technology Intelligent control system

Heat Recovery When total indoor heating load is less than cooling load,heat is being transferred from cooling room to heating room,part of heat exchanger is used as condenser to exhaust the redundant heat.

Heating Domination Mode

Exterior Zone of Building

Meeting various requirements of customers who are sensitive to temperature and diverse space with different function from the perspective of humanity especially at the transition season, like the complex of equipment rooms and offices, or the guest rooms and dining hall in the same hotel etc. The latest heat recovery multi-split system make season indoor units work in cooling and heating at the same time and being switched between two modes individually,which flexibly satisfies personalized need of different users.

When total indoor heating load is more than cooling load,heat is being transferred from cooling room to heating room,part of heat exchanger is used as evaporator to compensate the required heat.

67/68

OUTDOOR UNIT

Cooling/Heating Equilibrium Mode

Product Line

Extra-high External Static Pressure Design

Max. 60Pa

Adopt high-efficiency DC fan motor The use of high-efficiency fan reduces energy consumption of the motor Can achieve industry-leading level of external static pressure 60Pa

Max. 60Pa

If the ratio of cooling Load and heating load is 50:50,almost all the heat is moving among indoor units

The efficient axial fan is designed adopting CFD, finite element method, aviation dynamic fluid simulation analysis and other advanced concepts; its air inlet angle and outlet angle are optimized; together with unique horn air vent design, the external static pressure of outdoor unit is higher, which can better exhaust air and ensure smooth air flow.

Layered Installation, Flexibly Corresponding to High-rise Buildings

Configuration of Heat Recovery Operation System Hi-FLEXi R Series heat recovery operation system is composed of heat recovery outdoor unit, indoor unit, switch box, branch pipes and refrigerant pipes. One switch box unit could connect to one or multiple indoor units. The indoor units equipped with a same switch box unit will keep the same operation mode.

For high-rise buildings, crawl space can be left to place outdoor units, or machine room can be set up on each floor. By using exhaust duct to exhaust the air, short circuit of return air can be avoided with long exhaust distance, which ensures good ventilation and heat exchange effects of outdoor units.

Temperature ℃ 46.9443 45.4512 43.9582 42.4651 40.9721 39.4790 37.9859 36.4929 34.9998

Airflow Schematic

Exhaust duct installation

Layered installation effect picture

69/70

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

8/10/12HP HP

Hi-FLEXi R Series Model Power Supply

8HP

10HP

12HP

14/16/18HP 14HP

16HP

20HP 18HP

AC3Φ380~415V/50Hz

AVWT-76FESR AVWT-96FESR AVWT-114FESR AVWT-136FESS AVWT-154FESS AVWT-170FESS

AC3Φ380V/60Hz

AVWT-76F7SR AVWT-96F7SR AVWT-114F7SR AVWT-136F7SS AVWT-154F7SS AVWT-170F7SS

AC3Φ220V/60Hz

AVWT-76F9SR AVWT-96F9SR AVWT-114F9SR AVWT-136F9SS AVWT-154F9SS AVWT-170F9SS

Combination Nominal Capacity Cooling Operation

kW

22.4

28.0

33.5

40.0

45.0

50.0

KBtu/h

76.5

95.5

114.3

136.5

153.5

170.6

kW

5.65

7.65

10.18

12.25

13.74

16.60

3.96

3.66

3.29

3.27

3.28

3.01

25.0

31.5

37.5

45.0

50.0

56.0

Power Consumption EER Nominal Capacity

Heating Operation

kW KBtu/h kW

Power Consumption COP

Air Flow Rate

m³/h

Outer Dimensions (H×W×D)

mm

Packing Dimension (H×W×D)

mm

Net Weight

Kg

Gross Weight

Kg

Compressor Quantity Condenser Fan Quantity

85.3

107.5

128.0

Heat Recovery Operation System

7.76

10.12

11.30

12.60

15.30

4.06

3.71

3.98

3.97

3.66

9,300 1,720×950×750

10,200 1,720×950×750

10,500 1,720×950×750

11,700

11,700

1,720×1,210×750 1,720×1,210×750 1,720×1,210×750

1,828×1,018×824 1,828×1,018×824 1,828×1,018×824 1,882×1,278×824 1,882×1,278×824 1,882×1,278×824 225

227

246

298

312

318

235

237

255

310

325

330

1

1

1

2

2

2

1

1

1

1

1

Ivory White

Gas Line

mm

Ф19.05

Ф22.2

Ф25.4

Ф25.4

Ф28.6

Ф28.6

Liquid Line

mm

Ф9.53

Ф9.53

Ф12.7

Ф12.7

Ф12.7

Ф15.88

Liquid Line Low Pressure Gas Line High Pressure Gas Line

Max. Piping Length

mm

Ф9.53

Ф9.53

Ф12.7

Ф12.7

Ф12.7

Ф15.88

mm

Ф19.05

Ф22.2

Ф25.4

Ф25.4

Ф28.6

Ф28.6

mm

Ф15.88

Ф19.05

Ф22.2

Ф22.2

Ф22.2

Ф22.2

13.0

16.0

19.0

23.0

26.0

26.0

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

m Between ODU and IDU

m

Between IDUs

m

15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

15(30*)

dB(A)

58

58

60

62

62

63

Noise Level Operation Range

11,700

Cooling

o

Heating

o

50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)

C DB

-5~48

C WB

-20~15.5

NOTES: 1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) Outdoor Air Inlet Temperature: 35oC DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20oC DB(68°F DB), Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB)

22HP

24HP

AVWT-190FESZ

AVWT-212FESZ

AVWT-232FESZ

AVWT-250FESZ

AC3Φ380V/60Hz

AVWT-190F7SZ

AVWT-212F7SZ

AVWT-232F7SZ

AVWT-250F7SZ

AC3Φ220V/60Hz

AVWT-190F9SZ

AVWT-212F9SZ

AVWT-232F9SZ

HP

AVWT-76FESR AVWT-114FESR

Combination Nominal Capacity Cooling Operation

Heating Operation

AVWT-96FESR AVWT-136FESS

AVWT-250F9SZ AVWT-114FESR AVWT-136FESS

56.0

61.5

69.0

73.0

KBtu/h

190.8

213.0

232.0

250.8

kW

15.83

17.90

19.90

22.43

3.54

3.44

3.47

3.25

kW

63.0

69.0

77.5

82.5

KBtu/h

213.3

239.0

261.0

281.5

kW

15.93

17.11

19.06

21.42

3.95

4.03

4.07

3.85

21,900

22,200

Power Consumption

Nominal Capacity

AVWT-76FESR AVWT-136FESS

26HP

kW

EER

191.1

4.30

1

Max. Connectable No. of Indoor Units

Height Difference

170.6

5.81

Cabinet Color Heat Pump Operation System

153.5

20HP

AC3Φ380~415V/50Hz

Hi-FLEXi R Series Model Power Supply

22/24/26HP

Power Consumption COP

Air Flow Rate

m³/h

19,800

21,000

Outer Dimensions (H×W×D)

mm

1,720×(950+950)×750

1,720×(950+1,210)×750

Packing Dimension (H×W×D)

mm

---

---

---

---

Net Weight

Kg

225+246

225+298

227+298

246+298

Gross Weight

Kg

1,720×(950+1,210)×750 1,720×(950+1,210)×750

235+255

235+310

237+310

255+310

Compressor Quantity

2

3

3

3

Condenser Fan Quantity

2

2

2

2

Cabinet Color Heat Pump Operation System Heat Recovery Operation System

Ivory White

Gas Line

mm

Ф28.6

Ф28.6

Ф28.6

Ф31.75

Liquid Line

mm

Ф15.88

Ф15.88

Ф15.88

Ф19.05

Liquid Line

mm

Ф15.88

Ф15.88

Ф15.88

Ф19.05

Low Pressure Gas Line

mm

Ф28.6

Ф28.6

Ф28.6

Ф31.75

High Pressure Gas Line

mm

Ф22.2

Ф25.4

Ф25.4

Ф25.4

33.0

36.0

40.0

43.0

165(190*)

165(190*)

Max. Connectable No. of Indoor Units m

165(190*)

165(190*)

Between ODU and IDU

m

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

Between IDUs

m

15(30*)

15(30*)

15(30*)

15(30*)

dB(A)

62

63

63

64

Max. Piping Length Height Difference Noise Level Operation Range

Cooling

o

Heating

o

C DB

-5~48

C WB

-20~15.5

NOTES: 2. The sound pressure is based on the following conditions.1 Meter from the unit service cover surface, and 1.5 Meter from floor level. The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2dB. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3. Except for the specified combination in the table, there is no other combination of the base unit. 4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm. 5. For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more than 15m, please contact our professional engineer.

1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) Outdoor Air Inlet Temperature: 35oC DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20oC DB(68°F DB), Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB)

2. The sound pressure is based on the following conditions.1 Meter from the unit service cover surface, and 1.5 Meter from floor level. The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2dB. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3. Except for the specified combination in the table, there is no other combination of the base unit. 4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm. 5. For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more than 15m, please contact our professional engineer.

71/72

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

28/30/32/34/36HP 28HP

30HP

32HP

34HP

36HP

AC3Φ380~415V/50Hz

AVWT-272FESZ

AVWT-290FESZ

AVWT-308FESZ

AVWT-324FESZ

AVWT-340FESZ

AC3Φ380V/60Hz

AVWT-272F7SZ

AVWT-290F7SZ

AVWT-308F7SZ

AVWT-324F7SZ

AVWT-340F7SZ

AC3Φ220V/60Hz

AVWT-272F9SZ

AVWT-290F9SZ

AVWT-308F9SZ

AVWT-324F9SZ

AVWT-340F9SZ

AVWT-136FESS AVWT-136FESS

AVWT-136FESS AVWT-154FESS

AVWT-154FESS AVWT-154FESS

AVWT-154FESS AVWT-170FESS

AVWT-170FESS AVWT-170FESS

HP

Hi-FLEXi R Series Model Power Supply Combination Nominal Capacity Cooling Operation

kW

80.0

85.0

90.0

95.0

100.0

KBtu/h

273.0

290.0

307.0

324.1

341.2

kW

24.50

25.99

27.48

30.34

33.20

3.27

3.27

3.28

3.13

3.01

kW

90.0

95.0

100.0

106.0

112.0

KBtu/h

307.1

324.1

341.2

361.7

382.1

kW

22.60

23.90

25.20

27.90

30.60

3.98

3.97

3.97

3.80

3.66

23,400

23,400

23,400

23,400

23,400

Power Consumption EER Nominal Capacity

Heating Operation

38/40/42HP

Power Consumption COP

Air Flow Rate

m³/h

Outer Dimensions (H×W×D)

mm

Packing Dimension (H×W×D)

mm

---

---

---

---

---

Net Weight

Kg

298+298

298+312

312+312

312+318

Gross Weight

Kg

38HP

40HP

42HP

AC3Φ380~415V/50Hz

HP

AVWT-364FESZ

AVWT-382FESZ

AVWT-398FESZ

AC3Φ380V/60Hz

AVWT-364F7SZ

AVWT-382F7SZ

AVWT-398F7SZ

AC3Φ220V/60Hz

AVWT-364F9SZ

AVWT-382F9SZ

AVWT-398F9SZ

AVWT-114FESR AVWT-114FESR AVWT-136FESS

AVWT-114FESR AVWT-114FESR AVWT-154FESS

AVWT-114FESR AVWT-114FESR AVWT-170FESS

Hi-FLEXi R Series

Model Power Supply Combination

Nominal Capacity Cooling Operation

kW

109.0

112.0

118.0

KBtu/h

365.1

382.1

399.2

kW

32.61

34.10

36.96

3.34

3.28

3.19

kW

118.0

125.0

132.0

KBtu/h

409.5

426.5

447.5

kW

31.54

32.84

35.54

3.74

3.81

3.71

Power Consumption EER Nominal Capacity

Heating Operation

Power Consumption COP

Air Flow Rate

m³/h

32,700

32,700

32,700

Outer Dimensions (H×W×D)

mm

1,720×(950+950+1,210)×750

1,720×(950+950+1,210)×750

1,720×(950+950+1,210)×750

Packing Dimension (H×W×D)

mm

---

---

---

318+318

Net Weight

Kg

246+246+298

246+246+312

246+246+318

Gross Weight

Kg

1,720×(1,210+1,210)×750 1,720×(1,210+1,210)×750 1,720×(1,210+1,210)×750 1,720×(1,210+1,210)×750 1,720×(1,210+1,210)×750

310+310

310+325

325+325

325+330

330+330

255+255+310

255+255+325

255+255+330

Compressor Quantity

4

4

4

4

4

Compressor Quantity

4

4

4

Condenser Fan Quantity

2

2

2

2

2

Condenser Fan Quantity

3

3

3

Cabinet Color Heat Pump Operation System Heat Recovery Operation System

Ivory White

Gas Line

mm

Ф31.75

Ф31.75

Ф31.75

Ф31.75

Ф38.1

Liquid Line

mm

Ф19.05

Ф19.05

Ф19.05

Ф19.05

Ф19.05

Liquid Line

mm

Ф19.05

Ф19.05

Ф19.05

Ф19.05

Ф19.05

Low Pressure Gas Line

mm

High Pressure Gas Line

mm

Max. Connectable No. of Indoor Units Max. Piping Length Height Difference

Between ODU and IDU

o

Heating

o

Ф31.75

Ф31.75

Ф31.75

Ф31.75

Ф28.6

Ф28.6

Ф28.6

Ф28.6

Ф28.6

47.0

50.0

53.0

56.0

59.0

m

165(190*)

165(190*)

165(190*)

165(190*)

165(190*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

dB(A) Cooling

Ф31.75

m m

Between IDUs

Noise Level Operation Range

Cabinet Color

15(30*)

15(30*)

65

65

15(30*)

15(30*)

15(30*)

65

66

66

C DB

-5~48

C WB

-20~15.5

NOTES: 1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) Outdoor Air Inlet Temperature: 35oC DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20oC DB(68°F DB), Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB)

Heat Pump Operation System Heat Recovery Operation System

Ivory White

Gas Line

mm

Ф38.1

Ф38.1

Ф38.1

Liquid Line

mm

Ф19.05

Ф19.05

Ф19.05

Liquid Line

mm

Ф19.05

Ф19.05

Ф19.05

mm

Ф38.1

Ф38.1

Ф38.1

mm

Ф31.75

Ф31.75

Ф31.75

64.0

64.0

64.0

165(190*)

165(190*)

Low Pressure Gas Line High Pressure Gas Line

Max. Connectable No. of Indoor Units m

165(190*)

Between ODU and IDU

m

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

Between IDUs

m

15(30*)

15(30*)

15(30*)

dB(A)

66

66

66

Max. Piping Length Height Difference Noise Level Operation Range

Cooling

o

Heating

o

C DB

-5~48

C WB

-20~15.5

NOTES: 2. The sound pressure is based on the following conditions.1 Meter from the unit service cover surface, and 1.5 Meter from floor level. The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2dB. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3. Except for the specified combination in the table, there is no other combination of the base unit. 4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm. 5. For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more than 15m, please contact our professional engineer.

1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) Outdoor Air Inlet Temperature: 35oC DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20oC DB(68°F DB), Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB)

2. The sound pressure is based on the following conditions.1 Meter from the unit service cover surface, and 1.5 Meter from floor level. The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2dB. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3. Except for the specified combination in the table, there is no other combination of the base unit. 4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm. 5. For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more than 15m, please contact our professional engineer.

73/74

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

44/46/48HP HP

44HP

46HP

48HP

AC3Φ380~415V/50Hz

AVWT-420FESZ

AVWT-438FESZ

AVWT-454FESZ

AC3Φ380V/60Hz

AVWT-420F7SZ

AVWT-438F7SZ

AVWT-454F7SZ

AC3Φ220V/60Hz

AVWT-420F9SZ

AVWT-438F9SZ

AVWT-454F9SZ

AVWT-114FESR AVWT-136FESS AVWT-170FESS

AVWT-114FESR AVWT-154FESS AVWT-170FESS

AVWT-114FESR AVWT-170FESS AVWT-170FESS

Hi-FLEXi R Series

Model Power Supply Combination

Nominal Capacity Cooling Operation

kW

125.0

132.0

136.0

KBtu/h

421.4

438.4

455.5

kW

39.03

40.52

43.38

3.20

3.26

3.14

kW

140.0

145.0

150.0

KBtu/h

472.6

494.7

511.8

kW

36.72

38.02

40.72

3.81

3.81

3.68

33,900

33,900

33,900

Power Consumption EER Nominal Capacity

Heating Operationn

50/52/54HP

Power Consumption COP

145.0

477.7

494.7

511.8

kW

45.45

46.94

49.80

3.08

3.09

3.01

kW

155.0

160.0

165.0

KBtu/h

528.9

545.9

563.0

kW

41.90

43.20

45.90

3.70

3.70

3.59

Power Consumption EER Nominal Capacity

Heating Operation

Power Consumption COP

---

Net Weight

Kg

298+318+318

312+318+318

318+318+318

255+325+330

255+330+330

Gross Weight

Kg

310+330+330

325+330+330

330+330+330

5

5

Compressor Quantity

6

6

6

3

3

Condenser Fan Quantity

3

3

3

255+310+330

Compressor Quantity

5

Condenser Fan Quantity

3

Cabinet Color

Ivory White

mm

Ф38.1

Ф38.1

Ф38.1

Liquid Line

mm

Ф19.05

Ф19.05

Ф19.05

Liquid Line

mm

Ф19.05

Ф19.05

Ф19.05

mm

Ф38.1

Ф38.1

Ф38.1

mm

Ф31.75

Ф31.75

Ф31.75

64.0

64.0

64.0

165(190*)

165(190*)

m

165(190*)

Between ODU and IDU

m

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

Between IDUs

m

15(30*)

15(30*)

15(30*)

dB(A)

67

67

67

C DB

-5~48

C WB

-20~15.5

NOTES: 1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) Outdoor Air Inlet Temperature: 35oC DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20oC DB(68°F DB), Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB)

140.0

246+318+318

Kg

o

Cooling Operation

kW KBtu/h

(1,720×1,210×750)×3

Gross Weight

Heating

150.0

Nominal Capacity

---

246+312+318

Operation Range

AVWT-170FESS AVWT-170FESS AVWT-170FESS

(1,720×1,210×750)×3

246+298+318

o

AVWT-154FESS AVWT-170FESS AVWT-170FESS

---

Kg

Cooling

AVWT-510F9SZ

AVWT-136FESS AVWT-170FESS AVWT-170FESS

Combination

(1,720×1,210×750)×3

Net Weight

Noise Level

AVWT-510F7SZ

AVWT-494F9SZ

mm

---

Height Difference

AVWT-494F7SZ

AVWT-476F9SZ

mm

---

Max. Piping Length

AVWT-476F7SZ

AC3Φ220V/60Hz

Packing Dimension (H×W×D)

---

1,720×(950+1,210+1,210)×750 1,720×(950+1,210+1,210)×750 1,720×(950+1,210+1,210)×750

Max. Connectable No. of Indoor Units

AC3Φ380V/60Hz

Outer Dimensions (H×W×D)

mm

High Pressure Gas Line

Model Power Supply

35,100

mm

Low Pressure Gas Line

AVWT-510FESZ

35,100

Packing Dimension (H×W×D)

Heat Recovery Operation System

54HP

AVWT-494FESZ

35,100

Outer Dimensions (H×W×D)

Gas Line

52HP

AVWT-476FESZ

m³/h

m³/h

Cabinet Color

HP

Air Flow Rate

Air Flow Rate

Heat Pump Operation System

50HP

AC3Φ380~415V/50Hz

Hi-FLEXi R Series

Heat Pump Operation System Heat Recovery Operation System

Ivory White

Gas Line

mm

Ф38.1

Ф38.1

Ф38.1

Liquid Line

mm

Ф19.05

Ф19.05

Ф19.05

Liquid Line

mm

Ф19.05

Ф19.05

Ф19.05

mm

Ф38.1

Ф38.1

Ф38.1

mm

Ф31.75

Ф31.75

Ф31.75

64.0

64.0

64.0

165(190*)

165(190*)

Low Pressure Gas Line High Pressure Gas Line

Max. Connectable No. of Indoor Units m

165(190*)

Between ODU and IDU

m

50(90*)/40(90*)

50(90*)/40(90*)

50(90*)/40(90*)

Between IDUs

m

15(30*)

15(30*)

15(30*)

dB(A)

67

67

68

Max. Piping Length Height Difference Noise Level Operation Range

Cooling

o

Heating

o

C DB

-5~48

C WB

-20~15.5

NOTES: 2. The sound pressure is based on the following conditions.1 Meter from the unit service cover surface, and 1.5 Meter from floor level. The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2dB. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3. Except for the specified combination in the table, there is no other combination of the base unit. 4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm. 5. For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more than 15m, please contact our professional engineer.

1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) Outdoor Air Inlet Temperature: 35oC DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20oC DB(68°F DB), Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB)

2. The sound pressure is based on the following conditions.1 Meter from the unit service cover surface, and 1.5 Meter from floor level. The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2dB. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3. Except for the specified combination in the table, there is no other combination of the base unit. 4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm. 5. For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more than 15m, please contact our professional engineer.

75/76

OUTDOOR UNIT

Hi-FLEXi

W

Product Line

Indoor Installation, Not affected by weather conditions

Series

Heat Recovery

It is invisible from the outside,ensure the beautiful facade of the building. It is very suitable for sound sensitive areas because there is no external running sound.

Hi-FLEXi W Series Heat Recovery can keep simultaneous cooling and heating from one system. And it has a new switch box, which is designed to improve energy efficiency. The products are more flexible to meet users' demands.

It can operation normally even in the most extreme outside conditions, especially in geothermal operation. It has very high efficiency thanks to water cooled condenser. Indoor installation is more convenient and safer.

Simultaneous Cooling and Heating Convenient Installation 360° Fitted Refrigerant Cooling Technology

2-stage Heat Recovery

Simplify Installation Process

With 2-stage heat recovery from both refrigerant side and water source side, the heat recovery system realize energy saving at the greatest extent. Simultaneous cooling and heating in one system could be achieved.

Heat recovery between indoor units

Heat recovery between outdoor units

Heat exhausted from indoor unit in cooling mode could be transferred to the units which is in heating mode.

The outdoor unit of cooling mode exhaust heat into water , and the other outdoor unit of heating mode absorb heat from water. So the heat recovery between outdoor units could be achieved via the water pipe .

There is no need for ventilation in equipment room. Save time and simplify installation process because there is no need for installing air duct for water source outdoor unit.

Continuously Heating Without Defrosting Operation Heat Exhaust

Heat Exhaust

Heat Suction

Heat Exhaust

Best comfort because of no temperature fluctuations during heating operation. Continuously heating thanks to no defrosting during heating operation.

77/78

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

Hi-FLEXi W Series Heat Recovery Model Power Supply

Nominal Capacity*1 Cooling Operation

HP

Nominal Input

Heating Operation

Nominal Input

Packing Dimensions

12HP

14HP

AVWW-114FKFW

AVWW-136FKFW 40.0

KBtu/h

76.5

95.6

114.3

136.5

kW

3.85

5.04

6.32

7.84

5.82

5.55

5.30

5.10

kW

25.0

31.5

37.5

45.0

KBtu/h

85.3

107.5

128.0

153.6

kW

4.08

5.25

6.45

8.03

6.12

6.00

5.81

5.60

COP Height

mm

1030

1030

1030

1030

Width

mm

820

820

820

820

Depth

mm

560

560

560

560

Area



0.46

0.46

0.46

0.46

H×W×D

mm

1180×900×632

1180×900×632

1180×900×632

1180×900×632

50.0

56.0

63.0

KBtu/h

170.6

191.1

215.0

kW

8.33

9.62

10.86

6.00

5.82

5.80

mm

1030

1030

1030

Width

mm

1040

1040

1040

Depth

mm

560

560

560

Area



0.58

0.58

0.58

H×W×D

Nominal Input

246

175

175

Gross Weight

Kg

250

251

251

51/53

53/54

55/57

dB(A)

51/52

53/53

53/55

49/51

MAX. Piping Length*4

5.10

kW

1180×1112×632

dB(A)

MAX. Connectable Indoor Units

10.98

5.30

246

170

Water Connecting Pipes

9.43

1180×1112×632

170

Refrigerant Connecting Pipes

8.11

Sound Pressure Level *2

Cooling/Heating

°C

10~45

10~45

10~45

10~45

Water Temperature*3

L/min

76.7

96.0

115.0

138.3

Water Flow Rate

kPa

30

45

45

60

20

20

20

20

Water-Side Heat Exchanger

°C

10~45

10~45

10~45

L/min

153.3

166.7

193.3

kPa

40

45

60

kgf/cm2

20

20

20

Liquid Pipe

mm

Ф12.7

Ф15.88

Ф15.88

Low Pressure Gas Pipe

mm

Ф28.6

Ф28.6

Ф28.6

mm

Ф22.2

Ф22.2

Ф22.2

DN32

DN32

DN32

G1-1/4B

G1-1/4B

G1-1/4B

Water Pressure Drop Maximum Pressure Resistance

Liquid Pipe

mm

Ф9.53

Ф9.53

Ф12.7

Ф12.7

Low Pressure Gas Pipe

mm

Ф19.05

Ф22.2

Ф25.4

Ф25.4

High/Low Pressure Gas Pipe

mm

Ф15.88

Ф19.05

Ф22.2

Ф22.2

High/Low Pressure Gas Pipe

DN32

DN32

DN32

DN32

Water Pipe

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

Water Pipe Thread of Connector mm

Outer Diameter 18 Outer Diameter 18

Outer Diameter 18

Outer Diameter 18

Recommended

12

15

18

21

MAX.

19

24

29

34

300(500)

300(500)

300(500)

300(500)

Drain Pipe

m

kW

245

Kg

kgf/cm2

191.1

1180×1112×632

Gross Weight

Maximum Pressure Resistance

56.0

170.6

Kg

171

Water Pressure Drop

50.0

153.6

mm

166

Water-Side Heat Exchanger

45.0

KBtu/h

171

166

Water Flow Rate

Packing Dimensions

20HP AVWW-190FKFW

5.55

Nominal Input

Nominal Capacity*1

Outer Dimensions

18HP AVWW-170FKFW

kW

EER

Heating Operation

16HP AVWW-154FKFW

Net Weight

Kg

Water Temperature*3

Nominal Capacity*1 Cooling Operation

HP

AC 3Ф, 380 ~ 415V/50Hz(60Hz)

33.5

Height

Cooling/Heating

Model Power Supply

28.0

Net Weight Sound Pressure Level *2

Hi-FLEXi W Series Heat Recovery

22.4

COP

Outer Dimensions

10HP AVWW-96FKFW

kW

EER Nominal Capacity*1

8HP AVWW-76FKFW

AC 3Ф, 380 ~ 415V/50Hz(60Hz)

NOTES: *1. Operation Condition: Cooling:Indoor Temperature 27oC DB/19oC WB, Water Inlet/Outlet 30/35oC. Heating:Indoor Temperature 20oC DB/15oC WB, Water Inlet 20oC. *2. The sound pressure is based on the following conditions. 1 Meter from the unit service cover surface, and 1.5 Meters from floor level. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. *3. When unit is operating out of the allowable water temperature range, it won't strat normally and will alarm. *4. For Max.pipe length more than 300m, please contact our professional engineer.

Refrigerant Connecting Pipes

Water Connecting Pipes MAX. Connectable Indoor Units MAX. Piping Length*4

Thread of Connector mm

Outer Diameter 18

Outer Diameter 18

Outer Diameter 18

Recommended

23

26

29

MAX.

39

43

48

300(500)

300(500)

300(500)

Drain Pipe

m

79/80

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

Hi-FLEXi W Series Heat Recovery Model Power Supply

HP

AC 3Ф, 380 ~ 415V/50Hz(60Hz)

Cooling Operation

Nominal Input

Nominal Capacity*1 Nominal Input

Packing Dimensions

30HP

AVWW-210FKFW AVWW-228FKFW AVWW-250FKFW AVWW-268FKFW AVWW-286FKFW

61.5

67.0

73.5

78.5

84.0

209.9

228.6

250.8

267.9

286.7

kW

11.4

12.6

14.2

14.4

16.0

5.41

5.30

5.19

5.44

5.24

kW

69.0

75.0

82.5

87.5

94.5

KBtu/h

235.4

255.9

281.6

298.6

322.4

14.8

16.1

kW

11.7 5.90

H×W×D

mm

Area



H×W×D

28HP

kW

COP Outer Dimensions

26HP

KBtu/h

EER

Heating Operation

24HP

Hi-FLEXi W Series Heat Recovery Model Power Supply

AVWW-96FKFW AVWW-114FKFW AVWW-114FKFW AVWW-114FKFW AVWW-96FKFW AVWW-114FKFW AVWW-114FKFW AVWW-136FKFW AVWW-154FKFW AVWW-190FKFW

Combination Nominal Capacity*1

22HP

mm

12.9 5.81

14.5 5.70

5.92

0.9

0.9

0.9

1.0

AC 3Ф, 380 ~ 415V/50Hz(60Hz)

Nominal Capacity*1 Cooling Operation

Nominal Capacity*1 Heating Operation

Nominal Input

Packing Dimensions

38HP

40HP

AVWW-304FKFW AVWW-326FKFW AVWW-344FKFW AVWW-360FKFW AVWW-380FKFW

89.5

96.0

101.0

106.0

112.0

305.4

327.6

344.7

361.7

382.1

kW

17.3

18.8

19.1

20.4

22.0

5.17

5.10

5.29

5.19

5.10

kW

100.5

108.0

113.0

119.0

126.0

KBtu/h

342.9

368.6

385.6

406.0

429.9

kW

17.3

18.9

19.2

20.5

21.7

5.81

5.72

5.89

5.81

5.80

H×W×D

mm

Area



H×W×D

36HP

kW

COP Outer Dimensions

34HP

KBtu/h

EER

1.0

1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632 1180×900×632 1180×900×632 1180×1112×632 1180×1112×632

Nominal Input

32HP

AVWW-114FKFW AVWW-136FKFW AVWW-154FKFW AVWW-170FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW

Combination

5.87

1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560 1030×820×560 1030×820×560 1030×1040×560 1030×1040×560

HP

mm

1030×820×560+ 1030×1040×560

1.0

1030×820×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560

1.0

1.2

1.2

1.2

1180×900×632+ 1180×900×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632

Net Weight

Kg

337

342

342

416

412

Net Weight

Kg

417

417

491

492

Gross Weight

Kg

345

350

350

425

421

Gross Weight

Kg

426

426

501

502

502

dB(A)

56/57

56/57

58/60

56/57

56/58

dB(A)

56/58

58/60

56/58

56/58

56/58

°C

10~45

10~45

10~45

10~45

10~45

°C

10~45

10~45

10~45

10~45

10~45

L/min

211.0

230.0

253.3

268.3

289.3

L/min

308.3

331.7

346.7

360.0

386.7

kPa

/

/

/

/

/

kPa

/

/

/

/

/

kgf/cm2

20

20

20

20

20

kgf/cm2

20

20

20

20

20

Liquid Pipe

mm

Ф15.88

Ф15.88

Ф19.05

Ф19.05

Ф19.05

Liquid Pipe

mm

Ф19.05

Ф19.05

Ф19.05

Ф19.05

Ф19.05

Low Pressure Gas Pipe

mm

Ф28.6

Ф28.6

Ф31.75

Ф31.75

Ф31.75

Low Pressure Gas Pipe

mm

Ф31.75

Ф31.75

Ф31.75

Ф38.1

Ф38.1

High/Low Pressure Gas Pipe

mm

Ф25.4

Ф25.4

Ф25.4

Ф28.6

Ф28.6

High/Low Pressure Gas Pipe

mm

Ф28.6

Ф28.6

Ф28.6

Ф31.75

Ф31.75

Sound Pressure Level *2

Cooling/Heating Water Temperature*3

Water-Side Heat Exchanger

Water Flow Rate Water Pressure Drop Maximum Pressure Resistance

Refrigerant Connecting Pipes

Water Connecting Pipes MAX. Connectable Indoor Units MAX. Piping Length*4

Water Pipe Thread of Connector Drain Pipe

DN32

DN32

DN32

DN32

DN32

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

40

40

mm 33

Recommended MAX. m

36

Outer Diameter 18 39

53

58

63

64

64

300(500)

300(500)

300(500)

300(500)

300(500)

NOTES: *1. Operation Condition: Cooling:Indoor Temperature 27oC DB/19oC WB, Water Inlet/Outlet 30/35oC. Heating:Indoor Temperature 20oC DB/15oC WB, Water Inlet 20oC. *2. The sound pressure is based on the following conditions. 1 Meter from the unit service cover surface, and 1.5 Meters from floor level. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. *3. When unit is operating out of the allowable water temperature range, it won't strat normally and will alarm. *4. For Max.pipe length more than 300m, please contact our professional engineer.

Sound Pressure Level *2

Cooling/Heating Water Temperature*3

Water-Side Heat Exchanger

Water Flow Rate Water Pressure Drop Maximum Pressure Resistance

Refrigerant Connecting Pipes

Water Connecting Pipes MAX. Connectable Indoor Units MAX. Piping Length*4

Water Pipe Thread of Connector Drain Pipe

DN32

DN32

DN32

DN32

DN32

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

40

40

40

40

mm

Recommended MAX. m

492

Outer Diameter 18 40

64

64

64

64

64

300(500)

300(500)

300(500)

300(500)

300(500)

81/82

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

Hi-FLEXi W Series Heat Recovery Model Power Supply

HP

AC 3Ф, 380 ~ 415V/50Hz(60Hz)

Cooling Operation

Nominal Input

Heating Operation

Nominal Input

Packing Dimensions

50HP

117.5

123.0

129.0

134.0

140.0

KBtu/h

419.7

440.3

457.3

477.7

kW

22.3

23.6

24.1

25.5

27.0

5.26

5.21

5.35

5.27

5.19

kW

132.0

138.0

144.5

150.5

157.5

KBtu/h

450.4

470.9

493.0

513.5

537.4

kW

22.6

23.8

24.4

25.7

27.0

5.85

5.81

5.91

5.85

5.84

H×W×D

mm

Area



H×W×D

48HP

401.0

COP Outer Dimensions

46HP

kW

EER Nominal Capacity*1

44HP

mm

1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560

1.5 1180×900×632+ 1180×900×632+ 1180×1112×632

1.5

1.6

1.6

Model Power Supply

56HP

58HP

60HP

AVWW-516FKFW AVWW-136FKFW AVWW-190FKFW AVWW-190FKFW

AVWW-534FKFW AVWW-154FKFW AVWW-190FKFW AVWW-190FKFW

AVWW-550FKFW AVWW-170FKFW AVWW-190FKFW AVWW-190FKFW

AVWW-570FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW

kW

145.5

152.0

157.0

162.0

168.0

KBtu/h

496.4

518.6

535.7

552.7

573.2

kW

28.3

29.8

30.1

31.4

32.9

5.14

5.10

5.22

5.16

5.10

kW

163.5

171.0

176.0

182.0

189.0

KBtu/h

557.9

583.5

600.5

621.0

644.9

kW

28.2

29.8

30.1

31.3

32.6

5.80

5.75

5.86

5.81

HP

AC 3Ф, 380 ~ 415V/50Hz(60Hz) Combination

Nominal Capacity*1 Cooling Operation

Nominal Input EER Nominal Capacity*1

Heating Operation

Nominal Input COP

Outer Dimensions

1.6

1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632

54HP

AVWW-494FKFW AVWW-114FKFW AVWW-190FKFW AVWW-190FKFW

Hi-FLEXi W Series Heat Recovery

AVWW-96FKFW AVWW-114FKFW AVWW-96FKFW AVWW-96FKFW AVWW-96FKFW AVWW-114FKFW AVWW-114FKFW AVWW-154FKFW AVWW-170FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW

Combination

Nominal Capacity*1

42HP

AVWW-400FKFW AVWW-418FKFW AVWW-440FKFW AVWW-456FKFW AVWW-476FKFW

Packing Dimensions

H×W×D

mm

Area



H×W×D

mm

52HP

1030×820×560+ 1030×820×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560

1.6

1.6

1180×900×632+ 1180×900×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632 1180×1112×632

1.7 1180×1112×632+ 1180×1112×632+ 1180×1112×632

5.80 1030×1040×560+ 1030×1040×560+ 1030×1040×560

1.7

1.7

1180×1112×632+ 1180×1112×632+ 1180×1112×632

1180×1112×632+ 1180×1112×632+ 1180×1112×632

Net Weight

Kg

583

588

657

658

658

Net Weight

Kg

663

663

737

738

Gross Weight

Kg

596

601

671

672

672

Gross Weight

Kg

677

677

752

753

753

dB(A)

58/60

58/60

58/60

58/60

58/60

dB(A)

58/60

60/62

58/60

58/60

58/60

°C

10~45

10~45

10~45

10~45

10~45

°C

10~45

10~45

10~45

10~45

10~45

L/min

404.3

423.3

442.7

456.0

482.7

L/min

501.7

525.0

540.0

553.3

580.0

kPa

/

/

/

/

/

kPa

/

/

/

/

/

kgf/cm2

20

20

20

20

20

kgf/cm2

20

20

20

20

20

Liquid Pipe

mm

Ø19.05

Ø19.05

Ø19.05

Ø19.05

Ø19.05

Liquid Pipe

mm

Ø19.05

Ø19.05

Ø22.2

Ø22.2

Ø22.2

Low Pressure Gas Pipe

mm

Ø38.1

Ø38.1

Ø38.1

Ø38.1

Ø38.1

Low Pressure Gas Pipe

mm

Ø38.1

Ø38.1

Ø38.1

Ø38.1

Ø38.1

High/Low Pressure Gas Pipe

mm

Ø31.75

Ø31.75

Ø31.75

Ø31.75

Ø31.75

High/Low Pressure Gas Pipe

mm

Ø31.75

Ø31.75

Ø38.1

Ø38.1

Ø38.1

DN32

DN32

DN32

DN32

DN32

DN32

DN32

DN32

DN32

DN32

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

G1-1/4B

40

40

40

40

40

40

Sound Pressure Level *2

Cooling/Heating Water Temperature*3

Water-Side Heat Exchanger

Water Flow Rate Water Pressure Drop Maximum Pressure Resistance

Refrigerant Connecting Pipes

Water Connecting Pipes MAX. Connectable Indoor Units MAX. Piping Length*4

Water Pipe Thread of Connector Drain Pipe

mm 40

Recommended MAX. m

40

Outer Diameter 18 40

64

64

64

64

64

300(500)

300(500)

300(500)

300(500)

300(500)

NOTES: *1. Operation Condition: Cooling:Indoor Temperature 27oCDB/19oC WB, Water Inlet/Outlet 30/35oC. Heating:Indoor Temperature 20oC DB/15oC WB, Water Inlet 20oC. *2. The sound pressure is based on the following conditions. 1 Meter from the unit service cover surface, and 1.5 Meters from floor level. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. *3. When unit is operating out of the allowable water temperature range, it won't strat normally and will alarm. *4. For Max.pipe length more than 300m, please contact our professional engineer.

Sound Pressure Level *2

Cooling/Heating Water Temperature*3

Water-Side Heat Exchanger

Water Flow Rate Water Pressure Drop Maximum Pressure Resistance

Refrigerant Connecting Pipes

Water Connecting Pipes MAX. Connectable Indoor Units MAX. Piping Length*4

Water Pipe Thread of Connector Drain Pipe

mm

Recommended MAX. m

Outer Diameter 18 40

738

64

64

64

64

64

300(500)

300(500)

300(500)

300(500)

300(500)

83/84

OUTDOOR UNIT

Hi-Smart

H Series

Product Line

Wide Operation Range The highest operation temperature reaches to 46oC* in cooling mode, and lowest operation temperature reaches to -20oC* in heating mode.

DC inverter-driven compressor Low noise technologies Compact and lightweight design Unique electrical system insect-resistant design Optimized air duct system design

Note:The double fan achieves the lowest operation temperature that can reach to -20oC in heating mode.

Electrical System Insect-resistant Design Aviation Level Design of Grilling Hi-Smart H Series creates a high-quality quiet environment. The design of the grilling follows the design concept of the aircraft engine design, which conforms to the aerodynamics principle. The noise has been greatly reduced. The grilling also increases safety as being a preventative for child figure being injured by the fan blade.

Electrical system adds insect-resistant design that effectively prevents insect from damaging the electrical system and improves the electrical system.

Optimized Air Duct System Design Optimized air duct system design improves air supply distance and avoids short circuit of return air and improves heat exchange ability. Similarly, the wind speed of 0.8m/s is taken as the critical judgment point. According to the measured results, the air supply distance of the grille before changing is 3.7m.The modified air supply distance is 4.6m and the air supply distance is increased by about 24%.

85/86

OUTDOOR UNIT

Product Line

AHU-CONNECTION KIT

Outdoor Unit Specifications

The Air-handing units connect to the Hisense VRF system through the AHU-KIT, which can provide more flexible air conditioning solutions and save more cost.

Main Function ON/OFF Control Capacity Demand

Temperature Setting Operation Mode Model(HP)

3

Model

AVW-28HJFH

Power Supply

AVW-34HJFH

AVW-43HJFH

AVW-43HKFH

42.7

42.7

kW

8.0

10.0

12.5

12.5

kW

1.93

2.34

2.98

3.81

4.15

4.27

4.19

3.28

kBtu/h

32.4

38.2

47.8

47.8

kW

9.5

11.2

14.0

14.0

kW

2.37

3.01

4.15

3.68

4.01

3.72

3.37

3.80

m³/min

46.5

69.0

78.0

75.0

Out Dimension(H×W×D)

mm

800×950×370

800×950×370

800×950×370

800×950×370

Packing Dimension(H×W×D)

mm

930×1025×460

930×1025×460

930×1025×460

930×1025×460

Net Weight

kg

65

73

78

84

Gross Weight

kg

72

81

86

96

Liquid Line

mm(in.)

Φ9.53(3/8)

Φ9.53(3/8)

Φ9.53(3/8)

Φ9.53(3/8)

Gas Line

mm(in.)

Φ15.88(5/8)

Φ15.88(5/8)

Φ15.88(5/8)

Φ15.88(5/8)

5

6

8

8

50/52

53/55

54/57

55/57

Heating Operation

Power Consumption

Nominal Capacity Power Consumption COP

Air Flow Rate

Refrigerant Piping

Max. number of connectable IDU Sound Pressure Level (Cooling/Heating) Operation Range

dB(A)

Cooling

o

Heating

o

C DB

C WB

-5~46

Wired Controller

Wired Controller

Sensor Signal Communication Wire

Compressor Type

-15~15.5

-15~15.5 HFQ-052F

Branch pipe Refrigerant Pipe

AC 380~415V 3Φ 50/60Hz

AC 220~240V 1Φ 50/60Hz 34.1

Nominal Capacity

EER

AHU

5

27.3

Control Box

Expansion Valve Box

5

kBtu/h

Cooling Operation

Wired Controller

-

4

Rotary

Notes: *1.The nominal cooling capacity and hesting capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature:20oC DB(68°F DB) Indoor Air Inlet Temperature:27.0oC DB(80°F DB) 19.0oC DB(66.2°F DB) Outdoor Air Inlet Temperature:7oC DB(45°F DB) 6oC DB(43°F DB) Piping Length:7.5Meters Piping Lift:0Meters *2.The sounf pressure level is based on following conditions: 1.5m beneath the unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

Scroll

87/88

OUTDOOR UNIT

Product Line

Outdoor Unit Specifications

Model(HP) Model

Nominal Capacity

6

5

6

AVW-38HJFH

AVW-48HJFH

AVW-54HJFH

AVW-48HKFH

AVW-54HKFH

38.2

47.8

52.9

47.8

52.9

kW

11.2

14.0

15.5

14.0

15.5

Power Consumption

Nominal Capacity

AC 380~415V 3Φ 50/60Hz

AC 220~240V 1Φ 50/60Hz

kBtu/h

kW

Model(HP) Model Power Supply

Cooling Operation

Nominal Capacity

4.21

3.92

4.44

4.31

4.05

3.68

3.57

3.49

EER

kBtu/h

42.7

54.6

61.4

54.6

61.4

kW

12.5

16.0

18.0

16.0

18.0

Nominal Capacity

Power Consumption

10

12

8

10

12

AVW-76HKFH

AVW-96HKFH

AVW-114HKFH

AVW-76H9FH

AVW-96H9FH

AVW-114H9FH

AC 220V 3Φ 60Hz

AC 380~415V 3Φ 50/60Hz

kBtu/h

76.5

95.6

114.3

76.5

95.6

114.3

kW

22.4

28.0

33.5

22.4

28.0

33.5

kW

6.36

7.80

10.60

6.30

8.30

10.70

3.52

3.59

3.16

3.56

3.37

3.13

kBtu/h

85.3

107.5

128

85.3

107.5

128

kW

25.0

31.5

37.5

25.0

31.5

37.5

kW

5.81

7.00

10.11

5.9

7.8

9.9

4.30

4.50

3.71

4.24

4.04

3.79

m³/min

150.0

163.0

163.0

121

150

163

Power Consumption

3.46

Heating Operation

8

-

2.60

EER

Heating Operation

5

-

Power Supply

Cooling Operation

4

Power Consumption

2.78

3.71

4.47

4.03

4.74

4.50

4.31

4.03

3.97

3.80

m³/min

90.0

90.0

100.0

90.0

100.0

Out Dimension(H×W×D)

mm

1380×950×370

1380×950×370

1380×950×370

1380×950×370

1380×950×370

Out Dimension(H×W×D)

mm

1650×1100×390

1650×1100×390

1650×1100×390

1650×1100×390

1650×1100×390

1650×1100×390

Packing Dimension(H×W×D)

mm

1520×1025×460

1520×1025×460

1520×1025×460

1520×1025×460

1520×1025×460

Packing Dimension(H×W×D)

mm

1748×1151×500

1748×1151×500

1748×1151×500

1748×1151×500

1748×1151×500

1748×1151×500

Net Weight

kg

93

95

97

103

103

Net Weight

kg

160

170

170

168

168

171

Gross Weight

kg

111

111

111

118

118

Gross Weight

kg

179

194

194

179

179

182

Liquid Line

mm(in.)

Φ9.53(3/8)

Φ9.53(3/8)

Φ9.53(3/8)

Φ9.53(3/8)

Φ9.53(3/8)

Liquid Line

mm(in.)

Φ12.7(1/2)

Φ12.7(1/2)

Φ12.7(1/2)

Φ9.53(3/8)

Φ12.7(1/2)

Φ12.7(1/2)

Gas Line

mm(in.)

Φ15.88(5/8)

Φ15.88(5/8)

Φ15.88(5/8)

Φ15.88(5/8)

Φ15.88(5/8)

Gas Line

mm(in.)

Φ22.2(7/8)

Φ25.4(1/1)

Φ25.4(1/1)

Φ19.05(3/4)

Φ22.2(7/8)

Φ25.4(1/1)

9

11

11

11

11

15

17

19

10

10

10

58/60

59/61

59/61

53/55

56/58

56/61

kW

COP Air Flow Rate

Refrigerant Piping

Max. number of connectable IDU Sound Pressure Level (Cooling/Heating) Operation Range

Cooling Heating

dB(A) o

o

50/52

52/54

C DB

48/50

-5~46

C WB

Refrigerant Piping

Max. number of connectable IDU Sound Pressure Level (Cooling/Heating)

Branch pipe

HFQ-052F Rotary

50/52

Air Flow Rate

Operation Range

-20~15.5

Branch pipe Compressor Type

53/55

COP

Scroll

dB(A)

Cooling

o

Heating

o

C DB

-5~46

C WB

-20~15.5 HFQ-162F

Compressor Type

Scroll

Notes:

Notes:

*1.The nominal cooling capacity and hesting capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature:27.0oC DB(80°F DB) Indoor Air Inlet Temperature:20oC DB(68°F DB) 19.0oC DB(66.2°F DB) Outdoor Air Inlet Temperature:7oC DB(45°F DB) 6oC DB(43°F DB) Piping Length:7.5Meters Piping Lift:0Meters

*1.The nominal cooling capacity and hesting capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature:27.0oC DB(80°F DB) Indoor Air Inlet Temperature:20oC DB(68°F DB) 19.0oC DB(66.2°F DB) Outdoor Air Inlet Temperature:7oC DB(45°F DB) 6oC DB(43°F DB) Piping Length:7.5Meters Piping Lift:0Meters

*2.The sounf pressure level is based on following conditions: 1.5m beneath the unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

*2.The sounf pressure level is based on following conditions: 1.5m beneath the unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

89/90

AIR TO WATER HEAT PUMP

Product Line

Hi-AquaSmart Series

Less CO2 Emissions

High-efficiency Air to Water Heat Pump 3 in 1 Solution

Hisense air to water heat pump system absorbs the free energy from outside atmosphere, which only consume less electricity to generate more heat energy.Hi-AquaSmart Series have better performance, high efficiency, high energysaving, less CO2 emissions.This Series can be easy to install on new building or existing building. High efficient Hisense air to water heat pumps can obviously reduce the energy consumption of the building. In addition, it can work with a traditional heating source,such as oil or gas boiler.

Using a heat pump can significantly reduce CO2 emissions.

Lower CO2 emissions Because heat pumps collect free energy from the air, they produce much less CO2. 66% less than Electric Heating 50% less than Oil Heating 30% less than Gas Heating

Economical Average annual running cost

Compared to the other heating modes, such as electricity, gas, coal/oil, solar,and so on, the heat pump system is more efficient and the annual cost reduction is obvious.

Direct electric heating Fuel boiler Gas condensing boiler Hi-AquaSmart

7/9/12kW

14/16kW

High Efficient Water Pump (DC)

Enhanced Vapor Injection Hisense adopts vapor injection scroll compressor, which provides higher compression ratio, smoother oil supply and lower noise level.

Hi-aquasmart Series is equipped with a high efficient DC(inverter) water pump,which can minimize energy consumption during operating time. It has a better linear controllable for capacity output and wider adaptability for many application places compared with AC water pump.

COP up to 4.84 Hi-AquaSmart Series is efficient, all products' COP is highter than 4.1, successfully meeting customers' requirements.

6

Increasing the suction of compressor and enhancing the heating capacity

Brand A

Brand B

7kw

4.5

4.4

4.4

9kw

4.62

4.23

4.65

12kw

4.1

4.49

4.45

2

14kw

4.84

4.44

4.22

1

16kw

4.74

4.2

4.1

4 3

The vapor injection system and stepless inverter technique greatly improve the refrigerant cycle system. It effectively increases refrigerant flow through vapor injecting, thus substantially enhancing the heating capacity.

Cpacity

5

0

4.5

7KW

4.62

9KW

4.1

12KW

4.84

14KW

4.74

16KW

Hisense

* Peak value * at standard condition working at heating capacity at +7℃ ( heating water at 35℃)

91/92

AIR TO WATER HEAT PUMP

Product Line

Strong Heating Capacity Under Low Ambient Hi-AquaSmart 14kw outdoor unit can maintain the same nominal capacity even at -15°C without electrical booster heater,and 16kw outdoor unit also can maintain the same nominal capacity even at -10°C without electrical booster heater. So designer don't need to oversize the heat pump's capacity even at outdoor temperatures as low as -15°C.

Heating capacity(kW)

20 18 16 14

16 14

14

14

14

16

16

16

14

14

Specification for Outdoor unit

12

Outdoor unit

10

Indoor unit

8

AHW-070UCSDP

AHW-090UCSDP AHW-120UCSDP AHW-140UCSEP AHW-160UCSEP

AHM-070UXCSAPA3

AHM-160UXCSAPA3

6

Refrigerant

R410A

4

Power supply

AC1Φ,220~240V/50Hz

2 0

7℃

2℃

-7℃

-10℃

AHW-140UCSDP

-15℃

7℃

2℃

-7℃

-10℃

Assembly Various Heat Sources Hi-AquaSmart is allowed to combine with existing boiler or solar, so undoubtedly Hi-AquaSmart will be the best alternative to traditional boiler system in old building, and also as a hot water back-up solution to the existing boiler. In case that one heating unit was not working due to some unforeseen problem, this system can ensure heating system no stopping.

Double-rotor compressor

Compressor

-15℃

AHW-160UCSDP

Condition 1 Ta7/6°C LWC35°C (DT= 5°C) Condition 2 Ta7/6°C LWC45°C (DT= 5°C) Cooling Ta35°C LWE18°C (DT= 5°C) Dimensions Operation Ambient Range

Heating capacity COP Heating capacity

kW kW

COP Cooling capacity

kW

EER

Scroll compressor with Vapor-injected

7

9

12

14

16

4.50

4.62

4.10

4.84

4.74

6.2

8.1

10.8

12.5

14.8

3.87

3.97

3.53

3.70

3.95

6.5

8

10.5

12

13.5

3.00

2.90

2.80

2.77

2.53

H*W*D

mm

Heating

°C

-20~35

DHW

°C

cooling

°C

-20~43 10~43

800×950×370

1380x950x370

Heating Sound pressure

dB(A)

51

52

54

51

52

Cooling Sound pressure

dB(A)

50

51

53

50

51

Note:

The cooling and heating performance in agreement with EN14511. Heating condition: Outdoor Air Temperature 7 oC DB/6oC DB, Inlet/Outlet water temperation 30oC/35oC. Cooling condition: Outdoor Air Temperature 35oC, Inlet/Outlet water temperation 12oC/7oC. Piping length:7.5 meter; Piping lift:0 meter

Central Hot Water Tank Note: The water tank could be sourced locally, Please contact with technicians for specification required.

Specification for Indoor unit AHM070UXCSAPA3

Capacity Power supply

Underfloor heating Low temperature radiators Temperature Sensor

kW

Hot water capacity

kW

7

16

Power input

kW

0.245

0.245

S

Motorized 2 ways Valve

Regulator

Motorized 3 ways Valve

Water Pump

890×520×320

mm kg

Decantation tank Expansion tank

Hot water temperature

55

Water pump

58 plate heat exchanger

Heating

°C

15~55

15~55

DHW

°C

15~55

15~55

cooling

°C

5~25

5~25

dB(A)

33

33

gas

mm

9.53

9.53

liquid

mm

15.88

15.88

Sound pressure level Piping connections

16

7

Heat Exchanger

Domestic hot water Hi-aquasmart+solar/boiler(optional)

Security Thermostat

Electric Heater

H*W*D

Net Weight

Check Valve

AC1Φ,220~240V/50Hz

Heating capacity

Dimensions

Operation system

AHM160UXCSAPA3

type

DC

DC

brand

Grundfos

Grundfos

3

3

Booster heating

kw

93/94

AIR TO WATER HEAT PUMP

Product Line Radiant floor heating is the most comfortable, optimal heating system nowadays. Hisense Multifunction VRF radiant floor heating system utilizes Hisense’s leading multi-split technology and advanced air-source heat pump technology, which is outstanding in floor heating system with integration of high efficiency, comfort and environmental protection.

MULTI-FUNCTION Series

Dual Water Temperature Control Technology Home Central Air Conditioning ·Radiant Floor Heating·Domestic Hot Water 3 in 1 Hisense Multifunction VRF System is a multifunctional intelligent ecology home system with integration of home central air conditioning, radiant floor heating and domestic hot water. Utilizing high efficient DC inverter technology, air source heat pump technology and heat recovery technology, it builds a more intelligent and more comfortable modern home life.

High Efficiency

Wide Operation Range

Comfort and Health Hidden Beauty

Stable and Reliable

Fixed Water Temperature Control (Fix Control Mode): The supplied water temperature maintains constant during operation, Users can set supplied water temperature value within the range of 20~55oC.



Variable Temperature Control (OTC Control Mode): System automatically adjusts water temperature according to temperature compensation curve basing on outdoor temperature to achieve optimum indoor temperature and reduce system power consumption. The compensation curve can also be adjusted manually according to operation conditions to realize energy saving.

Fixed Temperature Control Mode

Setting Water Temp (oC)

44

Point A

+8oC

Point B

20

-8oC

Under OTC control, the user respectively sets outside air temperature value and target water temperature value of point A and B, the system will automatically generate OTC curve according to the setting, thereby to arrive at the target water temperature value for each ambient temperature, the benefit of this setting is energy saving, because we reduce the demand for heat as the rise of ambient temperature. After curve is generated, users can also adjust the water temperature by wired remote control with ±8oC.



Fixed Temperature Control Mode Central Air-conditioning

Indoor Unit

Ideal choice of high quality home life, perfect integration with top-grade interior decoration .

-20

+20

Outdoor Temp.(oC)

Safe and Reliable Floor heating pipes are laid under the floor with advantages such as good stability, less vulnerable to external damage and corrosion, and its lifespan is almost the same with the building. Compared with other heating equipment, the cost of repair and maintenance afterwards is greatly reduced. At the same time, gas leak, explosion or other accidents caused by gas or stove can be avoided.

Radiant Floor Heating Hydronic Module

Ideal heating in winter, preserve health and comfort, clean and quiet.

Three-way Valve

Operation protection of the water system

Water system safeguards Besides safety valve and exhaust valve, the water flow switch and low pressure switch have been added into system, which can effectively avoid water leakage, water depletion, electric heater dry burning and other accidents.

Starting water pump automatically to avoid water scale generation and ensure the operation of water pump, three-way valve or other waterways parts. Timing Operatifon

Antifreezing Protection of Water System Domestic Hot Water Provide required hot water for home life, with automatic sterilization function, convenient and healthy.

Hisense Multi-function Series Outdoor Unit

Water Replenishing Central Hot Water Tank

Note:The water tank could be sourced locally, Please contact with technicians for specification required.

Automatic antifreezing function can avoid pipe cracking, leakage and other accidents when equipment is not used in winter.

T3

T2

Under standby mode T1 Constantly test the water temperature of inlet and outlet pipes. When the temperature is below T2, the pump starts. When the temperature is below T1, the pump and electric heating start until the water temperature rises to T3.

Electric heating starts Pump starts Electric heating starts

Pump starts

Water Depletion

Dry Burning

Commissioning Protection of Floor Heating Floor heating pipes need to warm gradually at the beginning of operation, in order to prevent problems such as floor deformation or leakage caused by sudden heat. Commissioning protection can ensure safe run testing.

Water temperature curve under standby mode



Water Leakage

t

Outlet Water Temperature (℃)

Floor Heating Run Testing

Number of days

95/96

AIR TO WATER HEAT PUMP

Product Line

Hisense home central air conditioning has been widely recognized by the market and users owning to its intelligence, comfort, high-efficiency and energy saving. Requirements for high-quality decoration and more comfort in villa and luxury residence make Hisense home central air conditioning play a principal role in home daily life. Hisense, the mark of high-quality life!

Hisense Multifunction VRF hot water system enables constant healthy hot water supply around the clock

Multiple Hot Water Production Mode Heat Recovery Mode Cooling operation Waste heat recovery

Domestic hot water

Electric energy Compressor

Energy output: 3-5 times of Condenser energy input

Evaporator

Throttle

Energy input

Under cooling operation in summer, the heat discharged from outdoor unit can be recovered directly and used for heating domestic hot water, allowing you to enjoy free and convenient hot water supply. Power consumption analysis When heating water by heat recovery mode, indoor unit performs cooling operation, the heat discharged from indoor unit is recovered and used for heating domestic hot water. Producing domestic hot water does not consume additional power, thereby the produced domestic hot water can be regarded as being acquired free of charge.

Power consumption index

0%

Heat Pump Mode

Unique 2+1 dimensional temperature sensation Power consumption index

33%

Electric Heating Mode

Winter (floor heating is not in use)

Too hot

Too hot

Too cold

Too cold

So comfortable

Power consumption analysis When heating hot water by electric heating, heat required for producing one share of hot water need consume electricity equivalent to the same amount of heat in the case of 100% of efficiency conversion.

Time

Traditional temperature control

Hisense 2+1 temperature sensation

Comfortable air supply Power consumption index

100%

Hisense indoor unit can adopt multiple air supply modes such as ceiling-supply and ceiling-return, side-supply and back-return, side-supply and bottom-return etc. according to room structure, making the air flow distribution more excellent. The airflow can be distributed to every corner, more uniform temperature distribution and more comfort .

Home central air conditioning Person is in the back flow area of air conditioning

360-degree air supply design More uniform temperature in air conditioning area

Wide Operating Range



Transitional season (neither cooling nor heating)

Power consumption index So comfortable

Start

Multifunction VRF Hot Water Production Flow and Water Tank Temperature Range Summer (Cooling operation)

Three temperature sensors including particular one on indoor unit air outlet can intelligently sense the temperature change of each sensitive point indoors and outdoors, dynamically calculate and adjust real-time output of compressor system, and balance the energy exchange variation of each room. Soft air supply keeps tiny temperature fluctuations in an optimum condition and brings gentle refreshing and intimate warmth.

When the desired domestic hot water temp is higher than 55oC, use energy-efficient heat pump to heat water to 55oC, then use auxiliary electric heating to heat water to a high temperature up to at most 75oC. Electric heater

Outdoor unit can be easily installed in small space, one outdoor unit can simultaneously satisfy the need for cool and warmness of multiple rooms, extending indoor exquisiteness and beauty to outdoors at the meantime.

"Three-dimensional" Cozy and Warm Feeling

When the desired domestic hot water temp is below 55oC, hot water can be heated using air source heat pump, saving more than 60% of electricity than direct electric heating. Power consumption analysis When using heat pump to heat hot water, power consumption required for producing one share of hot water is only 33% of the heat required for heating hot water when COP=3.0.

Reservoir

Delicate and Convenient

The tank water can be heated up to 75℃ Indoor unit cooling waste heat recovery

Recover waste heat for heating hot water Water is heated to about 50

℃ 55℃ DB

Use heat pump to heat hot water, water is heated to about 50℃

Auxiliary electric heating is started, water is heated to 70℃ -75℃

Sterilization function setting

System can handle a wide range of outside air condition. The lowest temperature in winter is -20oC WB, which can meet the heating needs of cold regions.

Outlet water temperature

20℃ DB

46℃ DB

Cooling

Winter

(floor heating is in use) Note: The actual data are closely related to using environment and conditions, the above data are for reference only.

15.5℃ WB

Heating

Water tank temperature

-5℃ DB -20℃ WB System operating range

97/98

AIR TO WATER HEAT PUMP

Product Line Hydronic Module Model

AFM-54EX4SA

Power Supply

Outdoor Unit Parameters 14

16

Rated Power (1)

kW

2.51

3.21

3.77

Capacity (A 2°C/W 35°C)(2)

COP (A -7°C/W 35°C)(3)

Heating(A2A)

Outdoor Units

16

Electrical Heater Capacity

kW

3

Cabinet Color

Weight

890×520×320

Net Weight

kg

58

kg

4.36

4.24

11.2

12.8

Type

-

3.12

3.05

2.97

kW

8.6

10.8

12.3

-

2.2

2.14

2.09

A+

A+

127%,A+

Type Number

A+

A+

118%,A+

11.2

14

15.5

Rated Power (4)

kW

2.99

3.92

4.44

-

3.75

3.57

3.49

Rated Capacity (4)

kW

12.5

16

18

Rated Power (4)

kW

2.98

4.03

-

4.19

3.97

Steel mm

8.96

Water Pump

lvory White

Materialr

4.46

kW

Lift Input

Water Storage Capacity

74 Constant

kpa

60

W

151 Plate heat exchanger 1

L

2.91

Minimum Flow

L/min

18

Rated Flow

L/min

45.8

4.74

Maximum Flow

L/min

3.8

Insulation Material

Water Pipe

Foamed plastic

Outer Dimensions (Height × Width × Depth)

mm

Weight

Kg

102

103

104

Sound Pressure level (5)

dB(A)

50/53

51/54

53/55

Sound Power Level (5)

dB(A)

67

68

69

Power Supply

Ф,V,Hz

Inverter Type

-

DC Inverter

Material

Cabinet Color

-

ivory White

Interface Size

inch

G1-1/4”

Heat Exchanger

-

Multi-Pass Cross-Finned Tube

Compressor Type

-

Hermetic (Scroll)

Pipe Size

inch

G1-1/4”

Safety Valve Specification

bar

3

Compressor Output

kW

1380×950×370

2.2

2.5

-

Directly startup

Fan Type

-

Axial flow fan

Fan Startup Mode

51×2

51×2

90

100

°C

-23 ~ 15

Floor Heating Operation Range (Outdoor Air Inlet Temperature)

°C

-23 ~ 15

Domestic Hot Water Operation Range (Outdoor Air Inlet Temperature)

°C

-23 ~ 43

Liquid Line

mm

Ф9.53

High Pressure Gas Line

mm

Ф12.7

Gas Line

mm

Ф15.88

-

R410A

kg

3.6

-

Micro-Computer Control Expansion Valve

NOTES:

When the connectiong capacity rate or indoor unit and outdoor unit is 100%,the cooling capacity and heating capacity are based on the following conditions: 1. Heating(A2W) conditions: Water inlet/outlet temperature:30°C DB(86°F DB)/35°C DB(95°F DB), Outdoor air inlet temperature:7°C DB(45°F DB), 6°C WB(43°F WB) 2. Heating(A2W) conditions: Water inlet/outlet temperature:30°C DB(86°F DB)/35°C DB(95°F DB), Outdoor air inlet temperature:2°C DB(35.6°F DB) 3. Heating(A2W) conditions: Water inlet/outlet temperature:30°C DB(86°F DB)/35°C DB(95°F DB), Outdoor air inlet temperature:-7°C DB(19.4°F DB) 4. Cooling(A2A) conditions: Piping length: 7.5 meters Indoor ait inlet temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor air inlet temperature:35°C DB(95°F DB) Heating(A2A) conditions:Indoor air inlet temperature: 20°C DB(68°F DB), 15.0°C WB(59°F WB) Outdoot air inlet temperature: 7°C DB(45°F DB),6°C WB(43°F WB) 5. The sound pressure level is based on following conditions: 1Meter from the unit service cover surface, and1.5 Meters fron floor level, The above data was measure in an anechoic chamber so that reflected sound should be taken into consideration in the field 6.The final appearance of outdoor unit is subject to the actual product.

Refrigerant circulating System

Maximum Pressure

bar

3

The pre pressure

bar

1

Pore Size

mm

Gas Pipe Size Liquid Pipe Size

Sound Pressure Level

Directly startup

Heating Operation Range (Outdoor Air Inlet Temperature)

8

Total Water Storage

90

-5 ~ 43

Flow Control

2.8

51×2

°C

Refrigerant Charge

Water Circulating System

w

Cooling Operation Range (Outdoor Air Inlet Temperature)

Type

Expansion Tank

Water Filter

m3/min -

L

Volume

AC1Ф,1220-240~, 50Hz

Compressor Startup Mode

Fan Air Volume

Refrigerant

kW

-

Rated Capacity (4)

Fan Output

Installation Data

Rated Heating Capacity

kW

Heating (55°C)

COP (4)

_

Gross Weight

Heating (35°C)

EER (4)

kW

Dimensions (Height × Width×Depth)

AFW-54U4SC

11.2

Capacity(A -7°C/W 35°C)(3)

Cooling(A2A)

AFW-48U4SC

kW

COP (A 2°C/W 35°C)(2)

Energy Efficiency Grade

AFW-38U4SC

Rated Capacity (1) COP (1) Heating(A2W)

Rated Cooling Capacity

Shell

Model

AC1Ф, 220~240V/50HZ

Operation range

Temperature of Outdoor Air Temperature of Water Supply

1 Brass

L

-

mm

Ф12.7

mm

Ф9.53

dBA

32

°CDB

-23~43

°C

20~55

Central Hot Water Tank

Note:The water tank could be sourced locally, Please contact with technicians for specification required.

99/100

INDOOR UNIT

Product Line

Hisense Hi-FLEXi & Hi-Smart Series provide a wide selection of indoor units for indoor decoration and create a personalized living space. HP

0.6

kBtu/h

5

1-Way Cassette Type

Various Model Types Easily Match Different Wide capacity range of outdoor units enables free model combination according to the actual situation of building. There are 12 types of indoor units for selection. Customer can choose appropriate type and capacity of indoor units according to interior decoration and functions.

Flexible Ways of Air Supply and Air Return 2-Way Cassette Type

Different duct types can be chosen to mactch different construction structure and interior decoration, which meets various personalized requirement of customers.

4-Way Cassette Type

Mini 4-Way Cassette Type

Ceiling Ducted Type (High Static Pressure)

Ceiling Ducted Type (Low Static Pressure)

Ceiling Ducted Type (AC Low-height)

Ceiling Ducted Type (DC Low-height)

Ceiling Supply Ceiling Return

Side Supply Ceiling Return

Side Supply Side Return

Side Supply Ceiling Return without Air Return Duct

Note:Side Supply Bottom Return will increase the noise level by 5-10 dB. It is not recommend to use in the environment which has high level requirement of noise.

Precise Room Temperature Control Hisense sets temperature sensors on air outlet /air inlet of indoor units and remote controller, and adopts microcomputer control 2000-pulse high precision electronic expansion valve to adjust refrigerant flow rate, high precision electronic expansion valve to adjust refrigerant flow rate, which can maintain the room temperature within 0.5℃ of setting temperature and satisfy the indoor comfort requirement.

Top Class Low Noise Design In accordance with application situation and structure, Hisense has been studying the technical and installation methods for noise reduction of indoor units from various aspects of fan motor, fan blade and air duct layout, which provides customers with the quietest air conditioned environment.

Ceiling & Floor Type

Wall Mounted Type

Whisper

Operation

30dB(A) Noise LevelHave No Impact on Sleep

21dB(A)

30dB(A)

Quiet Library

Street

Floor Concealed Type

20dB(A) Console Type

Ceiling Ducted Type

40dB(A)

70dB(A)

101/102

INDOOR UNIT

Product Line

1-Way Cassette Type

2-Way Cassette Type

Fashionable Appearance, Convenient Installation

2-way Individual Louver The newly equipped individual louver setting function allows the angles of the 2 louvers to be adjusted individually.

Customers can choose the installation method according to different situation. The concise fashion elements style is suitable for renewal projects and undecorated shopping malls or classrooms.

Efficiency DC Motor, Adjustable Air Speed

Wider 3D-air Flow Range Broad air deflector design realized broad air supply range. The wind direction can be adjusted accordingto the need thus makes the customers feel more comfortable.

Indoor unit Model Power Supply

kW

Heating Operation

Noise Level

Outer Dimensions

The Design of Low Noise

The unit can introduce fresh air from the external environment. With the filter facility, the air quality is garunteed.

The adoption of the efficient DC motor and the optimized duct design assure the smooth air flow.

The high efficiency turbofan form the wind pressure by rotating. Larger fan blades and slower fan speed realize the low operating noise.

Standard Equipped Drain Pump

Super Compact Structure Design, Easy for Installation

Standard equipped drain pump with the maximum drainage height up to 1200mm.

AVY-07UXJSJA

AVY-09UXJSJA

AVY-12UXJSJA

2.2

2.8

3.6

AVY-18UXJSKA

AVY-24UXJSKA

5.6

7.1

kcal/h

1,900

2,400

3,100

3,400

4,800

6,100

Btu/h

7,500

9,600

12,300

13,600

19,100

24,200

kW

2.5

3.2

4.0

4.5

6.3

8

kcal/h

2,100

2,700

3,400

3,800

5,400

6,800

Btu/h

85,00

10,900

13,600

15,400

21,500

27,300

dB(A)

33/32/31/30/29/28

35/34/32/31/29/28

40/36/35/33/30/29

40/36/35/33/30/29

41/39/36/35/33/31

48/46/43/40/37/33

H

mm

192

192

192

192

192

192

mm

910

910

910

910

1,180

1,180

D

mm

470

470

470

470

470

470

kg

19

19

20

20

24

24

Air Flow Rate

m3/h

Motor Power

W

40

40

40

40

60

60

mm

Gas Line

mm

Ф6.35 Ф12.7

Ф6.35 Ф12.7

Ф6.35

Ф6.35

Ф12.7

Ф12.7

Ф6.35 Ф15.88

Ф9.53 Ф15.88

VP25 (Outer Diameter Ф32)

Condensate Drain Panel Model

Model Power Supply

HP-D-NA

HP-D-NA

HP-D-NA

Cabinet Color

HP-D-NA

HP-E-NA

HP-E-NA

2-Way Cassette Type

AC1Φ 220V~240V /50Hz/60Hz

AVL-07 AVL-09 UXJSGA UXJSGA

AVL-12 AVL-14 AVL-18 AVL-24 AVL-27 AVL-30 AVL-38 AVL-48 AVL-54 UXJSGA UXJSGA UXJSGA UXJSGA UXJSGA UXJSGA UXJSHA UXJSHA UXJSHA

kW

2.2

2.8

3.6

4.3

5.6

7.1

8.4

9.0

11.2

14.0

16.0

kcal/h

1,900

2,400

3,100

3,700

4,800

6,100

6,900

7,700

9,600

12,000

13,800

Btu/h

7,500

9,600

12,300

14,700

19,100

24,200

28,700

30,700

38,200

47,800

54,600

kW

2.8

3.3

4.0

4.9

6.5

8.0

9.0

10.0

13.0

16.0

18.0

Heating Operation

kcal/h

2,400

2,800

3,400

4,200

5,600

6,800

7,800

8,600

11,200

13,800

15,500

Btu/h

9,600

11,300

13,600

16,700

22,200

27,300

30,700

34,100

44,400

54,600

61,400

Noise Level

dB(A)

32/30/29/27

33/30/29/28

34/31/30/28

40/37/34/32

42/39/36/33

45/42/40/36

47/44/40/36

49/46/42/37

46/44/40/38

48/45/42/38

49/46/43/40

Cooling Operation

Outer Dimensions

H

mm

298

298

298

298

298

298

298

298

298

298

298

W

mm

860

860

860

860

860

860

860

860

1,420

1,420

1,420

D

mm

630

630

630

630

630

630

630

630

630

630

630

kg

22

22

22

24

24

24

24

24

39

39

600/510 /432/360

660/564 /492/396

720/630 /534/450

900/792 /690/594

1,020/894 /780/672

1,140/984 /858/738

1,260/1,104 /936/756

1,320/1,158 /978/786

1,800/1,584 /1,386/1,188

57

57

57

57

57

57

57

57

Net Weight

m3/h

Air Flow Rate

Flare-nut Connection (with Flare Nuts)

Liquid Line

Indoor unit

372/354/336/306/288/276 396/372/336/306/288/276 498/438/408/372/336/306 498/438/408/372/336/306 726/594/528/492/468/396 936/756/672/594/504/426

Refrigerant Piping Connection

Net Weight

4.0

The maximum drainage height up to 1200mm.

W

Net Weight

Panel Outer Dimensions

AVY-14UXJSJA

Fresh Air Introducing The unit can introduce fresh air from the external environment. With the filter facility, the air quality is ensured.

Standard Equipped Drain Pump

1-Way Cassette Type

AC1Φ 220V~240V /50Hz/60Hz

Cooling Operation

Efficiency DC Motor, Adjustable Air Speed

Fresh Air Introducing

Adoption of the efficient DC motor and the optimized duct design assure the smooth air flow.

Motor Power Refrigerant Piping Connection

57x2

mm

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Gas Line

mm

Ф12.7

Ф12.7

Ф12.7

Ф12.7

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

HP-C-NA

HP-C-NA

HP-C-NA

HP-C-NA

mm

55

55

55

55

55

55

Panel Model

W

mm

1,100

1,100

1,100

1,100

1,370

1,370

Cabinet Color

D

mm

550

550

550

550

550

550

kg

5

5

5

5

6

6

1. The nominal cooling capacity is based on following conditions: Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter 2. The sound pressure level is based on following condations: 1.0m beneath the unit,1.0m from Discharge Grille.The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. When bottom air inlet is adopted,sound pressure will increase according to factors such as installation mode and the room structure.

57x2

Liquid Line

H

NOTES:

2,220/1,950 /1,704/1,446

Flare-nut Connection(with Flare Nuts)

Condensate Drain

Neutral White

57x2

39

2,100/1,848 /1,614/1,266

Panel Outer Dimensions Net Weight

VP25(Outer Diameter Ф32) HP-C-NA

HP-C-NA

HP-C-NA

HP-C-NA

HP-F-NA

HP-F-NA

HP-F-NA

Neutral White H

mm

30

30

30

30

30

30

30

30

30

30

30

W

mm

1,100

1,100

1,100

1,100

1,100

1,100

1,100

1,100

1,660

1,660

1,660

D

mm

710

710

710

710

710

710

710

710

710

710

710

kg

7.5

7.5

7.5

7.5

7.5

7.5

7.5

7.5

10.5

10.5

10.5

NOTES: 1. The nominal cooling capacity is based on following conditions: Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) 2. The sound pressure level is based on following conditions: 1.5m beneath the unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

Piping Length: 7.5 Meters Piping Lift: 0 Meter

103/104

INDOOR UNIT

Product Line

Mini 4-Way Cassette Type

4-Way Cassette Type

Mini Design

Installation Direction Can be Changed Easily for Convenient Pipe Connection Squared design for unit body and installation bracket, unit body can be installed in any direction horizontally for convenient pipe connect position.

The unit thickness is merely 215mm leading in the industry and the ceiling height required for installation is only 245mm. It is extremely space saving. New appearance of the air return grille is honeycomb structure.

Installation bracket

840mm Drainage pipe

570mm

840mm

Connection pipe

Indoor unit

kW

AVBC-09 HJFKA

AVBC-12 HJFKA

AVBC-15 HJFKA

AVBC-19 HJFKA

AVBC-22 HJFKA

AVBC-24 HJFKA

AVBC-27 HJFKA

AVBC-30 HJFKA

AVBC-38 HJFKA

AVBC-48 HJFKA

AVBC-54 HJFKA

2.8

3.6

4.5

5.6

6.3

7.1

8.0

9.0

11.2

14.0

16.0

2,400

3,100

3,900

4,800

5,400

6,100

6,900

7,700

9,600

12,000

13,800

Btu/h

9,600

12,300

15,400

19,100

21,500

24,200

27,300

30,700

38,200

47,800

54,600

kW

3.2

4.0

5.0

6.3

7.1

8.0

9.0

10.0

12.5

16.0

18.0

kcal/h

2,500

3,400

4,300

5,400

6,100

5,900

7,700

8,600

10,800

13,800

15,500

Btu/h

9,900

13,600

17,100

21,500

24,200

27,300

30,700

34,100

42,700

54,600

61,400

dB(A)

30/28/28/27 /26/26

32/29/29/28 /27/26

33/31/29/29 /27/26

34/31/30/28 /28/26

36/33/32/31 /29/28

36/33/32/31 /29/28

37/36/35/33 /31/30

37/36/35/33 /31/30

42/40/38/36 /34/33

46/44/40/38 /36/34

46/44/41/40 /38/36

H

mm

238

238

238

238

238

238

288

288

288

288

288

W

mm

840

840

840

840

840

840

840

840

840

840

840

D

mm

840

840

840

840

840

840

840

840

840

840

840

kg

20

20

21

21

23

23

26

26

26

26

26

m3/h

876/804/720 /648/600/528

990/840/768 /708/648/546

W

60

60

kcal/h

Nominal Heating Capacity

Noise Level

Net Weight Air Flow Rate Motor Power

Standard equipped drain pump with the maximum drainage height up to 1200mm.

HYXE-J01H*,HYXE-VA01,HYXM-VB01*.

4-Way Cassette Type

AC1Ф, 220~240V/ 50Hz(60Hz)

Nominal Cooling Capacity

Standard Equipped Drain Pump

These functions can be achieved by the wired controllers:

Standard equipped drain pump with the maximum drainage height up to 1200mm.

HYXE-J01H*,HYXE-VA01,HYXM-VB01*.

This function can be achieved by the wired controllers: HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H

b.The 4 air louvers can be controlled independently and 4 air speed adjustment are available to meet various requirement.

Standard Equipped Drain Pump

These functions can be achieved by the wired controllers:

The indoor unit will automatically set through Motion Sensor.

a.The unit has the breeze mode that provides miniature draft through the holes at the four flat corners.

This function can be achieved by the wired controllers: HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H

b.The 4 air louvers can be controlled independently and 4 air speed adjustment are available to meet various requirement.

Motion Sensor (Optional)

User-friendly Air Supply Mode

The indoor unit will automatically set through Motion Sensor.

a.The unit has the breeze mode that provides miniature draft through the holes at the four flat corners.

Outer Dimensions

620mm

Motion Sensor (Optional)

User-friendly Air Supply Mode

Model Power Supply

620mm

215mm

1,212/960/894 1,320/1,050/954 1,530/1,200/1098 1,602/1,260/1,146 1,572/1,320/1,218 1,572/1,380/1,242 2,160/1,800/1,644 2,166/2,010/1,776 2,166/2,040/1,842 /816/762/672 /930/816/750 /1,020/906/780 /1,080/978/882 /1,122/1,008/924 /1,176/1,062/966 /1,488/1,344/1,176 /1,632/1,452/1,344 /1,734/1,536/1,428

60

60

Piping Connections

60

60

60

60

127

127

127

Mini 4-Way Cassette Type

AC1Ф, 220~240V/ 50Hz(60Hz)

AVC-05HJFA

AVC-07HJFA

AVC-09HJFA

AVC-12HJFA

AVC-15HJFA

AVC-17HJFA

kW

1.5

2.2

2.8

3.6

4.5

5.0

5.6

kcal/h

1,300

1,900

2,400

3,100

3,800

4,300

4,800

Btu/h

5,100

7,480

9,520

12,240

15,300

17,000

19,040

Nominal Heating Capacity

kW

2.0

2.5

3.3

4.2

5.0

5.6

6.3

kcal/h

1,700

2,100

2,800

3,600

4,300

4,800

5,400

Btu/h

6,800

8,500

11,220

14,280

17,000

19,040

21,420

Noise Level

dB(A)

30/29/28/26

30/29/28/26

32/30/28/26

34/32/29/26

38/36/31/28

42/39/36/31

45/42/38/34

Nominal Cooling Capacity

Outer Dimensions

Liquid Line

mm

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Gas Line

mm

Ф12.7

Ф12.7

Ф12.7

Ф12.7

Ф12.7

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

H

mm

215

215

215

215

215

215

215

mm

570

570

570

570

570

570

570

D

mm

570

570

570

570

570

570

570

kg

14.5

14.5

14.8

14.8

15.8

15.8

15.8

m3/h

430/390/370/335

430/390/370/335

470/430/390/350

490/430/390/350

560/524/424/400

660/570/524/424

750/650/560/480

W

57

57

57

57

57

57

57

Net Weight Air Flow Rate Motor Power

Flare-nut Connection(with Flare Nuts)

Liquid Line

mm

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Gas Line

mm

Ф12.7

Ф12.7

Ф12.7

Ф12.7

Ф12.7

Ф12.7

Ф12.7

Condensate Drain

VP25(Outer Diameter Ф32mm)

VP25(Outer Diameter Ф32mm)

Panel Model

HP-G-NK

Panel Model

HPE-D-NK

Cabinet Color

Neutral White

Cabinet Color

Neutral White

Panel Outer Dimensions

H

mm

47

47

47

47

47

47

47

47

47

47

47

W

mm

950

950

950

950

950

950

950

950

950

950

950

D

mm

950

950

950

950

950

950

950

950

950

950

950

Net Weight

kg

5.7

5.7

5.7

5.7

5.7

5.7

5.7

5.7

5.7

5.7

5.7

Packing Volume

m3

0.110

0.110

0.110

0.110

0.110

0.110

0.110

0.110

0.110

0.110

0.110

NOTES: 1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature:27°C DB(80°F DB),19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature:35°C DB(95°F DB) Piping Length:7.5 Meters Piping Lift:0 Meter Heating Operation Conditions Indoor Air Inlet Temperature:20°C DB(68°F DB) Outdoor Air Inlet Temperature:7°C DB(45°F DB),6°C WB(43°F WB)

AVC-19HJFA

W

Piping Connections

Flare-nut Connection(with Flare Nuts)

Condensate Drain

Indoor unit Model Power Supply

Panel Outer Dimensions

H

mm

37

37

37

37

37

37

37

W

mm

620

620

620

620

620

620

620

D

620

mm

620

620

620

620

620

620

Net Weight

kg

2.7

2.7

2.7

2.7

2.7

2.7

2.7

Packing Volume

m3

0.046

0.046

0.046

0.046

0.046

0.046

0.046

NOTES: 2. The sound pressure level is based on following conditions:1.5m beneath the unit. The above data was mesaured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature:2°C DB(80°F DB),19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature:35°C DB(95°F DB) Piping Length:7.5 Meters Piping Lift:0 Meter Heating Operation Conditions Indoor Air Inlet Temperature:20°C DB(68°F DB) Outdoor Air Inlet Temperature:7°C DB(45°F DB),6°C WB(43°F WB)

2. The sound pressure level is based on following conditions:1.5m beneath the unit. The above data was mesaured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

105/106

INDOOR UNIT

Product Line

Ceiling Ducted Type

Ceiling Ducted Type

(High Static Pressure)

(Low Static Pressure)

Installation Space-saving

Installation Space-saving

The height less than 270mm can be easily fit into the limited space in the false ceiling (7.5-24.2KBtu/h).

The height less than 270mm can be easily fit into the limited space in the false ceiling (7.5-24.2KBtu/h).

Minimum 5mm 270mm 7.5-24.2KBtu/h

False Ceiling

Fresh Indoor Air

The cooling and heating air distributed from the unit to the indoor space through ducts, which creates a comfortable environment.

Air Return

When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.

Fresh Indoor Air By introducing fresh outdoor air and being equipped with the air filter to keep indoor air clean.

Indoor Unit

Air Supply

Excellent Air Flow

Duct

False Ceiling

Satisfying Varied Requests on Installation

By introducing fresh outdoor air and being equipped with the air filter to keep indoor air clean.

Indoor Unit

NOTE:

270mm 7.5-24.2KBtu/h

Satisfying Varied Requests on Installation

Air Supply

Minimum 5mm

Excellent Air Flow The cooling and heating air distributed from the unit to the indoor space through ducts, which creates a comfortable environment.

Duct Air Return

NOTE:

When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.

Optional Parts

Optional Parts

The drain pump can be supplied as optional part. Indoor unit Model Power Supply

kW

Nominal Heating Capacity Noise Level (H/M/L) Outer Dimensions

Indoor unit

Ceiling Ducted type (High Static Pressure)

AC1Ф, 220 ~240V/50Hz AC1Ф, 220V/60Hz

Nominal Cooling Capacity

The drain pump can be supplied as optional part.

AVD-07 UXCSAH AVD-07 UX2SAH

AVD-09 UXCSAH AVD-09 UX2SAH

2.2

2.8

AVD-12 AVD-14 AVD-17 UXCSAH UXCSAH UXCSBH AVD-12 AVD-14 AVD-17 UX2SAH UX2SAH UX2SBH 3.6

4.3

5.0

AVD-18 AVD-22 UXCSBH UXCSBH AVD-18 AVD-22 UX2SBH UX2SBH 5.6

6.3

AVD-24 AVD-27 AVD-30 AVD-38 AVD-48 UXCSBH UXCSCH UXCSCH UXCSCH UXCSDH AVD-24 AVD-27 AVD-30 AVD-38 AVD-48 UX2SBH UX2SCH UX2SCH UX2SCH UX2SDH 7.1

8.4

9.0

11.2

14.2

AVD-54 AVD-76 AVD-96 UXCSDH UX6SEH*1 UX6SFH*1 AVD-54 AVD-76 AVD-96 UX2SDH UX2SFH*2 UX2SFH*2 16.0

22.4

28.0

kcal/h

1,900

2,400

3,100

3,700

4,300

4,800

5,400

6,100

7,200

7,700

9,600

12,200

13,800

19,300

24,100

Btu/h

7,500

9,600

12,300

14,700

17,100

19,100

21,500

24,200

28,700

30,700

38,200

48,500

54,600

76,500

95,600

kW

2.8

3.3

4.2

4.9

5.6

6.5

7.5

8.5

9.6

10.0

13.0

16.3

18.0

25.0

31.5

kcal/h

2,400

2,800

3,600

4,200

4,800

5,600

6,500

7,300

8,300

8,600

11,200

14,000

15,500

21,500

Btu/h

9,600

11,300

14,300

16,700

19,100

22,200

25,600

29,000

32,800

34,100

44,400

55,600

61,400

85,300 107,500

dB(A) 33-31-29 33-31-29 33-31-29 33-31-29 34-32-30 34-32-30 36-34-32 36-34-32 41-39-34 41-39-34 43-40-36 44-41-36 43-40-37 H

mm

270

W

mm

650+75

D

mm

720

Net Weight

kg

Air Flow Rate (H/M/L)

m3/h

Motor Power

W

270

270

270

270

270

270

270

350

350

350

350

350

650+75 650+75 650+75 900+75 900+75 900+75 900+75 900+75 900+75 900+75 1300+75 1300+75 720

720

720

720

720

720

25 480/420 /360

25 480/420 /360

25 780/660 /540

25 780/660 /540

34 900/780 /660

34 900/780 /660

34 960/840 /720

110

110

150

150

150

150

150

Piping Connections

720

800

800

800

800

800

34 44 44 44 56 56 960/840 1600/1400 1600/1400 1600/1400 2100/1750 2150/1800 /720 /1150 /1150 /1150 /1450 /1550 190

300

300

300

430

430

Flare-nut Connection(with Flare Nuts)

52

27,100

54

470

470

1060

1250

1120

1120

94

106

3480

4650

1030

1280

Brazing

Liquid Line

mm

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Gas Line

mm

Ф12.7

Ф12.7

Ф12.7

Ф12.7

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф19.05

Ф22.2

VP25(Outer Diameter Ф32 )

Condensate Drain External Static Pressure

Pa

50(80)

50(80)

50(80)

50(80)

50(80)

50(80)

50(80)

50(80)

120(90)

120(90)

120(90)

120(90)

120(90)

220

220

Packing Volume

m3

0.21

0.21

0.21

0.21

0.27

0.27

0.27

0.27

0.38

0.38

0.38

0.52

0.52

0.90

1.06

Nominal Cooling Capacity

Nominal Heating Capacity Noise Level (H/M/L) Outer Dimensions

AVD-07 UXCSAL AVD-07 UX2SAL

AVD-09 UXCSAL AVD-09 UX2SAL

AVD-12 UXCSAL AVD-12 UX2SAL

AVD-14 AVD-17 UXCSAL UXCSBL AVD-14 AVD-17 UX2SAL UX2SBL

AVD-18 AVD-22 UXCSBL UXCSBL AVD-18 AVD-22 UX2SBL UX2SBL

AVD-24 AVD-27 AVD-30 UXCSBL UXCSCL UXCSCL AVD-24 AVD-27 AVD-30 UX2SBL UX2SCL UX2SCL

AVD-38 UXCSCL AVD-38 UX2SCL

AVD-48 UXCSDL AVD-48 UX2SDL

AVD-54 AVD-76 AVD-96 UXCSDL UX6SEL*1 UX6SFL*1 AVD-54 AVD-76 AVD-96 UX2SDL UX7SEL*2 UX7SFL*2

kW

2.2

2.8

3.6

4.3

5.0

5.6

6.3

7.1

8.4

9.0

11.2

14.2

16.0

22.4

28.0

kcal/h

1,900

2,400

3,100

3,700

4,300

4,800

5,400

6,100

7,200

7,700

9,600

12,200

13,800

19,300

24,100

Btu/h

7,500

9,600

12,300

14,700

17,100

19,100

21,500

24,200

28,700

30,700

38,200

48,500

54,600

76,500

95,600

kW

2.8

3.3

4.2

4.9

5.6

6.5

7.5

8.5

9.6

10.0

13.0

16.3

18.0

25.0

31.5

kcal/h

2,400

2,800

3,600

4,200

4,800

5,600

6,500

7,300

8,300

8,600

11,200

14,000

15,500

21,500

27,100

Btu/h

9,600

11,300

14,300

16,700

19,100

22,200

25,600

29,000

32,800

34,100

44,400

55,600

61,400

85,300 107,500

dB(A) 30-26-24 30-26-24 32-30-28 32-30-28 33-31-29 33-31-29 34-32-30 34-32-30 38-34-30 38-34-30 39-35-31 41-38-33 43-39-34 H

mm

270

270

W

mm

650+75

650+75

mm

720

720

720

720

720

720

720

25 480/420 /360

25 480/420 /360

25 780/660 /540

25 780/660 /540

34 900/780 /660

34 900/780 /660

34 960/840 /720

110

110

150

150

150

150

150

D Net Weight

kg

Air Flow Rate (H/M/L)

m3/h

Motor Power

W

270

270

270

650+75 650+75 900+75

Piping Connections

270 900+75

270

270

900+75 900+75

350

350

900+75 900+75

720

800

800

350

350

350

900+75 1300+75 1300+75 800

800

800

34 44 44 44 56 56 960/840 1550/1350 1550/1350 1550/1350 2150/1800 2200/1900 /720 /1150 /1150 /1150 /1500 /1500 190

300

300

300

430

430

Flare-nut Connection(with Flare Nuts)

50

52

470

470

1060

1250

1120

1120

94

106

3480

4320

950

1120

Brazing

Liquid Line

mm

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф6.35

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Gas Line

mm

Ф12.7

Ф12.7

Ф12.7

Ф12.7

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф15.88

Ф19.05

Ф22.2

VP25(Outer Diameter Ф32 )

Condensate Drain External Static Pressure Packing Volume

Pa m

3

30

30

30

30

30

30

30

30

60

60

60

60

60

100

100

0.21

0.21

0.21

0.21

0.27

0.27

0.27

0.27

0.38

0.38

0.38

0.52

0.52

0.90

1.06

NOTES:

NOTES: 1.The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20°C DB(68°F DB) Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB)

Model Power Supply

Ceiling Ducted type (Low Static Pressure)

AC1Ф, 220 ~240V/50Hz AC1Ф, 220V/60Hz

2. The sound pressure level is based on following conditions: 1.5m beneath the unit. With discharge duct (2.0m) and return duct(1.0m) The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3. When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure. *1: AC3Φ, 380V/50Hz, *2: AC3Φ, 380V/60Hz: AVD- 76UX7SEH; AVD-96UX7SFH

1.The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20°C DB(68°F DB) Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB)

2. The sound pressure level is based on following conditions: 1.5m beneath the unit. With discharge duct (2.0m) and return duct(1.0m) The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3. When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure. *1: AC3Φ, 380V/50Hz, *2: AC3Φ, 380V/60Hz

107/108

INDOOR UNIT

Product Line

Ceiling Ducted Type

Ceiling Ducted Type

(AC Low-height)

(DC Low-height)

Installation Space-saving

192mm

With the height is 192mm and the smallest depth is 447mm, it can make full use of the narrow space to realize various kinds of air flow.

192mm

Installation Space-saving

447mm 700mm

447mm 700mm

With the height is 192mm and the smallest depth is 447mm, it can make full use of the narrow space to realize various kinds of air flow.

192mm

192mm

Window Contact Design

Window Contact Design

The operation condition of the unit links with the window status through the window sensor and the Hisense indoor unit input function. This function saves energy and the automatic switch setting provides convenience for users.

The operation condition of the unit links with the window status through the window sensor and the Hisense indoor unit input function. This function saves energy and the automatic switch setting provides convenience for users.

The Unit Can Be Controlled Automatically Through The Hi Motion. This function can be achieved by the wired controller: HYXE-J01H*,HYXM-VB01*

Humidity Sensor Achieves The Automatic Dehumidification.

This function can be achieved by the wired controller: HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H

This function can be achieved by the wired controller: HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H

Standard Equipped Drain Pump

Broad air deflector design realized broad air supply range. The wind direction can be adjusted accordingto the need thus makes the customers feel more comfortable.

Standard equipped drain pump with the maximum drainage height up to 1200mm.

This function can be achieved by the wired controller: HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H

Indoor unit

Nominal Cooling Capacity

Nominal Heating Capacity Noise Level (Hi/Me/Lo) Outer Dimensions

Air Flow Rate (Hi/Me/Lo) Motor Power

AC 1Ф, 220~240V /50Hz

AVE-05HCFRL

AVE-07HCFRL

AVE-09HCFRL

AVE-12HCFRL

AVE-15HCFRL

AVE-17HCFRL

AVE-19HCFRL

AVE-22HCFRL

AVE-24HCFRL

kW

1.7

2.2

2.8

3.6

4.5

5.0

5.6

6.3

7.1

kcal/h

1,500

1,900

2,400

3,100

3,900

4,300

4,800

5,400

6,100

Gas Line

Standard equipped drain pump with the maximum drainage height up to 1200mm.

This function can be achieved by the wired controller: HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H

24,200

Celing Ducted Type (DC Low-height) DC 1Ф,220~240V /50Hz(60Hz)

Model Power supply

Nominal Cooling Capacity

AVE-05HJFDL

AVE-07HJFDL

AVE-09HJFDL

AVE-12HJFDL

AVE-15HJFDL

AVE-17HJFDL

AVE-19HJFDL

AVE-22HJFDL

AVE-24HJFDL

kW

1.7

2.2

2.8

3.6

4.5

5.0

5.6

6.3

7.1

kcal/h

1,500

1,900

2,400

3,100

3,900

4,300

4,800

5,400

6,100 24,200

5,800

7,500

9,600

12,300

15,300

17,100

19,100

21,500

kW

1.9

2.5

3.2

4.0

5.0

5.6

6.3

7.1

8.0

Btu/h

5,800

7,500

9,600

12,300

15,300

17,100

19,100

21,500

kcal/h

1,700

2,100

2,700

3,450

4,300

4,800

5,400

6,100

6,800

kW

1.9

2.5

3.2

4.0

5.0

5.6

6.3

7.1

8.0

Btu/h

6,500

8,500

11,300

13,600

17,100

19,100

21,500

24,200

27,300

kcal/h

1,700

2,100

2,700

3,450

4,300

4,800

5,400

6,100

6,800

Sound PressuredB(A)

29/24/22

29/24/22

35/25/23

35/25/23

36/25/23

36/25/23

35/25/23

39/26/25

39/26/25

6,500

8,500

11,300

13,600

17,100

19,100

21,500

24,200

27,300

H

mm

192

192

192

192

192

192

192

192

192

mm

700

700

700

700

910

910

1,180

1,180

1,180

mm

447

447

447

447

447

447

447

447

447

kg

16

16

17

17

21

21

25

26

26

m /h 3

W

420/330/282 14

420/330/282 14

540/342/288 29

Piping Connections Liquid Line

Standard Equipped Drain Pump

Broad air deflector design realized broad air supply range. The wind direction can be adjusted accordingto the need thus makes the customers feel more comfortable.

Btu/h

W D

Net Weight

Wider 3D-air Flow Range

This function can be achieved by the wired controller: HYXE-VA01,HYXM-VB01,HYXE-J01H

Indoor unit

Celing Ducted Type (AC Low-height)

Model Power supply

This function can be achieved by the wired controller: HYXE-J01H*,HYXM-VB01*

Humidity Sensor Achieves The Automatic Dehumidification.

Wider 3D-air Flow Range

This function can be achieved by the wired controller: HYXE-VA01,HYXM-VB01,HYXE-J01H

The Unit Can Be Controlled Automatically Through The Hi Motion.

540/342/288

720/378/330

720/378/330

35

29

35

810/480/462

1,080/558/522

1,080/558/522

40

60

60

Φ6.35

Φ9.53

Φ9.53

Flare-nut Connection(with Flare Nuts) mm mm

Φ6.35 Φ12.7

Φ6.35 Φ12.7

Φ6.35 Φ12.7

Φ6.35 Φ12.7

Condensate Drain

Φ6.35 Φ12.7

Φ6.35 Φ12.7

Φ15.88

Φ15.88

Φ15.88

VP25(Outer Diameter Ø32mm)

External Pressure

Pa

Approximate Packing Measurement

m3

10(30) 0.15

0.15

0.15

0.15

0.18

0.18

0.22

0.22

0.22

NOTES: 1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature:27oC DB(80oF DB),19.0oC WB(66.2oF WB) Outdoor Air Inlet Temperature:35oC DB(95oF DB) Piping Length:7.5 Meters Piping Lift:0 Meter Heating Operation Conditions Indoor Air Inlet Temperature:20oC DB(68oF DB) Outdoor Air Inlet Temperature:7oC DB(45oF DB),6oC WB(43oF WB)

2. The sound pressure level is based on following conditions:1.5m beneath the unit. The above data was mesaured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

Nominal Heating Capacity

Btu/h Sound PressuredB(A)

Noise Level

28/27/26/24/23/21 28/27/26/24/23/21 35/32/32/30/26/23 35/32/32/30/26/23 35/32/32/30/26/23 35/32/32/30/26/23 35/32/30/28/25/23 38/36/35/33/31/24 38/36/35/33/31/24

H

mm

192

192

192

192

192

192

192

192

192

W

mm

700

700

700

700

910

910

1180

1,180

1,180

D

mm

447

447

447

447

447

447

447

447

447

kg

16

16

17

17

20

20

24

24

24

Air Flow Rate

m3 /h

420/390/366/ 342/318/288

420/390/366/ 342/318/288

540/486/438/ 402/354/312

540/486/438/ 402/354/312

720/648/564/ 486/408/330

720/648/564/ 486/408/330

810/750/672/ 600/528/462

1,080/966/858/ 738/630/522

1,080/966/858/ 738/630/522

Motor Power

W

40

40

40

40

40

40

60

60

60

Outer Dimensions

Net Weight

Piping Connections

Flare-nut Connection(with Flare Nuts)

Liquid Line

mm

Φ6.35

Φ6.35

Φ6.35

Φ6.35

Φ6.35

Φ6.35

Φ6.35

Φ9.53

Φ9.53

Gas Line

mm

Φ12.7

Φ12.7

Φ12.7

Φ12.7

Φ12.7

Φ12.7

Φ15.88

Φ15.88

Φ15.88

0.18

0.22

0.22

0.22

Condensate Drain

VP25(Outer Diameter Ø32mm)

External Pressure

Pa

Approximate Packing Measurement

m3

10(0-10-30) 0.15

0.15

0.15

0.15

0.18

NOTES: 1. The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature:27oC DB(80oF DB),19.0oC WB(66.2oF WB) Outdoor Air Inlet Temperature:35oC DB(95oF DB) Piping Length:7.5 Meters Piping Lift:0 Meter Heating Operation Conditions Indoor Air Inlet Temperature:20oC DB(68oF DB) Outdoor Air Inlet Temperature:7oC DB(45oF DB),6oC WB(43oF WB)

2. The sound pressure level is based on following conditions:1.5m beneath the unit. The above data was mesaured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

109/110

INDOOR UNIT

Product Line

Ceiling & Floor Type

Wall Mounted Type

Flexible Installation

The Design of Elegant Smooth Panel with Hidden LED Display

The unit can be installed either standing on the floor or hanging under the ceiling.

The quality of “Elegance” is to meet contemporary needs. The simple and smooth form harmonizes with any interior style. The smooth panel can be cleaned easily.

Convenient Installation and Maintenance Advanced structure design that makes the unit installatioin, pipe connection, even wiring work into simple.

Compact and Light Weight, Allowing Easy Installation

under the ceiling Side panel

on the floor

*The wireless remote controller HYE-W01 is standard for Ceiling & Floor Type.

Gas Line

New Fashion Design Appearance and High Quality

2. After open side panel, big space for pipe connection provide convenience for pipe installation

kW

AVV-22URSCA

AVV-24URSCA

AVV-27URSCB

AVV-30URSCB

AVV-38URSCB

AVV-48URSCC

AVV-17UR2SA

AVV-18UR2SA

AVV-22UR2SA

AVV-24UR2SA

AVV-27UR2SB

AVV-30UR2SB

AVV-38UR2SB

AVV-48UR2SC

5

5.6

6.3

7.1

8.4

9

11.2

14.2

4,300

4,800

5,400

6,100

7,200

7,700

9,600

12,200

Btu/h

17,100

19,100

21,500

24,200

28,700

30,700

38,200

48,500

kW

5.6

6.5

7.5

8.5

9.6

10

13

16.3

kcal/h

4,800

5,600

6,500

7,300

8,300

8,600

11,200

14,000

Btu/h

19,100

22,200

25,600

29,000

32,800

34,100

44,400

55,600

Motor Power

W

40

40

70

70

70

80

130

160

Air Flow Rate (H/M/L)

m3/h

780/660/540

780/660/540

966/840/678

966/840/678

1,092/912/732

1,164/978/798

Noise Level (Ceiling)

dB(A)

39/35/30

39/35/30

45/41/37

45/41/37

43/39/34

45/40/36

51/46/40

50/46/42

Noise Level (Floor)

dB(A)

43/38/35

43/38/35

48/44/40

48/44/40

46/41/37

48/43/39

54/49/43

55/50/46

1,488/1,230/978 1,980/1,680/1,380

H

mm

230

230

230

230

230

230

230

230

W

mm

990

990

990

990

1,285

1,285

1,285

1,580

D

mm

680

680

680

680

680

680

680

680

kg

31

31

32

32

39

40

41

47

Net Weight Piping Connections

Flare-nut Connection(with Flare Nuts)

Liquid Line

mm

Gas Line

mm

Φ6.35 Φ15.88

Φ6.35 Φ15.88

Φ9.53

Φ9.53

Φ9.53

Φ15.88

Φ15.88

Φ15.88

Condensate Drain Speed-up Setting HH1 Speed-up Setting HH2

Free Installation

Indoor unit

AVV-18URSCA

kcal/h

Outer Dimensions

Model Power Supply

Φ9.53

Φ9.53

Φ9.53

Φ15.88

Φ15.88

Φ15.88

m3/h

852

852

1,068

1,068

1,188

1,272

1,620

2,160

m3/h

960

960

1,200

1,200

1,338

1,410

1,752

2,244

NOTES: 2. The sound pressure level is based on following condations: 1.0m beneath the unit,1.0m from Discharge Grille. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. When bottom air inlet is adopted,sound pressure will increase according to factors such as installation mode and the room structure.

Quiet Operation for Super Low Sound Level The one-touch quiet operation can set the system work in a super low speed and make the noise level low to 28 dB(A).

Wall Mounted Type

AC1Φ220V ~240V/50Hz AC1Φ220V/ 60Hz

AVS-07URCSABA

AVS-09URCSABA

AVS-12URCSABA

AVS-14URCSABA

AVS-17URCSABA

AVS-18URCSBBA

AVS-22URCSBBA

AVS-24URCSBBA

AVS-09UR2SABA 2.8 2,400 9,500 3.3 2,800 11,100

AVS-12UR2SABA

AVS-14UR2SABA

AVS-17UR2SABA

AVS-18UR2SBBA

AVS-22UR2SBBA

AVS-24UR2SBBA

kW kcalh Btu/h kW kcalh Btu/h

AVS-07UR2SABA 2.2 1,900 7,500 2.5 2,150 8,500

4.0 3,450 13,600 4.5 3,900 15,300 830/660/520/460

5.0 4,300 17,000 5.6 4,800 19,100 900/750/590/460

5.6 4,816 19,100 6.3 5,418 21,500 893/782/671/582

m3/h

660/590/520/460

660/590/520/460

3.6 3,100 12,300 4.0 3,450 13,600 830/660/520/460

dB(A)

39/34/32/28

39/34/32/28

43/39/32/28

43/39/32/28

45/40/34/29

41/37/34/30

44/41/36/31

46/43/38/33

Net Weight

kg

13.5

13.5

13.5

13.5

13.5

16.0

16.0

16.0

Motor Power

W

50

50

60

60

65

62

72

82

Nominal Cooling Capacity Nominal Heating Capacity Air Flow Rate (High/Medium/Low/Mute) Noise Level (High/Medium/Low/Mute)

Connections Refrigerant Piping

6.3 7.1 5,418 6,106 21,500 24,200 7.1 8 6,106 6,880 24,200 27,300 1,006/893/716/621 1,122/984/804/649

Flare-nut Connection(with Flare Nuts)

Liquid Line

mm

Φ6.35

Φ6.35

Φ6.35

Φ6.35

Φ6.35

Φ9.53

Φ9.53

Φ9.53

Gas Line

mm

Φ12.7

Φ12.7

Φ12.7

Φ12.7

Φ12.7

Φ15.88

Φ15.88

Φ15.88

315

315

315

315

315

315

315

315

Outer Dimensions W

mm mm

960

960

960

960

960

1,120

1,120

1,120

D

mm

230

230

230

230

230

230

230

230

m3

0.17

0.17

0.17

0.17

0.17

0.19

0.19

0.19

Option

Option

Option

Option

Option

Option

Option

Option

Fan motor

PG Fan motor

PG Fan motor

PG Fan motor

PG Fan motor

PG Fan motor

PG Fan motor

PG Fan motor

PG Fan motor

Drain Pump

NO

NO

NO

NO

NO

NO

NO

NO

Condensate Drain

VP16(Outer Diameter Φ32) H

Packing Volume

VP25(Outer Diameter Φ32)

1.The nominal cooling capacity and heating capacity are based on following condations: Cooling Operation Condations Indoor Air Inlet Temperature: 27°C DB(80°F DB)19°C WB(66.2°F DB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Piping Length: 5.0Meter Piping Lift: 0Meter Heating Operation Condations Indoor Air Inlet Temperature: 20°C DB(68°F DB) Outdoor Air Inlet Temperature:7°C DB(45°F DB)6°C DB(43°F DB)

The sleep mode can be kept for 8 hours. The setting temperature can be adjusted automatically for your comfort.

The water drain pipe can be set either on the left side or on the right side of the unit. The connection pipe can be set in left, right or back side of the unit.

Ceiling & Floor Type

AC1Φ 220V~240V AVV-17URSCA 50Hz/60Hz

Nominal Heating Capacity

Anti-mold filter is equipped as standard accessory.

Wider 3D-air Flow Range

Indoor unit

The Sleep Mode Offers Comfortable Temperature for People to Enjoy Good Sleep

Anti-mold Filter

terminal

3. Set DIP switch by opening electric box cover, simple and convenience.

Broad air deflector design realized broad air supply range. The wind direction can be adjusted according to the need thus makes the customers feel more comfortable.

The fashionable design and streamline appearance gives a perfect choice for users.The integrative side panel makes the whole unit more concordant.big air outlet with an integrative large louver realizes high air volume and low noise.

Nominal Cooling Capacity

*The wireless remote controller HYE-W01 is standard for Wall Mounted Type. Liquid Line

1. Unit installation work can be done directly just open the side panel

Model Power Supply

For easy installation, a slim design is adopted to this new model by using a high proportion of lightweight resin parts, which greatly reduced the weight of the unit.

Power supply

Wireless Remote Controller/Receiver Wired Remote Controller

HYE-L01+Receiver

NOTES: 1.The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20°C DB(68°F DB) Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB)

2. The sound pressure level is based on following conditions: 1.0m beneath the unit and 1.0m from inlet grille. Voltage of the power source for the indoor fan motor is 220V. In case of the power sourse of 240V, the sound pressure level increases by about 1~2dB. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

111/112

INDOOR UNIT

Product Line

Floor Concealed Type

Console Type New Appearance Design

Compact Design Fitting Into a Tiny Space

The unit adopts the fashionable appearance with suspension flat design and realizes digital display function.

The design places special emphasis on the compatibility with the interior design as well as space saving design, allowing it to fit perfectly into the space below a bay window. So compact that it fits into even a tiny space.

Perfectly Fit The Indoor Decoration

Two-level Static Pressure Available

No matter what kind of decoration style it is, Hisense floor concealed type can be able to match it.

High static pressure achieves long distance air exhaust. The air can be reach to every part of the room.

The Unit Can Be Controlled Automatically Through The Hi Motion (Optional).

Hidden Installation, Space Saving Hisense floor concealed type can be installed in the decoration space, which is covered by the decoration.

Indoor unit

Nominal Cooling Capacity

Nominal Heating Capacity

Noise Level (H/M/L)

AVH-09UXCSAA

AVH-14UXCSAA

AVH-18UXCSBA

AVH-24UXCSBA

AC1Ф, 220V/60Hz

AVH-09UX2SAA

AVH-14UX2SAA

AVH-18UX2SBA

AVH-24UX2SBA

kW

2.8

4.3

5.6

7.1 6,100

kcal/h

2,400

3,700

4,800

Btu/h

9,600

14,700

19,100

24,200

kW

3.3

4.9

6.5

8.5

kcal/h

2,800

4,200

5,600

7,300

11,300

dB(A)

34-31-27

Cabinet Color

Outer Dimensions Net Weight

Humidity Sensor Achieves The Automatic Dehumidification (Optional).

AC1Ф, 220~240V/50Hz

Btu/h

16,700

22,200

29,000

40-36-34

41-36-32

44-40-36

Silky White

H

mm

620

620

620

620

W

mm

948+139

948+139

1,218+139

1,218+139

D

mm

202

202

202

202

kg

18

22

26

27

510/450/380

620/540/480

890/740/630

980/830/710

W

50

80

90

120

Liquid Line

mm

Ф6.35

Ф6.35

Ф6.35

Ф9.53

Gas Line

mm

Ф12.7

Ф12.7

Ф15.88

Ф15.88

VP25

VP25

VP25

VP25

0.19

0.19

0.23

0.23

Motor Power Piping Connections

Flare-nut Connection(with Flare Nuts)

Condensate Drain Packing Volume

m3

*The wireless remote controller HYE-W01 is standard for Console Type.

This function can be achieved by the wired controller: HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H

Indoor unit

Console Type AC 1Φ, 220~240V/50Hz (60Hz)

Model Power Supply

Nominal Cooling Capacity

Nominal Heating Capacity Noise Level (HH2/HH1/Hi/Me/Lo/Slo)

m3/h

Air Flow Rate (H/M/L)

DC Fan motor realizes high efficiency with 6 air flow speed adjustments to provide more options for customers.

This function can be achieved by the wired controller: HYXE-J01H*,HYXM-VB01*

Floor Concealed Type

Model Power Supply

High Efficiency and More Options

Outer Dimensions

AVK-07HJFCAA

AVK-09HJFCAA

AVK-12HJFCAA

AVK-15HJFCAA

AVK-17HJFCAA

kW

1.5

2.2

2.8

3.6

4.5

5.0

kcal/h

1,300

1,900

2,400

3,100

3,800

4,300

Btu/h

5,100

7,500

9,600

12,300

15,300

17,000

kW

2.0

2.5

3.3

4.2

5.0

5.6

kcal/h

1,700

2,100

2,800

3,600

4,300

4,800

Btu/h

6,800

8,500

11,200

14,300

17,000

19,100

dB(A)

32/30/29/28/26/24

34/32/31/29/27/26

36/35/32/31/29/27

39/36/34/31/29/27

41/39/37/35/33/32

44/43/41/39/37/36

H

mm

630

630

630

630

630

630

W

mm

700

700

700

700

700

700

D

mm

225

225

225

225

225

225

kg

16.1

16.1

16.1

17.4

17.4

17.4

444/420/384 /360/336/318

480/444/420 /384/360/336

492/456/408 /372/342/318

540/510/468 /432/396/384

606/582/540 /510/474/438

12

14

18

23

Net Weight Air Flow Rate (HH2/HH1/Hi/Me/Lo/Slo) Motor Power

AVK-05HJFCAA

m 3 /h W

360/342/318 /306/282/270 10

11

Flare-nut Connection (with Flare Nuts)

Piping Connections Liquid Line

mm

Φ6.35

Φ6.35

Φ6.35

Φ6.35

Φ6.35

Φ6.35

Gas Line

mm

Φ12.7

Φ12.7

Φ12.7

Φ12.7

Φ12.7

Φ12.7

Condensate Drain

mm

0.18

0.18

Outer Diameter Φ18 Pure White

Cabinet Color Packing Volume

m3

0.18

0.18

0.18

0.18

NOTES: NOTES: 1.The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20°C DB(68°F DB) Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB)

2.The sound pressure level is based on following conditions: 1.5m meters from the unit and 1.5m meters from floor level. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

1.The nominal cooling capacity and heating capacity are based on following conditions: Cooling Operation Conditions Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0℃ WB(66.2°F WB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter Heating Operation Conditions Indoor Air Inlet Temperature: 20°C DB(68°F DB) Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB)

2.The sound pressure level is based on following conditions: It is measured in anechoic room. Operation noise differs with operation and ambientconditions. Location of Microphone:

Microphone 1m

1m

113/114

VENTILATION SOLUTION​ ​

Product Line

All Fresh Air Indoor Unit

All Fresh Air Indoor Unit

(For S/G+/X/R/H/W Series)

Create Comfortable and Healthy Indoor Environment

Flexible Line-up to Hi-FLEXi Series and Hi-Smart Series

Create a comfortable and healthy indoor environment by introducing fresh outdoor air. By heating or cooling fresh outdoor air to almost the same temperature as room temperature, fresh ambient air can be adapted and then introduced into indoor room. Besides, after filtered, fresh outdoor air in transition seasons can be drawn to indoor room directly with no need of heating or cooling operation, While fresh outdoor air is introduced, other indoor units don’t bear fresh air load.

Indoor unit

All fresh air indoor units are applicable to Hi-FLEXi S, G+,X,R,W and Hi-Smart H Series outdoor units. General indoor units and all fresh air indoor units can be used together in Hi-FLEXi S, G+,X,R,W and Hi-Smart H Series system.

Advanced Contol

Higher External Static Pressure

All Fresh Air Indoor Unit AC3Ф, 380~ 415V/50Hz AC3Ф, 380V/60Hz

Model Power Supply Combined Outdoor Unit Model

Cooling Capacity

Can be interfaced to central control system. Easy electrical wiring design and installation.

Better installation flexibility at site, longer duct can be connected.

AC1Ф, 220~ 240V/50Hz AC1Ф, 220 V/60Hz

Model Power Supply

AVA-48UXCSQH-108

AVA-76UXCSRH-168

AVA-96UXCSRH-210

AVA-30UX2SCH-70

AVA-48UX2SQH-108

AVA-76UX2SRH-168

AVA-96UX2SRH-210

Combined Outdoor Unit Model

Hi-FLEXi S/G+/X/R/W Series kW

Nominal Cooling Capacity

kcal/h

Hi-Smart H Series

9.0

14 .0

22.4

28.0

7,700

12,000

19,300

24,100

Btu/h

30,700

47,800

76,500

95,600

kW

8.6

13.7

21.9

24.5

Hi-Smart H Series

kW

33.5

45.0

56.0

56.0

kcal/h

28,800

38,700

48,200

48,200

Btu/h

114,300

153,600

191,100

191,100

26.8

36.0

44.8

44.8

31,000

38,500

38,500

Btu/h

91,500

122,900

152,900

152,900

W

740

1120

1330

1620

H

mm

486

635

735

735

W

mm

1,270

1,950

1,950

1,950

D

mm

1,069

805

805

805

dB(A)

56

61

64

66

Kg

97

196

222

222

Net Weight

AVA-30UXCSCH-70

Hi-FLEXi S/G+/X/R/W Series

AVA-190 UX6STH-600 AVA-190 UX7tSTH-600

23,100

Sound Pressure Level All Fresh Air Indoor Unit

AVA-190 UX6STH-500 AVA-190 UX7STH-500

kW

Motor Power

Outer Dimensions

AVA-154 UX6SSH-400 AVA-154 UX7SSH-400

kcal/h

Heating Capacity

Indoor unit

AVA-114 UX6SRH-300 AVA-114 UX7SRH-300

Refrigerant

R410A

Indoor Fan Air Flow Rate

3

m /h

3,000

4,000

5,000

6,000

External Static Pressure

Pa

220

300

320

300

Air Inlet Size

mm

1,100×415

1,522×522

1,522×622

1,522×622

Air Outlet Size

mm

1,106×338

850×272

850×272

850×272

Drain Pipe Size

VP25,Outer Diameter: Φ32mm

RC1(Internal Screw)

kcal/h

7,400

11,800

18,800

21,100

Refrigerant Liquid Line Size

Btu/h

mm

Ф12.7

Ф12.7

Ф15.88

Ф15.88

29,400

46,800

74,700

83,600

W

Refrigerant Gas Line Size

150

330

490

510

mm

Ф25.4

Ф25.4

Ф28.6

Ф28.6

H

mm

370

370

486

486

W

mm

920

1,320

1,270

1,270

D

mm

800

800

1,069

1,069

Noise Level

dB(A)

32

43

45

46

Net Weight

Kg

46

60

97

97

Nominal Heating Capacity

Motor Power Outer Dimensions

R410A(Nitrogen-charged for Corrosion-resistance)

Refrigerant m3/h

660

External Static Pressure

Pa

60(120)

200

220

220

Air Inlet Size

mm

833×306

1233×306

1,100×415

1,100×415

Air Outlet Size

mm

803×220

1203×220

1,106×338

1,106×338

Refrigerant Liquid Line

mm

Ф9.53

Ф9.53

Ф9.53

Ф9.53

Refrigerant Gas Line

mm

Ф15.88

Ф15.88

Ф19.05

Ф22.2

Air Flow Rate

Drain Pipe Size

Temperature Range of Fresh Air Drawn

1,080

1,680

2,100

VP25, Outer Diameter: Ф32mm

Cooling: 20°C~43°C, Heating: -7°C~15°C

Temperature Range of Fresh Air Drawn

Cooling: 20°C~43°C, Heating: -7°C~15°C

NOTES: 1.The nominal cooling capacity and heating capacity are based on following conditions Cooling operation conditions: 33°C DB, 28°C WB, piping length: 7.5m, piping lift: 0m Heating operation conditions: 0°C DB, -9°C WB, piping length: 7.5m, piping lift: 0m (Heating capacity is tested when defrosting is not available ) 2.The sound pressure level is based on following conditions: 1.5 Meter beneath the unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the filed. 3.An air filter with duct collection efficiency more than 50% needs to be attached to the duct system of the suction side at site. 4.When the resistance of the filed-supplied duct is small, it may cause abnormal stop, malfunction, spraying water, etc.Due to excessive air flow. And the duct, which is to be connected to this unit, shall be insulation for dew protection. 5.All fresh air indoor unit is for processing fresh air load and not for stabilizing the room temperature. For adjusting the air conditioning load of the room, the additional air conditioner is required. 6.This unit shall be connected to Hi-FLEXi S, G+,X,R,W and Hi-Smart H Series outdoor units. In case of connecting this unit with other indoor units in the same refrigerant cycle,calculate the capacity of this unit as 46.1KBtu/h(30.7KBtu/h), 71.7KBtu/h(47.8KBtu/h), 143.3KBtu/h(95.6KBtu/h). 7.When Hi-Flexi outdoor unit connected to only with all fresh air indoor unit, the configuration rate is 100% (Recommended ). 8.Under cooling mode,when outdoor temperature is lower than 20℃ ,the system will automatically shift to ventilation operation; Under heating mode, when outdoor temperature is higher than 15°C the system will automatically shift to ventilation operation; In case inlet temperature is below -7°C all fresh air unit will stop.

115/116

VENTILATION SOLUTION​ ​

Product Line

Energy Saving Analysis

Heat Recovery Ventilator

VS ordinary ventilation fan

Summer Energy Saving Analysis Total heat exchanger mode

Outdoor air

Air inlet

Total heat exchanger

Total heat exchanger

Outdoor discharge air 32.6°C

Build a More Comfortable, Healthy and Energy-saving Living Space, Hisense High-performance Heat Recovery Ventilator

Room temperature

27°C

Outdoor air 35°C

Recycling coldkW

Outdoor fresh air 29.4°C after heat exchange

Hisense heat recovery ventilator adopts efficient convective transfer material to effectively recycle the heat losses due to ventilation, reduces the fresh air load, achieves the purpose of energy saving and lower running cost of air conditioning unit, fresh air is supplied to indoors continuously which can make your room more comfortable and healthy.

Heat loadkW

In summer operation, when the cold energy of 27°C air discharged from indoor pass through the heat exchanger, the 35°C outdoor hot air is pre-cooled to 29. 4°C fresh air and supplied to indoors, as shown above, the air conditioner only needs to cool the air by 2.4°C to maintain a comfortable room temperature and fresh air. In this process, the discharge air pre-cools the fresh air by HRV, The temperature recovery efficiency in cooling is 70% max, and enthalpy exchange efficiency is 57% max.

Outdoor discharge air 9°C

Room temperature

Indoor dirty air

21°C

Outdoor air 5°C

Outdoor fresh air 17°C after heat exchange

Airflow System Air Exhaust Dirty air exhaust

Blowing-in clean air enter house

Air Inlet Outdoor fresh air inlet

2.8

2.8

28 59.1 89.4

kJ/kg(DA)

89.4 0

Discharge air

27

Enthalpy value

55.5

49.8

kJ/kg(DA)

VS ordinary ventilation fan Outdoor air Total heat exchanger Dry bulb temperature °C Wet bulb temperature °C Moisture content g/kg Relative humidity % Enthalpy value kJ/kg(DA) Recycling coldkW

Traditional ventilation fan

17

5

9.4 4.2

2

Dry bulb temperature °C Wet bulb temperature °C Relative humidity %

6

Enthalpy value

35.3 27.8 1.3

58.5

2

2

Fan motor

Fan motor

Blowing-in clean air enter house

kJ/kg(DA)

12.9

Discharge air

21

Wet bulb temperature °C Relative humidity % Enthalpy value

2 58.5

0

Dry bulb temperature °C Air conditioning

5

12.9

Indoor air

In winter operation, when the heat energy of 21°C air discharged from indoor pass through the heat exchanger, the 5°C outdoor cold air is pre-heated to 17°C fresh air and supplied to indoors, as shown above, when outdoor 5°C air and indoor 21°C air pass through the HRV, the fresh air supplied to indoors is about 17°C, the air conditioner only needs to heat the air by 4°C to maintain a comfortable room temperature and fresh air. The temperature recovery efficiency in heating is 75% max, and enthalpy exchange efficiency is 63% max.

Air Return Indoor dirty air exhaust

59.1

19.5

Clean air after heat exchanger

Fan motor

Enthalpy value

21.1

60.1 69.8 1.57

Wet bulb temperature °C Relative humidity %

Heat loadkW

Air Exhaust Dirty air exhaust

28

35

Air inlet

Heat exchanger core

Filter

23.3 15.7

Dry bulb temperature °C Air conditioning

Total heat exchanger

Fan Motor

Fan blades

35

Winter Energy Saving Analysis Total heat exchanger mode

Outdoor fresh air

29.4

Dry bulb temperature °C Wet bulb temperature °C Relative humidity %

Indoor air

Basic Structure and Operation Principle Dirty air exhausted

Dry bulb temperature °C Wet bulb temperature °C Moisture content g/kg Relative humidity % Enthalpy value kJ/kg(DA)

Traditional ventilation fan

13 39.2

kJ/kg(DA)

36.5

Very Low Noise

Fan motor

Air Inlet Outdoor fresh air inlet

HKF-15B2EC~HKF-100B2EC

HKF-150B2EE~HKL-500B2EE

Air Return Indoor dirty air exhaust

Through a low-noise fan motor, advanced internal silence insulation device and optimization of air passage, the units have low noise. The minimum operating noise is only 28dB (A), which will not affect the user's sleep and rest at all. Street

Quiet library

Bedroom The noise of 30dB will not affect sleep.

Hisense Total Heat Exchanger HKF-15B1(2)EC*

117/118

VENTILATION SOLUTION​ ​

Product Line HKF-15B2EC

With Flexible Control, It Has Access to Centralized Control of Hisense Air Conditioning System

Product Dimensions

Controller

Total Heat Exchanger

LCD Wired Remote Controller - Standard

Electric Control Box

Large LCD screen interface, elegant appearance Can display room temperature, fan speed and so on Air volume setting function, the user can choose high, medium and low fan speed Product dimension:86*86mm

HYXE-M01H

Centralized Control System

Air Exhaust-Dirty air exhausted

Air Return-- Indoor dirty air exhausted

Air Intake-Outdoor fresh air intake

Blowing-in-Clean air blown indoor

Model HKF-15B2EC*

Hisense centralized control type total heat exchanger products can be connected to the centralized control system of Hisense air conditioning*, achieve the linkage with air conditioning system and centralized control, so the operation is more convenient and more intelligent!

Fresh air

Technical Parameters Model

Air Volume m³/h

Enthalpy Efficiency Enthalpy Efficiency External Static (Summer) (Winter) Pressure Pa

High Middle Low

High Middle Low High Middle Low High Middle Low

HKF-15B2EC*

Computer centralized control

Dirty air

Power Supply 220-240V /50HZ

Input Current A

High Middle Low .

.

.

Noise Level

Input Power KW

High

Middle

Low

.

.

.

dB(A)

High Middle Low

Weight kg

*: 220V/60Hz HKF-15B2E2

Outdoor unit

Product Feature Adapter Indoor unit

Indoor unit

Total heat exchanger

Indoor unit

Total heat exchanger

Outdoor unit

Indoor unit

Compact Machine, Convenient Installation. The thickness of machine is not more than 270mm that can be easily installed in the narrow residential ceiling. The width of the machine whose volume is under 300 m³/h is less than 600mm, which is particularly suitable for very narrow spaces in the ceiling, and can save the space of installation and ceiling, it is more convenient for construction.

Adjustable Air Volume, Quiet Operation. The air volume can be adjusted at a range of high, medium, or low level, the lowest noise in low level is only 28 dB(A) (HKF-15B1(2)EC in low level ), which reaches the lowest level in the industry.

Low Level: Gentle and fine airflow, tenderly caring baby-like sleep.

Medium Level:

High level:

Nature warm and refreshing enjoyed during breathing

Experience the natural wind, enjoy aerobic exercise

119/120

VENTILATION SOLUTION​ ​

Product Line

HKF-25B2EC~HKF-100B2EC

HKF-250B2EE~HKF-300B2EE Product Dimensions

Product Dimensions

Electric Control Box

Electric Control Box

Air Return-Indoor dirty air exhausted

Air Exhaust-Dirty air exhausted

Air Intake-Outdoor fresh air intake

Blowing-in-Clean air blown indoor

Model HKF-25B2EC* HKF-35B2EC* HKF-50B2EC* HKF-65B2EC* HKF-80B2EC* HKF-100B2EC*

Blowing-in-Clean air blown indoor

Air Exhaust-Dirty air exhausted

Air Intake-Outdoor fresh air intake

Air Return-Indoor dirty air exhausted

Technical Parameters

Technical Parameters

* : AC3Ф220V/60Hz HKF-250B2E9 HKF-300B2E9 AC3Ф380V/60Hz HKF-250B2EF HKF-300B2EF

HKL-400B2EE~HKL-500B2EE *: AC1Ф220V/60Hz HKF-25B2E2~HKF-100B2E2

HKF-150B2EE~HKF-200B2EE

Product Dimensions

Product Dimensions Check hole

Electric Control Box

Electric Control Box

Air Exhaust-Dirty air exhausted

Air Intake-Outdoor fresh air intake

Blowing-in-Clean air blown indoor

Air Return-Indoor dirty air exhausted

Air Exhaust-Dirty air exhausted

Blowing-in-Clean air blown indoor

Air Intake-Outdoor fresh air intake

Air Return-Indoor dirty air exhausted

Technical Parameters

Technical Parameters

* : AC3Ф220V/60Hz HKF-150B2E9 HKF-200B2E9 AC3Ф380V/60Hz HKF-150B2EF HKF-200B2EF

* : AC3Ф220V/60Hz HKF-400B2E9 HKF-500B2E9 AC3Ф380V/60Hz HKF-400B2EF HKF-500B2EF

121/122

VENTILATION SOLUTION​ ​

Product Line

Selection and Limitation of Heat Exchanger of AHU

AHU Connection KIT

The Heat Exchanger of AHU(field-supplied)should be selected according to the following technical data and limitations. Lifetime of the outdoor unit,operation range or operation reliability may be influenced if these limitations are neglected. The Hisense AHU-KIT can integrate external heat exchangers of Air-handing units (AHU) into a Hisense VRF system to be used for air conditioning,which can provide more flexible air conditioning solutions and save more cost in the building air conditioning renovation.

Main Function ON/OFF Control

Temperature Setting

Capacity Demand

Operation Mode

Refrigerant pipe Sensor signal Communication wire

Control Box

HYXE-VA01

*Cooling and heating capacity data based on the following indoor and outdoor temperature conditions: Expansion Valve Box

AHU DB:dry bulb;WB: wet bulb Pipe Length:7.5m;pipe height:0m

Wired Controller

Wired Controller

123/124

Control System

Control System

Wired Controller

HYXE-J01H Features: 4 inch large LCD screen with a resolution of 320×185. Functions are displayed in iconic form, more intuitive.

Wired Controller Wireless Controller Receiver Kit for Wireless Control-optional Centralized Controller Building Management System

120mm×120mm

Operation navigation, more convenient. Various displaying settings: backlit control, contrast ratio setting, backlit displaying time setting, keytone setting, indicator light brightness setting, clock setting, language switch. Max.16 indoor units can be connected. It can be used in main-auxiliary control mode.

Main Functions Cooling/Heating/Dry/Fan/Auto

Temperature Setting

Timer

Error Code Display

Check

Air Filter Cleaning Reminding

Error History Display

Mode Lock

Address Setting

Fan speed/Swing Louver

Weekly Timer

Holiday Setting

Various Control Solutions

Weekly Timer Setting Five different schedule timers can be set for each day of the week. 8

Indoor Unit Address Change In the process of installation work, indoor unit address can be changed through wired controller HYXE-J01H.

125/126

Control System

Control System

Wired Controller

HYXM-VB01

HYXE-M01H

Features: Touchscreen, use fingers to tap objects on the touchscreen instead of keyboard. 86mm×90mm

Colorful and 3.5 inches.

Features:

Adjust the screen that is synchronous with running light for current light conditions.

Streamline appearance design, white highlight shell. Large LCD screen, humanized operation interface.

86mm×86mm

Touch key control, easy and convenient.

The most accurate streamlined design in the industry. Match all kinds of hisense VRF indoor units. Modify the address of indoor units.

White backlight; operation indicator light.

Prevent children from touch by mistake.

Infrared remote control is acceptable, realizing two control method: wired control and remote control.

Display room temperature. Include wireless receiver.

Main Functions

Main Functions

86×86mm Smart Size

Temperature Setting

72-hour Timer

Cooling/Heating/Dry/Fan/Auto

Check

Air Filter Cleaning Reminding

Error Code Display

Inserting

Dehumidification

Multiple Speed/Swing Louver

Backlight

Max.6 indoor Units Can be Connected

Cooling/Heating/Dry/Fan/Auto

Temperature Setting

Timer

Error History Display

Check

Air Filter Cleaning Reminding

0.5 C Temperature Setting

Weekly Timer

Address Setting

3D Airflow Setting

Auto-brightness

Holiday Setting

Multiple Fan Speed

Child Lock

Auto-dehumidification

o

HYXE-VA01 Features:

HYXE-S01H

New fashion appearance, big display LCD and touch button, and good user operation experience. Support 6 level fan speed and 0.5oC temperature adjustment. Supports low temperature automatic dehumidification.

120mm×120mm

Individual setting of wind deflector.

Features: Half-size design:120 mm×70mm×17mm. Max. 16 indoor units connectable. Icon Function Display.

Support room temperature display and backlight brightness adjustment. Support human sense control function (not available for Console IDU). Support health, sleep, mute, energy saving and breeze setting.

120mm×70mm

Main Functions

Main Functions

Cooling/Heating/Dry/Fan/Auto

Temperature Setting

Timer

Cooling/Heating/Dry/Fan/Auto

0.5℃ Temperature Setting

72-hour Timer

3 or 6 Speed Control

Check

Air filter Cleaning Reminding

Error Code Display

Check

Air Filter Cleaning Reminder

Touch Buttons

Quiet

Dehumidification

Multiple Speed

3D Airflow Setting

Backlight Control

Fan Speed/Swing Louver

Optional Setting

Test Run

Swing Louver

One Touch Test Run

Max. 16 Indoor Units Can be Connected

Optional Setting

127/128

Control System

Control System

Wireless Controller

Centralized Controller

HYE-W01

HYJM-S01H Features:

Features: Different colors of common used keys.

145mm×55mm

White backlight, convenient for night operation. Multi-functional, intelligent and humanized.

6 Fan Speed/Swing Louver

148mm×200mm

Main Functions

Main Functions Cooling/Heating/Dry/Fan/Auto

7-inch touch screen design. Maximum 160 history alarm records information. Multiple languages support. (Chinese, English, Spanish, Turkish, Russian, Italian, German, Dutch). Record accumulated operating time of each indoor unit. Service contact information can be shown and setting. Max.64 remote control groups and Max 160 indoor units are available.

Temperature Setting Quiet Mode Setting

Sleep Mode Setting

24-hour Timer Dehumidification

Clock Setting

Time Display Mode Setting

Energy Saving Control Mode

Alarm History

Backlight

Holiday Setting

Setting Temperature Limitation

Service Hotline Setting

Power Indicator

Backlight Brightness Adjusting

Backlight Auto-off Time Adjusting

Weekly Schedule

Easy Installation

Smooth Appearance 220

Unit:mm

20

53

Unit:mm

33

148

Receiver Kit for Wireless Control - optional

Centralized ON/OFF Controller: HYJ-J01H Features:

Large size touch-key control design Slim design with a thickness of 12.5mm It can control up to 16 wired controller groups,realizing centralized ON/OFF control Max.128 indoor units can be connected

120mm×120mm

Main Functions Group Control(ON/OFF)

Indoor Units Auto Login in

Compact Structure Design

Indoor Unit Power OFF Reminder

Error Reminder

Centralized ON/OFF Control

129/130

Control System

Control System Type Model

Hi-Mit

Wired Controller HYXE-VA01

HYXE-J01H

HYXE-M01H

Wireless Controller HYXM-VB01

HYXE-S01H

HYE-W01

Picture

Ceiling Duct Type 4-Way Cassette Mini 4-Way Cassette 1-Way Cassette 2-Way Cassette

Suit for indoor unit

Ceiling&Floor



Wall Mounted



Floor Concealed DC Low Height AC Low Height Console Type



All Fresh Air Indoor Unit Heat Recovery Ventilation



3D Air-flow Panel AHU KIT

Type Model

Main Functions

Receiver Kit HYRE-V02H

HYRE-T02H

HYRE-X01H

Centralized Controller

ON/OFF

HYJM-S01H

HYJ-J01H

Picture

Ceiling Duct Type

ON/OFF Control, Operation Mode, Temperature Setting Operate According to a Schedule

4-Way Cassette

Display the Alarm Code

Mini 4-Way Cassette

16 operation modes

1-Way Cassette

Max. 32 Indoor Units Can be Controlled

2-Way Cassette

Dimension: 215×137×38 mm

Ceiling&Floor Wall Mounted

Adapter Specifications

Suit for indoor unit

Model name

HYJE-H01H

Operating Temperature

0 C~40 C

Input Voltage

AC 110~240V 50/60Hz

Maximum Operating Current

10mA (220 V)

o

o

*The standard parts of this system includes the converter HYJE-H01H and the client control software HRM-G01 ( it can be downloaded and installed in the APP STORE ), The iPhone,iPad is the registered trademark of Apple Inc.

Floor Concealed DC Low Height AC Low Height Console Type All Fresh Air Indoor Unit Heat Recovery Ventilation 3D Air-flow Panel AHU KIT

Remarks:

○ Optional × Incompatible

√ Standard

131/132

Control System

Control System

Building Management System

HCPC-H2M1C Modbus

Compatible to multiple communication protocol of BACnet, MODBUS etc. Connectible to BMS or Smart Home System via HC-A64BNP or HCPC-H2M1C all of which can connect to Max. 64 indoor units. Real-time operation status monitoring for inquiry Operation order from monitoring center

HC-A64BNP BACnet

On-Off Setting

Operating Mode Setting

Airflow Setting and Monitoring

Wind Setting and Monitoring

Temperature Setting

Inlet Air Temp. Monitoring

All Units On/Off Control

Alarm Monitoring and Code Display

Converter Specifications HC-A64BNP

HCPC-H2M1C

Converter Item BMS Connection Power Supply Running-state Monitoring / On-off Setting

Operating Mode Setting

Temperature Setting and Monitoring

Connectable Central Controller

Airflow Setting and Monitoring

Alarm Monitoring and Code Display

Communication Failure Display

MAX.Number of Connectable Indoor Units

Wireless Controller Permission/Prohibition

Indoor Temp. Monitoring

Filter Cleaning Prompting

Dimension(LxWxH)

BACnet

Modbus

AC100~240V±10%(50/60Hz)

AC100~240V±10%(50/60Hz)

HYJM-S01H

HYJM-S01H, Hi-Dom, HYJ-J01H

64

64

240mm×204mm×70mm

220mm×140mm×50mm

133/134

Control System

Control System

BACnet Intesis Box BACnet server makes available the Hisense VRF conditioning system through independent BACnet objects. It can be applied to third party intelligent control system with BACnet/IP or BACnet MSTP protocol.

IntesisBox KNX – Hisense AC is a communication gateway for the integration of Hisense air conditioning systems into KNX TP-1 (EIB). Wide range of monitoring & control datapoints available. Outdoor unit’s signals available for the integration. Example: Device as Slave

Main Functions Central control of all indoor units Indoor unit data monitoring Heat/ Dry/ Fan/ Cool/ Auto mode control

TOUCH SCREEN

Vane position swing control Function prohibition of wired controller

H-NET Indoor Unit

BACnet IP (Ethernet)

Windows blinds

BMS

Energy management

Outdoor Unit H-NET

H-NET Indoor Unit

Alarms

Lighting

Indoor Unit Outdoor Unit

Outdoor Unit

HVAC H-NET

BACnet MSTP (RS485)

Indoor Unit Outdoor Unit

KNX

Model

H(mm)

W(mm)

D(mm)

Max.number of connectable indoors units

KNX

HS-RC-KNX-1i

70

70

28

1

KNX

HS-AC-KNX-16

90

88

56

16

KNX

HS-AC-KNX-64

90

88

56

64

BACnet

HS-AC-BAC-16

90

88

56

16

BACnet

HS-AC-BAC-64

90

88

56

64

Hi-Motion

Multiple objects for control and status (bit, byte, characters…) with KNX standard datapoint types. Control of the AC unit based on the ambient temperature read by the own AC unit, or in the ambient temperature read by any KNX thermostat. Total Control and Monitoring of the AC unit from KNX, including monitoring of AC unit’s state of internal variables, running hours counter (for filter maintenance control), and error indication and error code. Up to 5 scenes can be saved and executed from KNX, fixing the desired combination of Operation Mode, Set Temperature, Fan Speed, Vane Position and Remote Controller Lock at any moment by using a simple switching. Example: Device as Master

intelligent sensor

Main Functions High Precision Adjust AC temperature precisely according to the number of users

Wide Range Sense as much as 70m2 with almost no blind area

High Energy Conservation TOUCH SCREEN

Turn off AC automatically when nobody is in the room Hi-Motion

A

Windows blinds

Alarms

Energy management

B

Remote control Switch REMOCON

A

REMOCON

B

Electrical Box of lndoor Unit Terminal Board A

B

M3.5 Screws

Electrical Box of lndoor Unit Terminal Board A

B

M3.5 Screws

Lighting HVAC

Twist Pair Cable with Shield Tube:1P-0.75MM2 or more

135/136

Control System

Control System

Hi-Dom Air Conditioning Management System

Electric Charge Allocation Hi-Dom air conditioning management system consists of meter reading system and air conditioning management system. In accordance with the operation time and capacity output of indoor and outdoor units, the electric charge allocation software allocates the total power consumption to each indoor unit.

Centralized Control Hi-Dom air conditioning management system adopts communication bus connection, air conditioning indoor units are connected to the computer through network converter; the system is all controlled automatically by a computer with powerful functions and simple operation. One single computer control system can manage 4,096 indoor units.

Note:Due to different laws and regulations in different regions, Hisense electrical charge calculation software need to customize processing in project according to the users' requirement. Note:Only support iEM3150 or iEM3350, which is supplied by Schneider Electric

Main Functions Running-state Monitoring Determine the Temperature Limit Running Records Display Controller Prohibition Function

Electric Meter

Access Control Automatic Operation According to Settings Multifunction Alarm Service Monitoring

AC System

Power Supply Cable

M-concentrator (Meter Reader)

Network Connector

AC System

Shielded Twisted Pair Cable AC System

All the indoor units and outdoor units connected with one adapter comprise one communication BUS system. Max.128 indoor units can be connected to an adapter. Max.32 adapters can be controlled by one computer. Max.4096 indoor units are under control.

Hi-Dom System Specifications Adapter (Hi-Dom)

Model Name

Power Supply

Dimension(mm)

Charging Function

HCCS-H128H2C1YM

DC 12V

180×110×40

With charging function

HCCS-H128H2C1NM

DC 12V

180×110×40

Without charging function

HCCS-H247R4C1E

DC 12V

180×110×40

Note:HCCS-H247R4C1E is an essential equipment for HCCS-H128H2C1YM to charging.

137/138

Optional Parts

Optional Parts

Selection Software

Support Optional Parts

Hisense selection software is a Windows-based program which can run in Window XP and other higher operating systems. This software supports multiple languages, and is convenient for users from different countries.Users can get the latest updated products information easily, because Hisense selection software supports product database update. Besides, this software is very intelligent. It not only supports manually drawing but also can generate device piping diagram, wiring diagram and project detailed report automatically. Furthermore, the software supports insertion of architectural drawing in DWG,PDF,JPG and PNG file formats, and designing on the architectural drawing.

139/140

Support

Design Software

Optional Parts CFD What is CFD technology ? CFD stands for Computational Fluid Dynamics, which is the science of predicting fluid flow, heat transfer, mass transfer, chemical reactions, and related phenomena by solving the mathematical equations which govern these processes using a numerical process (that is, on a computer).

What can we do with CFD technology ? CFD is the best method to analyze the air flow of building ventilation. It can provide the detailed and obvious simulation result, for example, indoor airflow distribution and temperature and velocity fields around the outdoor unit. These results will bring some good design advice to the architect or consultant before construction. In addition it’s very fast and low cost.

GCSS Hisense VRF design software is based on Autocad 2008~2016 which supports both 32-bit and 64-bit operating system. It involves the latest all ranges of products of Hisense, and supports online database update. The software supports system calculating for refrigerant pipes and condensate pipes. Besides, the installation material and the amount of the refrigerant charge can be calculated through the software. So that users can design the system easily.

BIM BIM(Building Information Modeling )has become an umbrella term to cover many aspects.​ Hisense can provide up-to-date graphic and parametric product information that is ready to use in any BIM process. ​Hisense offers the MEP engineers the needed Revit families and 3D DWG's to optimize their BIM model.​

Hisense GCSS(Global Customer Service System)is after-sales service online web-based System for Hisense VRF, it’s can be freely accessed by Hisense certificated service partners and Hisense agents. GCSS has 4 main functions, including life-cycle project management, spare part support, warranty claim system and online call center.

141/142

Optional Parts

Optional Parts

Piping Connection Kit Branch Pipe (For indoor unit)

Manifold Pipe (For outdoor unit) (Indoor Unit on Left Side)

First Branch Pipe

Outdoor Unit A

Outdoor Unit B

Outdoor Unit C

Outdoor Unit D

For Hi-FLEXi S Series Heat Pump System Outdoor Unit HP

8 to 10

12 to 16

18 to 24

26 to 44

46 to 66

68 to 112

Branch Pipe

HFQ-102F

HFQ-162F

HFQ-242F

HFQ-302F

HFQ-462F

HFQ-682F

For Hi-FLEXi G+ Series 2-Pipe Heat Pump System

d

b

a

e c

To Indoor Units Manifold Pipe 1

Manifold Pipe 2

f

g

Outdoor Unit HP

8 to 10

12 to 16

18 to 24

26 to 44

46 to 66

68 to 88

Branch Pipe

HFQ-102F

HFQ-162F

HFQ-242F

HFQ-302F

HFQ-462F

HFQ-682F

For Hi-FLEXi X High Efficiency Series Heat Pump System

Manifold Pipe 3

Outdoor Unit HP

8 to 10

12 to 16

18 to 24

26 to 48

50 to 64

Branch Pipe

HFQ-102F

HFQ-162F

HFQ-242F

HFQ-302F

HFQ-462F

For Hi-FLEXi S Series Heat Pump System Outdoor Unit Manifold Pipe1

AVWT-290~422HKSS AVWT-444~544HKSS AVWT-552~634HKSS HFQ-M32F

HFQ-M462F

AVWT-654HKSS

AVWT-676~816HKSS AVWT-824~886HKSS AVWT-908~1088HKSS

HFQ-M682F

HFQ-M682F

HFQ-M682F

HFQ-M682F

HFQ-M32F

HFQ-M32F

HFQ-M462F

HFQ-M462F

HFQ-M462F

Outdoor Unit HP

8 to 10

12 to 16

18 to 24

26 to 54

HFQ-M32F

HFQ-M462F

Branch Pipe

HFQ-102F

HFQ-162F

HFQ-242F

HFQ-302F

Manifold Pipe2 Manifold Pipe3

For Hi-FLEXi R Series Heat Recovery System

For Hi-FLEXi G+ Series Heat Pump System Outdoor Unit

AVWT-232UKSZA

AVWT-250~420UKSZA

AVWT-438~630UKSZA

AVWT-649~840UKSZA

Manifold Pipe1

HFQ-M22F

HFQ-M32F

HFQ-M462F

HFQ-M682F

HFQ-M32F

HFQ-M32F

Manifold Pipe2 Manifold Pipe3

Manifold Pipe 1

AVWT-172~229UESZX

AVWT-250~307UESZX

HFQ-M22F

HFQ-M32F

Manifold Pipe 2

AVWT-324~386UESZX

AVWT-404~460UESZX HFQ-M32F

HFQ-M462F

HFQ-M22F

HFQ-M32F

HFQ-M32F HFQ-M32F

AVWT-190~232FE(7)SZ HFQ-M22F

AVWT-250~340FE(7)SZ

AVWT-364~510FE(7)SZ

HFQ-M32F

HFQ-M32F

Manifold Pipe 2

HFQ-M32F

Manifold Pipe 1 Manifold Pipe 2

18 to 24

26 to 36

38 to 54

HFQ-M452F

HFQ-M562F

HFQ-M692F

HFQ-M902F

For Hi-FLEXi S Series 2-Pipe Heat Pump System Total Indoor Unit HP Lower than 6

AVWT-190~232FE(7)SZ

AVWT-250~340FE(7)SZ

AVWT-364~510FE(7)SZ

HFQ-M202F

HFQ-M212F

HFQ-M302F HFQ-M302F

6 to 8.99

9 to 11.99

12 to 15.99

16 to 17.99

18 to 25.99

26 to 33.99

34 to 45.99

46 to 58.99

59 to 68.99

Over 69

Gas (Φmm)

15.88

19.05

22.2

25.4

28.6

28.6

31.75

38.1

41.3

44.5

50.8

Liquid (Φmm)

9.53

9.53

9.53

12.7

12.7

15.88

19.05

19.05

22.2

22.2

25.4

Branch Pipe

HFQ-102F

HFQ-102F

HFQ-102F

HFQ-162F

HFQ-162F

HFQ-242F

HFQ-302F

HFQ-302F

HFQ-462F

HFQ-462F

HFQ-682F

For Hi-FLEXi G+ Series 2-Pipe Heat Pump System Total Indoor Unit HP

For Hi-FLEXi R Series Heat Recovery System Outdoor Unit

12 to 16

HFQ-M282F

AVWT-480~620UESZX

HFQ-M32F

For Hi-FLEXi R Series 2-Pipe Heat Pump System Manifold Pipe 1

8 to 10

Branch Pipe

First Branch Pipe~ Last Branch Pipe

Manifold Pipe 3

Outdoor Unit

Outdoor Unit HP

HFQ-M32F

For Hi-FLEXi X Series Heat Pump System Outdoor Unit

For Hi-FLEXi R Series 2-Pipe Heat Pump System

HFQ-M462F

Lower than 6 6 to8.99

9 to11.99 12 to15.99 16 to17.99 18 to25.99 26 to33.99 34 to45.99 46 to57.99 58 to67.99

Gas (Φmm)

Φ15.88

Φ19.05

Φ22.2

Φ25.4

Φ28.6

Φ28.6

Φ31.75

Φ38.1

Φ41.3

Φ44.5

Liquid (Φmm)

Φ9.53

Φ9.53

Φ9.53

Φ12.7

Φ12.7

Φ15.88

Φ19.05

Φ19.05

Φ22.2

Φ22.2

Branch Pipe

HFQ-102F

HFQ-162F

HFQ-242F

HFQ-302F

HFQ-462F

68 Φ50.8 Φ25.4 HFQ-682F

143/144

Optional Parts

Optional Parts

Manifold Pipe Parameter For Hi-FLEXi X Series 2-Pipe Heat Pump System Total Indoor Unit HP Lower than 6

6 to 8.99

9 to 11.99

12 to 15.99

16 to 17.99

18 to 25.99

26 to 35.99

36 to 47.99

48 to 57.99

58 to 64

Gas (Φmm)

15.88

19.05

22.2

25.4

28.6

28.6

31.75

38.1

41.3

44.5

Liquid (Φmm)

9.53

9.53

9.53

12.7

12.7

15.88

19.05

19.05

22.2

22.2

Branch Pipe

HFQ-102F

HFQ-102F

HFQ-102F

HFQ-162F

HFQ-162F

HFQ-242F

HFQ-302F

HFQ-302F

HFQ-462F

Model

Gas Line ID 25.4

ID 28.6 ID 25.4

ID 28.6

HFQ-M22F

HFQ-462F

Ø 25.4

Ø 22.2

Ø 22.2 ID 22.2

ID 15.88

ID 19.05

ID 12.7 ID 38.1

For Hi-FLEXi R Series 2-Pipe Heat Pump System Total Indoor Unit HP

ID 31.75

HFQ-M32F

Lower than 6

6 to 8.99

9 to 11.99

12 to 15.99

16 to 17.99

18 to 25.99

26 to 35.99

Over 36

Φ15.88

Φ19.05

Φ22.2

Φ25.4

Φ28.6

Φ28.6

Φ31.75

Φ38.1

Gas (Φmm) Liquid (Φmm)

Φ9.53

Φ9.53

Φ9.53

Φ12.7

HFQ-102F

Branch Pipe

Φ12.7

Φ15.88

HFQ-162F

Φ19.05

HFQ-242F

ID44.5

HFQ-M462F

Lower than 6

6 to 8.99

9 to 11.99

12 to 15.99

16 to 17.99

18 to 21.99

22 to 25.99

26 to 35.99

Over 36

Low Pressure Gas (Φmm)

Φ15.88

Φ19.05

Φ22.2

Φ25.4

Φ28.6

Φ28.6

Φ28.6

Φ31.75

Φ38.1

High Pressure Gas (Φmm)

Φ12.7

Φ15.88

Φ19.05

Φ22.2

Φ22.2

Φ22.2

Φ25.4

Φ28.6

Φ31.75

Liquid (Φmm)

Φ9.53

Branch Pipe

HFQ-M142F

Φ9.53

Φ9.53

HFQ-M282F

Φ12.7 HFQ-M452F

Φ12.7

Φ15.88

HFQ-M562F

Φ15.88

Φ19.05

HFQ-M692F

Φ19.05

OD 31.75

ID 9.53 ID 15.88 ID 19.05

ID 12.7

ID 6.35

ID22.2 ID19.05

ID9.53 ID12.7 ID15.88

25.4×t1.2 19.05×t1.0

ID38.1

ID28.6

ID12.7

ID28.6 ID31.75 ID38.1

50.8×t2.5

ID38.1

Low Pressure Gas Line

38.1×t2.0

28.6×t1.9

ID31.75

25.4×t1.45

ID28.6

ID22.2

High Pressure Gas Line

ID 25.4

ID 25.4 OD 28.6

ID 15.88 ID 12.7

Q'ty : 1

ID 19.05 Q'ty : 1

OD 38.1 ID 34.92 OD31.75

Q'ty : 1

ID28.6 ID22.2 ID25.4

ID19.05 ID22.2 25.4×t1.4

31.75×t1.2

ID25.4

ID25.4

ID15.88 ID12.7

ID25.4

ID9.53 28.6×1.2t

ID6.35

ID19.05 ID22.2

ID22.2

OD31.75

ID19.05 ID25.4

ID 22.2

ID 28.6

ID 22.2

ID 22.2 Ø 22.2

ID 12.7 ID 9.53

ID15.88

38.1×t2.0

Model

ID 12.7 ID 22.2

ID31.75

ID53.98

HFQ-M682F

38.1×t2.0

ID 19.05

ID 6.35

38.1×t2.0

ID50.8

For Hi-FLEXi R Series Heat Recovery System Total Indoor Unit HP

41.3×t2.0

ID31.75 ID38.1

ID 12.7

ID 9.53

ID 15.88

Ø 19.05 ID 15.88

ID 28.6

ID41.3

ID 15.88

ID 22.2

Ø 19.05

ID 19.05

ID 25.4 OD 28.6

Ø 19.05

Ø 25.4

Ø 25.4

Ø 28.6

Reducer for Liquid Line

ID 9.53 ID 12.7 ID 15.88

ID 15.88

Ø 31.75

Ø 31.75

Φ19.05

HFQ-302F

ID 32.0

ID 38.1

Reducer for Gas Line

Liquid Line

ID28.6 ID22.2

ID15.88

25.4×t1.45 ID19.05

31.75×t1.2

ID25.4

ID25.4

ID15.88 ID12.7

28.6×1.2t

ID15.88

Liquid Line

ID19.05 ID22.2

Reducer for Low Pressure Gas Line

Reducer for High Pressure Gas Line

Reducer for Liquid Line

HFQ-M902F HFQ-M202F

Last Branch Pipe~Indoor Unit Indoor Unit

Notes

Pipe Size (Φmm) Gas Pipe

Liquid Pipe

Max. Liquid Pipe Length

7kBtu/h~14kBtu/h

12.7

6.35

15

17kBtu/h~18kBtu/h

15.88

6.35*1

15

22kBtu/h~54kBtu/h

15.88

9.53

40

76kBtu/h

19.05

9.53

40

96kBtu/h

22.2

9.53

40

1. When liquid pipe length of indoor unit(07~18kBtu/h) is more than 15m, please change the liquid pipe dimension from Φ6.35 into Φ9.53.

HFQ-M212F

HFQ-M302F

Unit: mm, ID: Inner Diameter,OD: Outer Diameter

145/146

Optional Parts

Optional Parts

Branch Pipe Parameter

Branch Pipe Parameterer

Model Model

Gas Line

Reducer for Gas Line

Liquid Line

Low Pressure Gas Line

High Pressure Gas Line

Liquid Line

Reducer for Low Pressure Gas Line

Reducer for High Pressure Gas Line

Reducer for Liquid Line

Reducer for Liquid Line

HFQ-M142F

HFQ-052F

Q'ty :2

HFQ-102F

HFQ-M282F

Q'ty :2

HFQ-162F

HFQ-M452F Q'ty :1

Q'ty :2

Q'ty :1

Q'ty :1

Q'ty :2

Q'ty :1

Q'ty :1

Q'ty :1

HFQ-242F

HFQ-M562F

HFQ-302F

HFQ-M692F HFQ-462F

Q'ty :1 Q'ty :1

ID50.8 ID53.98

ID28.6

ID31.95 ID38.1

ID25.4

ID15.88 ID19.05 ID22.2

OD31.75 ID28.6 ID22.2

31.75×t1.2

HFQ-682F

50.8×t2.5 38.1×t2.0 ID38.1

38.1×t2.0 ID31.75 ID28.6

25.4×t1.45

28.6×t1.9 25.4×t1.45 ID22.2

ID25.4

Q'ty :1

Q'ty :1

Q'ty :1

HFQ-M902F

ID15.88 ID12.7

ID19.05 ID15.88

ID25.4

Q'ty :1

28.6×1.2t

Q'ty :1

ID19.05

Q'ty :1

ID22.2

Unit: mm, ID: Inner Diameter,OD: Outer Diameter

Q'ty :1

Unit: mm, ID: Inner Diameter,OD: Outer Diameter *with or without insulation, please contact our sales person or professional engineers

147/148

Optional Parts

Optional Parts

Filter

Switch Box (heat recovery system only)

Ceiling Ducted Type(Slim)

214mm

Others 301mm

Hisense

Applicable models

AVE-07~14*

HF-40L-ZFE

Picture

Ceiling Ducted Type (Low&High Static Pressure)

Changeover box for heat recovery application Compact and light design Minimized unit and less suspension bolts facilitate

191mm

Model

Applicable models

AVD-07~14*

KW-PP1Q

AVD-17~24*

KW-PP2Q

AVD-27~38*

KW-PP3Q

AVD-48~54*

KW-PP4Q

AVD-76*

HF-224L-FE

AVD-96*

HF-280L-FE

Picture

installation and handing methods

Specifications Model

Model

Specifications W×D×H(mm)

Indoor Unit Connection Net Weight(kg)

HCH-160D 301×214×191

7

HCH-280D

Total HP

Number of Indoor Units*

6HP≥

1~7

6.1HP to 10HP

1~8

*When multiple indoor units are connected to the same switch box unit, they are controlled with the same operation mode.

Drain Pump—Optional 3D Air-flow Panel Panel Model

Applicable Models

HP-DB-NA

0.8-1.5HP

180×950×70

750×130

HP-EB-NA

1.8-2.5HP

180×1220×70

1020×130

Note:For Ceiling Ducted Type (DC/AC Low-height)

Outer Dimensions (H×W×D)

Interface Dimension (H×W×D)

Model

Power supply

Consumption MAX. Lift

HPS-132

AC 220~240V(50/60Hz)

9±1.5 W

900

For Ceiling ducted type(0.8~2.5Hp)

HPS-162

AC 220~240V(50/60Hz)

9±1.5 W

900

For Ceiling ducted type(3.0~6.0Hp)

HPS-151

AC 220~240V(50/60Hz)

9±1.5 W

600

External type,for general purpose(0.8~10Hp)

Applicable models

(mm)

Note:For High Static Pressure Ceiling Ducted Type and Low Static Pressure Ceiling Ducted Type only.

HPS-132/HPS-162

HPS-151

Optional Parts

Technology We are passionate about technology and making it accessible to the world. We believe that for technology to be truly innovative, it has to be accessible. It's not about what it is; it's about what it does. Technology connects us to our passion. It should make our world a better place. It should make what we want to do, where we want to go, and what we want to learn easier. And, it should be easy to use and available to everyone. Our mission is to develop technological innovations that improve the lives of others. We want our customers to happily exclaim, "Life is better with Hisense."

Warranty We are passionate about standing behind our products. We believe that products should perform so well that customers shouldn't need a warranty, but unexpected things happen. Therefore, all our products come with a warranty to provide peace of mind that, should something go wrong, we will stand behind our products.

Quality & Value We are passionate about building dependable, easy-to-use, affordable products. We believe the best things in life exceed expectations and that everyone should be able to enjoy the benefits of state-of-theart technology. We take pride in the quality of our products. Our stringent Quality Improvement Process helps ensure we offer products that we're proud to sell and that you are proud to own. We want you to feel confident when buying Hisense, because we're a reliable brand that you can trust. Our "best value for your money" commitment gives our customers assurance that buying Hisense is the smart choice.

Service We are passionate about making our customers happy. We believe that manufactures need to be there after the sale. Technology changes rapidly and sometimes you need a little guidance along the way. Our service team is here to help. And, if you should have a problem, we want to help get it solved as fast as possible. Additionally, our service team works side-by-side with R&D, engineering, sales and marketing to ensure companywide understanding of our customers and how our products are performing.